Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

The Measurement of MTFs in X-ray Microscopy Using Diffractograms

A novel method to characterize the optical performance of a high-resolution transmission x-ray microscope is presented. It makes use of test patterns that consist of random arrays of sub-resolution holes in a thin metal film, and so approximate to white-noise input signals for the microscope. The test patterns have been fabricated by electron-beam lithography at length scales appropriate for the resolution available in x-ray microscopy, so that diffractograms produced from the image data can be directly interpreted in terms of the contrast transfer function of the optical system. Results of this method are shown for both brightfield and differential phase contrast imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Design and Fabrication of Safety Shutter for Indus-2 Synchrotron Front-ends

This paper describes the design and fabrication of safety shutter for the Indus-2 synchrotron source on bending magnet front-ends. The purpose of the safety shutter is to absorb Bremsstrahlung radiation generated due to scattering of electron beam from residual gas ions and components of the storage ring. The safety shutter consists of a radiation absorber actuated inside a rectangular ultra high vacuum chamber by pneumatic actuator. A water-cooled copper block is mounted before the absorber block to protect it from the incident heat load due to synchrotron radiation. The top flanges of the chamber are made with rectangular knife edge sealing which is found to be better than wire seal at higher temperature. The physics aspect of safety shutter is designed using simulation code Electron Gamma Shower EGS-4 code.

43 PARTICLE ACCELERATORS↗

Radiation characteristics of a source in a thin substrate mounted over a dielectric medium

The radiation pattern of a line source is calculated for the case in which the source is lying on the top or the bottom surface of a lossless dielectric substrate that is mounted on the top of semiinfinite dielectric medium. It is found that in both cases the pattern along the interfaces has a null; that the pattern in the upper semiinfinite medium has a single lobe; and that the pattern in the lower semiinfinite medium has many lobes, the number of which varies with the substrate thickness. In both cases, the power radiated into the lower medium is more than that radiated into the upper medium. Applications of this calculation to remote sensing, microstrip antenna technology, and antenna arrays are discussed.

Engheta, Nader↗

Microfocused X-rays Beams Using Compound Refractive Lenses: Possibilities for Indus-2

For the generation of micro focused hard x-ray beams on Indus-2, with large depth of focus and large focal lengths, simulation studies have been performed using parabolic Be compound refractive lenses (CRLs). The use of these lenses is expected to open many new experimental possibilities widely used at other synchrotron sources.

43 PARTICLE ACCELERATORS↗

Wellbore detector with azimuthal and spectral energy resolution

A wellbore inspection device includes a radiation generation source operable to emit neutrons, and a radiation detector fixed relative to the radiation generation source and operable to detect backscattered neutron radiation from a surrounding environment. The radiation detector includes a plurality of individually addressable detector elements arranged in one or more concentric rings. Respective amounts of backscattered neutron radiation detected by the individually addressable detector elements within a ring is indicative of the azimuthal direction of the detected backscattered neutron radiation, and the respective amount of backscattered neutron radiation detected by the individually addressable detector elements of two or more concentric rings is indicative of an energy level of the backscattered neutron radiation. The inspection device determines whether a potential anomaly is present in or around the wellbore, based at least in part on the respective amounts of backscattered radiation detected by the individually addressable detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A COMPARISON OF X-RAY AND MID-INFRARED SELECTION OF OBSCURED ACTIVE GALACTIC NUCLEI

We compare the relative merits of active galactic nuclei (AGNs) selection at X-ray and mid-infrared wavelengths using data from moderately deep fields observed by both Chandra and Spitzer. The X-ray-selected AGN sample and associated photometric and spectroscopic optical follow-up are drawn from a subset of fields studied as part of the Serendipitous Extragalactic X-ray Source Identification (SEXSI) program. Mid-infrared data in these fields are derived from targeted and archival Spitzer imaging, and mid-infrared AGN selection is accomplished primarily through application of the Infrared Array Camera (IRAC) color-color AGN 'wedge' selection technique. Nearly all X-ray sources in these fields which exhibit clear spectroscopic signatures of AGN activity have mid-infrared colors consistent with IRAC AGN selection. These are predominantly the most luminous X-ray sources. X-ray sources that lack high-ionization and/or broad lines in their optical spectra are far less likely to be selected as AGNs by mid-infrared color selection techniques. The fraction of X-ray sources identified as AGNs in the mid-infrared increases monotonically as the X-ray luminosity increases. Conversely, only 22% of mid-infrared-selected AGNs are detected at X-ray energies in the moderately deep ((t{sub exp}) approx 100 ks) SEXSI Chandra data. We hypothesize that IRAC sources with AGN colors that lack X-ray detections are predominantly high-luminosity AGNs that are obscured and/or lie at high redshift. A stacking analysis of X-ray-undetected sources shows that objects in the mid-infrared AGN selection wedge have average X-ray fluxes in the 2-8 keV band 3 times higher than sources that fall outside the wedge. Their X-ray spectra are also harder. The hardness ratio of the wedge-selected stack is consistent with moderate intrinsic obscuration, but is not suggestive of a highly obscured, Compton-thick source population. It is evident from this comparative study that in order to create a complete, unbiased census of supermassive black hole growth and evolution, a combination of sensitive infrared, X-ray, and hard X-ray selection is required. We conclude by discussing what samples will be provided by upcoming survey missions such as WISE, eROSITA, and NuSTAR.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

43 PARTICLE ACCELERATORS↗

Computational Assessment of Naturally Occurring Background Radiation Produced by Extraterrestrial Sources - Paper 43

