Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Magnetic materials selection for static inverter and converter transformers

Different magnetic alloys best suited for high-frequency and high-efficiency applications were comparatively investigated together with an investigation of each alloy's inherent characteristics. One of the characteristics in magnetic materials deterimental in transformer design is the residual flux density, which can be additive on turn-on and cause the transformer to saturate. Investigation of this problem led to the design of a transformer with a very low residual flux. Tests were performed to determine the dc and ac magnetic properties at 2400 Hz using square-wave excitation. These tests were performed on uncut cores, which were then cut for comparison of the gapped and ungapped magnetic properties. The optimum transformer was found to be that with the lowest residual flux and a small amount of air gap in the magnetic material. The data obtained from these tests are described, and the potential uses for the materials are discussed.

Mclyman, C. W. T.↗

Respiratory analysis system and method

A system is described for monitoring the respiratory process in which the gas flow rate and the frequency of respiration and expiration cycles can be determined on a real time basis. A face mask is provided with one-way inlet and outlet valves where the gas flow is through independent flowmeters and through a mass spectrometer. The opening and closing of a valve operates an electrical switch, and the combination of the two switches produces a low frequency electrical signal of the respiratory inhalation and exhalation cycles. During the time a switch is operated, the corresponsing flowmeter produces electric pulses representative of the flow rate; the electrical pulses being at a higher frequency than that of the breathing cycle and combined with the low frequency signal. The high frequency pulses are supplied to conventional analyzer computer which also receives temperature and pressure inputs and computes mass flow rate and totalized mass flow of gas. From the mass spectrometer, components of the gas are separately computed as to flow rate. The electrical switches cause operation of up-down inputs of a reversible counter. The respective up and down cycles can be individually monitored and combined for various respiratory measurements.

Liu, F. F.↗

Magnetic materials selection for static inverter and converter transformers

A program to study magnetic materials is described for use in spacecraft transformers used in static inverters, converters, and transformer-rectifier supplies. Different magnetic alloys best suited for high-frequency and high-efficiency applications were comparatively investigated together with an investigation of each alloy's inherent characteristics. The materials evaluated were the magnetic alloys: (1) 50% Ni, 50% Fe; (2) 79% Ni, 17% Fe, 4% Mo; (3) 48% Ni, 52% Fe; (4) 78% Ni, 17% Fe, 5% Mo; and (5) 3% Si, 97% Fe. Investigations led to the design of a transformer with a very low residual flux. Tests were performed to determine the dc and ac magnetic properties at 2400 Hz using square-wave excitation. These tests were performed on uncut cores, which were then cut for comparison of the gapped and ungapped magnetic properties. When the data of many transformers in many configurations were compiled the optimum transformer was found to be that with the lowest residual flux and a small amount of air gap in the magnetic material. The data obtained from these tests are described, and the potential uses for the materials are discussed.

Mclyman, W. T.↗

Development of a ruggedized 20-watt, 2.3- gigahertz transistor

This program was to develop a ruggedized transistor capable of meeting the following CW objectives at 2.3 gigahertz: a power output of 20 watts, a power gain of 6 db, and an efficiency of 40 percent. Devices developed produced the following CW performance at 2.3 gigahertz: a power output of 23 watts, a power gain of 7.7 db, and an efficiently of 40.0 percent. This performance was achieved with an eight-cell TA8407 transistor design having the following modifications: a thin pellet, high-frequency diffusion, high-level emitter ballasting, an optimized emitter-bonding configuration for uniform power sharing, and a package that provides for some internal matching through the use of distributed line techniques.

Source record↗

Investigations of the ionospheric using radio signals from artificial satellites

The occurrence and characteristics of ionospheric irregularities in medium latitudes and in polar regions were measured using radio signals from artificial satellites. Ionospheric changes during quiet and disturbed conditions were also measured. Electron density, elevation angle, and amplitude and frequency of these high frequency signals were determined as well as the direction of their arrival.

