Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ML”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Advanced data mining in field ion microscopy

Field ion microscopy (FIM) allows to image individual surface atoms by exploiting the effect of an intense electric field. Widespread use of atomic resolution imaging by FIM has been hampered by a lack of efficient image processing/data extraction tools. Recent advances in imaging and data mining techniques have renewed the interest in using FIM in conjunction with automated detection of atoms and lattice defects for materials characterization. After a brief overview of existing routines, we review the use of machine learning (ML) approaches for data extraction with the aim to catalyze new data-driven insights into high electrical field physics. Apart from exploring various supervised and unsupervised ML algorithms in this context, we also employ advanced image processing routines for data extraction from large sets of FIM images. The outcomes and limitations of such routines are discussed, and we conclude with the possible application of energy minimization schemes to the extracted point clouds as a way of improving the spatial resolution of FIM.

36 MATERIALS SCIENCE↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Graph neural networks for mechanical property prediction of 2D fiber composites

This work investigates the ability of graph neural networks (GNNs) to homogenize 2D fiber composite microstructures. We use different inhomogeneity and anisotropy indices to motivate and show that the Volume Elements (VEs) used in ML methods should ideally be far from their Representative Volume Element (RVE) size limit and, consequently, are notably anisotropic. Hence, training only the isotropic limit properties may not be acceptable. Another aspect is the need to normalize elastic stiffness values for ML, especially when high elastic contrast ratios are encountered between composite phases or in the material set. We introduce a normalization technique based on the mean-field method (MFM) to handle such high contrast ratios and train for the entire stiffness tensor. We show that the proposed GNN approaches exhibit high accuracy and efficiency compared to traditional methods and convolutional neural networks, utilizing unstructured graphs constructed from microstructure topology. Our model successfully predicts the stiffness tensor, peak strength under bulk damage, and brittle fracture initiation strength across diverse microstructure configurations while maintaining high accuracy even for extreme material contrasts and volume fractions. We also present a method to improve prediction accuracy for small dataset sizes using Voronoi partitioning.

Brittle strength↗

Hierarchical hollow microsphere and flower-like indium oxide: Controllable synthesis and application as H{sub 2}S cataluminescence sensing materials

Graphical abstract: Hierarchical hollow microsphere and flower-like In{sub 2}O{sub 3} were controllable fabricated through a novel and simple hydrothermal process, and the former showed superior cataluminescence sensing performance to H{sub 2}S. Highlights: ► In{sub 2}O{sub 3} hierarchical hollow sphere were prepared via a hydrothermal route. ► The growth process of In{sub 2}O{sub 3} hierarchical hollow sphere has been investigated. ► The sensor based on prepared In{sub 2}O{sub 3} shows good sensing performance to H{sub 2}S. -- Abstract: In the present work, In{sub 2}O{sub 3} hierarchical hollow microsphere and flower-like microstructure were achieved controllably by a hydrothermal process in the sodium dodecyl sulfate (SDS)-N,N-dimethyl-formamide (DMF) system. XRD, SEM, HRTEM and N{sub 2} adsorption measurements were used to characterize the as-prepared indium oxide materials and the possible mechanism for the microstructures formation was briefly discussed. The cataluminescence gas sensor based on the as-prepared In{sub 2}O{sub 3} was utilized to detect H{sub 2}S concentrations in flowing air. Comparative gas sensing results revealed that the sensor based on hierarchical hollow microsphere exhibited much higher sensing sensitivity in detecting H{sub 2}S gas than the sensor based on flower-like microstructure. The present gas sensor had a fast response time of 5 s and a recovery time of less than 25 s, furthermore, the cataluminescence intensity vs. H{sub 2}S concentration was linear in range of 2–20 μg mL{sup −1} with a detection limit of 0.5 μg mL{sup −1}. The present highly sensitive, fast-responding, and low-cost In{sub 2}O{sub 3}-based gas sensor for H{sub 2}S would have many practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water induced size and structure phase transition of CdS crystals and their photocatalytic property

