Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Evaluation of Experimental Shroud Designs for the Hyperion 5201W Infrasound Sensor

Sandia National Laboratories has tested and evaluated various infrasound shrouds, produced Doug Seastrand and Gary Walker, DOE staff in Las Vegas, Nevada, intended for a Hyperion 5201W digital infrasound sensor. The purpose of these shrouds is to improve the infrasound sensor’s attenuation of incoherent signals, specifically those caused by wind passing by the sensor. The purpose of the shroud evaluation was to measure amplitude and phase of the sensors with a variety of shroud designs attached and determine whether there is any appreciable changes in amplitude and/or phase response over the IMS passband for infrasound applications, 0.02 Hz to 4.0 Hz. These shrouds utilize a tubule design that directs and mixes airflow from ports radially distributed at approximately 90 degree offsets in an attempt to minimize wind-generated signal due to Bernoulli effect caused by airflow passing by ports perpendicular to the wind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Instance learning Framework for Seismic Detectors

In this report, we construct and test a framework for fusing the predictions of a ensemble of seismic wave detectors. The framework is drawn from multi-instance learning and is meant to improve the predictive skill of the ensemble beyond that of the individual detectors. We show how the framework allows the use of multiple features derived from the seismogram to detect seismic wave arrivals, as well as how it allows only the most informative features to be retained in the ensemble. The computational cost of the "ensembling" method is linear in the size of the ensemble, allowing a scalable method for monitoring multiple features/transformations of a seismogram. The framework is tested on teleseismic and regional p-wave arrivals at the IMS (International Monitoring System) station in Warramunga, NT, Australia and the PNSU station in University of Utah's monitoring network.

58 GEOSCIENCES↗

2018 Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Kinemetrics Q330M+ digitizers. The digitizers are intended to record sensor output for seismic and infrasound monitoring applications. Notable improvements to the Q330M+ include the support for transmission and authentication of CD1.1 data, integration of analog and digital weather stations, support for multiple gain amplification levels, and the use of a webpage for status and configuration of the digitizer. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Technical Issues in the Comprehensive Nuclear Test Ban Treaty (CTBT) Ratification Debate: A 20 Year Retrospective

Two decades after the U.S. Senate declined in 1999 to give its consent to ratification of the Comprehensive Nuclear Test Ban Treaty (CTBT), the treaty remains in legal and political limbo. Legally, the treaty cannot enter into force without U.S. ratification. However, the Senate’s rejection does not strip the treaty of its force as an element of customary international law or alter the will of other signatories to see it enter into force. Politically, the debate over the virtues and flaws of the treaty remains as strong as ever, with some CTBT advocates pushing energetically for U.S. re-review while some opponents seek ways to “un-sign” the treaty. Meanwhile, despite the Senate’s rejection of the treaty, the United States acts in a manner consistent with its main obligations by maintaining a moratorium on explosive nuclear testing and providing financial support (as well as technical expertise) to the CTBT Organization (CTBTO)—in particular the CTBTO’s International Monitoring System (IMS). The CTBT may well remain in such limbo for a long time to come, unless some catalytic event comes along to re-shape national perceptions and priorities, one way or the other. The treaty’s future, whatever it might be, will be determined in part by how much perspectives might have changed in light of interim developments. Our purpose is to shed light on some of those developments and to assess their relevance. The 1999 ratification debate addressed a large number of issues. Rejection was driven by various policy and technical judgments. The purpose of this paper is to re-examine those technical judgments in light of what has been learned over the following two decades. On some technical matters, there was explicit recognition of extant uncertainties, as well as a conviction and hope that time would dispel them. To be doubly clear, our purpose is not to recommend a way forward on CTBT ratification. The policy judgments of 1999 and 2020 are beyond the scope of this paper. This technical re-examination proceeds as follows. It begins with a short background section to introduce the key technical matters in discussion in the U.S. ratification process. Then it moves systematically through each of those topics with a review of relevant background information, a discussion of key points in debate, an analysis of subsequent experience, and a current assessment. The historical analysis draws on many sources including the primary documents of the Congressional debate, the official article-by-article interpretation by the Department of State, and the statements of key players in the process. We also relied on key technical reports and publications by subject matter experts that have addressed in more detail many of the issues in our focus. These sources include the 2002 and 2012 reports of the National Academy of Sciences as well as publications by senior technical staff of Lawrence Livermore National Laboratory (LLNL) who were actively involved in the ratification debate, including then-Laboratory Director Bruce Tarter. We also conducted several interviews with government officials from the 1990s, past laboratory directors, and other members of the scientific community. But, except where individuals are specifically cited by name, the judgments offered here are our own and should not be attributed to any other individual or to LLNL as such.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

