Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear structure data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Proton Shell Gaps in N = 28 Nuclei from the First Complete Spectroscopy Study with FRIB Decay Station Initiator

The first complete measurement of the $β$-decay strength distribution of $_{17}^{45}$Cl 28 was performed at the Facility for Rare Isotope Beams (FRIB) with the FRIB Decay Station Initiator during the second FRIB experiment. The measurement involved the detection of neutrons and $γ$ rays in two focal planes of the FRIB Decay Station Initiator in a single experiment for the first time. This enabled an analytical consistency in extracting the $β$-decay strength distribution over the large range of excitation energies, including neutron unbound states. Here, we observe a rapid increase in the $β$-decay strength distribution above the neutron separation energy in $_{18}^{45}$Ar 27 . This was interpreted to be caused by the transitioning of neutrons into protons excited across the Z = 20 shell gap. The SDPF-MU interaction with reduced shell gap best reproduced the data. The measurement demonstrates a new approach that is sensitive to the proton shell gap in neutron rich nuclei according to SDPF-MU calculations.

39 ≤ A ≤ 58↗

Assessing tension metrics with dark energy survey and Planck data

ABSTRACT Quantifying tensions – inconsistencies amongst measurements of cosmological parameters by different experiments – has emerged as a crucial part of modern cosmological data analysis. Statistically significant tensions between two experiments or cosmological probes may indicate new physics extending beyond the standard cosmological model and need to be promptly identified. We apply several tension estimators proposed in the literature to the dark energy survey (DES) large-scale structure measurement and Planck cosmic microwave background data. We first evaluate the responsiveness of these metrics to an input tension artificially introduced between the two, using synthetic DES data. We then apply the metrics to the comparison of Planck and actual DES Year 1 data. We find that the parameter differences, Eigentension, and Suspiciousness metrics all yield similar results on both simulated and real data, while the Bayes ratio is inconsistent with the rest due to its dependence on the prior volume. Using these metrics, we calculate the tension between DES Year 1 3 × 2pt and Planck, finding the surveys to be in ∼2.3σ tension under the ΛCDM paradigm. This suite of metrics provides a toolset for robustly testing tensions in the DES Year 3 data and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

𝛽−decay of neutron-rich 45 Cl located at the magic number 𝑁 = 28

Results from the β-decay study of 45 Cl, produced in the fragmentation of a 140-MeV/u 48 Ca beam, are presented. The half-life of 45 Cl is measured to be 513(36) ms. β – and β – 1n decay populate excited states in 45 Ar and 44 Ar, respectively, and decay schemes for both daughter nuclei are established based on γ-ray singles and γ-γ coincidence data. Comparison with shell-model calculations using the FSU interaction shows that the low-lying negative-parity states in 45 Ar are well described by single-neutron configurations near the Fermi surface, whereas positive-parity states require neutron excitations across the N = 20 shell gap, consistent with allowed Gamow–Teller decay from 45 Cl. The strong β-feeding to the 5/2 + state in 45 Ar supports a 3/2 + ground-state assignment for 45 Cl over 1/2 + . Furthermore, the high Q β – value enables population of 1p1h states above the neutron separation energy in 45 Ar, leading to positive-parity states in 44 Ar through neutron emission. Tentative spin-parity assignments for excited levels in 44 Ar are made for the first time based on comparison with shell-model predictions, and the 2978-keV level is identified as an excited 0 + state with a configuration distinct from the ground state.

