Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Flow Regime Transitions and Pressure Drop in Gas-Liquid Flows through Packed Beds in Microgravity

The Packed Bed Reactor Experiment (PBRE) focused on the hydrodynamics of gas-liquid flow in porous media, specifically on flow regime transition and pressure drop correlation. The reactor included a cylindrical test section of 60 cm in length, 5 cm in diameter and filled with 2 mm spherical glass beads. Liquid water and Nitrogen gas were flowed into a centrifugal phase separator after exiting the test section. Five absolute pressure transducers and two high-speed video cameras spanned the test section to measure the pressure drop and capture flow regime behavior. Video observations, analysis of pressure traces, and pressure drop data were used to identify flow patterns. It was found that the slope of pressure gradient data when plotted versus the gas or liquid Reynolds numbers changed when the flow regime changed. This observation was used to identify the flow regime boundaries. At high liquid flow rates (high interaction regime), dispersed bubble and pulse flow regimes were detected. At low liquid flow rates (low interaction regime), large bubble and gas channeling regimes were observed. The transition from the big bubble regime to the gas channeling regime occurred at a critical gas flow rate independent of the liquid flow rate. Similarly, the transition from the low interaction to the high interaction regime occurred at a critical liquid flow rate. For these different flow regimes, different two-phase flow friction factors and pressure gradient correlations were fitted as a function of the gas and liquid modified Reynolds numbers and Suratman number. It was found that in all the flow regimes the capillary contribution to the pressure drop is significant and can be as high as 90% of the total pressure drop.

Brian Motil↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Loci/STREAM Sharp Interface Model Validation of Cryogenic Propellant Tank Self-Pressurization

This paper documents a model validation effort for the prediction of cryogenic propellant tank selfpressurization physics using the Loci/STREAM sharp interface CFD model developed at NASA MSFC. Cryogenic fluid management (CFM) applications for long duration spaceflight missions require accurate modeling of heat transfer and thermodynamics. Therefore, detailed validation of those physics is important to ensure simulation accuracy. In the past, the MSFC Propulsion Fluid Dynamics Branch has validated and used the Loci/STREAM Volume of Fluid (VOF) module extensively for propellant slosh applications, which are dominated by fluid motion. For cases where the interface gas/liquid interface is essentially static, the Loci/STREAM sharp interface was developed for more rapid and efficient CFM analysis. In the present study, Loci/STREAM sharp interface simulations were compared with the NASA K-site self-pressurization experiment of a flight weight, partially full, LH2 tank in normal gravity. This study investigated several parametric effects and made a number of important observations on the performance of the Loci/STREAM sharp interface method: - First, a homogeneous model was derived to verify the CFD model. The homogeneous model assumes both gas and liquid phases are uniform and are at saturation temperature. The predicted pressure rise rates at 3.5 W/m2 and 2.0 W/m2 with a 49% fill level are all lower than the experimental measurement. This is expected due to the observed temperature stratification near the gas-liquid interface during testing. - The k-w and k-e turbulence models predict comparable pressurization rates, which are much lower than the experiment measurement. On the other hand, the pressure values and pressurization rates from both models are almost the same as those of the homogeneous model. The current turbulence model is too diffusive and is not capable of capturing the thermal stratification in the liquid and ullage. - When using the laminar flow model, the pressurization rate is found to be very close to the experimental value when a quasi-steady flow field is allowed to develop by continuously venting the tank prior to pressurization as was done during testing. On the other hand, without initial venting, the rate is not constant. Additionally, the development time to reach a quasi-steady flow field differed from the experiment due to the lack of turbulent mixing away from the gas-liquid interface that is expected in reality. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 15% of the experimental value for 49% fill level at 3.5 W/m 2 and is within 18% for 2.0 W/m 2 heat loading. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 18% of the experimental value for a 29% fill level and within 15% for an 83% fill level.

