Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polyethylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Characterization of CO 2 flux through hollow-fiber membranes using pH modeling

CO 2 must be delivered efficiently during large-scale microalgal cultivation. Bubbleless mass-transfer via diffusion through hollow-fiber membranes (HFM) can achieve much higher CO 2 -transfer efficiency than traditional sparging systems. Here this study developed and used a model to compute accurate values for the CO 2 flux (J CO 2 ), overall mass-transfer coefficient (K L ), and overall volumetric mass-transfer coefficient (K L a) based on the rate of change of pH in batch experiments. A composite HFM comprised of two macroporous polyethylene layers and a nonporous polyurethane layer was tested for CO 2 transfer to a sodium carbonate solution using a range of total pressures, inlet CO 2 concentrations, and open-end versus closed-end modes of operation. The model accurately computed J CO2 and K L a for pH values above 8. Key trends are that (i) JCO2 and KLa increased with increasing average inlet CO 2 partial pressure; (ii) open-end HFMs performed better than closed-end HFMs when the supplied CO 2 was less than 100%; and (iii) the available membrane area used for CO 2 mass-transfer decreased as the inlet CO 2 partial pressure decreased due to depletion of CO 2 inside the membrane, especially for closed-end HFMs, since inert gases could not be vented.

42 ENGINEERING↗

Cation–polymer interactions and local heterogeneity determine the relative order of alkali cation diffusion coefficients in PEGDA hydrogels

Current research efforts are focused on endowing polymer membranes with ion–ion selectivity by incorporating ion–polymer interactions into materials to bias the selective partitioning and or diffusivity of one species over another. However, little is known about the impact of such interactions on the mechanisms of ion transport. In this study, we probe the influence of cation–polymer interactions on cation, anion, and salt diffusivity in a model membrane material, poly(ethylene glycol) diacrylate (PEGDA) by modeling concentrated polyethylene oxide solutions via molecular dynamics simulations. These results are compared to published experimental data for LiCl, NaCl, and KCl diffusion in PEGDA. Experimentally, the order of salt and cation diffusion coefficients for LiCl, NaCl, and KCl deviate from the order in aqueous solutions. Here, simulations identify these deviations to arise from cation–polymer coordination in the membrane. Both the fraction of bound cations and the average binding lifetime increases with decreasing cation hydration free energy (moving down the alkali series), leading to different diffusivity trends in the membrane compared to solution. However, to recover the experimentally observed order of diffusivities cations and salt in our simulations, we needed to incorporate membrane heterogeneity explicitly via a polymer charge scaling procedure. Together, our results indicate that cation–polymer interactions, as well as spatial heterogeneity within the membrane, play a critical role in dictating the observed order of alkali cation and salt diffusion coefficients in membranes.

36 MATERIALS SCIENCE↗

Insights into determining pore size properties of ultrafiltration membranes

The selectivity of porous membranes is often characterized using solute rejection tests, where membranes are challenged with dilute aqueous solutions of neutral solutes at operating conditions that minimize concentration polarization and fouling. In single solute tests, a membrane is challenged with one molecular weight (MW) solute at a time from low to high MW. Since single solute methods are time-intensive, mixed solute tests have become more common, where a mixture of several MW solutes challenges a membrane at once. However, the presence of large solutes in a mixture increases the rejection of smaller solutes. Furthermore, there are no universally accepted operating conditions or standard methods used by membrane manufacturers or researchers for the experiments, leading to difficulty in pore size and pore characteristic comparisons. In this paper, commercial ultrafiltration membranes were challenged with single and mixed solute polyethylene glycol (PEG) and dextran aqueous solutions. First, rejection values determined using total organic carbon (TOC) and high-performance liquid chromatography (HPLC) from single solute filtration experiments are compared. Differences in rejection curves obtained by the two techniques are attributed to solute polydispersity. Mixed solute filtration experiments with binary mixtures of solutes showcased co-solute interactions, which increase with both the size and weight percent of large solute in the mixture. Mixed solute filtration experiments at varying operating conditions (i.e., stir speed and flux) were conducted to determine operating conditions that mitigate co-solute interactions. Stir speed had a minimal effect on co-solute interactions. In contrast, low flux conditions can help minimize co-solute interactions, leading to pore size distributions that closely resemble results observed in single solute filtration using narrowly dispersed solutes. Additionally, at low flux conditions, the predicted membrane pore size distributions utilizing mixed solute experiments with PEG and dextran were similar.