Graphical abstract: Excellent photocatalytic activity in degradation of RhB was found with the hexagonal CdS nanorods growing along [0 0 0 1] direction, which is a result of the exposed (0 0 0 1) facets in the ends. Display Omitted Highlights: ► CdS microwires and nanorods were attained by a modified CHM approach. ► The phase transition (cubic to hexagonal) was achieved by tuning the amount of H{sub 2}O. ► Excellent photocatalytic activity was found with the hexagonal CdS. ► Hexagonal CdS has the better catalytic property due to more (0 0 0 1) facets exposed. -- Abstract: Single-crystalline CdS microwires (mixed cubic and hexagonal phase) and nanorods (pure hexagonal phase) were synthesized by a modified composite-hydroxide-mediated (CHM) approach. Photocatalytic degradation of rhodamine B with the CdS nanorods was studied under the simulated sunlight irradiation. Crystalline phase transition from cubic to hexagonal phase was achieved by adding a small amount of water in the melts. The phase structures and morphologies of the prepared products were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), selected area of electron diffraction (SAED) and scanning electron microscopy (SEM), respectively. The results show that the pure hexagonal phase structure could be obtained with 5 mL or more than 5 mL water added in the composite-hydroxide melts. The band–gap of the hexagonal nanorods was 2.435 eV observed from UV–vis reflection spectrum. Compared with the CdS nanoparticles (mixed cubic and hexagonal phase), we found that the hexagonal phase structure CdS nanorods revealed much better photocatalytic activity owing to the exposure of (0 0 0 1) polar facet on the end. It is expected that the present research may offer useful guidance to the potential application of CdS in the treatment of environmental pollution.

36 MATERIALS SCIENCE↗

CdSe@ZnS nanocomposites prepared by a mechanochemical route: No release of Cd{sup 2+} ions and negligible in vitro cytotoxicity

Graphical abstract: - Highlights: • CdSe@ZnS nanocomposites were produced by milling. • Negligible cadmium leakage was observed. • No toxicity against living cells was documented. • The material is suitable for biological imaging. - Abstract: CdSe@ZnS nanocomposites have been prepared by a two-step solid state mechanochemical synthesis. CdSe prepared from Cd and Se elements in the first step was mixed with zinc acetate and sodium sulphide in the second step of milling to prepare a CdSe@ZnS nanocomposite. In the third step, the obtained nanocomposite was coated with L-cysteine to prepare a biocompatible system. The crystallite size of the new type of nanocomposite was 20–35 nm for cubic CdSe and 3–8 nm for hexagonal ZnS as calculated from XRD, TEM and SEM data. The synthesised samples show good crystallinity and have been tested for dissolution and cytotoxicity. The dissolution of cadmium from CdSe@ZnS was less than 0.05 μg mL{sup −1}, whereas a value of 0.8 μg mL{sup −1} was measured for CdSe alone. The binding of ZnS with CdSe in the nanocomposite practically eliminated the release of cadmium into solution. As a consequence, a very low cytotoxic activity has been evidenced for CdSe@ZnS. The nanocomposites coated with L-cysteine have a great potential as fluorescent labels in biomedical engineering.

36 MATERIALS SCIENCE↗

Facile synthesis of the nitrogen-doped graphene quantum dots at low temperature for cellular labeling

Highlights: • The N-GQDs are prepared via a facile stirring method on a magnetic stirrer at low temperature. • The N-GQDs exhibit outstanding biocompatibility in the live HeLa cells for biological applications. • The live cells keep a 100% survival rate in the high N-GQDs concentration of 200 μg mL{sup −1} for 48 h. - Abstract: A facile one-step approach is developed for the large-scale synthesis of nitrogen doped graphene quantum dot (N-GQDs) at low temperature by using citric acid (CA) as the precursor. The emission wavelength of the N-GQDs is nearly excitation-dependent, which may mirror the effects from particles of different sizes and distribution of different emissive sites on nanoparticles. Moreover, the products are then tested with live Hela cells for the extraordinary biocompatibility. The cellular viability is remained to be 100% even after a 48 h exposure with the high N-GQDs concentration of 200 μg mL{sup −1} and this survival rate is really much higher than that have been reported previously. The as-prepared N-GQDs with negligible inherent toxicity exhibit excellent biological applications such as bio-imaging and cell tracking.

