Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Independent Review of AFC 2A, 2B, and 2E ATR Irradiation Tests

As part of the Department of Energy Advanced Fuel Cycle program, a series of fuels development irradiation tests have been performed in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. These tests are providing excellent data for advanced fuels development. The program is focused on the transmutation of higher actinides which best can be accomplished in a sodium-cooled fast reactor. Because a fast test reactor is no longer available in the US, a special test vehicle is used to achieve near-prototypic fast reactor conditions (neutron spectra and temperature) for use in ATR (a water-cooled thermal reactor). As part of the testing program, there were many successful tests of advanced fuels including metals and ceramics. Recently however, there have been three experimental campaigns using metal fuels that experienced failure during irradiation. At the request of the program, an independent review committee was convened to review the post-test analyses performed by the fuels development team, to assess the conclusions of the team for the cause of the failures, to assess the adequacy and completeness of the analyses, to identify issues that were missed, and to make recommendations for improvements in the design and operation of future tests. Although there is some difference of opinion, the review committee largely agreed with the conclusions of the fuel development team regarding the cause of the failures. For the most part, the analyses that support the conclusions are sufficient.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High rate performances of the cathode material LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} synthesized using low temperature hydroxide precipitation

Graphical abstract: A low-temperature reaction route is introduced based on hydroxide precipitation method to synthesize a cathode material LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2}. The charge-discharge tests were performed at 1000 mA g{sup -1} between 2.5 and 4.5 V and the discharge capacity is about 160 mAh g{sup -1}. The discharge capacity of the material is strongly impacted by the reaction temperature. The powders sintered at 850 {sup o}C show the best electrochemical performance. Highlights: {yields} A low-temperature reaction route is introduced based on hydroxide precipitation method to synthesize a novel cathode material LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2}. {yields} The charge-discharge tests were performed at higher current as 5 C between 2.5 and 4.5 V. {yields} The discharge capacity of the material is strongly impacted by the reaction temperature. The powders sintered at 850 {sup o}C show the best electrochemical performance. -- Abstract: A low-temperature reaction route is introduced based on hydroxide precipitation method to synthesize the cathode material LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2}. The crystal structure and morphology of the prepared powder have been characterized by X-ray diffraction and Scan electron microscope, respectively. The charge-discharge tests were performed between 2.5 and 4.5 V. The discharge capacity of the material is strongly impacted by the reaction temperature. The powders sintered at 850 {sup o}C show the best electrochemical performance and the initial discharge capacity is about 160 mAh g{sup -1} at 5 C. Powder X-ray diffraction and Scan electron microscope results reveal that the excellent electrochemical performances should be ascribed to the lower precursor reaction temperature, the lower degree of cation mixing and analogous spherical small particles, which can improve the transfer of Li ions and electrons. All these results indicate that this material has potential application in lithium-ion batteries.

36 MATERIALS SCIENCE↗

Initial Field Testing in the Deep Subsurface for the Thermal Breakout Project for Measuring In Situ Stress

The current state-of-the-art technology for in situ stress measurements involves an integrated approach that combines borehole breakout observations, drilling-induced tensile fractures, and hydraulic fracturing tests (i.e., mini-fracs); however, this methodology has several limitations that often prevent successful in situ stress measurements. One major limitation is that breakouts do not appear in every borehole and are generally a natural occurrence that cannot easily be controlled. Because borehole breakouts are used to measure the maximum horizontal in situ stress magnitude, the absence of borehole breakouts presents a major data gap for in situ stress measurements. As a response to this data gap a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. An initial component of the thermal breakout project involves developing a prototype downhole tool and performing field testing in the deep subsurface. The primary objective of the initial tool development and field testing is to provide a physical proof of concept for the thermal breakout technology. Three thermal breakout field tests were performed at approximately 4850 feet deep in the Sanford Underground Research Facility. Each test was performed in a borehole that had been previously used for overcoring stress measurements. The third and final test successfully created two diametrically opposed breakouts after deploying the thermal breakout tool for approximately 3 hours of continuous heating. Post-analysis of the thermally induced breakouts confirmed that the thermal breakout orientation directly corresponds to the known in situ stress orientation and magnitude.

