Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15) O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters) (Rev. 2)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Investigation on X-ray Reflectivity technique at LLNL

This report documents the work carried out to determine the feasibility of using this technique for Pu oxide grown on bulk Pu system. It also provides the experimental and theoretical considerations in carrying out XRR technique to determine film thicknesses. The intention of this work is to develop the methodology and understand the limits for carrying out such experiments using the in-house technique.

36 MATERIALS SCIENCE↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Redefining the U.S. Agenda for Nuclear Disarmament, Analysis and Reflections

With Lewis Dunn’s paper on nuclear disarmament diplomacy, we are inaugurating a new monograph series under the auspices of the Center for Global Security Research at Lawrence Livermore National Laboratory. The series will explore complex emerging challenges in the emerging security environment as they bear on issues of deterrence, assurance, and strategic stability. Our goal is to explore these issues deeply enough to provide significant new understanding that is technically informed and policy relevant. Our premise is that thoughtful students of international security affairs continue to value such in-depth analysis as a way to help make sense of the large flow of data and opinion that reaches all of us on a daily basis. Our ambition is to generate four to six such papers per year on especially salient topics. The views expressed in these papers are those of the author and should not be attributed to the Center, the Laboratory, or the U.S. government. This inaugural paper addresses one of the key questions facing national leadership seven to eight years after President Obama’s April 2009 remarks in Prague and his commitment to take practical steps towards the long-term goal of the elimination of nuclear weapons. In the interim, some important steps have been taken. But there have also been many disappointments. The new presidential administration will face a security landscape quite different from that of eight years ago and must reassess U.S. priorities and approaches. As Lewis Dunn argues, some will be tempted to walk away entirely from the disarmament agenda, while others will advocate even more forcefully for unilateral U.S. steps to further reduce the role and number of nuclear weapons in its posture. Dr. Dunn sets out his own vision of how to adapt and carry forward the disarmament agenda, in a manner informed by developments in the security environment that point to a continuing role for nuclear deterrence. The result is both fresh and compelling.

99 GENERAL AND MISCELLANEOUS↗

Managing the Transition from Ally to Adversary: Reflections on an Earlier Era of U.S.-Russian Relations

At the end of World War II, the United States and the Soviet Union transformed from allies into adversaries and the Cold War began—a grim confrontation that lasted nearly half a century. After the Cold War, the U.S.–Russian relationship was by no means an alliance, but was relatively cooperative until the past few years. Under Russian president Vladimir Putin, a new chill has descended, and today there is talk that we are entering another Cold War. This essay examines an earlier era in U.S.–Russian affairs, when presidents Franklin Delano Roosevelt and Harry S. Truman managed America’s relationship with the Soviet Union, which essentially meant dealing with the Soviet premier, Joseph Stalin. The contents of that relationship—how it evolved, how it disintegrated, and how American leaders—reacted is the subject of this essay. Given the unsettled state of U.S.–Russian relations today and the many subplots that shape current policy, this paper makes no attempt to apply historical lessons to the management of contemporary problems; these are left for the reader to infer. Rather, we examine an earlier, though not necessarily simpler, era in which the U.S.– Russian relationship underwent dramatic change.

99 GENERAL AND MISCELLANEOUS↗

LiOH corrosion growth and thermal stability investigated by diffuse reflectance infrared Fourier Transform (DRIFT) spectroscopy

In this period, we have measured the kinetics of LiOH corrosion growth on LiH substrate at 35 ppm of moisture for over 2 months. The serial DRIFT spectra are being analyzed to build the growth kinetics for LiOH interfacial states, surface states, and bulk states. Physical chemistry insight is being employed to describe the observed parabolic-linear growth of the corrosion layer grown on LiH samples that have been previously vacuum baked then re-exposed to low moisture over a long time. The thermal stabilities of LiOH interfacial states, surface states, and bulk states are also being quantified by measuring the reduction in LiOH DRIFT signals as a function of vacuum level and temperature, and will be needed to add an on/off switch to the current outgassing modeling.

36 MATERIALS SCIENCE↗

Thrust #3: Simulation and Measurement of Bio-enabled Lensless Infrared Focusing and Spatially-Controlled Multiwavelength IR reflection

The path to quantitatively characterizing the possible impact of refractive index on the focusing behavior of C. Wailesii diatoms frustules and their replicas first required the careful design of a control experiment that allowed for judicious control of both material and hole pattern variables, which are thought to govern focusing behavior. This was accomplished by FIB-milling synthetic hole patterns with well-controlled dimensions into thin SiO 2 and MgO/Si films. In doing so, an ideal sample is obtained whose pore patterns can be simulated via beam propagation methods and whose relatively simple interference patterns can be measured by far-field diffraction imaging. Together with refractive index measurements via ellipsometry on SiO 2 and MgO/Si thin films, these results showed that the focusing distances at six different wavelengths over 550-1050 nm are strongly correlated with the dispersion of the refractive index in this range. Although assertions have been made to this point in the literature, the results given here presented an improved characterization of the role that refractive index played in focusing behavior in a “diatom-like” hole pattern that otherwise is missing in earlier works due to inadequate characterization of refractive index dispersion and poor control over hole pattern dimensions. These results provided a reference point with which measurements and simulations of diatoms and their replicas can be compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SBV: Characterization of Highly Reflective EUV Coatings (CRADA AWD00002394)