60 APPLIED LIFE SCIENCES↗

Fabrication, mechanism, formic acid−tuned degradation and photocatalytic hydrogen production of novel modified ZnO spheres by L−TA−DMF assisted hydrothermal method

Highlights: • Many novel ZnO microspheres and building blocks were obtained. • It is first time that DMF and TA were used to fabricate ZnO simultaneously. • Five visible emissions are generated simultaneously and their PL intensities are tunable. • Formic acid induced photocatalytic efficiency was obtained. The H{sub 2} generation rate of S6 is 4.15 mL h{sup −1} g{sup −1} under simulated sunlight irradiation. • Photocatalytic mechanism and self-assembly modes were proposed. - Abstract: Many ZnO microspheres were fabricated by hydrothermal method using l−TA and DMF as double capping agents. These spheres possess many novel nanostructures and exhibit unique and flexible self−assemblies and building units. For example, diverse pattern−like spheres, core/shell spheres, and semispheres were obtained. FTIR spectra of S1−S9 show TA and HCOOH modified ZnO spheres, which agree with those of XPS analysis. PL spectra show that violet, blue, green, yellow and orange emissions generated simultaneously can be tuned. E{sub g} and ε are influenced by c. TA and DMF lead to diverse and novel ZnO growth, while DMF can tune the number of surface active sites of exposed (002) facet of ZnO, which determines final photocatalytic efficiency. TOC results show most of MB are mineralized rather than being partially degraded. The photocatalytic H{sub 2} generation rate is 4.15 ml h{sup −1}g{sup −1} under simulated sunlight irradiation. In addition, DMF−induced photocatalytic mechanisms and two self−assemblies were proposed.

36 MATERIALS SCIENCE↗

Clinical Assessment Of Stereotactic IGRT: Spinal Radiosurgery

The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited because of the availability of effective target immobilization devices. Recent advances in stereotactic IGRT have allowed for spinal applications. Large clinical experience with spinal radiosurgery to properly assess clinical outcomes has previously been limited. At our institution, we have developed a successful multidisciplinary spinal radiosurgery program in which 542 spinal lesions (486 malignant and 56 benign lesions) were treated with a single-fraction radiosurgery technique. Patient ages ranged from 18 to 85 years (mean 56 years). Lesion location included 92 cervical, 234 thoracic, 130 lumbar, and 86 sacral. The most common metastatic tumors were renal cell (89 cases), breast (74 cases), and lung (71 cases). The most common benign tumors were neurofibroma (24 cases), schwannoma (13 cases), and meningioma (7 cases). Eighty-nine cervical lesions were treated using skull tracking. Thoracic, lumbar, and sacral tumors were tracked relative to either gold or stainless steel fiducial markers. The maximum intratumoral dose ranged from 12.5 to 30 Gy (mean 20 Gy). Tumor volume ranged from 0.16 to 298 mL (mean 47 mL). Three hundred thirty-seven lesions had received prior external beam irradiation with spinal cord doses precluding further conventional irradiation. The primary indication for radiosurgery was pain in 326 cases, as a primary treatment modality in 70 cases, for tumor radiographic tumor progression in 65 cases, for post-surgical treatment in 38 cases, for progressive neurological deficit in 35 cases, and as a radiation boost in 8 cases. Follow-up period was at least 3 to 49 months. Axial and/or radicular pain improved in 300 of 326 cases (92%). Long-term tumor control was demonstrated in 90% of lesions treated with radiosurgery as a primary treatment modality and in 88% of lesions treated for radiographic tumor progression. Thirty of 35 patients (85%) with progressive neurological deficits experienced at least some improvement after treatment. Spinal stereotactic radiosurgery is now a feasible, safe, and clinically effective technique for the treatment of a variety of spinal lesions. The potential benefits of radiosurgical ablation of spinal lesions are short treatment time in an outpatient setting with essentially no recovery time and excellent symptomatic response. This technique offers a new therapeutic modality for the primary treatment of a variety of spinal lesions, including the treatment of neoplasms in medically inoperable patients, previously irradiated sites, for lesions not amenable to open surgical techniques, and as an adjunct to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic and Dosimetric Changes During the Treatment Course of Intensity-Modulated Radiotherapy for Locally Advanced Nasopharyngeal Carcinoma

