Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Quantification and mapping of urban fluxes under climate change: Application of WRF-SUEWS model to Greater Porto area (Portugal)

Climate change and the growth of urban populations are two of the main challenges facing Europe today. These issues are linked as climate change results in serious challenges for cities. Recent attention has focused on how urban surface-atmosphere exchanges of heat and water will be affected by climate change and the implications for urban planning and sustainability. In this study energy fluxes for Greater Porto area, Portugal, were estimated and the influence of the projected climate change evaluated. To accomplish this, the Weather Research and Forecasting Model (WRF) and the Surface Urban Energy and Water Balance Scheme (SUEWS) were applied for two climatological scenarios: a present (or reference, 1986–2005) scenario and a future scenario (2046–2065), in this case the Representative Concentration Pathway RCP8.5, which reflects the worst set of expectations (with the most onerous impacts). The results show that for the future climate conditions, the incoming shortwave radiation will increase by around 10%, the sensible heat flux around 40% and the net storage heat flux around 35%. In contrast, the latent heat flux will decrease about 20%. The changes in the magnitude of the different fluxes result in an increase of the net all-wave radiation by 15%. The implications of the changes of the energy balance on the meteorological variables are discussed, particularly in terms of temperature and precipitation. - Highlights: • Assessment of energy fluxes behaviour under past period and medium-term climate change projection. • Evaluation of climate change at urban scale. • Meteorological variables alters the partitioning of the energy fluxes. • Changes in the partition of the annual energy balance are found between the two analysed periods. • Increase in the magnitude of sensible and storage heat fluxes.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning Eliminates Reanalysis Warm Bias and Reveals Weaker Winter Surface Cooling Over Arctic Sea Ice

The surface energy budget governs Arctic sea-ice growth/melt, yet observations are sparse, and reanalysis data sets suffer from systematic biases. Here, we train a neural network with observational data to bias-correct hourly ERA5 fluxes over Arctic ice-covered regions (≥70°N; sea-ice concentration >80%) for 1994–2024. Training data cover two full seasonal cycles and different sea-ice regimes. The neural network reduces RMSE for net shortwave radiation by ∼40%, downward longwave radiation by ∼16% and the total surface energy budget by ∼55%, eliminating the wintertime warm bias of ∼4 K in ERA5. Wintertime surface cooling is reduced by ∼50%, yielding thermodynamic ice-growth estimates of ∼80–120 cm, consistent with SMOS–CryoSat satellite thickness increases and in contrast to the 150–200 cm growth implied by ERA5. Our bias-corrected data capture the observed clear/cloudy states of the winter boundary layer and can be used to study Arctic climatology, evaluate climate models and drive sea-ice-ocean models.

Hossain, Akil [Alfred Wegener Institute for Polar ↗

Application of Monte Carlo techniques to transient thermal modeling of cavity radiometers having diffuse-specular surfaces

A viable alternative to the net exchange method of radiative analysis which is equally applicable to diffuse and diffuse-specular enclosures is presented. It is particularly more advantageous to use than the net exchange method in the case of a transient thermal analysis involving conduction and storage of energy as well as radiative exchange. A new quantity, called the distribution factor is defined which replaces the angle factor and the configuration factor. Once obtained, the array of distribution factors for an ensemble of surface elements which define an enclosure permits the instantaneous net radiative heat fluxes to all of the surfaces to be computed directly in terms of the known surface temperatures at that instant. The formulation of the thermal model is described, as is the determination of distribution factors by application of a Monte Carlo analysis. The results show that when fewer than 10,000 packets are emitted, an unsatisfactory approximation for the distribution factors is obtained, but that 10,000 packets is sufficient.

Mahan, J. R.↗

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗

Battery Energy Storage Scheduling for Optimal Load Variance Minimization

Generation portfolio can be significantly altered due to the deployment of distributed energy resources (DER) in distribution networks and the concept of microgrid. Generally,distribution networks can operate in a more resilient and economic fashion through proper coordination of DER. However, due to the partially uncontrollable and stochastic nature of some DER, the variance of net load of distribution systems increases, which raises the operational cost and complicates operation for transmission companies. This motivates peak shaving and valley filling using energy storage units deployed in distribution systems. This paper aims at theoretical formulation of optimal load variance minimization, where the infinity norm of net load is minimized. Then, the problem is reformulated equivalently as a linear program. A case study is performed with capacity limited battery energy storage model and the simplified power flow model of a radial distribution network. The influence of capacity limit and deployment location are studied.

