Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Diffraction imaging of nanocrystalline structures in organic semiconductor molecular thin films

The properties of organic solids depend on their structure and morphology, yet direct imaging using conventional electron microscopy methods is hampered by the complex internal structure of these materials and their sensitivity to electron beams. In this work, we manage to observe the nanocrystalline structure of two organic molecular thin-film systems using transmission electron microscopy by employing a scanning nanodiffraction method that allows for full access to reciprocal space over the size of a spatially localized probe (~2 nm). The morphologies revealed by this technique vary from grains with pronounced segmentation of the structure—characterized by sharp grain boundaries and overlapping domains—to liquid-crystal structures with crystalline orientations varying smoothly over all possible rotations that contain disclinations representing singularities in the director field. Lastly, the results show how structure–property relationships can be visualized in organic systems using techniques previously only available for hard materials such as metals and ceramics.

36 MATERIALS SCIENCE↗

Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of {sup 99m}Technetium-Albumin Macroaggregates

Purpose: To evaluate the incidence of extrahepatic deposition of technetium-99m-labeled albumin macroaggregates ({sup 99m}Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ({sup 90}Y-RE), and to report on technical solutions that can be used to ensure safe delivery of {sup 90}Y-microspheres in patients with initial extrahepatic deposition. Materials and Methods: A retrospective analysis of 26 patients with primary and secondary liver malignancies, who were scheduled for treatment with {sup 90}Y-RE in our institution in 2009, was performed. The angiograms and single-photon emission computed tomography images of all patients were reviewed by an interventional radiologist and a nuclear medicine physician, respectively, to identify and localize extrahepatic deposition of {sup 99m}Tc-MAA when present. Subsequently, the technical solutions were used to successfully perform {sup 90}Y-RE in these patients were evaluated and described. Results: Extrahepatic deposition of {sup 99m}Tc-MAA was observed in 8 of 26 patients (31%). In 7 of 8 patients, a second pretreatment angiography was performed to detect the cause of extrahepatic deposition. The technical solutions to enable safe {sup 90}Y microspheres delivery included more distal placement of the microcatheter in the proper/right hepatic artery in 4 of 7 (57%) patients; (super)selective catheterization of multiple segmental branches in 2 of 7 (29%); and additional coiling of a newly detected branch in the remaining patient (14%). This was confirmed by a second MAA procedure. {sup 90}Y-RE was eventually performed in 25 of 26 (96%) patients. No procedure-related complications (<30 days) were observed. Conclusion: Extrahepatic deposition of {sup 99m}Tc-MAA after pretreatment angiography did occur in 8 of 26 (31%) patients. The technical solutions as presented allowed safe {sup 90}Y-RE delivery in 25 of 26 (96%) patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor grades further improved when the textural features of the effective scatterer diameter parametric map were combined with the mean value of the map (p = 0.004). Conclusions: Overall, the binary classification results (tumor versus normal tissue) were more promising than tumor grade assessment. Combinations of advanced parameters can further improve the separation of tumors from normal tissue compared to the use of linear regression parameters. While the linear regression parameters were sufficient for characterizing breast tumors and normal breast tissues, advanced parameters and their textural features were required to better characterize tumor subtypes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture Description of the HFTS-2 Slant Core, Delaware Basin, West Texas

Previous work in the Midland Basin Hydraulic Fracture Test Site project (HFTS1) has shown the value of core recovered from a stimulated volume in providing information on the geometry and extent of hydraulic fractures. This project (HFTS2) is in the Wolfcamp Formation of the Delaware Basin. A slant core through the stimulated volume was acquired above and below a stimulated well and the results of the fracture description are presented here. Here, nine, 3-inch-diameter whole cores from the slant well were examined for fractures prior to slabbing, together with a CT scan of the core. We used criteria developed during the HFTS1 project to identify hydraulic, natural, drilling-induced and core-handling fractures. Material collected from a few fracture faces was cleaned, sieved, and examined under a microscope to look for proppant. A total of 1261 fractures, including 500 hydraulic fractures, were described in 948 feet of core. Hydraulic fractures are not evenly distributed through the cores; they tend to occur in clusters. Many are remarkably planar, smooth, and featureless, while others have twist hackles, steps, plumose, and kinks. Natural, subvertical fractures, mostly less than 1 mm in width, sealed with blocky calcite, are oriented NE-SW (Set 1) and WNW-ESE (Set 2). Two Set 1 fractures have drusy cement on parted faces and were possibly open prior to drilling. A few subvertical sealed fractures with different orientations are also present. Bed-parallel natural fractures, most having fibrous cement (beef), and some showing top-to-north bed-parallel shear are present. Faults with normal/oblique movement were found in one part of the core. Drilling induced and core-handling breaks were identified in all cores, and were also noted to have reactivated some natural fractures. The results from this work will allow hydraulic fracture distribution relative to the stimulated well to be assessed. The number of fractures is generally greater than the number of perforations, but these can be compared for different stages and perforation clusters. Surface features provide information about the direction of hydraulic fracture propagation and about segmentation and bifurcation that might increase the number of fracture strands. Reactivation of natural fractures, including bedding-parallel fractures, occurs although the mechanism of parting is mostly unknown. The wider HFTS2 project will make use of this fracture description to improve hydraulic fracture modeling (geomechanics and engineering), to help explain pressure depletion and fiber optics observations (reservoir depletion and frac geometry), to help verify indirect fracture diagnostic techniques such as microseismic monitoring (geophysics), and to help calibrate horizontal well image logs.