Voegeli, Sam↗

Analytical and Performance-Based Evaluation Alternatives to Full-Scope, High-Fidelity Testbeds

One consequence the design and operational differences of advanced reactors is that integrated system validation (ISV) using full-scope, high-fidelity testbed might not be cost-justified or practical. The absence of traditional ISV may pose an issue for the conduct of safety evaluations since it may leave regulators without the information derived from this performance-based testing. The purpose of this research is to identify analytical and performance-based test and evaluation methods that are alternatives to full-scope, high-fidelity testbeds that have traditionally been used for ISV. We developed a method to test validation based on a multi-stage validation (MSV) framework. MSV is an approach to meeting validation objectives through incremental, successive validation activities beginning in the early stages of the design process and continuing through the later stages. MSV doesn't rely solely on late stage validation, rather it accommodates the use of a broad spectrum of analytical and performance-based information and a diversity of testbeds. In addition, MSV embraces the use of information from other types of evaluations and analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature control in a 30 stage, 5-cm Centrifugal Contactor Pilot Plant

Temperature profile testing was performed using a 30 stage 5-cm centrifugal contactor pilot plant. These tests were performed to evaluate the ability to control process temperature by adjusting feed solution temperatures. This would eliminate the need for complex jacketed heat exchanger installation on the centrifugal contactors. Thermocouples were installed on the inlet and outlets of each stage, as well as directly in the mixing zone of several of the contactor stages. Lamp oil, a commercially available alkane mixture of C14 to C18 chains, and tap water adjusted to pH 2 with nitric acid were the solution feeds for the temperature profile testing. Temperature data profiles for an array of total throughputs and contactor rpm values for both single-phase and two-phase systems were collected with selected profiles. The total throughput ranged from 0.5-1.4 L/min with rotor speeds from 3500-4000 rpm. Inlet solution temperatures ranging from ambient up to 50 °C were tested. Results of the two-phase temperature profile testing are detailed

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion Testing of Bubbler Materials for LAW Vitrification (Rev. 0)

This work involved crucible-scale corrosion tests using coupons of selected materials in the baseline glass formulations for the seven LAW Sub-Envelopes. The tests were performed with Inconel 690 and MA 758; per the Test Plan, selected tests were also performed with a proprietary high temperature alloy supplied by SRTC. Coupons of these materials were tested for their corrosion resistance to LAW baseline glasses in two test series: the first series was with a baseline glass only, the second series was with a baseline glass and an added salt layer.

36 MATERIALS SCIENCE↗

Truck Thermoacoustic Generator and Chiller

This Final Report describes the accomplishments of the US Department of Energy (DOE) cooperative agreement project DE-FC26-04NT42113 - Truck Thermoacoustic Generator and Chiller - whose goal is to design, fabricate and test a thermoacoustic piezoelectric generator and chiller system for use on over-the-road heavy-duty-diesel trucks, driven alternatively by the waste heat of the main diesel engine exhaust or by a burner integrated into the thermoacoustic system. The thermoacoustic system would utilize engine exhaust waste heat to generate electricity and cab air conditioning, and would also function as an auxiliary power unit (APU) for idle reduction. The unit was to be tested in Volvo engine performance and endurance test cells and then integrated onto a Class 8 over-the-road heavy-duty-diesel truck for further testing on the road. The project has been a collaboration of The Pennsylvania State University Applied Research Laboratory, Los Alamos National Laboratory, Clean Power Resources Inc., and Volvo Powertrain (Mack Trucks Inc.). Cost share funding was provided by Applied Research Laboratory, and by Clean Power Resources Inc via its grant from Innovation Works - funding that was derived from the Commonwealth of Pennsylvania. Los Alamos received its funding separately through DOE Field Work Proposal 04EE09.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Treatment of Irradiated Graphite from French Bugey Reactor - 13424

