Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implementation Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-E-T-230: Measurement of Proton-Activated Positron Emission with PRESAGE 3-D Dosimeters

Purpose: Measurement of positron emission following proton beam irradiation of a target has been studied as a method of in-vivo dosimetry. Relative dosimetry studies between a phantom and treatment plan are susceptible to range uncertainties from material heterogeneities and setup error. By using the radiochromic polyurethane dosimeter PRESAGE, we can correlate the proton dose distribution to the PET activity measurement within a single detector. The PRESAGE formulation used was developed for high-LET proton radiotherapy, has similar density and RLSP to tissue, and consists of a greater carbon component, which gives it a higher positron signal than many other 3D detectors. Methods: Three cylindrical PRESAGE dosimeters were irradiated semi-uniformly to 500 cGy with 180- MeV protons. The beam was directed along the dosimeter axis and delivered a 2-cm SOBP at the center of the dosimeter. The dosimeters were rushed to a nearby PET/CT where imaging began within 15 minutes, less than a single half-life of 11C. A 3-hr measurement captured the full activation decay. Afterwards, the dose profiles were measured by optical-CT. A direct comparison between the measured dose and the positron emission was performed using CERR software. Results: The correlations between dose distributions and PET activity were consistent with previous studies in that the proximal region of the SOBP displayed the highest activity. The spatial distributions between the dose and activity were similar. Along the central axis of the beam, we found a shift in the distal 80% of 1 cm. The lateral profile showed good agreement between dose and activity. PET imaging times between 30-min and 3-hrs showed <5% discrepancy. Conclusion: PRESAGE dosimeters offer a strong and unique potential to accurately correlate dosimetric and PET activation information. Implementation in an anthropomorphic phantom could be used to study representative treatment plans. NIH grant 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

Market redesign and technology upgrade: a nodal implementation

The California ISO and its market participants collectively cut over to a new nodal-based market on April 1, largely without incident and 11 years to the day from the initial startup in 1998. Thus far, the new nodal framework has proven robust, and the inevitable design and implementation issues that have emerged since cutover have been manageable. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-J-94: Development of a Plug-in Based Image Analysis Tool for Integration Into Treatment Planning

Purpose: To extend the functionality of a commercial treatment planning system (TPS) to support (i) direct use of quantitative image-based metrics within treatment plan optimization and (ii) evaluation of dose-functional volume relationships to assist in functional image adaptive radiotherapy. Methods: A script was written that interfaces with a commercial TPS via an Application Programming Interface (API). The script executes a program that performs dose-functional volume analyses. Written in C#, the script reads the dose grid and correlates it with image data on a voxel-by-voxel basis through API extensions that can access registration transforms. A user interface was designed through WinForms to input parameters and display results. To test the performance of this program, image- and dose-based metrics computed from perfusion SPECT images aligned to the treatment planning CT were generated, validated, and compared. Results: The integration of image analysis information was successfully implemented as a plug-in to a commercial TPS. Perfusion SPECT images were used to validate the calculation and display of image-based metrics as well as dose-intensity metrics and histograms for defined structures on the treatment planning CT. Various biological dose correction models, custom image-based metrics, dose-intensity computations, and dose-intensity histograms were applied to analyze the image-dose profile. Conclusion: It is possible to add image analysis features to commercial TPSs through custom scripting applications. A tool was developed to enable the evaluation of image-intensity-based metrics in the context of functional targeting and avoidance. In addition to providing dose-intensity metrics and histograms that can be easily extracted from a plan database and correlated with outcomes, the system can also be extended to a plug-in optimization system, which can directly use the computed metrics for optimization of post-treatment tumor or normal tissue response models. Supported by NIH - P01 - CA059827.

60 APPLIED LIFE SCIENCES↗

Toward Urban Water Security: Broadening the Use of Machine Learning Methods for Mitigating Urban Water Hazards

Due to the complex interactions of human activity and the hydrological cycle, achieving urban water security requires comprehensive planning processes that address urban water hazards using a holistic approach. However, the effective implementation of such an approach requires the collection and curation of large amounts of disparate data, and reliable methods for modeling processes that may be co-evolutionary yet traditionally represented in non-integrable ways. In recent decades, many hydrological studies have utilized advanced machine learning and information technologies to approximate and predict physical processes, yet none have synthesized these methods into a comprehensive urban water security plan. In this paper, we review ways in which advanced machine learning techniques have been applied to specific aspects of the hydrological cycle and discuss their potential applications for addressing challenges in mitigating multiple water hazards over urban areas. We also describe a vision that integrates these machine learning applications into a comprehensive watershed-to-community planning workflow for smart-cities management of urban water resources.