58 GEOSCIENCES↗

Electrically-cooled HPGe detector for advanced x-ray spectroscopy and imaging

High Purity Germanium (HPGe) detectors are used for high-resolution x- and gamma-ray spectroscopy. For their operation, the necessary cryogenic cooling is performed with liquid nitrogen or with electromechanical coolers. Although mature and industrialized solutions, most of HPGe detectors integrating electrical coolers present a limited spectroscopic performance due to the generated mechanical vibration and electromagnetic interference. This paper describes a novel HPGe detector, specifically designed to address the challenges of ultimate x-ray spectroscopy and imaging applications. Due to the stringent demands associated with nano-scale imaging in synchrotron applications, a custom-designed cryostat was built around a Canberra CP5-Plus electrical cooler featuring extremely low vibration levels and high cooling power. The heat generated by the cryo-cooler itself, as well as the electronics, is evacuated via an original liquid cooling circuit. This architecture can also be used to address high ambient temperature, which does not allow conventional cryo-coolers to work properly. The multichannel detector head can consist of a segmented monolithic HPGe sensor, or several closely packed sensors. Each sensor channel is read out by state-of-the-art pulse-reset preamplifiers in order to achieve excellent energy resolution for count rates in excess of 1 Mcps. The sensitive electronics are located in EMI-proof housings to avoid any interference from other devices on a beam-line. The front-end of the detector is built using selected high-purity materials and alloys to avoid any fluorescence effects. We present a detailed description of the detector design and we report on its performance. A discussion is also given on the use of electrically cooled HPGe detectors for applications requiring ultimate energy resolution, such as synchrotron, medicine or nuclear industry. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy

Purpose: Prostate radiation therapy dose planning directly on magnetic resonance imaging (MRI) scans would reduce costs and uncertainties due to multimodality image registration. Adaptive planning using a combined MRI-linear accelerator approach will also require dose calculations to be performed using MRI data. The aim of this work was to develop an atlas-based method to map realistic electron densities to MRI scans for dose calculations and digitally reconstructed radiograph (DRR) generation. Methods and Materials: Whole-pelvis MRI and CT scan data were collected from 39 prostate patients. Scans from 2 patients showed significantly different anatomy from that of the remaining patient population, and these patients were excluded. A whole-pelvis MRI atlas was generated based on the manually delineated MRI scans. In addition, a conjugate electron-density atlas was generated from the coregistered computed tomography (CT)-MRI scans. Pseudo-CT scans for each patient were automatically generated by global and nonrigid registration of the MRI atlas to the patient MRI scan, followed by application of the same transformations to the electron-density atlas. Comparisons were made between organ segmentations by using the Dice similarity coefficient (DSC) and point dose calculations for 26 patients on planning CT and pseudo-CT scans. Results: The agreement between pseudo-CT and planning CT was quantified by differences in the point dose at isocenter and distance to agreement in corresponding voxels. Dose differences were found to be less than 2%. Chi-squared values indicated that the planning CT and pseudo-CT dose distributions were equivalent. No significant differences (p > 0.9) were found between CT and pseudo-CT Hounsfield units for organs of interest. Mean {+-} standard deviation DSC scores for the atlas-based segmentation of the pelvic bones were 0.79 {+-} 0.12, 0.70 {+-} 0.14 for the prostate, 0.64 {+-} 0.16 for the bladder, and 0.63 {+-} 0.16 for the rectum. Conclusions: The electron-density atlas method provides the ability to automatically define organs and map realistic electron densities to MRI scans for radiotherapy dose planning and DRR generation. This method provides the necessary tools for MRI-alone treatment planning and adaptive MRI-based prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved diagnosis of the number of stenosed coronary artery vessels by segmentation with scatter and photo-peak window data for attenuation correction in myocardial perfusion SPECT

