A uranium bed with ceramic body for tritium storage
It is widely recognized that ceramic coatings provide an attractive solution to lower tritium permeation in structural materials. Alumina based ceramic coatings have the highest permeation reduction factor for hydrogen. For this reason an attempt was made to apply crack-free low porous ceramics as a structural material of a bed body for tritium storage in a setup used for hydrogenating neutron tube targets at VNIIA. The present article introduces the design of the bed. This bed possesses essentially a lower hydrogen permeation factor than traditionally beds with stainless steel body. Bed heating in order to recover hydrogen from the bed is suggested to be implemented by high frequency induction means. Inductive heating allows decreasing the time necessary for tritium release from the bed as well as power consumption. Both of these factors mean less thermal power release into glove box where a setup for tritium handling is installed and thus causes fewer problems with pressure regulations inside the glove box. Inductive heating allows raising tritium sorbent material temperature up to melting point. The latter allows achieving nearly full tritium recovery.