Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

InP AAC for data compression applications

The authors propose a 2 × 2 asymmetric adiabatic coupler (AAC) indium phosphide (InP) photonic integrated circuit (PIC), suitable for tunable power applications such as all‐optical data processing. The device was idealised as the key building block in Haar transform network used for image compression, allowing to perform the necessary separate addition and subtraction of incoming input signals at its output ports. The tunable behaviour of the coupler was demonstrated experimentally for addition/subtraction and splitting (with experimental coupling ratios of 77:23/14:86 and 50:50, respectively) through phase control. The use of the developed InP PIC enables a low footprint structure design together with the high‐quality active components (lasers, photodetectors and phase modulators) of Fraunhofer Gesellschaft Heinrich Hertz Institute design toolkit. The proposed study provides a full experimental characterisation of the AAC, exploring its tuning properties and enabling further usage in a plethora of applications in high processing computing and data communications.

Pinho, Cátia↗

Status of the design of the ITER ECE diagnostic

In this study, the baseline design for the ITER electron cyclotron emission (ECE) diagnostic has entered the detailed preliminary design phase. Two plasma views are planned, a radial view and an oblique view that is sensitive to distortions in the electron momentum distribution near the average thermal momentum. Both views provide high spatial resolution electron temperature profiles when the momentum distribution remains Maxwellian. The ECE diagnostic system consists of the front-end optics, including two 1000 K calibration sources, in equatorial port plug EP9, the 70-1000 GHz transmission system from the front-end to the diagnostics hall, and the ECE instrumentation in the diagnostics hall. The baseline ECE instrumentation will include two Michelson interferometers that can simultaneously measure ordinary and extraordinary mode ECE from 70 to 1000 GHz, and two heterodyne radiometer systems, covering 122-230 GHz and 244-355 GHz. Significant design challenges include 1) developing highly-reliable 1000 K calibration sources and the associated shutters/mirrors, 2) providing compliant couplings between the front-end optics and the polarization splitter box that accommodate displacements of the vacuum vessel during plasma operations and bake out, 3) protecting components from damage due to stray ECH radiation and other intense millimeter wave emission and 4) providing the low-loss broadband transmission system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Associative Memory in Hep Track Pattern Recognition

We have entered the Noisy Intermediate-Scale Quantum Era. A plethora of quantum processor prototypes allow evaluation of potential of the Quantum Computing paradigm in applications to pressing computational problems of the future. Growing data input rates and detector resolution foreseen in High-Energy LHC (2030s) experiments expose the often high time and/or space complexity of classical algorithms. Quantum algorithms can potentially become the lower-complexity alternatives in such cases. In this work we discuss the potential of Quantum Associative Memory (QuAM) in the context of LHC data triggering. We examine the practical limits of storage capacity, as well as store and recall errorless efficiency, from the viewpoints of the state-of-the-art IBM quantum processors and LHC real-time charged track pattern recognition requirements. We present a software prototype implementation of the QuAM protocols and analyze the topological limitations for porting the simplest QuAM instances to the public IBM 5Q and 14Q cloud-based superconducting chips.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Portable Acceleration Solutions for LArTPC Simulation Using Wire-Cell Toolkit

The Liquid Argon Time Projection Chamber (LArTPC) technology plays an essential role in many current and future neutrino experiments. Accurate and fast simulation is critical to developing efficient analysis algorithms and precise physics model projections. The speed of simulation becomes more important as Deep Learning algorithms are getting more widely used in LArTPC analysis and their training requires a large simulated dataset. Heterogeneous computing is an efficient way to delegate computationally intensive tasks to specialized hardware. However, as the landscape of compute accelerators quickly evolves, it becomes increasingly difficult to manually adapt the code to the latest hardware or software environments. A solution which is portable to multiple hardware architectures without substantially compromising performance would thus be very beneficial, especially for long-term projects such as the LArTPC simulations. In search of a portable, scalable and maintainable software solution for LArTPC simulations, we have started to explore high-level portable programming frameworks that support several hardware backends. In this paper, we present our experience porting the LArTPC simulation code in the Wire-Cell Toolkit to NVIDIA GPUs, first with the CUDA programming model and then with a portable library called Kokkos. Preliminary performance results on NVIDIA V100 GPUs and multi-core CPUs are presented, followed by a discussion of the factors affiecting the performance and plans for future improvements.