Background: Attenuation correction using segmentation of scatter and photo-peak window data (SSPAC) enables an evaluation of the attenuation map in a patient-specific manner without additional radiation exposure. We compared the accuracy of SSPAC and non-corrected myocardial perfusion scintigraphy methods for diagnosing the number of stenosed coronary artery vessels. Methods and Results: We retrospectively reviewed the data from 183 consecutive patients who underwent {sup 99m}Tc-tetrofosmin stress/rest SPECT examination and a coronary angiography within 3 months. The MPS images were reconstructed with and without SSPAC attenuation correction. We examined the accuracy of the quantitative interpretation using summed differential score in the detection of coronary artery disease (CAD). The attenuation maps were successfully determined in 179 of 183 patients (98%). In terms of the vessel-based diagnostic ability, sensitivity, specificity, positive predictive and negative predictive values of the SSPAC and non-correction methods for diagnosing CAD in individual coronary territories were 77%*, 89%, 74%*, and 90%* vs 51%, 87%, 62%, and 82%, respectively (*P < .05). In 35 patients with multi-vessel CAD, those values were 78%*, 81%, 93%, and 55%* vs 49%, 81%, 89%, and 34%, respectively (*P < .05; AUC: 0.82 vs 0.62, P < .05). Conclusion: SSPAC-corrected SPECT myocardial perfusion images exhibit improved accuracy in the detection of the number of stenosed coronary artery vessels, even in patients with multi-vessel CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstructing cerebrovascular networks under local physiological constraints by integer programming

We introduce a probabilistic approach to vessel network extraction that enforces physiological constraints on the vessel structure. The method accounts for both image evidence and geometric relationships between vessels by solving an integer program, which is shown to yield the maximum a posteriori (MAP) estimate to the probabilistic model. Starting from an over-connected network, it is pruning vessel stumps and spurious connections by evaluating the local geometry and the global connectivity of the graph. We utilize a high-resolution micro computed tomography (µCT) dataset of a cerebrovascular corrosion cast to obtain a reference network and learn the prior distributions of our probabilistic model. As a result, we perform experiments on micro magnetic resonance angiography (µMRA) images of mouse brains and discuss properties of the networks obtained under different tracking and pruning approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Cardiac Function After Multimodal Breast Cancer Therapy Assessed With Functional Magnetic Resonance Imaging and Echocardiography Imaging

Purpose: Breast intensity modulated radiation therapy (IMRT) reduces high-dose heart volumes but increases low-dose volumes. We prospectively assessed heart changes after 3D conformal RT (3DCRT) and IMRT for left-sided breast cancer. Heart dose was analyzed individually, 3DCRT patients were moderately exposed, and IMRT was performed only in patients with unacceptably high heart doses upon 3DCRT planning. Methods and Materials: In 49 patients (38 patients received 3DCRT; 11 patients received IMRT; and 20 patients received neoadjuvant or adjuvant chemotherapy) magnetic resonance imaging (MRI) and echocardiography were performed before and at 6, 12, and 24 months after treatment. Results: Mean heart dose for IMRT was 12.9 ± 3.9 Gy versus 4.5 ± 2.4 Gy for 3DCRT. Heart volumes receiving >40 Gy were 2.6% (3DCRT) versus 1.3% (IMRT); doses were >50 Gy only with 3DCRT. Temporary ejection fraction (EF) decrease was observed on MRI after 6 months (63%-59%, P=.005) resolving at 24 months. Only 3 patients had pronounced largely transient changes of EF and left ventricular enddiastolic diameter (LVEDD). Mitral (M) and tricuspid (T) annular plane systolic excursion (MAPSE and TAPSE) were reduced over the whole cohort (still within normal range). After 24 months left ventricular remodeling index decreased in patients receiving chemotherapy (0.80 vs 0.70, P=.028). Neither wall motion abnormalities nor late enhancements were found. On echocardiography, in addition to EF findings that were similar to those on MRI, global strain was unchanged over the whole cohort at 24 months after a transient decrease at 6 and 12 months. Longitudinal strain decreased in the whole cohort after 24 months in some segments, whereas it increased in others. Conclusions: Until 24 months after risk-adapted modern multimodal adjuvant therapy, only subclinical cardiac changes were observed in both 3DCRT patients with inclusion of small to moderate amounts of heart volume in RT tangents and in the patients treated with IMRT and reduced high-dose heart exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Alternating Chemoradiotherapy Consisting of Extended-Field Dynamic Conformational Radiotherapy and Systemic Chemotherapy Using 5-FU and Nedaplatin for Patients in High-Risk Group With Cervical Carcinoma