Titheridge, J. E.↗

Improved interferometer beam splitter

Cat's-eye retroreflector attached to motor driven lead screw allows low-frequency changes in optical path. Moving-coil actuator attached to other retroreflector allows mid-frequency movements. High-frequency movements are achieved by employing piezoelectric transducer attached to secondary mirror of same retroreflector.

Schindler, R. A.↗

Anthropomorphic master/slave manipulator system

An anthropomorphic master/slave manipulator system including master arm apparatus with a plurality of master tubular articulated portions is outlined. Objectives of this investion were to provide a system that accurately and smoothly simulates human limb movement at a remote location. The system has a high frequency response, a high structural stiffness and a design that protects the components of the slave mechanism. Simulation of human movements is possible in outer space, underwater, and in a hazardous environment such as in a high radiation area. The equivalent ability, dexterity, and strength of a human arm are simulated.

Vykukal, H. C.↗

Aerodynamic prediction I

The aerodynamic prediction methodology which is needed for rotor noise calculations is presented. Airloads and wakes, dynamic stall, compressible flow, and random loads are reviewed. The aerodynamics/acoustics interface is defined when the noise or measurements are considered. The classical approach involving a distinct separation of aerodynamic sources and acoustic propagation is the basis of most rotor noise calculations. Aeroacoustics of rotors involve unique features which are not encountered in other aerodynamic problems of rotors: (1) acoustics problems ultimately require only an order of magnitude estimate of the sound pressure field, consequently remarkably good noise predictions are obtained from very simple aerodynamic analyses; (2) aeroacoustics introduce an interest in the higher frequency aerodynamics, the deterministic aerodynamic phenomena are still low frequency, however, the high frequency noise comes from the acoustic propagation; and (3) the aerodynamic phenomena on rotors that are only of interest due to the noise they produce, are the random aerodynamic pressures on the blades.

Johnson, W.↗

Microwave and millimeter-wave power generation in silicon carbide avalanche devices

Numerical simulations were performed to investigate the typical power-generating capabilities of SiC IMPATT diodes. Using available material parameters, SiC double-drift IMPATT diodes were simulated at 10, 35, 60, and 94 GHz, and the operating characteristics of these devices were compared to those of Si and GaAs devices. Compared to the Si and GaAs IMPATT performances in the pulsed mode, the SiC IMPATT performance was found to be far superior. The performance of SiC devices in the CW mode was also superior to that of GaAs devices, especially at lower frequencies. At a high frequency (94 GHz), the performance of the SiC device was found to be comparable to that of Si devices.

Mehdi, I.↗

Design considerations for beamwaveguide in the NASA Deep Space Network

A generalized solution is found for retrofitting a large dual-shaped reflector antenna for a beamwaveguide. The design is termed as a bypass beamwaveguide. Both highpass design feed imaging and bandpass design feed imaging are considered. Each design was studied using geometrical optics, Gaussian wave analysis, and both low-frequency and high-frequency diffraction analysis. An important extension of the Mizusawa-Kitsuregawa criteria was discovered (Zusama and Kitsuregawa, 1973). The principle revealed shows how a two-reflector cell, although in itself distorting, may be combined with a second cell which compensates for the first and delivers an output beam which is a good image of the input beam.

Veruttipong, Thavath↗

Resonant-tunneling oscillators and multipliers for submillimeter receivers

Resonant tunneling through double-barrier heterostructures has attracted increasing interest recently, largely because of the fast charge transport it provides. In addition, the negative differential resistance regions that exist in the current-voltage (I-V) curve (peak-to-valley ratios of 3.5:1 at room temperature, and nearly 10:1 at 77 K, were measured) suggest that high-speed devices based on the character of the I-V curve should be possible. For example, the negative differential resistance region is capable of providing the gain necessary for high-frequency oscillations. In the laboratory attempts were made to increase the frequency and power of these oscillators and to demonstrate several different high-frequency devices.