H. Q. Yang↗

Pressure calibration to 20 GPa by simultaneous use of ultrasonic and x ray techniques

Simultaneous measurements of elastic P- and S-wave travel times, density (specific volume), and sample length using a multianvil apparatus interfaced with ultrasonic interferometry and x-ray diffraction and radiography have enabled simultaneous determination of elastic properties and absolute pressure at high pressures and high temperatures. Experimental procedures and data analyses are demonstrated using data collected on polycrystalline samples of ferropericalse (MgFe) and wadsleyite Mg{sub 2}SiO{sub 4} under quasihydrostatic conditions up to 20 GPa. Compared with those derived from the internal pressure standard in the same experiments based on equations of state of NaCl, the directly determined pressure at 20 GPa is {approx}8% and {approx}12% higher than those inferred from the Brown and Decker pressure scales, respectively. The discrepancy cannot be reconciled by uncertainties in the NaCl pressure scale and current experimental data. Until further results are available, the pressure determined in this study is believed to be a more accurate measurement of the effective pressure imposed on the sample than that inferred from NaCl based on previous pressure scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves

Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intended safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.

42 ENGINEERING↗

Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids

A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be used to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.

42 ENGINEERING↗

Converging towards atomic and nuclear pressures (Final Report)

his report details the development of transformational tools and techniques, allowing the accurate characterization of matter at the most extreme conditions yet studied in the high energy density (HED) domain. Before this work, most experiments quantitatively mapping the nature of matter in the HED realm were performed using planar geometry, which allows for the isolation and measurement of variables in a single thermodynamic state. Such measurements include equation of state variables, optical conductivity, heat transport and more. However, due to a variety of plasma processes, such experiments are limited to below ~10 TPa (100 Mbar) pressures. To achieve higher pressures, convergent experiments are needed. Historically, convergent experiments have not been used for benchmark data because they are integral measurements. That is each part of a convergent target undergoes a time dependent wide range of states, making it difficult to accurately isolate any particular quantity for a given thermodynamic state. This effort developed innovative convergent HED platforms and techniques enabling the exploration of matter from atomic to nuclear scale pressures. This effort also performed pioneering experiments that yielded the first rigorous benchmark data at these extreme conditions. This funding award began with the overarching goal to understand the behavior of matter at extreme (atomic-to-nuclear scale) pressures. The motivation for these goals lie in the fact that every time scientists explore matter beyond the threshold of an atomic unit, there is a fundamental shift in science. The atomic unit for energy, mass, charge, length, and time have each been explored, and each time such a threshold was crossed, a new sequence of discoveries was made resulting in significant awards such as the Nobel Prize. The only unexplored atomic unit is pressure, and this effort set the course for exploring matter at and beyond such pressures. That most of the recently discovered extrasolar planets and stars, as well as matter in the late implosion stages of inertial fusion targets, have deep internal pressures at and beyond atomic pressures amplifies the importance of this effort. Much of the initial work in developing techniques to create these atomic-to-nuclear pressures already existed within the HED community, predominantly at large scale laser facilities such as the National Ignition Facility (NIF) and the Omega60 laser the University of Rochester and although these experiments were routinely performed the ability to extract information about the underlying physical states and processes remained elusive due to the complexity of the experiments, extreme scales in both time and space, and the integrated nature of all the measurements. This work built a rigorous framework so such measurements can routinely be made. This was done in part through the introduction of Bayesian inference techniques into the field of HED science. These techniques allow for the self-consistent extraction of the relevant variables and their explicit and implicit correlations, so as to make use of integrated experimental data to constrain physical models and provide accurate uncertainty bounds for the data. The techniques developed here are fully transparent and proved immediately useful providing quantitative rigorous benchmarks for physical states and processes at some of the most extreme conditions yet explored on Earth. This funding is directly or partly responsible for 7 publications in major peer-reviewed scientific journals, a doctoral thesis, 3 invited talks at major conferences, and the training of a post-doc, 2 graduate students, and 1 undergraduate student. Beyond the effort supported by this award launched the introduction of Bayesian inference into the HED physics community and helped push the usage if modern data-science techniques within the physics community at large.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Scaling Criteria for Modeling Condensation in Horizontal Tubes Using Reduced Pressure System and Simulant Fluid

