Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

An Evaluation of the Economic and Resilience Benefits of a Microgrid in Northampton, Massachusetts

Recent developments and advances in distributed energy resource (DER) technologies make them valuable assets in microgrids. This paper presents an innovative evaluation framework for microgrid assets to capture economic benefits from various grid and behind-the-meter services in grid-connecting mode and resilience benefits in islanding mode. In particular, a linear programming formulation is used to model different services and DER operational constraints to determine the optimal DER dispatch to maximize economic benefits. For the resiliency analysis, a stochastic evaluation procedure is proposed to explicitly quantify the microgrid survivability against a random outage, considering uncertainties associated with photovoltaic (PV) generation, system load, and distributed generator failures. Optimal coordination strategies are developed to minimize unserved energy and improve system survivability, considering different levels of system connectedness. The proposed framework has been applied to evaluate a proposed microgrid in Northampton, Massachusetts that would link the Northampton Department of Public Works, Cooley Dickenson Hospital, and Smith Vocational Area High School. The findings of this analysis indicate that over a 20-year economic life, a 441 kW/441 kWh battery energy storage system, and 386 kW PV solar array can generate $2.5 million in present value benefits, yielding a 1.16 return on investment ratio. Results of this study also show that forming a microgrid generally improves system survivability, but the resilience performance of individual facilities varies depending on power-sharing strategies.

25 ENERGY STORAGE↗

RF operation of AlN/Al 0.25 Ga 0.75 N/AlN HEMTs with f T /f max of 67/166 GHz

Abstract We report on highly-scaled Al 0.25 Ga 0.75 N channel high electron mobility transistors. Regrown ohmic contacts covering the sidewall of the compressively strained Al 0.25 Ga 0.75 N channel exhibited a low contact resistance ofR c = 0.23 Ω · mm. Scaled devices with a T-shaped gate showed record high speed for any AlGaN-based transistors,f T /f max = 67/166 GHz, while simultaneously achieving high average breakdown field exceeding 2 MV cm −1 . The load-pull measurements performed at 10 GHz revealed a 20% peak power added efficiency with an output power density of 2 W mm −1 , which is mainly limited by the RF dispersion.

Physics↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparisons of Nodal diffusion and whole-core transport methods for multiple cycles of a small Light water reacto

As part of a cooperative research and development agreement between the US department of Energy's Oak Ridge National Laboratory and Holtec International subsidiary SMR LLC, core simulator models of the SMR-160, a light water-cooled and -moderated, natural circulation, small modular reactor, were developed and compared. The model results indicate pin-by-pin power histories, critical boron concentration, and other key performance indicators useful for developing multi-cycle core loading patterns. One model uses industry standard nodal methods with a simple thermal-hydraulics solution, and the other uses an advanced deterministic neutronics solver with a coupled subchannel calculation. The goals of the comparison are to provide the reactor designer with a detailed and coupled core physics reference solution, inform the reactor designer of nodal model best practices based on the code-to-code comparison, and set up a workflow for performing subsequent detailed core simulator calculations. The results of this work will be used in the development of coupled neutronic, thermal hydraulic, and fuel performance models for advanced analysis of the SMR-160. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Introducing the Baseline Performance Reference (BPR) for Irradiance in PV System Applications

Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).

baseline performance reference↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Intern Deliverable Poster; Arc Flash Analysis; Landon Palmer

This poster describes what arc flash is, and what causes it. The importance of arc flash analysis is discussed, including what incident energy/working distance mean. SKM Power*Tools is discussed as a means for performing an arc flash analysis and breaker coordination. Arc flash warning labels are explained, including why it is important that up to date information is present with any changes made to an electrical system. An example arc flash label is described to give readers a better understanding of key components.

99 - GENERAL AND MISCELLANEOUS↗

Methodology for Estimating Performance and Cost of Natural Gas Combined Cycle Plants with Carbon Capture

This document describes a methodology that allows developers and evaluators to assess the status of developmental, natural gas combined cycle (NGCC) power plant post-combustion carbon dioxide (CO 2 ) separation technologies with respect to NETL performance and cost metrics. Developmental CO 2 separation technologies that might apply for NGCC post-combustion power generation can be placed into several categories, including, but not limited to membranes, solvents, sorbents, adsorbents, and phase-change technologies. The intent of this product is to provide a consistent methodology for high-level comparison of in-development technology to a standardized baseline.