Yu, Haiwang↗

Evaluating Performance Portability with the CMS Heterogeneous Pixel Reconstruction code

In the past years the landscape of tools for expressing parallel algorithms in a portable way across various compute accelerators has continued to evolve significantly. There are many technologies on the market that provide portability between CPU, GPUs from several vendors, and in some cases even FPGAs. These technologies include C++ libraries such as Alpaka and Kokkos, compiler directives such as OpenMP, the SYCL open specification that can be implemented as a library or in a compiler, and standard C++ where the compiler is solely responsible for the offloading. Given this developing landscape, users have to choose the technology that best fits their applications and constraints. For example, in the CMS experiment the experience so far in heterogeneous reconstruction algorithms suggests that the full application contains a large number of relatively short computational kernels and memory transfer operations. In this work we use a stand-alone version of the CMS heterogeneous pixel reconstruction code as a realistic use case of HEP reconstruction software that is capable of leveraging GPUs effectively. We summarize the experience of porting this code base from CUDA to Alpaka, Kokkos, SYCL, std::par, and OpenMP offloading. We compare the event processing throughput achieved by each version on NVIDIA and AMD GPUs as well as on a CPU, and compare those to what a native version of the code achieves on each platform.

Andriotis, Nikolaos↗

GPU-friendly surface model for Monte-Carlo detector simulations

The demands for Monte-Carlo simulation are drastically increasing with the Large Hadron Collider’s high-luminosity upgrade, and are expected to exceed the currently available compute resources. At the same time, modern high-performance computing has adopted powerful hardware accelerators, particularly GPUs. The AdePT and Celeritas projects aim to address the demanding computational needs by leveraging these heterogeneous computing architectures. While both have successfully ported realistic detector simulations to GPUs using the VecGeom library, the complexity of geometry modeling emerged as a bottleneck. Thread divergence and high register usage were degrading the GPU performance. Therefore, a new, GPU-friendly surface-based model has been introduced in the VecGeom library that decomposes the divergent code of the 3D primitive solids into simpler and more balanced surface algorithms. In this work, we present the latest developments, focusing on the additions required to efficiently model complex setups like the CMS Phase-2 geometry. This includes memory reduction techniques, and adding accelerating structures for faster traversal.

Diederichs, Severin [CERN]↗

Design, Manufacturing, and Installation of DIII-D Lower Hybrid Current Drive Outer Wall Waveguides and Expandable Vacuum Interface

High field side lower hybrid current drive (HFS LHCD) is promising method for efficient, off axis current drive. To operate this system, development of an expandable combination radio frequency (RF) and vacuum interface was necessary to allow the long (~2 m) waveguides to thermally expand with respect to the DIII-D 0 degree R-1 port extension without damage to the waveguide or excessive force on the vacuum seals which was previously observed when baking the waveguides during operations that were installed in 2024. Design of a custom bellows assembly with RF feedthrough that allows >20mm of waveguide thermal expansion is presented. Fabrication of this bellows assembly required simultaneously vacuum brazing multiple 304 stainless steel flanges to an oxygen free high conductivity copper waveguide section which required significant manufacturing development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling ocean, rail, and truck transportation flows to support policy analysis

Freight transportation represents about 9.5% of GDP in the U.S., it is responsible for about 8% of greenhouse gas emissions, and supports the import and export of about 3.6 trillion in international trade. It is therefore important that the national freight transportation system is designed and operated efficiently. Hence, this paper develops a mathematical model to estimate international and domestic freight flows across ocean, rail, and truck modes, which can be used to study the impacts of changes in our infrastructure, as well as the imposition of new user fees and changes in operating policies. The model integrates a user equilibrium-based logit argument for path selection with a system optimal argument for rail network operations. This leads to the development of a unique solution procedure that is demonstrated in a large-scale analysis focused on all intercity freight and U.S export/import containerized freight. The model results are compared with the reported flow volumes. Here, the model is applied to two case studies: a disruption of the seaports of Los Angeles and Long Beach (LA and LB) similar to the impacts that would be felt in an earthquake; and implementation of new user fees at the California ports.