36 MATERIALS SCIENCE↗

Optimizing processing conditions for additively reinforced thermoforming (ART) in convergent manufacturing

This study utilized additively reinforced thermoforming (ART) to enhance the thermomechanical properties of polyethylene terephthalate glycol (PETG) sheet. ART materials were produced by overprinting PETG/carbon fiber filament (PETG/CF) on neat PETG sheets at varying conditions. The mechanical properties of the PETG sheet, PETG/CF, and ART materials were assessed, showing that ART exhibited superior tensile strength and modulus of elasticity. The tensile strength and modulus in the x-direction for ART at 265°C were 57.32 ± 2.9 MPa and 3.41 ± 0.4 GPa, respectively, compared to 49.1 ± 0.5 MPa and 1.92 ± 0.09 GPa for neat PETG. Microstructural analysis revealed strong interfacial adhesion between layers, while thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and heat deflection temperature analysis provided insights into the ART material's thermoforming behavior, aiding design optimization for enhanced stiffness, reduced necking, and improved customization. In conclusion, this information can be used to design for the thermoforming operation.

Additive reinforcement↗

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

Porous artificial bone scaffold synthesized from a facile in situ hydroxyapatite coating and crosslinking reaction of crystalline nanocellulose

Research into artificial bone scaffolds has increased substantially over the past decade as current solutions have significant limitations. Inspired by mineral hydroxyapatite (HAP) in natural bone, this study developed a facile in situ HAP coating on cellulose nanocrystals (CNCs) matrix followed by a crosslinking reaction. By changing the amount of CNCs added to a simulated body fluid (SBF), HAP content in the nanocomposite could be controlled between 0 and 40.1%, with a HAP coating thickness of ~10 nm. Moreover, CNCs/HAP was crosslinked with poly(methyl vinyl ether-alt-maleic acid) (PMVEMA) and polyethylene glycol (PEG) to enhance its water stability and mechanical properties. FTIR and NMR analysis revealed that crosslinking happened via an esterification reaction between CNCs, HAP, PMVEMA, and PEG. Compression strength of the scaffolds showed a result as high as 41.8 MPa, almost 20 times of scaffold prepared by just mixing CNCs and HAP. Further investigations revealed that this scaffold was highly porous (as high as 91.0%) and lightweight (with a density between 60-70 mg/cm 3 ). In addition, this composite showed good biocompatibility as it can stabilize BSA protein, suggesting a promising material as a bone scaffold.

60 APPLIED LIFE SCIENCES↗

Striking luminescence phenomena of carbon dots and their applications as a double ratiometric fluorescence probes for H2S detection

Here, we report some new observations on the luminescence of carbon dots (CDs) that are passivated with polyethylene glycol, and explored them, for the first time, as highly sensitive H2S detection probe. The as-prepared CDs have an ultraviolet (UV) emission at 350 nm and a green emission at 540 nm when excited at 270 nm, but they have only a green emission at 523 nm when excited at 365 nm. As Na2S is added to the CDs, the UV emission decreases gradually, while the green emission increases slightly, and interestingly a new emission appears at 455 nm is increased linearly in intensity with the increase of Na2S concentration. The blue emission at 455 nm is from the intrinsic core of CDs, and the green emissions at 540 or 523 nm are from their surface states, while the UV emission at 350 nm is from the anchored PEG. Both the emission intensity ratios of F-450/F-350 and F-455/F-523 show an excellent linear relationship with the Na2S concentration in the range of 0-800 mu M, and the detection limit estimated from both of them is approximately 7.0 nM, indicating our method is the most sensitive H2S CDs based detection method reported thus far. Furthermore, the detection was tested successfully for H2S imaging in live cells. We propose that the interactions of H2S with the CDs and the anchored ligands, as well as the energy transfer between the ligands and the CDs, are responsible for the luminescence responses for H2S detection. Our studies enrich the world of carbon dots with plenty of potential applications. (C) 2020 Elsevier Ltd. All rights reserved.

Bioimaging↗

Thermally conductive separator with hierarchical nano/microstructures for improving thermal management of batteries

Thermal management is critical to improving battery performance and suppressing thermal runaway. Besides developing external cooling technologies, it is important to understand and control thermal transport inside batteries. Heat transfer inside batteries is first analyzed and the thermal conductivity of each component is measured. The results show that low thermal conductivity of the separator is one major barrier for heat transfer in Li-ion batteries. To improve thermal conductivity of the separator, a hierarchical nano/micro-Al 2 O 3 /polymer separator is prepared with thermal conductivity of ~1 W m -1 K -1 , representing an enhancement of 5× compared to commercial polyethylene-based separators. Modeling has been performed to understand mechanism behind the enhancement of thermal conductivity, which suggests that addition of nanoparticles significantly reduces thickness of polymer coating on micron-sized Al 2 O 3 particles and thus increase the thermal conductivity of the composite separator. This Al 2 O 3 -based separator also has similar ionic conductivity with commercial polymer separators. Such composite separator may have potential applications in developing batteries with better performance and safety.