39 ≤ A ≤ 58↗

Status and future plans for C 3 R&D

C 3 is an opportunity to realize an e + e - collider for the study of the Higgs boson at √s = 250 GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C 3 is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C 3 is the main linac. This paper presents the staged approach towards a facility to demonstrate C 3 technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The primary goal of the C 3 Demonstration R&D Plan is to reduce technical and cost risk by building and operating the key components of C 3 at an adequate scale. This R&D plan starts with the engineering design, and demonstration of one cryomodule and will culminate in the construction of a 3 cryomodule linac with pre-production prototypes. This R&D program would also demonstrate the linac rf fundamentals including achievable gradient and gradient stability over a full electron bunch train and breakdown rates. It will also investigate beam dynamics including energy spread, wakefields, and emittance growth. This work will be critical to confirm the suitability of the C 3 beam parameters for the physics reach and detector performance in preparation for a Conceptual Design Report (CDR), as well as for follow-on technology development and industrialization. The C 3 Demonstration R&D Plan will open up significant new scientific and technical opportunities based on development of high-gradient and high-efficiency accelerator technology. It will push this technology to operate both at the GeV scale and mature the technology to be reliable and provide high-brightness electron beams. The timeline for progressing with C 3 technology development will be governed by practical limitations on both the technical progress and resource availability. It consists of four stages: Stage 0) Ongoing fundamental R&D on structure prototypes, damping and vibrations. Stage 1) Advancing the engineering maturity of the design and developing start-to-end simulations including space-charge and wakefield effects. This stage will include testing of strucutres operating at cryogenic temperatures. Beam tests would be performed with high beam current to test full beam loading. Stage 2) Production and testing of the first cryomodule at cryogenic temperatures. This would provide sufficient experimental data to compile a CDR and it is anticipated for Stage 2 to last 3 years and to culminate with the transport of photo-electrons through the first cryomodule. Stage 3) Updates to the engineering design of the cryomodules, production of the second and third cryomodule and their installation. Lower charge and lower emittance beams will be used to investigate emittance growth. The successful full demonstration of the 3 cryomodules to deliver up to a 3 GeV beam and achieve the C 3 five gradient will allow a comprehensive and robust evaluation of the technical design of C 3 as well as mitigate technical, schedule, and cost risks required to proceed with a Technical Design Report (TDR).

radiation hardened magnets↗

Boron Coordination in Multicomponent Glasses: Analytical Models and Machine Learning With Uncertainty

Borosilicate glasses are extensively used in a variety of applications from kitchenware to nuclear waste immobilization due to the strong network formed by the Si-O-B bond that makes it resistant to chemical corrosion and gives it a low thermal expansion. Boron, however, exists in both trigonal BO3 and tetrahedral BO4 bonds in glass systems, which impacts the chemical durability and thermal resistance of the glass, amongst other properties. Boron coordination (N4), or the ratio of the amount of BO4 to BO3 within a glass, may aid in predicting these properties but is difficult to derive without experimental data due to the complexity of impacts from varied glass compositions and processing factors. For this reason, compositional models have been developed to predict boron coordination, but the models typically include a limited number of glass components. To help fill this gap in the models, in this work, a diverse multicomponent glass dataset of 809 glasses is compiled from a literature search, and then a number of analytical and machine learning (ML) models are trained on the dataset. Previously developed modified Bernstein and modified Du Stebbins analytical models were fitted to update parameters with the new dataset. Then, partially Bayesian neural networks, Gaussian process regressor, and heteroskedastic deterministic neural networks were evaluated. The ML models examined all have different strategies to overcome the potential for overfitting as a result of a limited training dataset, and return results that account for model uncertainty, which can be valuable for understanding model reliability. For the first time, cooling rate is introduced as an input parameter for ML models, showing consistent improvements in performance and solidifying the importance of including parameters outside of composition alone for N4 prediction. The machine learning models examined here show promise in accurate predictions of boron coordination in borosilicate glasses, all achieving R2 values of 0.91.

boron coordination↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mass spectrometric investigations into 3D printed parts to assess radiopurity as ultralow background materials for rare event physics detectors

The mass concentrations of 232 Th and 238 U in several 3D printing filaments and printed polymer parts are reported as measures of their radiopurity. In order to minimize background signals in rare event physics detectors, radiopure polymers are necessary as dielectric and structural materials in their construction. New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 pg g -1 for 232 Th and 238 U, respectively, while a more complex spring clip part had slightly elevated 232 Th levels of 65 pg g -1 , with 238 U remaining at 50 pg g -1 . PPS filament was found to have concentrations of 270 and 710 pg g -1 for 232 Th and 238 U, respectively, and were not chosen to be printed as those levels were already higher than other material options. ULTEM 1010 filaments and printed complex spring clip parts were found to have concentrations of around 5 and 7 pg g -1 for 232 Th and 238 U, respectively, illustrating no significant contamination from the printing process. ULTEM 9085 filaments were found to have concentrations of around 9 and 5 pg g -1 for 232 Th and 238 U, respectively, while the printed complex spring clip part was found to have slightly elevated concentrations of 25 and 7 pg g -1 for 232 Th and 238 U, respectively. All these results were obtained using a novel dry ashing method in crucibles constructed of ultralow background electroformed copper or, when applicable, microwave assisted wet ashing digestion. Samples and process blanks were spiked with 229 Th and 233 U as internal standards prior to dry/wet ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). In order to maintain high radiopurity levels, pre-cleaning the filaments before printing and post-cleaning the parts is recommended, although the printing process itself has shown to contribute very minute amounts of radiocontaminants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Exploring competitive metal binding and crystallization of UO 2 2+ and Cu 2+ tetrahydrofuran-2,3,4,5-tetracarboxylic acid complexes