Beginning in 2009, in order to determine an alternative to direct disposal for decommissioned irradiated graphite from EDF's Bugey NPP, Studsvik and EDF began a test program to determine if graphite decontamination and destruction were practicable using Studsvik's thermal organic reduction (THOR) technology. The testing program focused primarily on the release of C-14, H-3, and Cl-36 and also monitored graphite mass loss. For said testing, a bench-scale steam reformer (BSSR) was constructed with the capability of flowing various compositions of gases at temperatures up to 1300 deg. C over uniformly sized particles of graphite for fixed amounts of time. The BSSR was followed by a condenser, thermal oxidizer, and NaOH bubbler system designed to capture H-3 and C-14. Also, in a separate series of testing, high concentration acid and peroxide solutions were used to soak the graphite and leach out and measure Cl-36. A series of gasification tests were performed to scope gas compositions and temperatures for graphite gasification using steam and oxygen. Results suggested higher temperature steam (1100 deg. C vs. 900 deg. C) yielded a practicable gasification rate but that lower temperature (900 deg. C) gasification was also a practicable treatment alternative if oxygen is fed into the process. A series of decontamination tests were performed to determine the release behavior of and extent to which C-14 and H-3 were released from graphite in a high temperature (900-1300 deg. C), low flow roasting gas environment. In general, testing determined that higher temperatures and longer roasting times were efficacious for releasing H-3 completely and the majority (80%) of C-14. Manipulating oxidizing and reducing gas environments was also found to limit graphite mass loss. A series of soaking tests was performed to measure the amount of Cl-36 in the samples of graphite before and after roasting in the BSSR. Similar to C-14 release, these soaking tests revealed that 70-80% Cl-36 is released during roasting tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation and extraction of Am(VI) using a monoamidic extractant in 3D printed centrifugal contactors

In this study, a series of tests were performed using centrifugal contactors to evaluate the separation of Am(VI) from cerium, as well as to determine the efficiency of the contactors. All experiments were performed using 2-cm, acrylic 3D-printed centrifugal contactors. Solvent extraction tests were performed using 1 M N,N-di(2-ethylhexyl)butyramide (DEHBA)/dodecane and a nitric acid feed solution spiked with 243 Am and 139 Ce and oxidized with 60 mg mL -1 sodium bismuthate. Approximately 72 % of the Am was extracted with a single contactor stage. Co-stripping of Am and Ce was demonstrated but attempts at selective stripping were not successful. Lastly, successful recycle of the used organic phase was demonstrated. Contactor efficiencies of 95-100% were obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RITE Gen5 KHPS Performance - Period B

Includes Kinetic Hydropower System (KHPS) Turbine performance data from the RITE Gen5 KHPS turbine at the 5 meter size. This data was collected over 16 days in May 2021 during Period B operation. Along with performance data, the data includes setup data, project metadata, and characteristic data for RITE Gen5 KHPS (5m) turbine.

16 TIDAL AND WAVE POWER↗

Critical heat flux impact due to cladding surface condition

This paper demonstrates how the cladding surface condition can impact fuel rod heat transfer and critical heat flux (CHF) performance at Pressurized Water Reactor (PWR) type conditions. The cladding surface that is investigated here is a surface with a crud deposit similar to ones observed in a PWR reactor. Tests are performed in the Westinghouse WALT (Westinghouse Advanced Loop Tester) loop test facility where a single ZIRLO clad electrically heated rod with approximately one-foot length is tested at PWR thermal hydraulic conditions and chemistry. Tests are performed for a normal clean rod surface, an oxide surface and with CRUD deposits to investigate the impact on fuel rod heat transfer and CHF performance. The CRUD deposit is characterized for thickness, chimney size and porosity. Test results are presented for the different cladding surface conditions along with comparisons to evaluations performed in the literature for different surfaces at pool boiling conditions. The results indicate that the WALT loop test facility can produce CHF test results which are repeatable for the same heater rod and for different rods with the same surface condition. CHF test results for a ZIRLO cladding surface with a CRUD deposit near 20 microns typical of PWR deposits show similar CHF performance to clean rod surfaces. A noticeable increase in CHF performance was observed for a ZIRLO cladding surface with a thermal oxide layer based on one CHF measurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results Of The Excreta Bioassay Quality Control Program For April 1, 2007 Through March 31, 2008

A total of 79 urine samples, 3 blank fecal and 5 spiked artificial fecal samples were submitted during the report period (April 1, 2007 through March 31, 2008) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.8% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 35% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 24 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4). IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

61 RADIATION PROTECTION AND DOSIMETRY↗

ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM- 2007

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. The 2007 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. A very small amount of material had seeped from Tank 12 from a previously identified leaksite. The material observed had dried on the tank wall and did not reach the annulus floor. A total of 5945 photographs were made and 1221 visual and video inspections were performed during 2007. Additionally, ultrasonic testing was performed on four Waste Tanks (15, 36, 37 and 38) in accordance with approved inspection plans that met the requirements of WSRC-TR-2002- 00061, Revision 2 'In-Service Inspection Program for High Level Waste Tanks'. The Ultrasonic Testing (UT) In-Service Inspections (ISI) are documented in a separate report that is prepared by the ISI programmatic Level III UT Analyst. Tanks 15, 36, 37 and 38 are documented in 'Tank Inspection NDE Results for Fiscal Year 2007'; WSRC-TR-2007-00064.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of a main steam line break with steam generator tube rupture using trace

