Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

BTO Market Success Report 2015–2020

This report highlights 28 BTO-supported, technology-oriented research and development (R&D) projects that resulted in the launch of a commercial product, focusing on identifying new technologies or commercialization updates between 2015 and 2020, where the product remained on the market as of March 2021. The report also includes a listing of the full 45 commercial products supported by BTO as well as a listing of 101 lighting components that benefited from BTO support and were commercialized and integrated into finished lighting products during the same timeframe.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Centering Energy and Environmental Justice in the Buildings Energy Sector

We face incredible challenges for decarbonizing our economy and raising the standard of living for all members of our society at the same time. Historical energy efficiency efforts have been effective in making small steps, but they fall far short of the massive changes we need to make, and they completely miss helping communities of disadvantage (e.g. low-income, African American, Hispanic American, Native American and tribal nations, etc). Business as usual efforts do not take the time to connect with and understand the challenges of these historical underinvested communities and therefore have not been effective at helping these communities. The Biden Harris Administration has set ambitious goals for decarbonization of our economy that include a requirement that 40% of efforts support energy and environmental justice communities. If we are to meet our decarbonization goals, it is imperative that we change our approach to research, development, and deployment of new technologies. The Department of Energy has set energy justice as a priority and is working with the national laboratories to change our approaches. This paper starts with definitions of what we mean by energy and environmental justice and how they apply to building technologies and deployment efforts. We provide several examples of how historical efforts have succeeded and how they have failed to account for challenges of communities of disadvantage. We identify market and technology barriers to decarbonization and energy efficiency for specific technologies and how these barriers are exacerbated for disadvantaged communities. From these examples, we propose a new framework for integrating energy and environmental justice into all aspects of technology development, deployment, and policy efforts within the building energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inventory of Clean Energy Education and Workforce Programs in Connecticut's I-91 Corridor

This document reports on the findings of an inventory of the educational and workforce development resources in a four-county area on the I-91 corridor in Connecticut. The overarching goal of this exercise is to help the local workforce leaders in Bridgeport, Connecticut to optimize their training programs to support the county's clean energy transition. The inventory generally finds that Fairfield County, where Bridgeport is located, lacks adequate education and training programs compared to other surrounding counties with similar populations. More than half of Fairfield County's programs occur through high school or career technical education programs, suggesting that there are minimal opportunities for workers who are not currently high school students. Much of the existing focus within Fairfield County is on general construction or plumbing and electrical skills. There is room to expand by offering more programs focusing on energy efficiency and renewable energy skills. The document outlines some potential next steps and questions for consideration for the local workforce leaders in Bridgeport. Bridgeport is a city located within Fairfield County in southwestern Connecticut. It is the largest city in Connecticut with an estimated population of 150,000. Through the Department of Energy-funded Communities LEAP program, NREL conducted an analysis of existing education and workforce development (EWD) programs located in Fairfield County that align with (or could support) the worker pipeline for occupations related to building energy efficiency (EE), renewable energy (RE), and clean energy manufacturing. The analysis also looked at EWD offerings in other counties in Connecticut as a point of comparison.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Condensing Gas Boilers

This report describes the implementation and impacts of a condensing gas boiler upgrade, which involves replacing existing boiler systems with condensing gas boilers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oakridge Geothermal Resources Assessment

Through the Communities Local Energy Action Program (LEAP), NREL provided technical assistance to a coalition of stakeholders from Oakridge, Oregon. The coalition included community-based non-profit organizations, the city government, the local utility, and others. Technical assistance provides analysis and information to support Oakridge stakeholders with their goals to increase energy reliability and resilience in the community, while promoting economic development. The Geothermal Resource Assessment provides technical analysis related to the geothermal resource in the Oakridge area, possible technology applications, and information related to further geothermal exploration. Technical analysis includes a review of a previous geothermal study conducted for Oakridge, thermal modeling to estimate reservoir temperatures, and technoeconomic simulation of a combined heat and power application in the Oakridge area.

15 GEOTHERMAL ENERGY↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Dual Fuel Heat Pump

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Dual Fuel Heat Pump" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