In recent years there has been increased interest in developing the ability to account for background radiation in real (or near-real) time in support of end-user field experiments or operational search missions. More specifically, the focus has been on creating an array of tools that can provide an estimate of the natural occurring radiation that an experimentalist or search operator can use in the field in real time while making a measurement. Conceptually, these tools would allow the experimentalist or search operator to be able to dynamically account for the background associated with the measurement resulting in significant improvement in the probability of detection and minimization of the false alarm rate. The purpose of this work is to assess the extraterrestrial sources that produce naturally occurring background, the variation of these sources, and the variation in the background due to the sources and the potential measurement environment. This work is part of a larger project that will also assess terrestrial sources of background radiation. The focus of this paper is only the neutron background produced by extraterrestrial sources. The computational assessment will be performed using MCNP6. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Funding Support and Principal Investigator Leadership of Oncology Clinical Trials Using Radiation Therapy

Sources of funding and principal investigator (PI) leadership for clinical trials using radiation therapy (RT) are not well characterized but are important mediators of innovation, particularly because funding for trials from the National Institutes of Health (NIH) has decreased and industry funding has increased. We sought to determine characteristics of trials using RT that are associated with industry funding, NIH funding, and radiation oncologist (RO) PI leadership.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic radiation patterns for a source in a hard-walled unflanged circular duct

Acoustic radiation patterns are measured over a 320 deg arc for a point source in a finite length, hard walled, unflanged circular duct. The measured results are compared with computed results which are based on the Wiener-Hopf solution for radiation from a semi-infinite unflanged duct. Measurements and computations are presented for frequencies slightly below and slightly above each of the first four higher order radial mode cutoff frequencies. It is found that the computed and measured patterns show better agreement below the mode cut-off frequencies than above and that the agreement is better at lower frequencies that at higher frequencies. The computed radiation patterns do not show fine lobes which are caused by diffraction from the back end of the duct.

Holm, R. G.↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

Development of Coherent X-ray Diffraction Apparatus with Kirkpatrick-Baez Mirror Optics

To realize coherent x-ray diffraction microscopy with higher spatial resolution, it is necessary to increase the density of x-ray photons illuminated onto the sample. In this study, we developed a coherent x-ray diffraction apparatus with Kirkpatrick-Baez mirror optics. By using mirrors fabricated by elastic emission machining, a high-density coherent x-ray beam was produced. In a demonstration experiment using a silver nanocube as a sample, a high-contrast coherent x-ray diffraction pattern was observed over a wide-q range. This proves that both the density and the degree of coherence of the focused beam were high.

07 ISOTOPE AND RADIATION SOURCES↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

Preliminary Results from Pyroelectric Crystal Accelerator

The Nuclear Science and Engineering Research Center (NSERC), a Defense Threat Reduction Agency (DTRA) office located at the United States Military Academy (USMA), sponsors and manages cadet and faculty research in support of DTRA objectives. Cadets in the Department of Physics and Nuclear Engineering at USMA are using pyroelectric crystals to ionize and accelerate residual gas trapped inside a vacuum system. A system using two lithium tantalate crystals with associated diagnostics was designed and is now operational. X-ray energies of approximately 150 keV have been achieved. Future work will focus on developing a portable neutron generator using the D-D nuclear fusion process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering and; Delay, Scale, and Sum Migration

How do we see? What is the mechanism? Consider standing in an open field on a clear sunny day. In the field are a yellow dog and a blue ball. From a wave-based remote sensing point of view the sun is a source of radiation. It is a broadband electromagnetic source which, for the purposes of this introduction, only the visible spectrum is considered (approximately 390 to 750 nanometers or 400 to 769 TeraHertz). The source emits an incident field into the known background environment which, for this example, is free space. The incident field propagates until it strikes an object or target, either the yellow dog or the blue ball. The interaction of the incident field with an object results in a scattered field. The scattered field arises from a mis-match between the background refractive index, considered to be unity, and the scattering object refractive index ('yellow' for the case of the dog, and 'blue' for the ball). This is also known as an impedance mis-match. The scattering objects are referred to as secondary sources of radiation, that radiation being the scattered field which propagates until it is measured by the two receivers known as 'eyes'. The eyes focus the measured scattered field to form images which are processed by the 'wetware' of the brain for detection, identification, and localization. When time series representations of the measured scattered field are available, the image forming focusing process can be mathematically modeled by delayed, scaled, and summed migration. This concept of optical propagation, scattering, and focusing have one-to-one equivalents in the acoustic realm. This document is intended to present the basic concepts of scalar scattering and migration used in wide band wave-based remote sensing and imaging. The terms beamforming and (delayed, scaled, and summed) migration are used interchangeably but are to be distinguished from the narrow band (frequency domain) beamforming to determine the direction of arrival of a signal, and seismic migration in which wide band time series are shifted but not to form images per se. Section 3 presents a mostly graphically-based motivation and summary of delay, scale, and sum beamforming. The model for incident field propagation in free space is derived in Section 4 under specific assumptions. General object scattering is derived in Section 5 and simplified under the Born approximation in Section 6. The model of this section serves as the basis in the derivation of time-domain migration. The Foldy-Lax, full point scatterer scattering, method is derived in Section 7. With the previous forward models in hand, delay, scale, and sum beamforming is derived in Section 8. Finally, proof-of-principle experiments are present in Section 9.

42 ENGINEERING↗

Future Opportunities in Plasma Physics with FELs

I will discuss experiments to understand the nature of hot and dense matter using ultrafast x-ray pulses from synchrotrons and free electron lasers. The capabilities of these new light sources will allow greater understanding of the structure, bonding, and properties of these unique plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