Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Spectral-average cross section validation in LR-0 reactor spectrum of {sup 55}Mn(n,2n), {sup 90}Zr(n,2n) and {sup 127}I(n,2n) reactions - 25362

This article deals with the validation of spectral average cross-sections (SACS) of {sup 55}Mn(n,2n){sup 54}Mn, {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions in well-defined LR-0 reactor spectrum. The measurement of SACS for selected reactions is of high interest because they are used for the practical reactor dosimetry and also for refinement of prompt fission neutron spectra of {sup 235}U in the region of higher energies. Various experiments for description of neutron field in reactor and detector characterization, which are necessary for validation, are described. The spectral average cross-sections are derived from Net Peak Areas of irradiated samples measured using a semiconductor high purity germanium detector. The spectral average cross section in {sup 235}U prompt fission neutron spectrum was experimentally determined to be 0.239 ± 0.015 mb for {sup 55}Mn, 1.209 ± 0.052 mb for {sup 127}I and 0.107 ± 0.005 mb for {sup 90}Zr. The obtained results were compared with MCNP6 calculations using ENDF/B-VII.0, ENDF/B-VII.1, JEFF-3.1, JEFF-3.2, JENDL-3.3, JENDL-4, ROSFOND-2010, CENDL-3.1 and IRDFF-1.05 nuclear data libraries. Notable discrepancies were found in {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Container inspection in the port container terminal by using 14 MeV neutrons

A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

42 ENGINEERING↗

Noble Gas Excimer Detectors for Security and Safeguards Applications

Noble gas excimer detectors are a technology that is common in particle physics research and less common in applications for security and international safeguards. These detectors offer the capability to detect gammas with an energy resolution similar to NaI and to detect neutrons with good energy resolution as well. Depending on the noble gas selected and whether or not it is in a gaseous or liquid state, the sensitivity to gammas and neutrons can be tuned according to the needs of the application. All of this flexibility can be available at a significant cost saving over alternative technologies. This paper will review this detector technology and its applicability to security and safeguards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt fission gamma-ray studies at DANCE

Measurements of correlated data on prompt-fission γ-rays (PFG) have been carried out for various actinide isotopes in recent years using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL). We have developed a model that conveniently parametrizes the correlated data of γ-ray multiplicity and energy. New results on two- dimensional prompt-fission γ-ray multiplicity versus energy distributions from spontaneous fission on ²⁵²Cf and neutron-induced fission on 242m Am are presented together with previously obtained results on 233,235 U and ²³⁹Pu. Correlated PFG data from ²⁵²Cf are also compared to results of the detailed theoretical model developed at LANL, for different thresholds of PFG energies. Future plans to measure correlated data on fission fragments, prompt fission neutrons and γ-rays at DANCE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

Past 3He shortages led to investigations into replacement options for neutron detectors in systems that previously used 3He-based technologies. The goal of this research was to investigate the feasibility of a full-scale lithium fluoride with silver activated zinc sulfide (LiF/ZnS) based neutron multiplicity counter. The LiF/ZnS based neutron multiplicity counter (LiNMC) was developed based on an iterative process between modeling and experimental measurements. Each active region of the LiNMC contains five sheets of LiF/ZnS sandwiched between six sheets of wavelength shifting plastic to form neutron detection stacks. The wavelength shifted scintillation light was collected by photomultiplier tubes located on each end of the stacks. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high density polyethylene blocks in the corners to reflect high energy neutrons and capture low energy neutrons. Preliminary calibration with a 252Cf neutron source showed that the LiNMC was able to achieve 36% neutron detection efficiency (ε) and an 11.7 μs neutron die-away time (τ) for a doubles Figure-of-merit (ε2/ τ) of 109. This is the highest doubles Figure-of-merit performance measured to-date for a 3He-free neutron multiplicity counter system. By the end of this project, the LiNMC’s basic components were integrated into a single laboratory scale system capable of proof-of-concept measurements.

3He-free↗

Fast neutron activation of ubiquitous materials

Nuclear explosions expose ubiquitous materials to large numbers of neutrons, producing a variety of radioactive isotopes. To simulate such phenomena from both fission and thermonuclear explosions, we irradiated 29 different targets with approximately 3 and 14 MeV neutrons and measured the beta-delayed gamma rays using germanium detectors. Therefore, for each neutron energy, the expected radioisotopes, half-lives, and gamma ray energies were deduced. From measurements of the ratios of activities of the radionuclides produced by neutron irradiations, we were able to identify several materials that are particularly sensitive to the neutron energy spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Performance of the CMS Zero Degree Calorimeters in pPb collisions at the LHC

The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at ± 140 m from the collision point and detect neutral particles in the |η| > 8.3 pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron-deuteron analyzing power data at 19.0 MeV