Melin, Alexander↗

Efficient electrochemical CO 2 conversion powered by renewable energy

Here, the catalytic conversion of CO 2 into industrially relevant chemicals is one strategy for mitigating greenhouse gas emissions. Along these lines, electrochemical CO 2 conversion technologies are attractive because they can operate with high reaction rates at ambient conditions. However, electrochemical systems require electricity, and CO 2 conversion processes must integrate with carbon-free, renewable-energy sources to be viable on larger scales. We utilize Au 25 nanoclusters as renewably powered CO 2 conversion electrocatalysts with CO 2 → CO reaction rates between 400 and 800 L of CO 2 per gram of catalytic metal per hour and product selectivities between 80 and 95%. These performance metrics correspond to conversion rates approaching 0.8–1.6 kg of CO 2 per gram of catalytic metal per hour. We also present data showing CO 2 conversion rates and product selectivity strongly depend on catalyst loading. Optimized systems demonstrate stable operation and reaction turnover numbers (TONs) approaching 6 × 10 6 mol CO 2 molcatalyst–1 during a multiday (36 hours total hours) CO 2 electrolysis experiment containing multiple start/stop cycles. TONs between 1 × 10 6 and 4 × 10 6 molCO 2 molcatalyst–1 were obtained when our system was powered by consumer-grade renewable-energy sources. Daytime photovoltaic-powered CO 2 conversion was demonstrated for 12 h and we mimicked low-light or nighttime operation for 24 h with a solar-rechargeable battery. This proof-of-principle study provides some of the initial performance data necessary for assessing the scalability and technical viability of electrochemical CO 2 conversion technologies. Specifically, we show the following: (1) all electrochemical CO 2 conversion systems will produce a net increase in CO 2 emissions if they do not integrate with renewable-energy sources, (2) catalyst loading vs activity trends can be used to tune process rates and product distributions, and (3) state-of-the-art renewable-energy technologies are sufficient to power larger-scale, tonne per day CO 2 conversion systems.

30 DIRECT ENERGY CONVERSION↗

Fabrication of nanopores in a graphene sheet with heavy ions: A molecular dynamics study

Molecular dynamics simulations were performed to study the formation process of nanopores in a suspended graphene sheet irradiated by using energetic ions though a mask. By controlling the ion parameters including mass, energy, and incident angle, different kinds of topography were observed in the graphene sheet. Net-like defective structures with carbon atom chains can be formed at low ion fluences, which provide the possibility to functionalize the irradiated sample with subsequent chemical methods; finally a perfect nanopore with smooth edge appears when the ion fluence is high enough. We found that the dependence of ion damage efficiency on ion fluence, energy, and incident angle are different from that predicted by the semi-empirical model based on the binary-collision approximation, which results from the special structure of graphene. Our results demonstrate that it is feasible to fabricate controlled nanopores/nanostructures in graphene via heavy ion irradiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Value of Concentrating Solar Power and Thermal Energy Storage

Our paper examines the value of concentrating solar power (CSP) and thermal energy storage (TES) in a number of regions in the southwestern United States. Our analysis also shows that TES can increase the value of CSP by allowing more thermal energy from a CSP plant's solar field to be used, allowing a CSP plant to accommodate a larger solar field, and by allowing CSP generation to be shifted to hours with higher energy prices. We also analyze the sensitivity of this value to a number of factors, including the optimization period, price and solar forecasting, ancillary service sales, and dry cooling of the CSP plant, and also estimate the capacity value of a CSP plant with TES. We further discuss the value of CSP plants and TES net of capital costs.

14 SOLAR ENERGY↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Optimizing Direct Air Capture Solvents to Minimize Energy Consumption of CO 2 Release in a Carbonate Electrolyzer

Addressing climate change by carbon management is critical to achieving the goal of net zero carbon emissions by 2050. In this work, we examined the electrochemically-driven recovery of CO 2 during alkaline solvent regeneration for solvent-based direct air capture. A mathematical model was developed by incorporating carbonate chemistry with water electrolysis to predict the energy consumption per unit of CO 2 released. The predicted results were consistent with the experimental data, in which the experimental work was achieved by characterizing alkalinity and carbon loading values of solvent collected from a flow carbonate electrolyzer. Through this study, we learned that minimizing the energy expended on CO 2 release can be achieved by using an anolyte with a lower alkalinity, increasing the electric charge input to the electrolyzer, and reducing the ohmic resistance of the electrolyzer. Furthermore, using a supporting electrolyte, e.g., Na 2 SO 4 in the present work, effectively compensates for the higher ohmic resistance from using an anolyte with a lower alkalinity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilizing Commercial Real Estate Owner and Investor Data to Analyze the Financial Performance of Energy Efficient, High-Performance Office Buildings