Most of the currently operating nuclear power plants (NPPs), generation-II and III, are equipped with active safety systems, which raises concerns regarding those safety systems' operational reliability and the suitability of the accidents prevention measures. Following the severe accidents at nuclear power plants at Three Mile Island, Chernobyl, and recently in Fukushima some advance Pressurized Water Reactors (PWRs) have adopted passively cooled steam generator natural circulation system to remove the decay heat passively through the steam generator (SG). This is done by condensing steam from the steam generator inside a heat exchanger submerged in a tank of water or an air cooled system. The APR+ (Advanced Power Reactor Plus), which is currently being developed in South Korea, has adopted a Passive Auxiliary Feedwater System (PAFS), which removes the decay heat through the steam generator replacing the conventional active auxiliary feedwater system. The main part of the PAFS, in where the steam condenses, is the Passive Condensation Heat Exchanger (PCHX). The steam condenses under high pressure (7.4 MPa, 290 deg. C) in 8.4 m long horizontal tube, with 3 degrees inclination, with inner diameter of 44.8 mm and wall thickness of 3 mm. The PCHX consists of 4 bundles, each bundle has 60 condensation tubes. The performance of the PCHX performance should be evaluated. Condensation has been extensively studied; however, most previous experimental work was directed to low pressure (i.e., near atmospheric pressure) and small condensation tubes. Moreover, studies on the horizontal type heat exchanger are limited, since previous safety systems and experimentation work were directed to the vertical type heat exchangers. Due to the high construction cost of a full size high pressure condensation experiment, a reduced-size reduced-pressure condensation experiment is suggested to evaluate the heat removal performance of a condensation tube of the PAFS heat exchanger. A scaling methodology to be established to design a reduced-size reduced-pressure condensation experiment. This study attempts to develop a scaling criteria for the PAFS condensation system, and to apply it for modeling a high pressure water system by a low pressure Freon system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Portable self-contained pressure testing manifold and associated methods

A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.

Milholland, Roger A.↗

Pressurizer dynamic model and emulated programmable logic controllers for nuclear power plants cybersecurity investigations

This work demonstrates the functionality of the pressurizer using a fast-running three regions, non-equilibrium model and control programs of emulated PLCs. The state variables from an integrated model of primary loop in a representative PWR plant are communicated to the pressurizer’s emulated PLCs using a synchronized data transfer function. In turn, the PLCs communicate back instructions to the pressurizer model to adjust the pressure and water level to remain within preprogramed setpoints. Pressurizer model simultaneously solves the coupled mass and energy conservation equations in the saturated vapor and saturated and subcooled liquid regions using fixed step solver. Results demonstrate the response of the pressurizer model linked to an emulated pressure and water level PLCs in a simulated transient involving surge-in and surge-out events. The 50 ms response delay time for the emulated PLC insignificantly affects operation and predictions of the pressurizer model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pressure-induced structural transformations in lanthanide titanates: La{sub 2}TiO{sub 5} and Nd{sub 2}TiO{sub 5}

The structure of orthorhombic rare earth titanates of La{sub 2}TiO{sub 5} and Nd{sub 2}TiO{sub 5}, where Ti cations are in five-fold coordination with oxygen, has been studied at high pressures by X-ray diffraction (XRD), Raman scattering measurements, and quantum mechanical calculations. Both XRD and Raman results indicated two pressure-induced phase transitions during the process. An orthorhombic super cell (axbx2c) formed at a pressure between 6 and 10 GPa, and then transformed to a hexagonal high-pressure phase accompanied by partial decomposition. The hexagonal high-pressure phase is quenchable. Detailed structural analysis indicated that the five-coordinated TiO{sub 5} polyhedra remain during the formation of super cell, but the orthorhombic-to-hexagonal phase transition at high pressures is a reconstructive process, and the five-fold Ti-O coordination increased to more than 6. This phase transition sequence was verified by quantum mechanical calculations. - Graphical abstract: At high pressures, La{sub 2}TiO{sub 5} and Nd{sub 2}TiO{sub 5} transform from the orthorhombic phase to an axbx2c superlattice of the orthorhombic structure and then to a hexagonal high-pressure phase. Display Omitted