Measurements of neutron-deuteron (n-d) analyzing power A{sub y}(theta) at E{sub n}=19.0 MeV are reported at 16 angles from theta{sub c.m.}=46.7 to 152.0 deg. The objective of the experiment is to better characterize the discrepancies between n-d data and the predictions of three-nucleon calculations for neutron energies above 16.0 MeV. The experiment used a shielded neutron source, which produced polarized neutrons via the {sup 2}H(d-vector,n-vector){sup 3}He reaction, a deuterated liquid scintillator center detector (CD) and liquid-scintillator neutron side detectors. A coincidence between the CD and the side detectors isolated the elastic-scattering events. The CD pulse height spectrum associated with each side detector was sorted by using pulse-shape discrimination, time-of-flight techniques, and by removing accidental coincidences. A Monte Carlo computer simulation of the experiment accounted for effects due to finite geometry, multiple scattering, and CD edge effects. The resulting high-precision data (with absolute uncertainties ranging from 0.0022 to 0.0132) have a somewhat lower discrepancy with the predictions of three-body calculations, as compared to those found at lower energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Materials characterisation with the associated particle technique

Since the last past years, the Nuclear Measurement Laboratory of CEA Cadarache, France, together with Partners from European and National projects, has been studying the application of fast neutron interrogation with the Associated Particle Technique for material identification in different areas of homeland and maritime security, and for the characterisation of the materials constituting radioactive waste. Fast 14 MeV neutrons are produced from the H-3(H-2,n)alpha fusion reaction in a sealed tube neutron generator embedding an alpha detector. The alpha particle is used to tag neutron direction and emission time, thus allowing the electronic selection of neutron-induced gamma spectra in the voxels of interest. Gamma rays emitted by tagged neutron interactions on the present nuclei (C, O, N, Fe, Al, Si, Cl, etc.) are recorded with spectroscopic detectors and analysed to determine elemental proportions, thus allowing material identification. Investigations have been conducted for the detection of explosives, illicit drugs and contraband materials in cargo containers, for the inspection of objects lying on the sea floor suspected to contain explosives like mines, bombs, torpedoes, etc., for the recognition of an improvised chemical device, and for material identification in radioactive waste packages. Recently the detection of special nuclear materials is being investigated using time correlation analysis between induced fission particles, instead of gamma-ray spectroscopy. The paper presents an overview of these studies and last results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum 252Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is 4.8+0.7-0.9% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at ~4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to ~75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

dark matter, detector calibration, ionization yiel↗

Experimental study for subcriticality measurement of fuel debris in the Fukushima Daiichi reactor - 14582

Fuel debris defueling in the Fukushima Daiichi reactors is planned. Furthermore, retrieved fuel debris will be packed and stored in casks for a long time. In these processes, from the viewpoint of criticality safety, the subcriticality of the fuel debris should be confirmed. Although there are some subcriticality measurement methods, the applicability of these methods to the fuel debris must be investigated because the elemental composition and shape of the fuel debris are unknown. In this study, we focus on the exponential experiment method which is able to measure a wide range of subcriticality. Basic experiments to validate the methods were carried out using Toshiba Nuclear Critical Assembly (NCA) and {sup 3}He Position Sensitive Detector (PSD). The decay curves of neutron flux distributions were measured by the PSD detector and fitted to a theoretical formula. The elemental compositions and neutron spectrum of the fuel debris have been estimated with a severe accident code and a Monte Carlo code. In the experiment, the neutron spectrum of the fuel debris was simulated in the NCA core. The porosity of the fuel debris was assumed to be 60%, which corresponds to be H/U=7.5 and Volume Ratio=1.5. In order to evaluate the effect of the uncertainty of the compositions on the measured subcriticality, a homogeneous region and a heterogeneous region were configured in an experimental core. These regions consisted of fuel rods with different UO{sub 2} enrichment zone or different gadolinia concentration zone in the axial direction. The effective multiplication factors deduced by the exponential experiment method were a range of 0.94 to 0.98. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Lead and Bismuth (n,gamma) Cross Sections and Their Astrophysical Impact

A series of (n,{gamma}) neutron capture measurements on the lead isotopes and bismuth have been carried out at the CERN n{_}TOF installation in the neutron energy range from 1 eV up to 1 MeV. At n TOF, contaminations due to scattered neutrons were reduced down to a negligible level by using improved {gamma}-ray detectors with very low neutron sensitivity. The background level has been determined precisely from a complementary measurement. Other experimental effects related to the electronic threshold in the detectors and the angular distribution of the prompt {gamma}-rays were investigated via Monte Carlo simulations and could be taken in account in the analysis of the capture data. With this set of measurements the energy differential (n,{gamma}) cross sections of {sup 204,206,207}Pb and {sup 209}Bi have been determined with good accuracy. The information obtained in this work becomes of interest for constraining r-process calculations and in particular for the Th/U cosmochronometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling interactions of intermediate-energy neutrons in a plastic scintillator array with Geant4

Here, a Monte Carlo simulation of a large-area neutron time-of-flight detector, built on the Geant4 framework, has been compared with an experimental measurement of the 16 B → 15 B + n decay produced from a 55 MeV/ u 17 C beam. The ability of the Monte Carlo simulation to reproduce the intermediate-energy neutron interactions within the detector has been explored using both the stock Geant4 physics processes and a custom neutron interaction model, menate_r. The stock Geant4 physics processes were unable to reproduce the experimental observables, while excellent agreement was obtained through the inclusion of the menate_r model within Geant4. The differences between the two approaches are shown to be related to the modeling of the neutron–carbon inelastic reactions. Additionally, the use of menate_r provided accurate reproduction of experimental signals associated with neutron scattering within the detector. These results provide validation of the Monte Carlo simulation for modeling measurements of multiple neutrons where the identification and removal of false neutron signals, due to multiple neutron scattering, are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