Many patients with nasopharyngeal carcinoma (NPC) have marked anatomic change during intensity-modulated radiation therapy (IMRT). In this study, the magnitude of anatomic changes and its dosimetric effects were quantified. Fifteen patients with locally advanced NPC treated with IMRT had repeated computed tomography (CT) after 18 fractions. A hybrid plan was made to the anatomy of the second computed tomography scan. The dose of the original plan, hybrid plan, and new plan were compared. The mean volume of left and right parotid decreased 6.19 mL and 6.44 mL, respectively. The transverse diameters of the upper bound of odontoid process, the center of odontoid process, and the center of C2 vertebral body slices contracted with the mean contraction of 8.2 mm, 9.4 mm, and 7.6 mm. Comparing the hybrid plan with the treatment plan, the coverage of target was maintained while the maximum dose to the brain stem and spinal cord increased by 0.08 to 6.51 Gy and 0.05 to 7.8 Gy. The mean dose to left and right parotid increased by 2.97 Gy and 2.57 Gy, respectively. A new plan reduced the dose of spinal cord, brain stem, and parotids. Measurable anatomic changes occurring during the IMRT for locally advanced NPC maintained the coverage of targets but increased the dose to critical organs. Those patients might benefit from replanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Analysis of 3D Image-Guided HDR Brachytherapy Planning for the Treatment of Cervical Cancer: Is Point A-Based Dose Prescription Still Valid in Image-Guided Brachytherapy?

The purpose of this study was to analyze the dosimetric outcome of 3D image-guided high-dose-rate (HDR) brachytherapy planning for cervical cancer treatment and compare dose coverage of high-risk clinical target volume (HRCTV) to traditional Point A dose. Thirty-two patients with stage IA2-IIIB cervical cancer were treated using computed tomography/magnetic resonance imaging-based image-guided HDR brachytherapy (IGBT). Brachytherapy dose prescription was 5.0-6.0 Gy per fraction for a total 5 fractions. The HRCTV and organs at risk (OARs) were delineated following the GYN GEC/ESTRO guidelines. Total doses for HRCTV, OARs, Point A, and Point T from external beam radiotherapy and brachytherapy were summated and normalized to a biologically equivalent dose of 2 Gy per fraction (EQD2). The total planned D90 for HRCTV was 80-85 Gy, whereas the dose to 2 mL of bladder, rectum, and sigmoid was limited to 85 Gy, 75 Gy, and 75 Gy, respectively. The mean D90 and its standard deviation for HRCTV was 83.2 {+-} 4.3 Gy. This is significantly higher (p < 0.0001) than the mean value of the dose to Point A (78.6 {+-} 4.4 Gy). The dose levels of the OARs were within acceptable limits for most patients. The mean dose to 2 mL of bladder was 78.0 {+-} 6.2 Gy, whereas the mean dose to rectum and sigmoid were 57.2 {+-} 4.4 Gy and 66.9 {+-} 6.1 Gy, respectively. Image-based 3D brachytherapy provides adequate dose coverage to HRCTV, with acceptable dose to OARs in most patients. Dose to Point A was found to be significantly lower than the D90 for HRCTV calculated using the image-based technique. Paradigm shift from 2D point dose dosimetry to IGBT in HDR cervical cancer treatment needs advanced concept of evaluation in dosimetry with clinical outcome data about whether this approach improves local control and/or decreases toxicities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Changes of the transverse diameter and volume and dosimetry before the 25th fraction during the course of intensity-modulated radiation therapy (IMRT) for patients with nasopharyngeal carcinoma

