Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Experimental investigations of a uranium plasma pertinent to a self-sustaining plasma source

The research is pertinent to the realization of a self-sustained fissioning plasma for applications such as nuclear propulsion, closed cycle MHD power generation using a plasma core reactor, and heat engines such as the nuclear piston engine, as well as the direct conversion of fission energy into optical radiation (nuclear pumped lasers). Diagnostic measurement methods and experimental devices simulating plasma core reactor conditions are discussed. Studies on the following topics are considered: (1) ballistic piston compressor (U-235); (2) high pressure uranium plasma (natural uranium); (3) sliding spark discharge (natural uranium); (4) fission fragment interaction (He-3 and U-235); and (5) nuclear pumped lasers (He-3 and U-235).

Schneider, R. T.↗

N-type mercury-cadmium-telluride photoconductors in optical heterodyne communication systems.

Discussion of the performance of a photoconductive (Hg,Cd)Te detector/mixer in a carbon dioxide laser heterodyne communication system. The utility of computer simulation of the performance of an optical heterodyne detector/mixer is demonstrated. Certain unusual properties of this device are pointed out that, while having a substantial impact on device performance, have received little previous attention.

Cohen, S. C.↗

Computer-generated, calligraphic, full-spectrum color system for visual simulation landing approach maneuvers

The calligraphic chromatic projector described was developed to improve the perceived realism of visual scene simulation ('out-the-window visuals'). The optical arrangement of the projector is illustrated and discussed. The device permits drawing 2000 vectors in as many as 500 colors, all above critical flicker frequencies, and use of high scene resolution and brightness at an acceptable level to the pilot, with the maximum system capabilities of 1000 lines and 1000 fL. The device for generating the colors is discussed, along with an experiment conducted to demonstrate potential improvements in performance and pilot opinion. Current research work and future research plans are noted.

Chase, W. D.↗

Miniature Rotator

Device for making small, precise rotation of objects in cramped spaces consists of V-groove machined in block of aluminum (or nylon) and flat, slotted bar clamped across groove. Device used to rotate lenses until in precise alinement with optical axis of injection laser.

Neil, C. C.↗

Integrated-optical approaches to matrix multiplication

The solution of matrix equations is essential to carrying out a large variety of control algorithms and to reducing certain types of data such as the output of a multispectral sensor array. Optical techniques and, in particular, integrated-optical circuits (IOC's) can provide compact, low-power devices for performing the mitrix multiplications necessary for the solution of these problems. A specific IOC for performing vector-matrix multiplication and several approaches to the design of IOC's for matrix-matrix multiplication will be discussed.

Verber, C. M.↗

Coronagraph for astronomical imaging and spectrophotometry

A coronagraph designed to minimize scattered light in astronomical observations caused by the structure of the primary mirror, secondary mirror, and secondary support structure of a Cassegrainian telescope is described. Direct (1:1) and reducing (2.7:1) imaging of astronomical fields are possible. High-quality images are produced. The coronagraph can be used with either a two-dimensional charge-coupled device or photographic film camera. The addition of transmission dispersing optics converts the coronagraph into a low-resolution spectrograph. The instrument is modular and portable for transport to different observatories.

Vilas, Faith↗

Stabilised electromagnetic levitation at 2-13 MHz

SEL, the Stabilised Electromagnetic Levitator, has been developed to exploit the unique design opportunities available in containerless microgravity experiments. Efficiency and versatility are obtained with multiple coils driven by individual broadband amplifiers whose phase and frequency are controlled. The heating and positioning fields are decoupled. Specimen translation, spin, and for liquids, shape may be adjusted. An open coil structure provides access for optical and diagnostic probes. Results of experiments with a prototype device are discussed. Levitating and heating materials on earth were demonstrated at frequencies up to 13 MHz.

Danley, T. J.↗

Portable dynamic fundus instrument

A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

Taylor, Gerald R.↗

Overview of Terra and Aqua MODIS Status

This presentation will consist of two one-hour lectures. The first lecture will review the characteristics of the MODIS instrument and how it responds to the performance specifications. The pre-launch and on-orbit procedures and results to characterize and maintain instrument output so as to allow the prescribed science to be done will also be outlined. This will include defining the equations used to account for gain changes and any degradation in the optics of the instrument or the on-board calibration devices themselves. The changes in the solar diffuser and the radiance versus scan angle performance of the scan mirror will also be reviewed. Overall it will be shown that the instrument has and is meeting specifications of 2% reflectance relative to the sun, 5% in the radiance observed in the reflected solar radiation bands, and 0.5-1% in the thermal bands. The second lecture will review and describe highlights in the geophysical products and related science results. There are approximately 40 geophysical products related to observations of land, ocean and atmosphere features. Many of the results are unprecedented and offer considerable advances over those achievable with heritage instruments such as the NOAA Advanced Very High Resolution Radiometer (AVHRR). The literature is showing a steady growth of publications in scientific journals using MODIS data or products. The future is also bright in that a follow-on instrument based on the MODIS will be flown on the National Polar-Orbiting Environmental Satellite Series (NPOESS) starting around 2010.

Salomonson, Vincent V.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization of the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 145 mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device multiplexer readout. We describe the design, development, and performance of PIPER bolometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

Alignment Mirror Mechanisms for Space Use

The paper describes an optical Alignment Mirror Mechanism (AMM), and discusses its control scheme. The mirror's angular positioning accuracy requirement is +/- 0.2 arc-sec. This requires the mirror's linear positioning actuators to have a positioning accuracy of +/- 109 nm to enable the mirror to meet the angular tip/tilt accuracy requirement. Demonstrated capabilities are +/- 35 nm linear positioning capability at the actuator, which translates into +/- 0.07 arc-sec angular mirror positioning accuracy.

optical mounts↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