Solvent extractions are used to separate actinide elements from fission products in nuclear waste streams and the successful isolation of specific species utilize subtle differences in metal ligand binding. Metal ligand binding is also important in crystallization of metal organic materials and herein we explore the importance of competitive binding in the tetrahydrofuran-2,3,4,5-tetracarboxylic acid (THFTCA) system. This ligand has been previously evaluated for the selective extraction of uranium from other lanthanides and actinides and in the current research, we evaluate the crystallization of uranyl-THFTCA complexes in the presence of Cu 2+ , Sr 2+ , Th 4+ , and Ce 3+ . Three major phases were formed in the crystallization experiments and characterized with single crystal X-ray diffraction, powder X-ray diffraction, thermogravimetric analysis, and Raman spectroscopy. Two of the resulting phases were novel (UTHF1 ((C 4 H 10 N 2 )[UO 2 (C 8 H 8 O 9 ) 2 ]∙2H 2 O) and UTHF2 (Na[(UO 2 )(C 8 H 5 O 9 )(H 2 O)]∙ 3.5 H 2 O)), whereas the third (CuTHF1) was previously reported in the literature. Raman spectroscopy was utilized to evaluate spectral changes in the mother liquor of UTHF1, UTHF2, and CuTHF1 over time to assess the crystallization process. Further, isothermal titration calorimetry was used to determine the binding constants for UO 2 2+ and Cu 2+ to the THFTCA ligand in solution and evaluate the role of competitive metal binding in this system. The thermodynamic parameters and the crystallographic data were used to justify the formation of a weaker UO 2 2+ -THFTCA complex. Formation of a weaker UO 2 2+ -THFTCA complex supports our findings that UTHF1 only forms in homomeric systems, but suggests that the crystallization of UTHF2 and CuTHF1 is reliant on the presence of additional counter ions and ligands to change the amount of available THFTCA ligand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Compton Scattering at MAMI for the Extraction of the Electric and Magnetic Polarizabilities of the Proton

A precise measurement of the differential cross sections dσ/dΩ and the linearly polarized photon beam asymmetry Σ 3 for Compton scattering on the proton below pion threshold has been performed with a tagged photon beam and almost 4π detector at the Mainz Microtron. The incident photons were produced by the recently upgraded Glasgow-Mainz photon tagging facility and impinged on a cryogenic liquid hydrogen target, with the scattered photons detected in the Crystal Ball/TAPS setup. Using the highest statistics Compton scattering data ever measured on the proton along with two effective field theories (both covariant baryon and heavy-baryon) and one fixed-t dispersion relation model, constraining the fits with the Baldin sum rule, we have obtained the proton electric and magnetic polarizabilities with unprecedented precision: α E1 = 10.99 ± 0.16 ± 0.47 ± 0.17 ± 0.34, β M1 = 3.14 ± 0.21 ± 0.24 ± 0.20 ± 0.35; in units of 10 -4 fm 3 where the errors are statistical, systematic, spin polarizability dependent, and model dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The study of C-13(a, n)O-16 reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied 13C(a, n)1640 O reactions induced by a-particles emitted within the calibration sources of the Majorana Demonstrator. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129 keV ?-rays emitted from the excited 1643 O states that are populated when the incoming a-particles have enough energy. Thanks to the excellent energy performance of the Demonstrator’s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by Geant4 simulations, a comparison between the observed 6129 keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent with each other, albeit with large statistical uncertainties. This agreement provides supports for further background predictions for (a, n)-reactions in future double-beta decay search efforts.