Evidence has shown that owning and operating energy-efficient, high-performance, “green” properties results in multiple benefits including lower utility bills, higher rents, improved occupancy, and greater net operating income. However, it is difficult to isolate and control moderating factors to identify the specific drivers behind improved financial performance and value to investors that results from sustainability in real estate. DOE is interested in facilitating deeper investigation of the correlation between energy efficiency and financial performance, reducing data acquisition and matching challenges, and developing a stronger understanding of how sustainable design and energy efficiency impact value. DOE commissioned this pilot study to test the logistical and empirical procedures required to establish a Commercial Real Estate Data Aggregation & Trends Analysis lab, determine the potential benefits available through the lab, and contribute to the existing body of evidence in this field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The path to 2060: Saudi Arabia's long-term pathway for GHG emission reduction

Saudi Arabia, as part of its Saudi Green Initiative, has announced its goal to achieve net zero green-house gas emissions by 2060. This ambitious target underscores the nation's dedication to address-ing climate change. However, there is a significant gap in comprehensive analysis regarding the long-term effects of Saudi Arabia's climate policies and their collective contribution towards the net-zero objective. This study endeavors to bridge this gap through a detailed examination using the GCAM-KSA, a specialized version of the Global Change Analysis Model tailored for Saudi Arabia, employing a multi-sectoral methodology that integrates economic, energy, and land use systems within a coherent framework to assess the impact of climate policies on GHG emissions. Our anal-ysis reveals that reaching net-zero GHG emissions by 2060 is a complex challenge requiring con-certed efforts across all sectors of the economy. While transitioning to low-carbon electricity and improving energy efficiency offer considerable emission reductions, fully decarbonizing the indus-trial and transportation sectors poses a significant hurdle. Our findings suggest that Saudi Arabia must triple its emission reduction commitments in its next Nationally Determined Contributions (NDCs) update to align with its 2060 net-zero goal. Early action and increased ambition could avoid the chances of getting locked into the high emission assets and give enough time to transform the energy system. Furthermore, the adoption and integration of Carbon Dioxide Removal (CDR) tech-nologies are identified as crucial for offsetting residual emissions, especially in sectors that might continue to rely on fossil fuels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

42 ENGINEERING↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗

Auroral electrons of energy less than 1 keV observed at rocket altitudes.

Measurements of electrons of energy less than 1 keV in the auroral precipitation with detectors aboard three rocket flights are discussed. Detectors simultaneously measured the flux of electrons moving up and down the magnetic field lines. Electrons of energy less than a few hundred electron volts show directional intensities ranging from isotropic over the upper hemisphere, to field aligned into the atmosphere, to a net streaming out of the atmosphere. Cases of reflection coefficients greater than 1 for the few hundred electron volts and lower-energy electrons occur when measurements were made north of auroral forms. These electrons might represent the high-energy tail of the return Birkeland currents. The origin of the low-energy electrons is itself in question.

Arnoldy, R. L.↗

Data-driven emulation of modal aerosol microphysics via neural operator-based modeling

The complexity and the small characteristic scales of aerosol microphysical processes pose a big challenge for accurate and efficient Earth system simulations at regional and global scales. In this work, we construct and evaluate a surrogate model: the aerosol deep operator network (ADON), a physics-inspired dual-net architecture for emulating the aerosol microphysics parameterization suite in the version 2 of the Energy Earth System Model (E3SMv2). The current version of the surrogate model is trained on a dataset comprising 9.8 million samples obtained from a global E3SMv2 simulation with the horizontal resolution of about one degree under cloud-free conditions. Incorporating domain spatial and temporal coordinates, as well as principle components extracted from training data, the dual-net surrogate model effectively captures the intricate representations of aerosol and the relationship with atmospheric state variables, achieving an R-squared score over $$95.7\%$$ for all the lognormal aerosol modes in the extrapolated regime. The validated model provides feature importance of input variables and their impact on the predictive capacity of the surrogate model in relation to the E3SM. The computational cost of online inference time deployed on CPUs and GPUs with lower precisions highlights ADON’s efficiency and potential in robust predictive modeling for large-scale Earth system computations.

Bai, Zhe↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