Sollner, T. C. L. Gerhard↗

Radial evolution of the high/low frequency breakpoint in magnetic field spectra

The spectra of magnetic field variations in the solar wind show different behavior in two frequency regions; a high frequency region in which the spectral exponent is about -5/3 and a low frequency region in which it is typically -1. The two types of variations must arise from different processes and a clue to the relationship between the spectral regions lies in understanding the behavior of the breakpoint between the spectral regions. Studies of the average behavior of spectra have shown that the break point occurs at about 3.5 hours at 1 AU. It is also known that, on average, the breakpoint occurs at lower frequencies with larger heliocentric distances. Ideally however, instead of the average properties of the spectra, we would like to know how the breakpoint evolves in particular samples of the solar wind as they propagate to larger heliocentric distances. In the study reported here we take advantage of the fact that, in 1974, Pioneer 10 (4.4 AU) and Pioneer 11 (5.6 AU) were close to being co-aligned and being aligned with the Earth. Solar wind observed at Earth can be closely matched with solar wind later observed at P10 and P11. We here compare the breakpoint observed at Earth with that observed at Pioneers 10 and 11 for matched samples of the wind.

Feynman, J.↗

Commercialization and Industrial Development for the Fetal Hear Rate Monitor

The primary objectives for this task were to continue the development and testing of the NASA/ODU passive acoustic fetal heart rate monitor, with the goal of transferring the technology to the commercial sector. Areas of work included: 1. To assist in the development of a new hardware front end electronics box for the fetal heart rate monitor, so as to reduce the size of the electronics box, and also to provide for a "low-frequency" and "high-frequency" mode of operation. To make necessary changes in the operating software to support the two modes of operation. 2. To provide an option for a strip chart recording for the system, so that medical personnel could more easily make comparisons with ultra sound strip chart recordings. and 3. To help with continued testing of the system.

Zahorian, Stephen↗

Helicon Plasma Source Optimization Studies for VASIMR

A helicon plasma source at Oak Ridge National Laboratory is being used to investigate operating scenarios relevant to the VASIMR (VAriable Specific Impulse Magnetoplasma Rocket). These include operation at high magnetic field (> = 0.4 T), high frequency (<= 30 MHz), high power (< = 3 kW), and with light ions (He+, H+). To date, He plasmas have been produced with n(sub e0) = 1.7 x 10(exp 19)/cu m (measured with an axially movable 4mm microwave interferometer), with Pin = I kW at f = 13.56 MHz and absolute value of B(sub 0) = 0.16 T. In the near future, diagnostics including a mass flow meter and a gridded energy analyzer array will be added to investigate fueling efficiency and the source power balance. The latest results, together with modeling results using the EMIR rf code, will be presented.

Goulding, R. H.↗

Chronic orthostatic intolerance: a disorder with discordant cardiac and vascular sympathetic control

BACKGROUND: Chronic orthostatic intolerance (COI) is a debilitating autonomic condition in young adults. Its neurohumoral and hemodynamic profiles suggest possible alterations of postural sympathetic function and of baroreflex control of heart rate (HR). METHODS AND RESULTS: In 16 COI patients and 16 healthy volunteers, intra-arterial blood pressure (BP), ECG, central venous pressure (CVP), and muscle sympathetic nerve activity (MSNA) were recorded at rest and during 75 degrees tilt. Spectral analysis of RR interval and systolic arterial pressure (SAP) variabilities provided indices of sympathovagal modulation of the sinoatrial node (ratio of low-frequency to high-frequency components, LF/HF) and of sympathetic vasomotor control (LFSAP). Baroreflex mechanisms were assessed (1) by the slope of the regression line obtained from changes of RR interval and MSNA evoked by pharmacologically induced alterations in BP and (2) by the index alpha, obtained from cross-spectral analysis of RR and SAP variabilities. At rest, HR, MSNA, LF/HF, and LFSAP were higher in COI patients, whereas BP and CVP were similar in the two groups. During tilt, BP did not change and CVP fell by the same extent in the 2 groups; the increase of HR and LF/HF was more pronounced in COI patients. Conversely, the increase of MSNA was lower in COI than in control subjects. Baroreflex sensitivity was similar in COI and control subjects at rest; tilt reduced alpha similarly in both groups. CONCLUSIONS: COI is characterized by an overall enhancement of noradrenergic tone at rest and by a blunted postganglionic sympathetic response to standing, with a compensatory cardiac sympathetic overactivity. Baroreflex mechanisms maintain their functional responsiveness. These data suggest that in COI, the functional distribution of central sympathetic tone to the heart and vasculature is abnormal.