Purpose: To assess the efficacy of alternating chemoradiotherapy combined with extended-field conformal radiotherapy for patients with high-risk cervical cancer. Methods and Materials: Patients with previously untreated cervical cancer, with Stage III/IVA disease, or Stage IB/II with high-risk factor (primary tumor diameter {>=}50 mm or positive lymph node) were entered into this study. Three cycles of chemotherapy with 3,500 mg/m{sup 2} of 5-fluorouracil (5-FU) and nedaplatin (NDP) were accompanied with pelvic irradiation of 45.6-51.3 Gy in 24-27 fractions over 6 weeks. Prophylactic (36 Gy/20 fractions) or definitive (45-56 Gy) irradiation for para-aortic region was followed by pelvic irradiation. Results: Between 1998 and 2004, 40 patients were recruited for this protocol study. Eighteen patients from Phase I setting were registered. Twenty-two patients were treated with NDP of 140 mg/m{sup 2} (the recommended dose) in the Phase II segment. Twenty-five patients had T3 disease, and 25 patients had nodal disease including para-aortic involvement (n = 5). Overall/progression-free survival rates at 5 years were 78.8 and 66.5%, respectively. The median follow-up time was 61.8 months (25.5-106.7). Hematologic and gastrointestinal Grade 3 or more toxicities were relatively high rate (27.5-45%); however, they were well manageable. Two for bladder toxicity of Grade 3 were noted. Comparing the data from historical control group evaluated by magnetic resonance imaging, alternating chemoradiotherapy revealed a significant favorable factor for survival and disease recurrence in multivariate analysis (p < 0.05). Conclusion: Acquired results from our unique protocol for cervical cancer with high-risk factor were thought to be promising, considering that the majority of our cohort consisted of high-risk population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification and modeling of mechanical degradation in lithium-ion batteries based on nanoscale imaging

Capacity fade in lithium-ion battery electrodes can result from a degradation mechanism in which the carbon black-binder network detaches from the active material. Here we present two approaches to visualize and quantify this detachment and use the experimental results to develop and validate a model that considers how the active particle size, the viscoelastic parameters of the composite electrode, the adhesion between the active particle and the carbon black-binder domain, and the solid electrolyte interphase growth rate impact detachment and capacity fade. Using carbon-silicon composite electrodes as a model system, we demonstrate X-ray nano-tomography and backscatter scanning electron microscopy with sufficient resolution and contrast to segment the pore space, active particles, and carbon black-binder domain and quantify delamination as a function of cycle number. The validated model is further used to discuss how detachment and capacity fade in high-capacity materials can be minimized through materials engineering.

Science & Technology - Other Topics↗

Insights Into Thermal Runaway Mechanisms: Fast Tomography Analysis of Metal Agglomerates in Lithium-Ion Batteries

Thermal Runaway (TR) in lithium-ion batteries (LIB) is a critical technological and social concern. Whilst such events are rare, TR is characterized by uncontrollable heating leading to catastrophic failures. To deepen the understanding of the failure process and subsequently develop more accurate TR prediction models and as a result safer battery systems, we present in this work high-speed X-ray tomography for in-depth investigations of the copper current collector melting and agglomeration during TR. The melting process presents valuable real-time internal information about heat evolution during TR, previously challenging to access but crucially important for validating TR models. In this work, controlled failure studies combined with high-speed X-ray tomography were performed on two different commercial LIB models, subjecting them to both external heating and nail penetration to induce TR. Through real-time observation via high-speed tomography, followed by segmentation, rendering, and analysis, the formation of copper agglomerates was qualitatively and quantitatively characterized and visualized for the first time. Agglomerates tended to form either from the battery's outermost layers or centrally, depending on the method of TR initiation, and gives an indirect insight into the internal temperature evolution and distribution. Moreover, an initial comparative analysis between the battery models also revealed differences in agglomerate size, which has been linked to the thicker copper current collectors of one of the cell models. We further discuss the impact of larger copper agglomerates on heat distribution and safety. This study not only sheds light on the intricate dynamics of TR in LIBs but also underscores the pivotal role of 'gold-standard' imaging techniques in advancing battery safety, crucial for the robust modeling of TR and the future design of electric vehicle safety systems.