54 ENVIRONMENTAL SCIENCES↗

Sci—Sat AM: Stereo — 03: Dosmetric evaluation of single versus multi-arc VMAT for lung SBRT

Five non-small cell lung cancer patients previously treated with stereotactic body radiation therapy using the VMAT (volumetric modulated arc therapy) technique were selected for this retrospective study. Plans were re-optimized using Pinnacle treatment planning system (v9.0, Philips Medical), with the basis for comparison a two-arc plan involving a 360° arc in addition to a 90° arc with a couch kick. Additionally a single 360° arc was optimized for comparison, as well as a partial arc covering ∼230°, avoiding the contralateral lung. All plans met target coverage criteria as dictated by RTOG0236. Plans were evaluated based on conformity, sparing of organs at risk and practical considerations of delivery. Conformity was best in the two-arc plan; however the decrease seen in one- and partial arc plans was not statistically significant as tested by the Wilcoxon rank sum test. The partial-arc plan resulted in the lowest esophagus and trachea dose and the highest heart dose, however none of the plans exceeded organ at risk tolerances for lung SBRT. Partial arcs resulted in plans with slightly cooler dose distributions, a decrease in low dose spillage and an overall lower mean lung dose. The decrease in treatment time was on average 36 and 40 seconds for single and partial arcs, respectively, with partial arcs requiring the lowest number of MUs. The slight decrease in conformity seen in one-arc plans is offset by an increase in efficiency (optimization and treatment time, MUs) making the implementation of a single or partial-arc treatment technique clinically desirable.

60 APPLIED LIFE SCIENCES↗

Safety Requirement Management System (SRMS) - Improved Documented Safety Analyses Implementation - 18476

Savannah River Remediation (SRR) developed a new software application, Safety Requirement Management System (SRMS), to improve Documented Safety Analysis (DSA) safety requirement implementation in the Savannah River Site's Liquid Waste facilities. Technical Safety Requirement (TSR) Limited Conditions of Operations (LCOs) and related surveillances were previously tracked using four different applications. Due to their differences and their age, the applications introduced a number of operational challenges and vulnerabilities, including outdated platforms, usage demands beyond original design, and different organizational work processes. SRMS was developed to resolve these issues by using a single web-based approach that provides consistency, wider accessibility, simpler maintenance, and a platform for additional functionality. Other SRS facilities are evaluating the application for its applicability as a standard practice across the site. The new SRMS application decreased the administrative overhead for application maintenance, provided the needed TSR change management functionality, and reduced error precursors with the following advantages: - Consistent process/application across all SRR facilities - More efficient way to track and communicate compliance with DSA time-related requirements (i.e., TSR LCOs and surveillances). - Web-based search capability for LCO entries/exits and a record of surveillance performances. - TSR change management and independent reviews through electronic approvals. For example, the application provides the ability to bundle and stage LCO and surveillance changes associated with a TSR revision. The approval process involves multiple roles from the facility to ensure validity. - Formal configuration management program, fully supported by software life cycle documents. SRMS was implemented at Defense Waste Processing Facility (DWPF) in June 2017, with implementation in all Liquid Waste facilities expected by the end of 2017. Next, SRR plans to expand SRMS functionality to include a linking document database (LDD) to support the DSA requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 Field Surveillance Plan Update for 2017

The Packaging Surveillance Program section of the Department of Energy (DOE) Manual 441.1-­1, Nuclear Material Packaging Manual (DOE 2008), requires DOE contractors to “ensure that a surveillance program is established and implemented to ensure the nuclear material storage package continues to meet its design criteria.”This 2017 update reflects changes to the surveillance plan resulting from surveillance findings as documented in Reeves et al. 2016. These findings include observations of corrosion in SAVY and Hagan containers and the indication (in one SAVY container) of possible filter membrane thermal degradation. This surveillance plan update documents the rationale for selecting surveillance containers, specifies the containers for 2017 surveillance, and identifies a minimum set of containers for 2018 surveillance. This update contains important changes to the previous surveillance plans.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evolution of Programmatic Asset Lifecycle Planning at MESA