The overall goals were to support the development of new high efficiency EUV coatings which would dramatically reduce the energy needed in the semiconductor manufacturing lithography process as well as dramatically reducing the cost of future EUV lithography tools. The project was successful in the characterization of numerous samples generating many hundreds of datasets and critical feedback for the partner’s internal material development program.

36 MATERIALS SCIENCE↗

Q and A with the grandson of the Little Boy’s pilot: Brigadier General (retired) Paul Tibbets IV reflects on his family’s legacy military service

Paul Tibbets Jr., the pilot of the Enola Gay who released the Little Boy atomic bomb above Hiroshima, is part of a family with a legacy of military service. He was father to Paul Tibbets III, who served in the military as an Army reservist pharmacist and hospital administrator and eventually retired as a colonel. His son— grandson of Tibbets Jr.—is also Paul Tibbets. Paul Tibbets IV is a retired Air Force brigadier general and decorated bomber pilot. This legacy is not lost on his fellow airmen. They gave Tibbets IV the callsign “Nuke” early in his flying career. Tibbets IV flew the B-1 bomber and then the B-2 stealth bomber, a nuclear-capable, longrange strike aircraft. His 29 years of military service include combat missions in the Middle East, Afghanistan, and the Balkans—and a flight in a restored B-29 with his grandfather. In commemoration of the 75th anniversary of the atomic bombs and his grandfather’s historic role, Tibbets IV spoke with Los Alamos National Laboratory.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Reflections on Culture Work Planning and Metrics at SNL

The NNSA/SNL detail provided an NNSA safety professional a rare opportunity to immerse in the SNL documents, corporate guidance, local management and some processes as if I was an SNL employee. My detail was to identify opportunities for strengthening safety culture, especially as it relates to implementing engineered safety; seek site wide safety culture improvement opportunities; and to identify safety metric opportunities. To this regard, I was given wide latitude in studying and investigating how SNL functions, good access to many SNL websites. In an introductory letter from Division 4000's Catherine Green, she expressed the desire for all of SNL to openly share with me, thus making my collection of ideas about SNL more meaningful. I was able to talk with and learn from so many different SNL organizations and people including governance to custodial service; researchers, operation and safety; and, with all grades of employees especially mid-level center or organization managers. The ESH Coordinators were personally valuable in helping me see the big picture and understand some of the challenges. My hat is off to all those who volunteered to collaborate with me. One intent of this detail was to gain experience and knowledge so I could better perform my NNSA roles with greater awareness and understanding of SNL challenges and safety conditions. Without a doubt you at SNL have made this a reality. I appreciate the opportunity.

42 ENGINEERING↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Agile Strategy Living Laboratory Reflection Paper

Getting my team members to all agree that we needed to pursue possible solutions for our documentation review process was an idea that came across very well with the team. This specific topic has be something that as a team we have been having struggles with recently due to the shear amount of documents that have been flowing through the team’s hands to review. We all realized that the process had areas that we could change that would eliminate confusion for new employees, reduce backload, and improve efficiency and quality of the documentation reviews. The key personnel on our team that have the most direct control and impact over this process are the production control specialists, documentation preparation and review is their primary job function. They are denoted in the action pack as “doc spec 1” and this individual has 12 years of expertise in their role. The engineers are denoted as “engineer 1, 2, 3” respectively. Engineer 1 has 10 years of experience in this team, engineer 3 has 38 years of experience on the team, and engineer 2 is myself with 5 years of expertise with this team and 5 with the department of defense.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Slides]

The SCALE code package offers multiple nuclear data libraries supporting Monte Carlo transport, with sensitivity and uncertainty methods derived from MC transport solutions. Several libraries are multigroup, which introduce bias differing by system. Previous work has shown poor S/U results in several reflector materials: ICSBEP benchmark HMF-084 was selected to analyze biases and S/U method applicability to a variety of reflectors. Prior and ongoing work found inaccuracies in CSAS and TSUNAMI results, which were further investigated utilizing the HEU-MET-FAST-084 ICSBEP critical benchmark, chosen for its geometrical simplicity and variety of reflector materials. Perturbation of reflector thickness across various reflector materials allowed for an assortment of materials is to be tested swiftly for each sequence and method. Observation was an increasing bias of MG $k_{eff}$ relative to CE, in both direction and magnitude. IFP produced extremely reliable results. >85% of CLUTCH cases were found satisfactory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