6 ≤ A ≤ 19↗

The molten salt tritium transport experiment: A pumped fluoride salt loop for hydrogen isotope experimentation

Molten salt reactors (MSRs) and fusion reactors propose to use molten salts as coolants and breeder blanket materials, respectively. Tritium, however, poses safety concerns in both reactor types due to its ability to permeate through reactor materials and potential for environmental release. This manuscript addresses the tritium transport phenomena in molten salts and presents the design and analysis of the Molten Salt Tritium Transport Experiment (MSTTE). MSTTE is a forced-convection fluoride salt loop intended to measure hydrogen isotope permeation through structural materials in a flowing salt system. In the first phase, MSTTE will use FLiNaK salt and deuterium as surrogates for FLiBe and tritium, with future plans to utilize tritium and FLiBe. MSTTE couples a Copenhagen Atomics pumped salt loop with an external test section that introduces hydrogen isotopes into the loop and measures transport phenomena. The Hydrogen Injection System (HIS) controls hydrogen isotope introduction into the molten salt loop. Here, the permeation test section measures the permeation rate through stainless steel tubing in contact with flowing salt. Computational fluid dynamics (CFD) analysis ensures fully developed salt flow in the permeation test section. MSTTE is modeled with MELCOR-TMAP to predict the permeation rate as a function of experimental variables such as source term, salt flow rate, and salt temperature. Results indicate that the source term is the only parameter with a significant effect on the permeation rate. Pressure drop analysis suggests that the loop should operate below 200 LPM to maintain a pressure drop below 200 kPa. Additionally, finite-element analysis assesses thermal stress during loop operation to ensure the experiment's safe design. MSTTE will provide semi-integral data on tritium transport phenomena in molten salts and serve as a testbed for advancing molten salt technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses

VENTSAR: Originated as VENTAX (Smith and Weber 1983) on the IBM Mainframe at the Savannah River Site (SRS) as a Fortran program. Updated to VENTSAR XL V1.0 (Simpkins 1997) as a spreadsheet version using macros created in Microsoft Excel. Later updated to VENTSAR XL V2.0 (Dixon 2018) as a spreadsheet executing a modified version of the original VENTAX Fortran code. Estimates contaminant concentrations on or near a building from a release at a nearby location. Calculates concentrations for a given meteorological exceedance probability or for a given stability and wind speed combination. Can model a single building with or without a penthouse on top or a ground location from either a stack or ground release. Plume rise can be considered. Contaminant releases can be chemical or radioactive with downwind concentrations determined at user-specified distances. Wind passing over and around buildings creates a complicated dispersion pattern. Air-intake vents may be located on building roofs or near the ground downwind of a release source. An estimation of pollutant concentrations on or near a structure is important in determining expected pollutant levels. Meteorological data are selected based on a specific area of the site. Fortran-based VENTAX able to make fast, complex mathematical calculations. Not user-friendly VENTSAR XL V1.0 no longer supported due to obsolete Excel macros. VENTSAR XL V2.0 an interim solution using an Excel spreadsheet to interface with the modified VENTAX Fortran code. Requires user to have Microsoft Excel. Not an intuitive interface for someone unfamiliar with VENTSAR. Does not perform dose calculations. VENTSAR V3.0 goal to combine the strengths of previous versions of VENTSAR into a single, powerful yet user-friendly program with a Graphical User Interface (GUI). Not dependent upon a specific program or plug-ins. Self-contained package to be used on any computer running Microsoft Windows. User-friendly, intuitive GUI created in Python for parameter input. Executes same modified VENTAX Fortran code as VENTSAR XL V2.0. Outputs formatted text file of completed calculations for easy review and dissemination. Performs inhalation and plume shine dose calculations for up to 11 user-selected nuclides from a nuclide dose factor library of almost 500 nuclides. 12 test cases were created for verification of V1.0 and V2.0. Same test cases run in V3.0 to verify correct performance. V3.0 produced similar results to V1.0. Confirmed GUI did not alter calculations in any way. Comparisons of the test case results confirm the V3.0 GUI does not influence the VENTSAR calculations. Simply passes same input parameters to VENTAX Fortran code for execution. Provides end user an easy-to-use, intuitive tool to quickly make building effect and plume rise calculations, as well as, inhalation and plume shine dose calculations. No experience with or working knowledge of Fortran, Excel, command line, or macros required. Self-contained package allows VENTSAR be deployed to any Windows computer without the need for specific programs or plug-ins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exclusive π 0 p electroproduction off protons in the resonance region at photon virtualities 0.4 GeV 2 ≤ Q 2 ≤ 1 GeV 2