Early on in 2018 Sandia recognized the Microsystems Engineering, Science and Applications (MESA) Programmatic Asset Lifecycle Planning capability to be unpredictable, inconsistent, reactive, and unable to provide strong linkage to the sponsor's needs. The impetus for this report is to share learnings from MESA's journey towards maturing this capability. This report describes re-building the foundational elements of MESA's Programmatic Asset Lifecycle Planning capability using a risk-based, Multi-Criteria Decision Analysis (MCDA) approach. To begin, MESA's decades-old Piano Chart + Ad Hoc Hybrid Methodology is described with a narrative of its strengths and weaknesses. Then its replacement, the MCDA /Analytical Hierarchy Process, is introduced with a discussion of its strengths and weaknesses. To generate a realistic Programmatic Asset Lifecycle Planning budget outlook, MESA used its rolling 20-year Extended Life Program Plan (MELPP) as a baseline. The new MCDA risk-based prioritization methodology implements DOE/NNSA guidelines for prioritization of DOE activities and provides a reliable, structured framework for combining expert judgement and stakeholder preferences according to an established scientific technique. An in-house Hybrid Decision Support System (HDSS) software application was developed to facilitate production of several key deliverables. The application enables analysis of the prioritization decisions with charts to display and provide linkage of MESA's funding requests to the stakeholders' priorities, strategic objectives, nuclear deterrence programs, MESA priorities, and much more.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

HWMA/RCRA CLOSURE PLAN FOR THE MATERIALS TEST REACTOR WING (TRA-604) LABORATORY COMPONENTS VOLUNTARY CONSENT ORDER ACTION PLAN VCO-5.8 D REVISION2

This Hazardous Waste Management Act/Resource Conservation and Recovery Act closure plan was developed for the laboratory components of the Test Reactor Area Catch Tank System (TRA-630) that are located in the Materials Test Reactor Wing (TRA-604) at the Reactor Technology Complex, Idaho National Laboratory Site, to meet a further milestone established under Voluntary Consent Order Action Plan VCO-5.8.d. The TRA-604 laboratory components addressed in this closure plan were deferred from the TRA-630 Catch Tank System closure plan due to ongoing laboratory operations in the areas requiring closure actions. The TRA-604 laboratory components include the TRA-604 laboratory warm wastewater drain piping, undersink drains, subheaders, and the east TRA-604 laboratory drain header. Potentially contaminated surfaces located beneath the TRA-604 laboratory warm wastewater drain piping and beneath the island sinks located in Laboratories 126 and 128 (located in TRA-661) are also addressed in this closure plan. The TRA-604 laboratory components will be closed in accordance with the interim status requirements of the Hazardous Waste Management Act/Resource Conservation and Recovery Act as implemented by the Idaho Administrative Procedures Act 58.01.05.009 and 40 Code of Federal Regulations 265, Subparts G and J. This closure plan presents the closure performance standards and the methods for achieving those standards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-208: Fast and Accurate Auto-Segmentation of Abdominal Organs at Risk for Online Adaptive Radiotherapy

Purpose: Various studies have demonstrated that online adaptive radiotherapy by real-time re-optimization of the treatment plan can improve organs-at-risk (OARs) sparing in the abdominal region. Its clinical implementation, however, requires fast and accurate auto-segmentation of OARs in CT scans acquired just before each treatment fraction. Autosegmentation is particularly challenging in the abdominal region due to the frequently observed large deformations. We present a clinical validation of a new auto-segmentation method that uses fully automated non-rigid registration for propagating abdominal OAR contours from planning to daily treatment CT scans. Methods: OARs were manually contoured by an expert panel to obtain ground truth contours for repeat CT scans (3 per patient) of 10 patients. For the non-rigid alignment, we used a new non-rigid registration method that estimates the deformation field by optimizing local normalized correlation coefficient with smoothness regularization. This field was used to propagate planning contours to repeat CTs. To quantify the performance of the auto-segmentation, we compared the propagated and ground truth contours using two widely used metrics- Dice coefficient (Dc) and Hausdorff distance (Hd). The proposed method was benchmarked against translation and rigid alignment based auto-segmentation. Results: For all organs, the auto-segmentation performed better than the baseline (translation) with an average processing time of 15 s per fraction CT. The overall improvements ranged from 2% (heart) to 32% (pancreas) in Dc, and 27% (heart) to 62% (spinal cord) in Hd. For liver, kidneys, gall bladder, stomach, spinal cord and heart, Dc above 0.85 was achieved. Duodenum and pancreas were the most challenging organs with both showing relatively larger spreads and medians of 0.79 and 2.1 mm for Dc and Hd, respectively. Conclusion: Based on the achieved accuracy and computational time we conclude that the investigated auto-segmentation method overcomes an important hurdle to the clinical implementation of online adaptive radiotherapy. Partial funding for this work was provided by Accuray Incorporated as part of a research collaboration with Erasmus MC Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Implications of Model Structure and Detail for Utility Planning: Scenario Case Studies Using the Resource Planning Model