25 ENERGY STORAGE↗

Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r{sup 2} = 0.772, mean r{sup 2} = 0.562) and for organ volume versus height (max r{sup 2} = 0.781, mean r{sup 2} = 0.601). Conclusions: Adult patients exhibited small variations in organ volume and location with respect to height and weight, but no meaningful correlation existed between these parameters and age or BMI. Once adulthood is reached, organ morphology and positioning seem to remain static. However, clear trends are evident between pediatric organ locations versus age, height, and weight. Such information can be incorporated into a matching methodology that may provide the highest probability of representing the anatomy of a patient undergoing a clinical exam to prospectively estimate the radiation dose.

60 APPLIED LIFE SCIENCES↗

Coplanar intensity-modulated radiotherapy class solution for patients with prostate cancer with bilateral hip prostheses with and without nodal involvement

Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beam angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm{sup 3}) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V{sub 50} {sub Gy} objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

MO-AB-BRA-09: Temporally Realistic Manipulation a 4D Biomechanical Lung Phantom for Evaluation of Simultaneous Registration and Segmentation

Purpose: To produce multi-modality compatible, realistic datasets for the joint evaluation of segmentation and registration with a reliable ground truth using a 4D biomechanical lung phantom. The further development of a computer controlled air flow system for recreation of real patient breathing patterns is incorporated for additional evaluation of motion prediction algorithms. Methods: A pair of preserved porcine lungs was pneumatically manipulated using an in-house computer controlled respirator. The respirator consisted of a set of bellows actuated by a 186 W computer controlled industrial motor. Patient breathing traces were recorded using a respiratory bellows belt during CT simulation and input into a control program incorporating a proportional-integral-derivative (PID) feedback controller in LabVIEW. Mock tumors were created using dual compartment vacuum sealed sea sponges. 65% iohexol,a gadolinium-based contrast agent and 18F-FDG were used to produce contrast and thus determine a segmentation ground truth. The intensity distributions of the compartments were then digitally matched for the final dataset. A bifurcation tracking pipeline provided a registration ground truth using the bronchi of the lung. The lungs were scanned using a GE Discovery-ST PET/CT scanner and a Phillips Panorama 0.23T MRI using a T1 weighted 3D fast field echo (FFE) protocol. Results: The standard deviation of the error between the patient breathing trace and the encoder feedback from the respirator was found to be ±4.2%. Bifurcation tracking error using CT (0.97×0.97×3.27 mm{sup 3} resolution) was found to be sub-voxel up to 7.8 cm displacement for human lungs and less than 1.32 voxel widths in any axis up to 2.3 cm for the porcine lungs. Conclusion: An MRI/PET/CT compatible anatomically and temporally realistic swine lung phantom was developed for the evaluation of simultaneous registration and segmentation algorithms. With the addition of custom software and mock tumors, the entire package offers ground truths for benchmarking performance with high fidelity.

60 APPLIED LIFE SCIENCES↗

Chemoembolization for Hepatocellular Carcinoma Supplied by a Lumbar Artery

PurposeTo describe the radiologic findings and imaging response of hepatocellular carcinoma (HCC) supplied by the lumbar artery.MethodsBetween April 2004 and December 2012, we encountered HCC supplied by a lumbar artery in 21 patients. Two investigators retrospectively reviewed clinical and radiological findings of HCC supplied by the lumbar artery using computed tomography (CT) scans and digital subtraction angiograms.ResultsPatients had received 1–27 sessions of previous chemoembolization procedures (mean 7.7 sessions, median 4 sessions). Mean tumor size was 5.3 cm. The locations of HCC supplied by lumbar artery were the bare area (n = 14, 67 %) and segment VI (n = 7, 33 %). Tumor-feeding arteries arose from the main lumbar artery (n = 7), proximal anterior division (n = 4), and distal anterior division (n = 14). In 20 patients, selective chemoembolization through the tumor-feeding arteries of the lumbar artery was achieved. In 1 patient, nonselective embolization at the main lumbar artery was performed. There was no complication such as skin necrosis or paralysis. On the first follow-up enhanced CT scan, target tumors fed by the lumbar artery showed complete response (n = 6), partial response (n = 4), stable disease (n = 3), and progressive disease (n = 8), but overall tumor response was partial response (n = 1) and progressive disease (n = 20).ConclusionWhen HCC is located in the inferior tip or bare area of the liver, a lumbar artery may supply the tumor. Although selective chemoembolization via the tumor-feeding vessel of the lumbar artery can be achieved in most cases, overall tumor response is commonly unfavorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