Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Multichannel microwave interferometer with an antenna switching system for electron density measurement in a laboratory plasma experiment

This study presents a simple and powerful technique for multichannel measurements of the density profile in laboratory plasmas by microwave interferometry. This technique uses electromechanical microwave switches to temporally switch the connection between multiple receiver antennas and one phase-detection circuit. Using this method, the phase information detected at different positions is rearranged into a time series that can be acquired from a minimum number of data acquisition channels (e.g., two channels in the case of quadrature detection). Our successfully developed multichannel microwave interferometer that uses the antenna switching method was applied to measure the radial electron density profiles in a magnetized plasma experiment. The advantage of the proposed method is its compactness and scalability to multidimensional measurement systems at low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface magnetism in Fe 3 GeTe 2 van der Waals ferromagnet

The surface magnetization of Fe 3 GeTe 2 was examined by low-energy electron microscopy (LEEM) using an off-normal incidence electron beam. We found that the 180o domain walls are of Bloch type. Temperature-dependent LEEM measurements yield a surface magnetization with a surface critical exponent β1 = 0.79±0.02. This result is consistent with surface magnetism in the 3D semi-infinite Heisenberg (β1 = 0.84±0.01) or Ising (β1 = 0.78±0.02) models, which is distinctly different from the bulk exponent (β = 0.34±0.07). Further, the measurements reveal the power of LEEM with a tilted beam to determine magnetic domain structure in quantum materials, without need for the use of spin-polarized electrons. Single crystal diffraction measurements reveal inversion symmetry-breaking weak peaks and yield space group P-6m2. This Fe site defect-derived loss of inversion symmetry enables the formation of skyrmions in this Fe 3 GeTe 2 crystal.

36 MATERIALS SCIENCE↗

Effect of bias application to plasma density in weakly magnetized inductively coupled plasma

Independent control of the ion flux and energy can be achieved in a dual frequency inductively coupled plasma (ICP) system. Typically, the plasma density is controlled by the high-frequency antenna radio-frequency (RF) power and the ion energy is controlled by the low-frequency bias RF power. Increasing the bias power has been known to cause a decrease in the plasma density in capacitively coupled discharge systems as well as in ICP systems. However, an applied axial magnetic field was found to sustain or increase the plasma density as bias power is increased. Measurements show higher electron temperatures but lower plasma densities are obtained in ordinary ICP systems than in magnetized ICP systems under the same neutral gas pressure and RF power levels. Explanations for the difference in the behavior of plasma density with increasing bias power are given in terms of the difference in the heating mechanism in ordinary unmagnetized and magnetized ICP systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observations of solar-flare ionization in the mesosphere using coherent-scatter radar

Observations of solar-flare ionization in the mesosphere can be made using coherent-scatter radar systems. The scattered power profiles they measure in the 60-90 km altitude region is a function of the ion concentration gradient and the intensity of turbulent mixing at each altitude. By comparing the power profiles before, during and after a solar flare, it is possible to estimate the ion production rate during the flare as a function of altitude and time. This analysis is used to compare the ion production rates with generally accepted ion-chemical models. Comparisons are made with ion production rates estimated from the solar X-ray flux for the same flare made by geostationary satellites.

Parker, J. W.↗

Optical measurements pertaining to Space Station solar dynamic power systems

The Space Station solar dynamic power system is a hybrid of solar photovoltaic and solar dynamic systems, the latter of which uses a parabolic reflector to collect solar energy. This paper describes analytical results of an off-axis solar illumination on the intensity distribution in arbitrary target planes perpendicular to the axis of a parabolic reflector. Such computational capability would make it possible to predict optical intensity distributions resulting from off-axis angles of incident radiation on such target planes. To validate the computer code, experimental optical measurements were performed on the multifaceted paraboloidal collecor at the Solar Dynamic Test Facility at Rockedyne's Santa Susana Field Laboratory. The experimental data compared reasonably well with the calculated values.