To quantify changes of the transverse diameter and volume and dosimetry, and to illustrate the inferiority of non-replanning during intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) patients. Fifty-three NPC patients who received IMRT in 33 fractions were enrolled in this prospective trial. Before the 25th fraction, a new simulation computed tomography (CT) scan was acquired for all patients. The dose-volume histograms of the phantom plan were compared with the initial plan. Significant reduction of the transverse diameter of the nasopharyngeal, the neck, and 2 parotid glands volume was observed on second CT compared with the first CT (mean reduction 7.48 {+-} 4.45 mm, 6.80 {+-} 15.14 mm, 5.70 {+-} 6.26 mL, and 5.04 {+-} 5.85 mL, respectively; p < 0.01). The maximum dose and V-40 of the spinal cord, mean dose, and V30 of the left and right parotid, and V-50 of the brain stem were increased significantly in the phantom plan compared with the initial plan (mean increase 4.75 {+-} 5.55 Gy, 7.18 {+-} 10.07%, 4.51 {+-} 8.55 Gy, 6.59 {+-} 17.82%, 5.33 {+-} 8.55 Gy, 11.68 {+-} 17.11% and 1.48 {+-} 3.67%, respectively; p < 0.01). On the basis of dose constraint criterion in the RTOG0225 protocol, the dose of the normal critical structures for 52.83% (28/53) of the phantom plans were out of limit compared with 1.89% (1/53) of the initial plans (p < 0.0001). Because of the significant change in anatomy and dose before the 25th fraction during IMRT, replanning should be necessary during IMRT with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc therapy vs conventional fixed-field intensity-modulated radiotherapy in a whole-ventricular irradiation: A planning comparison study

This study evaluated the dosimetric difference between volumetric-modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (cIMRT) in whole-ventricular irradiation. Computed tomography simulation data for 13 patients were acquired to create plans for VMAT and cIMRT. In both plans, the same median dose (100% = 24 Gy) was prescribed to the planning target volume (PTV), which comprised a tumor bed and whole ventricles. During optimization, doses to the normal brain and body were reduced, provided that the dose constraints of the target coverage were satisfied. The dose-volume indices of the PTV, normal brain, and body as well as monitor units were compared between the 2 techniques by using paired t-tests. The results showed no significant difference in the homogeneity index (0.064 vs 0.065; p = 0.824) of the PTV and conformation number (0.78 vs 0.77; p = 0.065) between the 2 techniques. In the normal brain and body, the dose-volume indices showed no significant difference between the 2 techniques, except for an increase in the volume receiving a low dose in VMAT; the absolute volume of the normal brain and body receiving 1 Gy of radiation significantly increased in VMAT by 1.6% and 8.3%, respectively, compared with that in cIMRT (1044 vs 1028 mL for the normal brain and 3079.2 vs 2823.3 mL for the body; p<0.001). The number of monitor units to deliver a 2.0-Gy fraction was significantly reduced in VMAT compared with that in cIMRT (354 vs 873, respectively; p<0.001). In conclusion, VMAT delivers IMRT to complex target volumes such as whole ventricles with fewer monitor units, while maintaining target coverage and conformal isodose distribution comparable to cIMRT; however, in addition to those characteristics, the fact that the volume of the normal brain and body receiving a low dose would increase in VMAT should be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Machine learning-based discovery of molecular descriptors that control polymer gas permeation

While machine learning has found increasing use in predicting the properties of polymeric materials with only a knowledge of chain architecture, determining the molecular factors underpinning properties (“interpretable AI”) has remained less well explored. We show that encoding chain chemistry in commonly employed formats, e.g., binary-valued fingerprints, leads to uniqueness issues during the hashing process to save storage space. This is because the hashing algorithm can map several chemical moieties into the same bit. These issues carry over into the ML algorithms, especially for “inverse” design and interpretable AI, and cannot be avoided by changing the length of the fingerprint. Using MACCS key featurizations of monomer repeats resolves some of these issues, and we show that a few substructures consistently appear in top features for maximizing permeability across several gases and ML models. These are carbon–carbon double bonds (as in polyacetylenes) especially when they are associated with methyl groups (found in branching architectures). Here these results, derived from the limited data set of ~ 500 polymers with experimental gas permeation data, are in agreement with physical insight and thus provide a robust foundation which could further enable study of these material classes through detailed experiments and simulations.