99 GENERAL AND MISCELLANEOUS↗

Studies on x-ray and UV emissions in electron cyclotron resonance x-ray source

A novel electron cyclotron resonance x-ray source is constructed based on the ECR technique. In this paper, the possibility of using the ECR x-ray source for producing UV rays by optimizing the plasma parameters is explored. X-ray and UV emissions from the ECR x-ray source are carried out for argon, nitrogen, and CO{sub 2} plasma. The x-ray spectral and dose measurements are carried with NaI(Tl) based spectrometer and dosimeter, respectively. For UV measurement, a quartz window arrangement is made at the exit port and the UV intensity is measured at 5 cm from the quartz plate using UV meter. The x-ray and UV emissions are carried out for different microwave power levels and gas pressures. The x-ray emission is observed in the pressure range {<=}10{sup -5} Torr, whereas the UV emission is found to be negligible for the gas pressures <10{sup -5} Torr and it starts increasing in the pressure range between 10{sup -5} and 10{sup -3} Torr. At high-pressure range, collision frequency of electron-atom is large which leads to the higher UV flux. At low pressure, the electron-atom collision frequency is low and hence the electrons reach high energy and by hitting the cavity wall produces higher x-ray flux. By choosing proper experimental conditions and plasma gas species, the same source can be used as either an x-ray source or an UV source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic observations of beam and source plasma light and testing Cs-deposition monitor in the large area negative ion source for LHD-NBI

In the large area negative ion source for the LHD negative-ion-(H{sup -})-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H{sub {alpha}} line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H{sub {alpha}} line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs{sup 0}) and Cs II (522 nm, Cs{sup +}) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm{sup 2} for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A broadband method to measure magnetic spectra of thin films

Conventional single-port strip-line techniques to measure permeability of thin films are based on the quasistationary approximation. In this paper, wave phenomena in the measurement cell are taken into account. Particularly, the dielectric response of the sample may be accounted for and removed by the consideration of the geometry of the cell and the sample. An additional measurement with a reference sample with known constitutive parameters allows the directivity error and the frequency response error to be removed from the experimental reflectivity data; accounting for the field inhomogeneity inside the strip cell is also introduced. A proper selection of the reference sample is shown to be critical for the measurement accuracy. The measurement results may also be affected by the demagnetization of the sample. With these corrections introduced, the operating frequency range of the technique is extended up to 8 GHz. The measurement results are validated by the data obtained with either standard materials or by conventional techniques.

36 MATERIALS SCIENCE↗

Retarding field analyzer for ion energy distribution measurements at a radio-frequency biased electrode

A retarding field energy analyzer designed to measure ion energy distributions impacting a radio-frequency biased electrode in a plasma discharge is examined. The analyzer is compact so that the need for differential pumping is avoided. The analyzer is designed to sit on the electrode surface, in place of the substrate, and the signal cables are fed out through the reactor side port. This prevents the need for modifications to the rf electrode--as is normally the case for analyzers built into such electrodes. The capabilities of the analyzer are demonstrated through experiments with various electrode bias conditions in an inductively coupled plasma reactor. The electrode is initially grounded and the measured distributions are validated with the Langmuir probe measurements of the plasma potential. Ion energy distributions are then given for various rf bias voltage levels, discharge pressures, rf bias frequencies - 500 kHz to 30 MHz, and rf bias waveforms - sinusoidal, square, and dual frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The CXRS diagnostic for ITER and the CXRS-Pilot Experiment on TEXTOR