36 MATERIALS SCIENCE↗

High-pressure synthesis and structural behavior of sodium orthonitrate Na{sub 3}NO{sub 4}

Sodium orthonitrate (Na{sub 3}NO{sub 4}) is an unusual phase containing the first example of isolated tetrahedrally bonded NO{sub 4}{sup 3-} groups. This compound was obtained originally by heating together mixtures of Na{sub 2}O and NaNO{sub 3} for periods extending up to >14 days in evacuated chambers. Considering the negative volume change between reactants and products, it was inferred that a high-pressure synthesis route might favor the formation of the Na{sub 3}NO{sub 4} compound. We found that the recovered sample is likely to be a high-pressure polymorph, containing NO{sub 4}{sup 3-} groups as evidenced by Raman spectroscopy. The high-pressure behavior of Na{sub 3}NO{sub 4} was studied using Raman spectroscopy and synchrotron X-ray diffraction in a diamond anvil cell above 60 GPa. We found no evidence for major structural transformations, even following laser heating experiments carried out at high pressure, although broadening of the Raman peaks could indicate the onset of disordering at higher pressure. -- Graphical abstract: We studied Na{sub 3}NO{sub 4} at high pressure using Raman spectroscopy and X-ray diffraction and determined V(P) to 64 GPa. We investigated synthesis and phase behavior of the orthonitrate at high-P,T conditions. Display Omitted Research highlights: {yields} Investigation of Na{sub 3}NO{sub 4} at extreme compression (up to 64 GPa) using Raman spectroscopy and X-ray diffraction. {yields} Synthesis of Na{sub 3}NO{sub 4} via high-pressure conditions. {yields} Estimation of the bulk moduli of Na{sub 3}NO{sub 4} and Na{sub 2}O and comparison with related compounds. {yields} Exploratory laser heating run in search for high-pressure Na{sub 3}NO{sub 4} phases.

36 MATERIALS SCIENCE↗

Behavior of silver molybdate at high-pressure

Behavior of cubic spinel phase of Ag{sub 2}MoO{sub 4} is investigated at high pressure using X-ray diffraction and Raman spectroscopy. The P-V data are fitted to a third order Birch-Murnaghan equation of state using a value of B{sub 0}=113 GPa and B Prime {sub 0}=4. The compound is also found to exhibit a phase transition around 5 GPa to a tetragonal structure and the two phases are found to coexist over a range of pressures. Raman spectra exhibit dramatic changes across the phase transition. Increase of X-ray background scattering and broadening of the Raman peaks associated with MoO{sub 4} tetrahedral ions in the high pressure phase suggest evolution of positional disorder. However, no evidence of pressure-induced amorphization was found up to 47 GPa. - Graphical abstract: Evolution of the integrated intensity of all the diffraction peaks between 12 and 18 degree 2{theta} as a function of pressure. The rapid decrease of the intensity suggests evolution of positional disorder in the high-pressure tetragonal phase. Highlights: Black-Right-Pointing-Pointer First in-situ X-ray diffraction and Raman study of cubic silver molybdate at high pressure. Black-Right-Pointing-Pointer Commencement of a structural transition to a tetragonal phase is found at 2.3 GPa. Black-Right-Pointing-Pointer The high-pressure phase is found to have positional disorder. Black-Right-Pointing-Pointer A bulk modulus of 113 GPa is obtained from the equation of state.