36 MATERIALS SCIENCE↗

Hydrogen permeability and stability of palladium films in a high pressure reactor

Palladium (Pd) thin films were fabricated by colloidal spray deposition (CSD) on substrates of porous yttrium stabilized zirconium oxide (YSZ). The films were sintered at 1140–1160 °C for 2–3 h in argon and had thickness of 5–11 μm. The hydrogen (H 2 ) permeation flux for the Pd film was measured with simulated feed gases (90% H 2 /He, syn-gas/steam, or syn-gas/steam with H 2 S) flowing on the film side and sweep gas (Ar) flowing on the substrate side. Here, the hydrogen flux with the Pd film was obtained by adjusting the flow rate and pressure of the gas. Hydrogen flux values of 121–173 cm 3 min -1 cm -2 were measured at 388–596 °C (feed: 90% H 2 /He at 200 mL min -1 ; sweep: Ar at 1400 mL min -1 ; and ΔP = ~170 psi), and the permeability was calculated and compared with literature values. Because Pd is known to be sensitive to some gases, the stability of Pd films was evaluated by examining the microstructures of samples after their exposure to gas mixtures containing CO, CO 2 , H 2 O, and H 2 S. From the results of stability tests in H 2 S-containing atmospheres, the Pd/Pd 4 S phase boundary was determined, and this measured boundary was compared to the Pd/Pd 4 S boundary calculated from the thermodynamic data in the literature.

36 MATERIALS SCIENCE↗

A combined experimental and machine learning exploration of Ti 2-x Zr x MnCrFeNi high entropy Laves hydrides

A series of high entropy AB 2 -type Ti 2-x Zr x MnCrFeNi alloys (x = 0.6, 0.7, 0.8, 0.9, 1.0, 1.1 and 1.2) were synthesized to investigate their potential for hydrogen storage and chemical compression. The influence of the Ti/Zr ratio was explored in terms of structural, microstructural and thermodynamic properties. The storage capacity together with the reaction enthalpy and entropy changes of the synthesized high entropy alloys were compared to predictions from Machine Learning (ML) to investigate changes in these properties across the explored composition space. The results revealed that a decreasing Zr content consistently lowered the hydride formation enthalpy and increased the plateau pressure from 8 to >90 bar H 2 at 25 °C, in good agreement with ML predictions. Selected compositions (x = 1.0 and 1.2) demonstrated reversible hydrogen storage capability over 150 cycles, with capacities of 1.34–1.40 wt % H 2 and remarkable reaction kinetics (<4 min) at ambient temperature. These experimental and computational findings highlight the potential of this Laves-HEA system as tuneable, stable, and cost-effective materials suitable for long-term operations in stationary hydrogen storage and compression applications.

36 MATERIALS SCIENCE↗

Dense autoencoders, clustering techniques, and semi-supervised learning for HPGe $γ$-spectra

Classifying high-resolution gamma spectra by their isotopic content is an essential task in nuclear forensics and other applications. Traditional analysis methods are often time-intensive, but machine learning (ML) may help analysts quickly process many spectra. Such methods tend to rely on abundant, well-labeled data for training. Historical gamma data exists in various fields but is not uniformly useful for supervised ML due to inconsistent labeling. Here, to address some of these challenges, we present a method to classify and organize unlabeled data from high-purity germanium detectors using an autoencoding neural network (autoencoder). We trained dense autoencoders to compress gamma data into latent representations that enable efficient data characterization. By clustering the encoded spectra or lower-dimensional mappings of them, we identified and removed portions of over-abundant data categories, resulting in a more balanced dataset and improved autoencoder performance. This encoding and clustering pipeline also enabled the organization of spectra into self-consistent categories. Finally, we found that encoded representations showed potential as inputs for semi-supervised learning of nuclide identification (NID) labels, achieving an average F1 score of 0.85 ± 0.03 when mapping encodings to a set of 65 isotope labels.

Autoencoders↗

Universal machine learning framework for defect predictions in zinc blende semiconductors

Our article introduces a universal predictive framework for point defect formation energies and charge transition levels in a wide chemical space of zinc blende semiconductors and possible impurity atoms selected from across the periodic table. This framework was developed by leveraging high-throughput quantum mechanical simulations benchmarked using some experimental data from the literature, as well as machine learning (ML)-based regressions techniques that map unique materials descriptors to computed defect properties and yield optimized and generalizable models. Furthermore, the power and utility of these models is revealed through quick predictions for thousands of new defects and screening of low-energy impurities, which may tune the equilibrium conductivity in the semiconductor. This work presents, to our knowledge, the largest density functional theory (DFT) dataset of defect properties in semiconductors and the largest DFT+ML-based screening of point defects in semiconductors to date.

36 MATERIALS SCIENCE↗