In this report, we analyze the impacts of model configuration and detail in capacity expansion models, computational tools used by utility planners looking to find the least cost option for planning the system and by researchers or policy makers attempting to understand the effects of various policy implementations. The present analysis focuses on the importance of model configurations — particularly those related to capacity credit, dispatch modeling, and transmission modeling — to the construction of scenario futures. Our analysis is primarily directed toward advanced tools used for utility planning and is focused on those impacts that are most relevant to decisions with respect to future renewable capacity deployment. To serve this purpose, we develop and employ the NREL Resource Planning Model to conduct a case study analysis that explores 12 separate capacity expansion scenarios of the Western Interconnection through 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Retrieval of High Level Waste for the Cigeo Project - A Practical Retrieval Test Story - 16085

Since the passing of the June 28, 2006 Act, Andra has incorporated in its step-wise design development of the French high level waste (HLW) and intermediate level long lived waste (IL-LLW) deep geological repository (DGR, aka Cigeo) various requirements linked to 'reversibility' at different stages of the repository life cycle (from its construction phase to its final closure). Reversibility is based on a number of practical dispositions including the progressivity of the development and deployment of the facility, the flexibility of the nature of operations being carried out, the adaptability of the facility to future modifications and the possible retrieval of waste. The capacity to retrieve waste from Cigeo, also called 'retrievability', bears specific requirements. On a shorter term, one must demonstrate that the waste container retrieval operations are technically safe and feasible over at least 100 years. The current paper starts with two acceptations: retrievability and reversibility. It details how those two notions are defined and inter-linked. The 'Retrievability Scale' as proposed by OECD/NEA (and adopted by Andra) is also reminded. The needs for demonstration of retrieval operations are also exposed for the two categories of waste containers disposed of in Cigeo (IL-LLW and HLW) within the context of their respective emplacement configurations (in disposal horizontal vaults and micro-tunnels) at different stages of the repository life cycle. The technical part of the paper is then focused on a practical case story: a technological test campaign (still running) of HLW container retrieval out of a steel cased disposal micro-tunnel. On a test bench built on surface to simulate (create) the environmental conditions that may prevail inside a HLW micro-tunnel at time of retrieval, it was possible to check whether the mechanical means developed for the purpose were adequate and sufficient. The test case story is exposed, c/w the problems and challenges encountered (high temperature impairing the retrieval robot's proper functioning, presence of corrosion products...). The trouble-shooting solutions implemented and the results are commented. This article concludes with a critical analysis of the methods and equipment used, the results obtained and provides some perspectives of improvement. The positive outcomes of this technical test campaign pave the way for planning the in situ retrieval tests to be programmed in the 'industrial pilot phase' of Cigeo (to be implemented over the ten first years of operations, including the active and inactive test period and the first years of disposal activities): the industrial pilot phase is presently scheduled around 2026-2036 (provided the Cigeo construction is authorized in 2021, following the licensing request filing scheduled in 2018). The issues of IL-LLW containers retrieval (for which specific solutions are also studied and technical demonstrations engaged or planned) are also briefly presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac

Purpose: A linac delivering intensity-modulated radiotherapy (IMRT) can benefit from a flattening filter free (FFF) design which offers higher dose rates and reduced accelerator head scatter than for conventional (flattened) delivery. This reduction in scatter simplifies beam modeling, and combining a Monte Carlo dose engine with a FFF accelerator could potentially increase dose calculation accuracy. The objective of this work was to model a FFF machine using an adapted version of a previously published virtual source model (VSM) for Monte Carlo calculations and to verify its accuracy. Methods: An Elekta Synergy linear accelerator operating at 6 MV has been modified to enable irradiation both with and without the flattening filter (FF). The VSM has been incorporated into a commercially available treatment planning system (Monaco Trade-Mark-Sign v 3.1) as VSM 1.6. Dosimetric data were measured to commission the treatment planning system (TPS) and the VSM adapted to account for the lack of angular differential absorption and general beam hardening. The model was then tested using standard water phantom measurements and also by creating IMRT plans for a range of clinical cases. Results: The results show that the VSM implementation handles the FFF beams very well, with an uncertainty between measurement and calculation of <1% which is comparable to conventional flattened beams. All IMRT beams passed standard quality assurance tests with >95% of all points passing gamma analysis ({gamma} < 1) using a 3%/3 mm tolerance. Conclusions: The virtual source model for flattened beams was successfully adapted to a flattening filter free beam production. Water phantom and patient specific QA measurements show excellent results, and comparisons of IMRT plans generated in conventional and FFF mode are underway to assess dosimetric uncertainties and possible improvements in dose calculation and delivery.

60 APPLIED LIFE SCIENCES↗

Dragonfly-Inspired Algorithms for Intercept Trajectory Planning

Dragonflies are known to be highly successful hunters (achieving 90-95% success rate in nature) that implement a guidance law like proportional navigation to intercept their prey. This project tested the hypothesis that dragonflies are able to implement proportional navigation using prey-image translation on their eyes. The model dragonfly presented here calculates changes in pitch and yaw to maintain the prey's image at a designated location (the fovea) on a two-dimensional screen (the model's eyes ). When the model also uses self-knowledge of its own maneuvers as an error signal to adjust the location of the fovea, its interception trajectory becomes equivalent to proportional navigation. I also show that this model can also be applied successfully (in a limited number of scenarios) against maneuvering prey. My results provide a proof-of-concept demonstration of the potential of using the dragonfly nervous system to design a robust interception algorithm for implementation on a man-made system.

59 BASIC BIOLOGICAL SCIENCES↗

Waste management best practices for decommissioning of nuclear power plants - 15274

Decommissioning of a nuclear power plant involves the safe disposition of a large quantity of radioactive, hazardous and conventional waste. A number of nuclear power plant decommissioning projects have been completed or are nearing completion in the US, Germany and Spain. These projects have used various waste disposal and interim storage options, and have developed successful methods for handling the large quantities of waste created by the decommissioning. Additionally, decommissioning projects in several Asian and European countries are in progress or are in the planning stages such that strategies for the handling of decommissioning waste are being developed and/or implemented to address the regulatory requirements and disposal options available in these countries. These experiences provide important lessons learned and successful strategies for the handling of waste from power plant decommissioning projects. As the handling and disposition of decommissioning waste have a substantial effect on power plant decommissioning cost, schedule and complexity, these lessons learned are valuable for planning future decommissioning projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INECP Country Engagement Plans and Transformational Events [Slides]

The International Nonproliferation Export Control Program (INECP) harnesses the expertise of the U.S. Department of Energy (DOE) national laboratories to assist partners internationally in implementing and adopting strategic trade control measures that can effectively counter WMD procurement efforts. This presentation includes discussion of work with LANL INECP technical leads to update the engagement plan for Turkey, which involved researching Turkey’s WMD related legal framework, relevant export control agencies, and WMD-relevant industries (e.g. advanced manufacturing and aerospace).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Commissioning of intensity modulated neutron radiotherapy (IMNRT)

Purpose: Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center/Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. Methods: IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. Results: While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate/five head and neck) agreed to within -0.8 {+-} 1.4% and 5.0 {+-} 6.0% within and outside the target, respectively. Nearly all (22/24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)/prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and/or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. Conclusions: IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

60 APPLIED LIFE SCIENCES↗

Loadable Hypervisor Modules

This paper discusses the implementation of a new hypervisor mechanism for loading dynamic shared objects (modules) at runtime. These loadable hypervisor modules (LHM) are modeled after the loadable kernel modules used in Linux. We detail the current LHM implementation based on the Xen hypervisor. Potential use cases for this LHM mechanism include dynamic hypervisor instrumentation for debug tracing or performance analysis. We discuss the initial LHM prototype and future plans.

99 GENERAL AND MISCELLANEOUS↗