Non-NASA Center↗

Diamond Analyzed by Secondary Electron Emission Spectroscopy

Diamond is a promising semiconductor material for novel electronic applications because of its chemical stability and inertness, heat conduction properties, and so-called negative electron affinity (NEA). When a surface has NEA, electrons generated inside the bulk of the material are able to come out into the vacuum without any potential barrier (work function). Such a material would have an extremely high secondary electron emission coefficient o, very high photoelectron (quantum) yield, and would probably be an efficient field emitter. Chemical-vapor-deposited (CVD) polycrystalline diamond films have even more advantages than diamond single crystals. Their fabrication is relatively easy and inexpensive, and they can be grown with high levels of doping--consequently, they can have relatively high conductivity. Because of these properties, diamond can be used for cold cathodes and photocathodes in high-power electronics and in high-frequency and high-temperature semiconductor devices.

Krainsky, Isay L.↗

Silicon Carbide Solar Cells Investigated

The semiconductor silicon carbide (SiC) has long been known for its outstanding resistance to harsh environments (e.g., thermal stability, radiation resistance, and dielectric strength). However, the ability to produce device-quality material is severely limited by the inherent crystalline defects associated with this material and their associated electronic effects. Much progress has been made recently in the understanding and control of these defects and in the improved processing of this material. Because of this work, it may be possible to produce SiC-based solar cells for environments with high temperatures, light intensities, and radiation, such as those experienced by solar probes. Electronics and sensors based on SiC can operate in hostile environments where conventional silicon-based electronics (limited to 350 C) cannot function. Development of this material will enable large performance enhancements and size reductions for a wide variety of systems--such as high-frequency devices, high-power devices, microwave switching devices, and high-temperature electronics. These applications would supply more energy-efficient public electric power distribution and electric vehicles, more powerful microwave electronics for radar and communications, and better sensors and controls for cleaner-burning, more fuel-efficient jet aircraft and automobile engines. The 6H-SiC polytype is a promising wide-bandgap (Eg = 3.0 eV) semiconductor for photovoltaic applications in harsh solar environments that involve high-temperature and high-radiation conditions. The advantages of this material for this application lie in its extremely large breakdown field strength, high thermal conductivity, good electron saturation drift velocity, and stable electrical performance at temperatures as high as 600 C. This behavior makes it an attractive photovoltaic solar cell material for devices that can operate within three solar radii of the Sun.

Bailey, Sheila G.↗

Active Control of Separation From the Flap of a Supercritical Airfoil

Zero-mass-flux periodic excitation was applied at several regions on a simplified high-lift system to delay the occurrence of flow separation. The NASA Energy Efficient Transport (EET) supercritical airfoil was equipped with a 15% chord simply hinged leading edge flap and a 25% chord simply hinged trailing edge flap. Detailed flow features were measured in an attempt to identify optimal actuator placement. The measurements included steady and unsteady model and tunnel wall pressures, wake surveys, arrays of surface hot-films, flow visualization, and particle image velocimetry (PIV). The current paper describes the application of active separation control at several locations on the deflected trailing edge flap. High frequency (F(+) approximately equal to 10) and low frequency amplitude modulation (F(+) sub AM approximately equal to 1) of the high frequency excitation were used for control. It was noted that the same performance gains were obtained with amplitude modulation and required only 30% of the momentum input required by pure sine excitation.

Melton, LaTunia Pack↗