RASA Field Performance at US International Monitoring Stations

This report attempts to collate, analyze, and summarize RASA performance over time at each of 11 US operated IMS stations. The performance over time was compared to routine maintenance operations. The data, in general, were summarized into a set analyzed almost exclusively in Excel. The data set allows for further probing into RASA performance over time. The data set would permit data to be routinely added for continued analysis. In general, all RASA systems ran within the CTBTO mandated the MDA requirements over their current lifetime of operations. The largest impacts to performance appeared to arise from variabilities of Germanium gamma detectors as they were replaced. It is noted that the air volumes of samples were not provided and had to be assumed to be constant over the period analyzed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examining Nuisance Aerosol Detections in Light of the Origin of the Screening Process (November 2021)

The evolution of philosophy and computations in the International Data Center (IDC) related to aerosol samples have had profound impacts on the number of recorded detections in the network since routine operations began in 2000. Key decisions from policymakers have been the list of triggering radionuclides, the scheme for categorizing these into interest levels 1-5, and an algorithm for determining when an anthropogenic isotope is seen so often that it is no longer interesting, known as the Exponential Weighted Moving Average (EWMA). These are described in the Operations Manual of the IDC. Key parameters that are controlled by the IDC but for which the IDC receives occasional input from policymakers include the constants in EWMA and the peak significance threshold for individual gamma rays, the latter of which directly leads to determination of the presence or absence of a radionuclide in a sample. There are also changes in computations which the IDC makes and informs policy makers about, such as changes in how background is computed, which could also affect the ease of detecting a peak – real or false. Rather than focus on the quantitative changes due to computation changes, this work records some thinking on how isotopes and peak significance levels were chosen, and the resulting detections seen over 18 years during the buildup of the International Monitoring System (IMS). These detections are considered on a global scale to try to determine the relative impact on monitoring, and in some cases, the nature of their existence. Repeated detections of 131I and 133I are the most troublesome, but they are not so frequent to be a major problem for the Verification Regime. These detections could probably be handled adequately using scientific methods currently under development for xenon backgrounds. It is also somewhat problematic that top-level analysis of aerosol backgrounds has not been reported previous to this. The steep increase in the rate of detections after 2016 are a concern, either in the actual backgrounds or from changes in the calculations methods used to generate the Reviewed Radionuclide Report (RRR.) Final conclusions of the authors are that the computational stability of the RRR is very important. With computational stability, changes can be usefully analyzed as being due to changes in radioactivity in Earth’s atmosphere This report is a distillation into text of a talk given in the Radionuclide Experts Group (RNEG) in Vienna during Working Group B (WGB) in February of 2019. This report does not directly contain any IDC data, only summaries by year, or by isotope, or by location. No specific IDC detection by time, location, or isotope is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additively Manufactured Tamper Evident Container (TEC)

The protection of sensitive data, proprietary information, and physical assets from adversarial disclosure is a high priority in today’s environment of government and industrial espionage. Furthermore, knowledge of the security history and monitoring for potential acquisition or disclosure of the protected assets from oppositional sources is equally important. In 2016, as part of an LANL Institute for Materials Science (IMS) rapid response research initiative, the investigators of this technology demonstration project developed the concept of an additively manufactured tamper resistant container that possessed tamper evident features. Tamper evident seals and detection technologies have a long history in protecting consumers from product tampering, recording the installation and activation of mechanical safety panels and fasteners on dangerous electro-mechanical systems, and serving as a warranty void indicator on expensive electronic equipment. Examples of such tamper evident seals range from “no-tech” versions, e.g., the paper seals under medicine caps, to “high-tech” seals that are radio frequency-active and include encryption capabilities used by the International Atomic Energy Agency (IAEA) to monitor stored nuclear materials in support of safeguards missions. The tamper evident container (TEC) technology would have many uses.

36 MATERIALS SCIENCE↗

2022 MB3a Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated an updated version of the MB3a infrasound sensor, designed by CEA and manufactured by SeismoWave. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The MB3a infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

2022 Chaparral 64S Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated a new version of the Chaparral 64S infrasound sensor, designed and manufactured by Chaparral Physics. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The Chaparral 64S infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Bayesian Seismoacoustic Source Location: Acoustic Approach

Seismic waves and infrasound are key technologies in the International Monitoring System (IMS) to monitor explosive events in the solid Earth and atmosphere. Energetic man-made or natural events (e.g., chemical/nuclear explosions, volcanic eruptions, and earthquakes) near the Earth’s surface produce both ground motion and atmospheric pressure disturbances which propagate as seismic waves and infrasound, respectively. Seismic waves have been generally used to detect and identify underground and near-surface events (Myers, et. al., 2007), and infrasound are sensitive to events near the surface or in the atmosphere (Modrak et. al., 2010). Due to their different sensitivities to events, they can complement to each other to improve the event detection and discrimination. The framework of joint seismoacoustic event location has recently reviewed by theoretical research (Koch and Arrowsmith, 2019). Although the early applications showed promising results to improve the accuracy of event location, their application were still limited to a small set of events selected to prove the concepts, and practical capability of the method for operational purpose is not fully evaluated with data. Our final goal is to apply the method of seismoacoustic event location to a larger set of events and evaluate its applicability for operational event location in practice. To that end, we focus on developing and verifying acoustic source location method in this study.