Holly, S.↗

Resolving broadening of ECRH deposition due to edge turbulence in DIII-D by heat deposition measurement

Interaction between microwave power, used for local heating and mode control, and density fluctuations can produce a broadening of the injected beam, as confirmed in experiment and simulation. Increased power deposition width could impact suppression of tearing mode structures on ITER[1]. This work discusses the experimental portion of an effort to understand scattering of injected microwaves by turbulence on the DIII-D tokamak. The corresponding theoretical modeling work can be found in M.B. Thomas et. al.: Submitted to Nuclear Fusion (2017)[Author Note - this paper to be published in same journal]. In a set of perturbative heat transport experiments, tokamak edge millimeter-scale fluctuation levels and microwave heat deposition are measured simultaneously. Beam broadening is separated from heat transport through fitting of modulated fluxes[2]. Electron temperature measurements from a 500 kHz, 48-channel ECE radiometer are Fourier analyzed and used to calculate a deposition-dependent flux[3]. Consistency of this flux with a transport model is evaluated. A diffusive(∝ ∇˜ T e ) and convective(∝ ˜ T e ) transport solution is linearized and compared with energy conservation-derived fluxes. Comparison between these two forms of heat flux is used to evaluate the quality of ECRF deposition profiles, and a Χ 2 minimization finds a significant broadening of 1D equilibrium ray tracing calculations from the benchmarked TORAY-GA ray tracing code[4] is needed. The physical basis, cross-validation, and application of the heat flux method is presented. The method is applied to a range of DIII-D discharges and finds a broadening factor of the deposition profile width which scales linearly with edge density fluctuation level. Furthermore, these experimental results are found to be consistent with the full-wave beam broadening measured by the 3D full wave simulations in the same discharges[5].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANGULAR POWER SPECTRA OF THE MILLIMETER-WAVELENGTH BACKGROUND LIGHT FROM DUSTY STAR-FORMING GALAXIES WITH THE SOUTH POLE TELESCOPE

We use data from the first 100 deg{sup 2} field observed by the South Pole Telescope (SPT) in 2008 to measure the angular power spectrum of temperature anisotropies contributed by the background of dusty star-forming galaxies (DSFGs) at millimeter wavelengths. From the auto- and cross-correlation of 150 and 220 GHz SPT maps, we significantly detect both Poisson distributed and, for the first time at millimeter wavelengths, clustered components of power from a background of DSFGs. The spectral indices of the Poisson and clustered components are found to be {alpha}-bar{sup P}{sub 150-220}=3.86{+-}0.23 and {alpha} {sup C}{sub 150-220} = 3.8 {+-} 1.3, implying a steep scaling of the dust emissivity index {beta} {approx} 2. The Poisson and clustered power detected in SPT, BLAST (at 600, 860, and 1200 GHz), and Spitzer (1900 GHz) data can be understood in the context of a simple model in which all galaxies have the same graybody spectrum with dust emissivity index of {beta} = 2 and dust temperature T{sub d} = 34 K. In this model, half of the 150 GHz background light comes from redshifts greater than 3.2. We also use the SPT data to place an upper limit on the amplitude of the kinetic Sunyaev-Zel'dovich power spectrum at l = 3000 of 13 {mu}K{sup 2} at 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Electro-optical equivalent calibration technology for high-energy laser energy meters

Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Quantifying the Effect of Lidar Turbulence Error on Wind Power Prediction

Currently, cup anemometers on meteorological towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability; however, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install meteorological towers at potential sites. As a result, remote-sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. Although lidars can accurately estimate mean wind speeds and wind directions, there is still a large amount of uncertainty surrounding the measurement of turbulence using these devices. Errors in lidar turbulence estimates are caused by a variety of factors, including instrument noise, volume averaging, and variance contamination, in which the magnitude of these factors is highly dependent on measurement height and atmospheric stability. As turbulence has a large impact on wind power production, errors in turbulence measurements will translate into errors in wind power prediction. The impact of using lidars rather than cup anemometers for wind power prediction must be understood if lidars are to be considered a viable alternative to cup anemometers.In this poster, the sensitivity of power prediction error to typical lidar turbulence measurement errors is assessed. Turbulence estimates from a vertically profiling WINDCUBE v2 lidar are compared to high-resolution sonic anemometer measurements at field sites in Oklahoma and Colorado to determine the degree of lidar turbulence error that can be expected under different atmospheric conditions. These errors are then incorporated into a power prediction model to estimate the sensitivity of power prediction error to turbulence measurement error. Power prediction models, including the standard binning method and a random forest method, were developed using data from the aeroelastic simulator FAST for a 1.5 MW turbine. The impact of lidar turbulence error on the predicted power from these different models is examined to determine the degree of turbulence measurement accuracy needed for accurate power prediction.