Charge eXchange Recombination Spectroscopy (CXRS) will play a crucial role in the diagnosing of burning plasmas: items like helium ash, transport barriers, impurity content or fuel ratio can all be assessed with CXRS. In fact this is the only direct method to obtain information about the light impurity ions, such as temperature, concentrations and rotation, in the core of the plasma. Two of such systems are foreseen at ITER, one in the upper port plug and one on the equatorial level, both viewing the 100 keV diagnostic H-beam.Challenges for this diagnostic development project are: constructing a mirror close to the plasma able to keep its reflectivity under the extreme bombardment by neutrons, erosion by fast neutrals and deposition of sputtered material, design of an optical labyrinth with well enough neutron shielding, developing spectrometers with a throughput about a factor 100 larger than on present day devices, with a similar or better dispersion, calibration and alignment techniques and last but not least, finding ways to obtain the physics relevant information from the measured complicated spectra in real time.With all these issues in mind, an ITER-CXRS pilot experiment has been developed and became operational on the TEXTOR tokamak, to address some of the above aspects. The results of this show the feasibility and the sensitivity of the ITER system: the simulation code for ITER signal levels could be verified, the sensitivity to the current profile has been tested, the beam emission has been compared to beam attenuation calculations and used to obtain absolute impurity concentrations and a high throughput spectrometer became operational.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ITER Radial Neutron Camera Detection System

A multichannel neutron detection system (Radial Neutron Camera, RNC) will be installed on the ITER equatorial port plug 1 for total neutron source strength, neutron emissivity/ion temperature profiles and n{sub t}/n{sub d} ratio measurements [1]. The system is composed by two fan shaped collimating structures: an ex-vessel structure, looking at the plasma core, containing tree sets of 12 collimators (each set lying on a different toroidal plane), and an in-vessel structure, containing 9 collimators, for plasma edge coverage. The RNC detecting system will work in a harsh environment (neutron fiux up to 10{sup 8}-10{sup 9} n/cm{sup 2} s, magnetic field >0.5 T or in-vessel detectors), should provide both counting and spectrometric information and should be flexible enough to cover the high neutron flux dynamic range expected during the different ITER operation phases. ENEA has been involved in several activities related to RNC design and optimization [2,3]. In the present paper the up-to-date design and the neutron emissivity reconstruction capabilities of the RNC will be described. Different options for detectors suitable for spectrometry and counting (e.g. scintillators and diamonds) focusing on the implications in terms of overall RNC performance will be discussed. The increase of the RNC capabilities offered by the use of new digital data acquisition systems will be also addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development in Diagnostics Application to Control Advanced Tokamak Plasma

For continuous operation expected in DEMO, all the plasma current must be non-inductively driven, with self-generated neoclassical bootstrap current being maximized. The control of such steady state high performance tokamak plasma (so-called 'Advanced Tokamak Plasma') is a challenge because of the strong coupling between the current density, the pressure profile and MHD stability. In considering diagnostic needs for the advanced tokamak research, diagnostics for MHD are the most fundamental, since discharges which violate the MHD stability criteria either disrupt or have significantly reduced confinement. This report deals with the development in diagnostic application to control advanced tokamak plasma, with emphasized on recent progress in active feedback control of the current profile and the pressure profile under DEMO-relevant high bootstrap-current fraction. In addition, issues in application of the present-day actuators and diagnostics for the advanced control to DEMO will be briefly addressed, where port space for the advanced control may be limited so as to keep sufficient tritium breeding ratio (TBR)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements in the Image Quality of Neutron Radiograms of NUR Neutron Radiography Facility by Using Several Exposure Techniques

Since the construction of NUR reactor neutron radiography facility in 1991, only transfer exposure method was used as a non destructive technique. The reason is the excess of gamma rays in the neutron beam. To improve radiation performances of the NR system, a stainless steal hollow conical cylinder is introduced at the bottom of the facility beam port, this filter reduce gamma infiltration through the edges of the NR structure without disturbing neutron beam arriving from the in pool divergent collimator. First results confirm our prediction; a gamma rays diminution and a relatively stable neutron flux at the point object are confirmed, consequently the n/{gamma} ratio reaches a value of 2.104 n/cm{sup 2} mR. Radiograms obtained by using the direct exposure method reveal the feasibility of the technique in the new NR configuration facility, but a weak resolution and contrast of the image is observed. In this paper, we describe a procedure to improve the image quality obtained by direct exposure technique. The process consists of using digitized images obtained by several exposure techniques (NR, gamma radiography or X radiography) for a comparison study and then better image definition can be attained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulsed Neutron Powder Diffraction for Materials Science