20 FOSSIL-FUELED POWER PLANTS↗

Cooling and Timing Tests of the ATLAS Fast TracKer VME Boards

The Fast TracKer (FTK) is an ATLAS trigger upgrade built for full-event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The associative memory board (AMB) serial link processor and the auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the processing unit (PU), which finds tracks using hits from eight layers of the inner detector. The PU works in pipeline with the second stage board (SSB), which finds 12-layer tracks by adding extra hits to the identified tracks. In the designed configuration, 16 PUs and four SSBs are installed in a VME crate. The high power consumption of the AMB, AUX, and SSB (respectively, of about 250, 70, and 160 W per board) required the development of a custom cooling system. Even though the expected power consumption for each VME crate of the FTK system is high compared with a common VME setup, the 8 FTK core crates will use ≈60 kW, which is just a fraction of the power and the space needed for a CPU farm performing the same task. We report on the integration of 32 PUs and eight SSBs inside the FTK system, on the infrastructures needed to run and cool them, and on the tests performed to verify the system processing rate and the temperature stability at a safe value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ready for the Frontier: Preparing Applications for the World’s First Exascale System

Frontier, a supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), debuted atop the Top500 list of the world’s most powerful supercomputers in June 2022 as the very first computer to produce exascale performance. Making sure scientific applications are optimized on this architecture is the critical link necessary to translate the newly available computational power into scientific insight and solutions. To that goal, the OLCF developed the Center for Accelerated Application Readiness (CAAR) program to ensure that a suite of highly optimized applications is ready for scientific runs at the onset of production operations for Frontier. This paper describes our experience in porting and optimizing such suite of applications in the OLCF’s CAAR program.

Budiardja, Reuben↗

Resilient high-temperature reverse osmosis desalination membranes

Conventional thin-film composite (TFC) reverse osmosis (RO) membranes experience irreversible performance loss at high temperatures, restricting their use in industries with high-temperature streams, including oil and gas, pharmaceuticals, electronics, power generation, food production, and hybrid desalination plants. However, the mechanisms driving the performance decline of TFC membranes at high temperatures remain poorly understood. Herein, we combine controlled experiments, molecular dynamics simulations, and micromechanical modeling to elucidate TFC failure mechanisms and to evaluate thermally resilient thin-film cross-linked (TFX) composite membrane. Upon exposure to elevated temperatures (>60°C), salt rejection of TFC dropped from ~99 to <90%, with irreversible structural damage in the polysulfone layer, confirmed by scanning electron microscopy. In contrast, the TFX membrane maintained ~99% salt rejection and showed no signs of physical degradation up to 80°C. Our combined analyses revealed that TFC membrane failure arises from irreversible pore expansion in the thermoplastic polysulfone support, leading to polyamide film rupture and delamination. TFX membranes resist thermal deformation, enabling ultrahigh-temperature RO desalination and water reuse.

Wu, Jishan [Rice Univ., Houston, TX (United States↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Comparison of Linear and Rotary Electric Machine Topologies for a Hybrid Hydraulic Electric Architecture of Off-Highway Vehicles

Electrification of off-highway vehicles offers the benefits of improved energy efficiency, enhanced controllability, and reduction in greenhouse gas emissions. However, progress towards electrification has been limited by the low power density of electric components compared to hydraulic components. A recently proposed hybrid hydraulic electric vehicle architecture provides a potential solution to these power density challenges by minimizing the required power rating of the electric components. This paper investigates the optimal design of linear and rotary electric machines for this new system architecture. Key performance metrics are identified for the electric machine, several variants of electric machines are analytically sized and compared for two different power levels, and an FEA-assisted design optimization is performed on promising candidates. Based on the optimization results, it is shown that an axial flux rotary machine is most suitable for implements requiring high power ratings, while the linear machine's form factor makes it a compelling candidate for lower power implements.

42 ENGINEERING↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Model Predictive Control of Dual-Mode Energy-Stored Quasi-Z-Source Photovoltaic System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations and other advantages of Z-source inverter. Traditional ES-qZSI suffers from poor operation at night or cloudy days when PV power is extremely low. In order to overcome that, this paper proposes a model predictive control (MPC) strategy for an improved dual-mode ES-qZSI, which is designed to support all-weather operation of PV power generation system. The system predictive models in both day and night operating modes are derived. And the control strategy based on MPC is disclosed to ensure the high-performance operation of the system. Simulation is carried out on PV power fluctuation in daytime and switching between the two modes, to verify the effectiveness of proposed control strategy.

Xue, Yaosuo↗

Resilience Assessment Framework For Electric Distribution Systems Performance Under Extreme Conditions

The devastating impact of extreme weather-related events is increasingly evident on power grids, especially on distribution grids. The severity of their potential impact calls for 1) developing a suitable resilience assessment framework to capture the system performance and 2) assessing relevant mitigative strategies to lessen the impact of such events. This paper proposes a framework to identify grid vulnerabilities using the energy-at-risk concept to select, disconnect and isolate grid portions due to a resilience event. The proposed framework mainly consists of two steps; i) processing the utility's available infrastructure, i.e., a network model, possible switching combinations, and outage information for those combinations, as a graph-based database, and ii) implementing a novel optimal switching algorithm leveraging database and grid simulated metrics. These switching actions are generated to implement load curtailment in a rolling manner during anticipated grid scarcity conditions. In this study, a test case is created using two taxonomy feeders and is simulated against an extreme temperature event, e.g., a long, relatively cold, and prolonged freeze peak, thereby creating stress on the grid. It is demonstrated that the proposed framework allows utilities to predict the energy-at-risk during such resilience events and design suitable outage management strategies.

Poudel, Shiva↗