36 MATERIALS SCIENCE↗

Photoluminescence studies on self-organized 1.55-μm InAs/InGaAsP/InP quantum dots under hydrostatic pressure

We report an experimental study on the optical properties of the self-organized 1.55-μm InAs/InGaAsP/InP quantum dots (QDs) under hydrostatic pressure up to 9.5 GPa at 10 K. The obtained pressure coefficients of emissions from InGaAsP to InAs QDs are 92 meV/GPa and 76 meV/GPa, respectively. Their photoluminescence intensities are found to decrease significantly with increasing pressure due to the pressure-induced Γ-X mixing of InGaAsP at about 8.5 GPa. The lifetime of excitonic emission from QDs decreases from about 1.15 at zero pressure to about 1.05 ns at 7.41 GPa. The wavelength of QD emission was tuned from 1.55 to 0.9 μm by applying a pressure of 8 GPa, displaying the feasibility for indirectly characterizing the individual InAs/InGaAsP/InP QDs of 1.55-μm emission (at zero pressure) under high-pressure using silicon avalanche photodiode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prediction of new high pressure structural sequence in thorium carbide: A first principles study

In the present work, we report the detailed electronic band structure calculations on thorium monocarbide. The comparison of enthalpies, derived for various phases using evolutionary structure search method in conjunction with first principles total energy calculations at several hydrostatic compressions, yielded a high pressure structural sequence of NaCl type (B1) → Pnma → Cmcm → CsCl type (B2) at hydrostatic pressures of ∼19 GPa, 36 GPa, and 200 GPa, respectively. However, the two high pressure experimental studies by Gerward et al. [J. Appl. Crystallogr. 19, 308 (1986); J. Less-Common Met. 161, L11 (1990)] one up to 36 GPa and other up to 50 GPa, on substoichiometric thorium carbide samples with carbon deficiency of ∼20%, do not report any structural transition. The discrepancy between theory and experiment could be due to the non-stoichiometry of thorium carbide samples used in the experiment. Further, in order to substantiate the results of our static lattice calculations, we have determined the phonon dispersion relations for these structures from lattice dynamic calculations. The theoretically calculated phonon spectrum reveal that the B1 phase fails dynamically at ∼33.8 GPa whereas the Pnma phase appears as dynamically stable structure around the B1 to Pnma transition pressure. Similarly, the Cmcm structure also displays dynamic stability in the regime of its structural stability. The B2 phase becomes dynamically stable much below the Cmcm to B2 transition pressure. Additionally, we have derived various thermophysical properties such as zero pressure equilibrium volume, bulk modulus, its pressure derivative, Debye temperature, thermal expansion coefficient and Gruneisen parameter at 300 K and compared these with available experimental data. Further, the behavior of zero pressure bulk modulus, heat capacity and Helmholtz free energy has been examined as a function temperature and compared with the experimental data of Danan [J. Nucl. Mater. 57, 280 (1975)].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cobalt ferrite nanoparticles under high pressure

We report by the first time a high pressure X-ray diffraction and Raman spectroscopy study of cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles carried out at room temperature up to 17 GPa. In contrast with previous studies of nanoparticles, which proposed the transition pressure to be reduced from 20–27 GPa to 7.5–12.5 GPa (depending on particle size), we found that cobalt ferrite nanoparticles remain in the spinel structure up to the highest pressure covered by our experiments. In addition, we report the pressure dependence of the unit-cell parameter and Raman modes of the studied sample. We found that under quasi-hydrostatic conditions, the bulk modulus of the nanoparticles (B{sub 0} = 204 GPa) is considerably larger than the value previously reported for bulk CoFe{sub 2}O{sub 4} (B{sub 0} = 172 GPa). In addition, when the pressure medium becomes non-hydrostatic and deviatoric stresses affect the experiments, there is a noticeable decrease of the compressibility of the studied sample (B{sub 0} = 284 GPa). After decompression, the cobalt ferrite lattice parameter does not revert to its initial value, evidencing a unit cell contraction after pressure was removed. Finally, Raman spectroscopy provides information on the pressure dependence of all Raman-active modes and evidences that cation inversion is enhanced by pressure under non-hydrostatic conditions, being this effect not fully reversible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