The limited electroproduction process e p → e ' p ' π 0 was measured in the range of photon virtualities Q 2 = 0.4 – 1.0 GeV 2 and the invariant mass range of the p π 0 system of W = 1.1 – 1.8 GeV. These kinematics are covered in exclusive π 0 electroproduction off the proton with nearly complete angular coverage in the p π 0 center-of-mass system and with high statistical accuracy. Nearly 36 000 cross-section points were measured, and the structure functions σ T + ε σ L , σ L T , and σ T T , were extracted via fitting the φ π 0 dependence of the cross section. A Legendre polynomial expansion analysis demonstrates the sensitivity of our data to high-lying N * and Δ * resonances with M > 1.6 GeV. As part of a broad effort to determine the electrocouplings of the N * and Δ * resonances using both single- and double-pion electroproduction, this dataset is key for the reliable extraction of the high-lying resonance electrocouplings from the combined isospin analysis of the N π and π + π - p channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding Model Inadequacy in TRISO Nuclear Fuel Fission Products Release Models: Empirical and Mechanistic Approaches

The increasing use of tristructural isotropic (TRISO) particle fuel in both advanced and existing reactors necessitates a thorough evaluation of uncertainties and shortcomings in TRISO fission product release models. These inadequacies arise from the simplifications made in computational models compared to experimental data. Utilizing the BISON fuel performance code and experimental data from the Advanced Gas Reactor (AGR) program provides a unique chance to rigorously assess these inadequacies within a Bayesian uncertainty quantification (UQ) framework. This study contrasts the standard Bayesian framework with the Kennedy-O'Hagan (KOH) framework, which explicitly accounts for modeling inadequacies, in the context of UQ for TRISO silver release models. It examines both the traditional Arrhenius equation and a more advanced lower-length-scale (LLS)-informed model that incorporates microstructure information. The inverse UQ process applied to AGR-2 and AGR-3/4 datasets identified modeling inadequacy as the primary source of uncertainty, with experimental noise also being significant, while model parameter uncertainty was minimal. Both the Arrhenius and LLS-informed models showed similar levels of modeling inadequacy. For forward predictive UQ using the AGR-1 dataset, the KOH framework enhanced the accuracy and quality of quantified uncertainties by approximately 30% and 40%, respectively, compared to the standard Bayesian framework. This improvement was observed for both the Arrhenius and LLS-informed models. At the engineering scale, both models performed similarly, but the LLS-informed model outperformed the Arrhenius equation at the mesoscale. These findings underscore the importance of explicitly considering modeling inadequacy in the UQ process and highlight the need for ongoing refinement of physics-based models to address these shortcomings.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resonant inelastic X-ray scattering tools to count 5 $f$ electrons of actinides and probe bond covalency

The actinides possess a complex electronic structure, making their chemical and physical properties among the least understood in the periodic table. Advanced spectroscopic tools, able to obtain deep insights into the electronic structure and binding properties of the actinides, are highly desirable. Here, we introduce two sensitive spectroscopic tools: one determines the number of localized 5f electrons on an actinide atom, and another assesses the covalent character of actinide-ligand bonding. Both tools are based on the multiplet structure present in actinide M 4 edge core-to-core resonant inelastic X-ray scattering (CC-RIXS) maps. The spectral intensity of different many-body final-state multiplets directly depends on the local many-electron ground-state symmetry including the local 5 f spin configuration. By comparing U M 4 edge CC-RIXS data for 21 U, Np, Pu and Am compounds, we demonstrate the ability to compare the number of localized 5 f electrons and bond covalency across the actinide series.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Observation of Forward Neutron Multiplicity Dependence of Dimuon Acoplanarity in Ultraperipheral Pb-Pb Collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The first measurement of the dependence of $γγ → μ^+μ^–$ production on the multiplicity of neutrons emitted very close to the beam direction in ultraperipheral heavy ion collisions is reported. Data for lead-lead interactions at $\sqrt{s_{NN}}$ = 5.02 TeV, with an integrated luminosity of approximately 1.5 nb –1 , are collected using the CMS detector at the LHC. The azimuthal correlations between the two muons in the invariant mass region 8 < $m_{μμ}$ < 60 GeV are extracted for events including 0, 1, or at least 2 neutrons detected in the forward pseudorapidity range |η| > 8.3. The back-to-back correlation structure from leading-order photon-photon scattering is found to be significantly broader for events with a larger number of emitted neutrons from each nucleus, corresponding to interactions with a smaller impact parameter. This observation provides a data-driven demonstration that the average transverse momentum of photons emitted from relativistic heavy ions has an impact parameter dependence. These results provide new constraints on models of photon-induced interactions in ultraperipheral collisions. They also provide a baseline to search for possible final-state effects on lepton pairs caused by traversing a quark-gluon plasma produced in hadronic heavy ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