17 WIND ENERGY↗

Thermal radiation of laser heated niobium clusters Nb{sub N}{sup +}, 8 ⩽ N ⩽ 22

The thermal radiation from small, laser heated, positively charged niobium clusters has been measured. The emitted power was determined by the quenching effect on the metastable decay, employing two different experimental protocols. The radiative power decreases slightly with cluster size and shows no strong size-to-size variations. The magnitude is 40–50 keV/s at the timescale of several microseconds, which is the measured crossover time from evaporative to radiative cooling.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution setup for measuring wavelength sensitivity of photoyellowing of translucent materials

Polystyrene and many other materials turn yellow when exposed to ultraviolet (UV) radiation. All photodegradation mechanisms including photoyellowing are functions of the exposure wavelength, which can be described with an action spectrum. In this work, a new high-resolution transmittance measurement setup based on lasers has been developed for measuring color changes, such as the photoyellowing of translucent materials aged with a spectrograph. The measurement setup includes 14 power-stabilized laser lines between 325 nm and 933 nm wavelengths, of which one at a time is directed on to the aged sample. The power transmitted through the sample is measured with a silicon detector utilizing an integrating sphere. The sample is mounted on a high-resolution XY translation stage. Measurement at various locations aged with different wavelengths of exposure radiation gives the transmittance data required for acquiring the action spectrum. The combination of a UV spectrograph and the new high-resolution transmittance measurement setup enables a novel method for studying the UV-induced ageing of translucent materials with a spectral resolution of 3–8 nm, limited by the adjustable spectral bandwidth range of the spectrograph. These achievements form a significant improvement over earlier methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bias of damped Lyman-α systems from their cross-correlation with CMB lensing

We cross-correlate the positions of damped Lyman-α systems (DLAs) and their parent quasar catalog with a convergence map derived from the Planck cosmic microwave background (CMB) temperature data. We then make consistent measurements of the lensing signal of both samples in both Fourier and configuration space. By interpreting the excess signal present in the DLA catalog with respect to the parent quasar catalog as caused by the large scale structure traced by DLAs, we are able to infer the bias of these objects: b DLA =2.6±0.9. These results are consistent with previous measurements made in cross-correlation with the Lyman-α forest, although the current noise in the lensing data and the low number density of DLAs limits the constraining power of this measurement. We discuss the robustness of the analysis with respect to a number different systematic effects and forecast prospects of carrying out this measurement with data from future experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

We report an in situ measurement of the electric field attenuation length Lα at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be < L α > = 947$^{+92}_{–85}$ m at 75 MHz. Here, while this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for the detection of ultra-high energy (UHE) astrophysical particles via their radio emission in dielectric media such as ice. Assuming a reliable extrapolation to higher frequencies, the measured attenuation length at Summit Station is comparable to previously measured radio-frequency attenuation lengths at candidate particle detector sites around the world, and strengthens the case for Summit Station as a promising northern site for UHE neutrino detection.

54 ENVIRONMENTAL SCIENCES↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal transitions in semi-crystalline polymer thin films studied via spectral reflectance

Herein we report the finding that spectral reflectance (SR) can be used to identify thermal transitions in semi-crystalline polymer thin films. By studying film thickness as a function of temperature, we found that semi-crystalline polymers exhibit characteristic expansion and contraction profiles during the melting (T m ) and crystallization (T c ) transitions, respectively. Prior to this discovery, studies on the crystalline T m in thin films have involved more expensive and complex techniques such as atomic force microscopy (AFM), ellipsometry, and grazing-incidence wide-angle X-ray scattering (GIWAXS). We correlate T m and T c as measured by SR with differential scanning calorimetry (DSC) in the bulk and temperature-controlled GIWAXS or AFM in thin films. We show that SR is accurate for measuring changes in films with thicknesses of 500 nm down to 21 nm and for detecting melting point depression due to thin film confinement. Furthermore, we demonstrate that SR is a powerful tool for measuring thermal transitions in semi-crystalline polymer films with single-degree resolution.

36 MATERIALS SCIENCE↗