The accelerator-based neutron diffraction began in the end of 60's at Tohoku University which was succeeded by the four spallation neutron facilities with proton accelerators at the High Energy Accelerator Research Organization (Japan), Argonne National Laboratory and Los Alamos Laboratory (USA), and Rutherford Appleton Laboratory (UK). Since then, the next generation source has been pursued for 20 years, and 1MW-class spallation neutron sources will be appeared in about three years at the three parts of the world: Japan, UK and USA. The joint proton accelerator project (J-PARC), a collaborative project between KEK and JAEA, is one of them. The aim of the talk is to describe about J-PARC and the neutron diffractometers being installed at the materials and life science facility of J-PARC. The materials and life science facility of J-PARC has 23 neutron beam ports and will start delivering the first neutron beam of 25 Hz from 2008 May. Until now, more than 20 proposals have been reviewed by the review committee, and accepted proposal groups have started to get fund. Those proposals include five polycrystalline diffractometers: a super high resolution powder diffractometer (SHRPD), a 0.2%-resolution powder diffractometer of Ibaraki prefecture (IPD), an engineering diffractometers (Takumi), a high intensity S(Q) diffractometer (VSD), and a high-pressure dedicated diffractometer. SHRPD, Takumi and IPD are being designed and constructed by the joint team of KEK, JAEA and Ibaraki University, whose member are originally from the KEK powder group. These three instruments are expected to start in 2008. VSD is a super high intensity diffractometer with the highest resolution of {delta}d/d = 0.3%. VSD can measure rapid time-dependent phenomena of crystalline materials as well as glass, liquid and amorphous materials. The pair distribution function will be routinely obtained by the Fourier transiformation of S(Q) data. Q range of VSD will be as wide as 0.01 A{sup -1}<Q<100 A{sup -1}. IPD is fully funded by Ibaraki prefecture for the promotion of new industries based on advanced science and technologies. It is for the first time in neutron facilities in Japan that a prefecture owns neutron instruments as well as neutron beam will be provided widely to industrial users. To make it successful, the user system is quite important because those users are expected to use IPD like chemical analyzers in their materials development process. Based on questionnaire data to several hundreds industries, IPD is designed as a versatile diffractometer including texture measurement, small angle scattering and total scattering as well as usual powder diffraction. IPD covers d range 0.15<d(A)<4 with {delta}d/d 0.15%, and covers 4<d(A)<60 with gradually changing resolution. Q range of IPD will be as wide as 0.01 A{sup -1}<Q<50A{sup -1} to be utilized for varieties of structures: local structure, nano structure and crystal structure analyses. Typical measuring time for the typical 'Rietveld-quality' data is several minutes with the sample size of laboratory X-ray: 0.4 cc. SHRPD is designed to be the world highest resolution with {delta}d/d = 0.03% without sacrificing intensity. The combination of the high quality data from HRPD and their high-precision analysis gives us information on tiny structural changes which have been overlooked. After careful examination with the moderator group five years ago, we have decided to develop a high-resolution and good S/N moderator to achieve the 0.03% resolution within 100 m flight path. This development was almost successful up to now. Instrumental simulation and radiation analysis were almost completed. The d range 0.5<d(A)<4 with {delta}d/d = 0.03%, and covers 4<d(A)<45 with gradually changing resolution. Takumi is the first priority instrument in JAEA for stress mapping inside structure materials with the highest resolution of {delta}d/d = 0.2% (corresponding to 10{approx}5 to 10{approx}6 strain precision). The typical gauge volume will be 1 mm3. JED has transmission radiography detectors to support stress mapping. Software group is planning so that basic software to cover data acquisition and data treatment should be common. Since 1 Gbyte data are typically obtained for single experiment in an instrument, the basic software is quite important. International TV conference between ISIS, IPNS, SNS has been held every month to exchange information on each development. KEK developed manyo-lib to help basic analysis. Analysis software development including powder diffraction is strongly related with the activity of the software group. However, users of IPD will be from various field of science and their background is different. It should cover wide topics and help both beginners and well-trained users. We have started with neutron intensity database, peak-search software, peak-match software, pattern simulation, whole pattern fitting, PDF and RDF analysis, and now start coding Rietveld software.

36 MATERIALS SCIENCE↗