25 ENERGY STORAGE↗

Benchmarking ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1 with MCNP6

Recent releases of three major world nuclear reaction data libraries, ENDF/B-VII.1, JENDL-4.0, and JEFF-3.1.1, have been tested extensively using benchmark calculations. The calculations were performed with the latest release of the continuous energy Monte Carlo neutronics code MCNP, i.e. MCNP6. Three types of benchmarks were used, viz. criticality safety benchmarks, (fusion) shielding benchmarks, and reference systems for which the effective delayed neutron fraction is reported. For criticality safety, more than 2000 benchmarks from the International Handbook of Criticality Safety Benchmark Experiments were used. Benchmarks from all categories were used, ranging from low-enriched uranium, compound fuel, thermal spectrum ones (LEU-COMP-THERM), to mixed uranium-plutonium, metallic fuel, fast spectrum ones (MIX-MET-FAST). For fusion shielding many benchmarks were based on IAEA specifications for the Oktavian experiments (for Al, Co, Cr, Cu, LiF, Mn, Mo, Si, Ti, W, Zr), Fusion Neutronics Source in Japan (for Be, C, N, O, Fe, Pb), and Pulsed Sphere experiments at Lawrence Livermore National Laboratory (for {sup 6}Li, {sup 7}Li, Be, C, N, O, Mg, Al, Ti, Fe, Pb, D2O, H2O, concrete, polyethylene and teflon). The new functionality in MCNP6 to calculate the effective delayed neutron fraction was tested by comparison with more than thirty measurements in widely varying systems. Among these were measurements in the Tank Critical Assembly (TCA in Japan) and IPEN/MB-01 (Brazil), both with a thermal spectrum, two cores in Masurca (France) and three cores in the Fast Critical Assembly (FCA, Japan), all with fast spectra. The performance of the three libraries, in combination with MCNP6, is shown to be good. The results for the LEU-COMP-THERM category are on average very close to the benchmark value. Also for most other categories the results are satisfactory. Deviations from the benchmark values do occur in certain benchmark series, or in isolated cases within benchmark series. Such instances can often be related to nuclear data for specific non-fissile elements, such as C, Fe, or Gd. Indications are that the intermediate and mixed spectrum cases are less well described. The results for the shielding benchmarks are generally good, with very similar results for the three libraries in the majority of cases. Nevertheless there are, in certain cases, strong deviations between calculated and benchmark values, such as for Co and Mg. Also, the results show discrepancies at certain energies or angles for e.g. C, N, O, Mo, and W. The functionality of MCNP6 to calculate the effective delayed neutron fraction yields very good results for all three libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements and simulations of the cosmic-ray-induced neutron background

The cosmic-ray-induced neutron background at ground level has been measured and simulated in conjunction with EJ-309 organic liquid scintillators with an approximate deposited energy range of 0.5–6 MeV. Specifically, the pulse height distributions, net neutron count rates, and angular dependences were obtained. The simulations were carried out using the Monte Carlo transport code MCNPX-PoliMi combined with the (Cosmic-Ray Shower Generator) CRY source subroutine that returns secondary particles produced by cosmic rays. A scaling formula from literature was also implemented in the simulation. The angular dependence of the neutron count rate was measured by collimating the liquid scintillator with polyethylene to attain 18° angular resolution from 0° downwards to 72° horizontally. The neutron count rate was measured to be 23.10±1.69 h -1 sr -1 at 0°, and 7.20±0.78 h -1 sr -1 at 72°. The simulations and measurements compare well and show similar cosine anisotropy for the angular distribution. Finally, the study thus shows that the neutron background response in detector systems can be efficiently and accurately simulated using the procedures described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Introducing single-crystal scattering and optical potentials into MCNPX: Predicting neutron emission from a convoluted moderator

Neutron transport simulation codes are an indispensable tool used for the design and construction of modern neutron scattering facilities and instrumentation. It has become increasingly clear that some neutron instrumentation has started to exploit physics that is not well-modelled by the existing codes. Particularly, the transport of neutrons through single crystals and across interfaces in MCNP(X), Geant4 and other codes ignores scattering from oriented crystals and refractive effects, and yet these are essential ingredients for the performance of monochromators and ultra-cold neutron transport respectively (to mention but two examples). In light of these developments, we have extended the MCNPX code to include a single-crystal neutron scattering model and neutron reflection/refraction physics. Furthermore, we have also generated silicon scattering kernels for single crystals of definable orientation with respect to an incoming neutron beam. As a first test of these new tools, we have chosen to model the recently developed convoluted moderator concept, in which a moderating material is interleaved with layers of perfect crystals to provide an exit path for neutrons moderated to energies below the crystal s Bragg cut off at locations deep within the moderator. Studies of simple cylindrical convoluted moderator systems of 100 mm diameter and composed of polyethylene and single crystal silicon were performed with the upgraded MCNPX code and reproduced the magnitude of effects seen in experiments compared to homogeneous moderator systems. Applying different material properties for refraction and reflection, and by replacing the silicon in the models with voids, we show that the emission enhancements seen in recent experiments are primarily caused by the transparency of the silicon/void layers. Finally the convoluted moderator experiments described by Iverson et al. were simulated and we find satisfactory agreement between the measurement and the results of simulations performed using the tools we have developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-resolution gamma-ray spectrometry for an information barrier based on a multi-criteria template-matching approach