A simulation of the OECD/NEA ROSA-2 Project Test 5 was made with the thermal-hydraulic code TRACE5. Test 5 performed in the Large Scale Test Facility (LSTF) reproduced a Main Steam Line Break (MSLB) with a Steam Generator Tube Rupture (SGTR) in a Pressurized Water Reactor (PWR). The result of these simultaneous breaks is a depressurization in the secondary and primary system in loop B because both systems are connected through the SGTR. Good approximation was obtained between TRACE5 results and experimental data. TRACE5 reproduces qualitatively the phenomena that occur in this transient: primary pressure falls after the break, stagnation of the pressure after the opening of the relief valve of the intact steam generator, the pressure falls after the two openings of the PORV and the recovery of the liquid level in the pressurizer after each closure of the PORV. Furthermore, a sensitivity analysis has been performed to know the effect of varying the High Pressure Injection (HPI) flow rate in both loops on the system pressures evolution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

COMPARISON OF EXPERIMENTAL RESULTS TO CFD MODELS FOR BLENDING IN A TANK USING DUAL OPPOSING JETS

Research has been completed in a pilot scale, eight foot diameter tank to investigate blending, using a pump with dual opposing jets. The jets re-circulate fluids in the tank to promote blending when fluids are added to the tank. Different jet diameters and different horizontal and vertical orientations of the jets were investigated. In all, eighty five tests were performed both in a tank without internal obstructions and a tank with vertical obstructions similar to a tube bank in a heat exchanger. These obstructions provided scale models of several miles of two inch diameter, serpentine, vertical cooling coils below the liquid surface for a full scale, 1.3 million gallon, liquid radioactive waste storage tank. Two types of tests were performed. One type of test used a tracer fluid, which was homogeneously blended into solution. Data were statistically evaluated to determine blending times for solutions of different density and viscosity, and the blending times were successfully compared to computational fluid dynamics (CFD) models. The other type of test blended solutions of different viscosity. For example, in one test a half tank of water was added to a half tank of a more viscous, concentrated salt solution. In this case, the fluid mechanics of the blending process was noted to significantly change due to stratification of fluids. CFD models for stratification were not investigated. This paper is the fourth in a series of papers resulting from this research (Leishear, et.al. [1- 4]), and this paper documents final test results, statistical analysis of the data, a comparison of experimental results to CFD models, and scale-up of the results to a full scale tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Executive Summary for the SNL SWIFT V27 Wind Turbine Dynamic Characterization

This final report summarizes ATA Engineering Inc.'s experimental dynamic characterization of the Sandia National Laboratories (SNL) Scaled Wind Farm Technology (SWIFT) Vestas 27 (V27) wind turbine components and fully assembled turbines. Testing was performed at SNL's SWIFT facility in Lubbock, Texas, from October 2012 through June 2013.Dynamic testing consisted of modal testing of the individual blades, the towers in a free-free boundary condition, the towers bolted to the foundations, and the fully assembled wind turbines. Additionally, modal testing was performed on a hub and two nacelles to determine the mass and inertia properties of these components. Details on these tests can be found in their respective reports.

17 WIND ENERGY↗

Determination of the impact of glycolate on arp and mcu operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5,000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5,000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similarly to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. In addition to the MST and mMST testing, testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5,000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests. (A single data point in the 5,000 ppm test is physically impossible and SRNL is currently resolving this obvious error.) At this time, SRNL concludes that the presence of up to 10,000 ppm of glycolate does not affect cesium removal by the current solvent system used in the MCU. Although not tested, the impact of glycolate for the Next Generation Solvent - that replaces BOBCalixC6 with MaxCalix - is expected to be very similar to that for the baseline solvent. Testing is needed to confirm. Additional testing is recommended to both further examine the nature of the interaction of glycolate with MST and mMST and also to help address some postulated risks on ARP/MCU operations with implementation of the glycolate flowsheet. The additional testing includes FTIR and Raman spectroscopy to examine the surface of the MST and mMST particles, iodometric titrations to determine the peroxide content in the mMST before and after exposure to glycolate, particle size measurements of the MST and mMST from the experiments performed with glycolate, and measurements of soluble Ti in the supernate from these glycolate experiments. With regards to MCU impacts, the following tests are also recommended based on the premortem risk assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