58 GEOSCIENCES↗

Summary of NDC Capacity Building Workshop and Regional Seismic Travel Time (RSTT) in combination with Data Sharing and Integration Training

The NNSA Seismic Cooperation Program (SCP) sponsored Stephen Myers (LLNL), Michael Begnaud (LANL), Brian Young (SNL) and Istvan Bondar (Research Center for Astronomy and Earth Sciences, Hungary) to serve as a presenters/trainers at the “NDC Capacity Building Workshop and Regional Seismic Travel Time (RSTT) in combination with Data Sharing and Integration Training” September 4-8 2022 in Muscat, Oman (See Appendix A for the agenda). The workshop and training (workshop from here forward) was organized by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS). The first half of the week was devoted to NDC workshop activities, and the second half was devoted to RSTT training. Fifty-five participants from 27 countries and the CTBTO-PTS attended the 5-day workshop (See Appendix B for list of participants and countries of origin). Presentations from the PTS described the International Monitoring System (IMS), International Data Centre (IDC) products, and metrics of regional data utilization. Contributed presentations from each country’s scientists included descriptions of regional and national networks, methods of data analysis, and needs for material and technical assistance. Training included an overview of the RSTT method and instruction on how to locate seismic events with the iLoc program, which utilizes RSTT travel times to reduce bias in event location estimates. Methods of seismic tomography and the need for a high-quality tomographic set, including seismological “ground truth”, were emphasized. Seismological “ground truth” or “GT” is a term that has come to mean both events with known location and events with well-characterized locations that are estimated using seismological data, typically with epicenter accuracy of 5 km or better. Notably, the instructional platform has migrated from UNIX shell scripts to Jupyter Notebooks. Jupyter Notebooks have the advantage being more visually intuitive, including display of graphics within the notebook. Each notebook includes every processing step that participants need to reproduce the entire exercise.

58 GEOSCIENCES↗

Next Generation Chemical Agent Detection Architecture [Poster]

Sandia National Labs (SNL)-designed, portable chemical warfare agent (CWA) detection systems consist of three-stages: collection, separation, and detection. We use microfabrication technologies to miniaturize these stages and to reduce the overall size, weight, power, and (potentially) cost of the final system. Our newest system consists of a multi-dimensional separation stage and an miniature ion mobility spectrometer (IMS) detector for unprecedented system sensitivity, selectivity, and depth of target list.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Independent Technical Review of the Interim Measure Alternatives Analysis for Chromium Contamination in Groundwater at Los Alamos National Laboratory, New Mexico

The two example scenarios described in the report are built around either boundary condition modification or pump and treat. Boundary condition modification focuses primarily on aggressively reducing the driving force of water that is moving Cr(VI) through the subsurface system at LANL, carefully monitoring hydrologic responses, and quantifying natural attenuation rates in key portions of the plume. This scenario would provide a measurable impact on subsurface hydrology using relatively low-cost methods and emphasizing data collection to support the CME process. The second scenario focuses on active removal of Cr(VI) using pump and treat combined with a variety of data collection activities. This scenario would also include some boundary condition modification and would provide more timely impacts in the mid-plume area. However, it is substantially more costly and faces more significant logistical, regulatory, and data interpretation hurdles. Because of these issues and challenges, the pump and treat based scenario would be appropriate primarily for the case in which Cr(VI) removal and more rapid near-term impacts in the mid-plume are considered to be high, overriding priorities. We recommend careful consideration of the advantages and disadvantages of different “combined remedy” IM scenarios and urge the LANL team and its regulators and stakeholders to assemble and select a scenario that is implementable and that provides useful and actionable data to inform and support the CME. Both of the example scenarios presented meet these criteria.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Agilent AgileBioFoundry CRADA (Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOF-MS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Therefore, our accomplishment in this CRADA improved the efficiency and accuracy of strain testing by developing and implementing fast analytical methods, robust processing tools, and software for predicting the best methods for UHPLC analysis.

97 MATHEMATICS AND COMPUTING↗

FY14 Progress Report for PL12-LaserSPec SIMS-PD08: Laser Photoionization of Sputtered Neutral atoms in PNNL SIMS and Applications in Nuclear Materials and Environmental Analyses

A continuous wave (CW) Ar ion laser producing photons at 244 nm (doubled from the fundamental wavelength at 488nm) was used to ionize neutrals sputtered from representative lanthanide (neodymium oxide, Nd 2 O 3 ) and actinide (uranium oxide, U 3 O 8 ) containing materials in the modified Cameca ims-4f at PNNL.

36 MATERIALS SCIENCE↗