Gamma-ray spectrometry has been successfully employed to identify unique items containing special nuclear materials. Template information barriers have been developed in the past to confirm items as warheads by comparing their gamma signature to the signature of true warheads. Their development has, however, not been fully transparent, and they may not be sensitive to some relevant evasion scenarios. Here, we develop a fully open template information barrier concept, based on low-resolution measurements, which, by design, reduces the extent of revealed sensitive information. The concept is based on three signatures of an item to be compared to a recorded template. The similarity of the spectrum is assessed by a modification of the Kolmogorov–Smirnov test to confirm the isotopic composition. The total gamma count rate must agree with the template as a measure of the projected surface of the object. In order to detect the diversion of fissile material from the interior of an item, a polyethylene mask is placed in front of the detector. Neutrons from spontaneous and induced fission events in the item produce 2.223 MeV gamma rays from neutron capture by hydrogen-1 in the mask. This peak is detected and its intensity scales with the item's fissile mass. This analysis is based on MCNP Monte Carlo simulations of various plutonium configurations suggests that this concept can distinguish a valid item from a variety of invalid ones. The concept intentionally avoids any assumptions about specific spectral features, such as looking for specific gamma peaks of specific isotopes, thereby facilitating a fully unclassified discussion. Finally, by making all aspects public and allowing interested participants to contribute to the development and benchmarking, we enable a more open and inclusive discourse on this matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Here, we present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a neutron spectrometer utilizing rubberized Eu:LiCAF wafers

A portable ten-layer neutron spectrometer has been developed using a novel material, LiCAF. The spectrometer consists of rubber matrix wafers with embedded europium doped lithium calcium aluminum uoride (Eu:LiCAF) crystals and crosshatched wave shifting fibers (WSF). Layers of high density polyethylene (HDPE) separating each Eu:LiCAF wafer serve as neutron moderating material. Neutrons entering the spec- trometer react in the Eu:LiCAF crystal, creating scintillation photons. The photons travel down the WSFs to silicon photomultipliers (SiPMs) that convert the photons to an electrical signal. Custom electronics are used to gather, amplify, process, and readout the signal. A library of several neutron response curves was created in Geant4 and MCNP. The experimental output of the spectrometer was unfolded using a maximum entropy algorithm, MAXED. The spectrometer was tested using two separate DD generators. These two tests resulted in unfolded neutron spectra with average neutron energies of 2.71 and 2.78 MeV and chi-squared values of 0.88 and 1.51 χ 2 /D.O.F. respectively, when fit to a 2.45 MeV monoenergetic energy spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of degradation and encapsulation of plastic scintillator

Studies have revealed that plastic scintillators such as polyvinyl toluene and polystyrene can undergo environmentally related material damage (“fogging”) that adversely affects detection performance under certain conditions and histories. A significant decrease in sensitivity has been seen in some gamma-ray detectors as they age as a result of this damage. Performance degradation due to such damage is characterized by a signal change from the detector, which shifts to lower energy, and ultimately a reduction in the ability to detect gamma radiation. This degradation is due to the permeation of water into the plastic, which can then cause temporary fogging and permanent damage to the material. As an example, a 1-mm thick barrier of high-density polyethylene with an area of 1 m 2 would allow 5 g per year of water transmission at 100% relative humidity. Thus, significant amounts of water can penetrate plastics over time and provide the potential for damage to the plastic. Such damage to plastic scintillator can cause problems for radiation detection applications in uncontrolled environments. Mitigation approaches that have been proposed to prevent damage to plastic scintillator include encapsulation of the plastic scintillator to prevent water intrusion that leads to damage during cold cycles. It is concluded that an encapsulation material with a moisture vapor transmission rate on the order of 10 -4 g∙m -2 ∙d -1 or better is needed for protecting large pieces of plastic scintillator from fogging over years of use. This article presents information on testing of bare and encapsulated plastic scintillator samples and on diagnostic approaches to measure the nature and progression of the fogging condition. It is shown that several encapsulation approaches fail to prevent water intrusion, while a couple methods can successfully encapsulate plastic and prevent water from penetrating the plastic and producing fogging.

36 MATERIALS SCIENCE↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