Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Los Alamos County Fire Department LAFD: TA-55 PF-4 Facility Familiarization Tour, OJT 55260

Los Alamos National Laboratory (LANL) will conduct familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Plutonium Facility (PF-4) at Technical Area (TA)-55. These familiarization tours are official LANL business; the purpose of these tours is to orient the firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.

99 GENERAL AND MISCELLANEOUS↗

Comparison Between Surf and Multi-Shock Forest Fire High Explosive Burn Models

PAGOSA1 has several different burn models used to model high explosive detonation. Two of these, Multi-Shock Forest Fire and Surf, are capable of modeling shock initiation. Accurately calculating shock initiation of a high explosive is important because it is a mechanism for detonation in many accident scenarios (i.e. fragment impact). Comparing the models to pop-plot data give confidence that the models are accurately calculating detonation or lack thereof. To compare the performance of these models, pop-plots2 were created from simulations where one two cm block of PBX 9502 collides with another block of PBX 9502.

54 ENVIRONMENTAL SCIENCES↗

Sandia National Laboratories, Tonopah Test Range Fire Control Bunker (Building 09-51): Photographs and Written Historical and Descriptive Data

The Fire Control Bunker (Building 09-51) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons design. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

99 GENERAL AND MISCELLANEOUS↗

Demonstration of Advanced CO 2 Capture Process Improvements for Coal-Fired Flue Gas

This document summarizes the activities of Cooperative Agreement DE-FE0026590, “Demonstration of Advanced CO 2 Capture Process Improvements for Coal-Fired Flue Gas” during the performance period of October 1, 2015 through May 31, 2017. This project was funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL). Southern Company Services, Inc. (SCS) was the prime contractor and co-funder of the project. Mitsubishi Heavy Industries America (MHIA) and AECOM were project team members. The overall project objective was to improve costs, energy requirements, and performance of an existing amine-based CO 2 capture process. This will occur via improvements in three areas: 1. Reboiler design – The first objective of the program was to demonstrate performance of an integrated stripper/reboiler (termed Built-in Reboiler, or BIR) to reduce footprint, capital costs, and integration issues of the current technology. 2. Particulate management – The second objective was to carry out a Particulate Matter Management (PMM) test. This has the potential to reduce operating costs and capital costs due to the reduced or eliminated need for mechanical filtration. 3. Solvent – The third objective was to carry out a new solvent test plan (referred to as NSL) to demonstrate a new solvent (termed New Solvent A), which is expected to reduce regeneration steam. The bulk price is also expected to be lower than KS-1, which is the current solvent used in this process. NSL testing would include baseline testing, optimization, long term testing, solvent reclamation testing, and final inspection. These combine to form the Advanced Carbon Capture (ACC) technology. Much of this work will be applicable to generic solvent processes, especially in regards to improved reboiler design, and focused to meet or exceed the DOE’s overall carbon capture performance goals of 90% CO 2 capture rate with 95% CO 2 purity at a cost of $40/tonne of CO 2 by 2025 and at a cost of electricity (COE) 30% less than baseline CO 2 capture approaches by 2030. This project was divided into two phases. Phase 1 is the planning phase, and Phase 2 is the construction, operations, testing, and analysis phase. A down select occurred after Phase 1. Phase 1 activities were carried out during this reporting period, and therefore, Phase 1 activities are solely considered in this report. The project was not selected for Phase 2 funding.

01 COAL, LIGNITE, AND PEAT↗

Fission in R-processes Elements (FIRE) - Annual Report: Fiscal Year 2017

The goal of the FIRE topical collaboration in nuclear theory is to determine the astrophysical conditions of the rapid neutron capture process (r-process), which is responsible for the formation of heavy elements. This will be achieved by including in r-process simulations the most advanced models of fission (spontaneous, neutron-induced, beta-delayed) that have been developed at LLNL and LANL. The collaboration is composed of LLNL (lead) and LANL for work on nuclear data (ground-state properties, fission, beta-decay), BNL for nuclear data management, and the university of Notre Dame and North Carolina State University for r-process simulations. Under DOE/NNSA agreement, both universities receive funds from the DOE Office of Science, while national laboratories receive funds directly from NA221.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.

09 BIOMASS FUELS↗

Integrated Testing of a Membrane CO 2 Capture Process with a Coal-Fired Boiler

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy, National Energy Technology Laboratory (DOE NETL) to demonstrate integrated operation of the MTR small pilot membrane CO 2 capture system with Babcock & Wilcox Enterprises, Inc.’s (B&W) Small Boiler Simulator-II (SBS-II) pilot coal boiler (award number DE-FE0026414). The work was performed from July 1, 2015 through March 31, 2018. The overall goal of this project was to operate the existing MTR small pilot membrane CO 2 capture system at an appropriately-sized coal-fired boiler to test integrated operation with CO 2 recycle to the boiler. MTR was assisted in this project by B&W, which hosted the integrated membrane-boiler field test at the B&W Research Facility in Barberton, OH. This report details the work performed to prepare the B&W site, modify the existing MTR membrane system, install the MTR system at B&W, and operate an integrated membrane-boiler field test with CO 2 recycle to the boiler. Detailed analysis of the integrated membrane-boiler test data was conducted to validate prior B&W computational fluid dynamics (CFD) modeling and SBS-II boiler tests with CO 2 -laden air that showed modest effects of recycled CO 2 on boiler performance. The integrated test results also demonstrated how various membrane parameters impact the performance of a dynamic boiler system. Key results for all tasks and recommendations for future research are discussed in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Payload Production for the Fire Testing of Primary Containment Vessels

One safety concern for the storage of nuclear or hazardous materials within the Department of Energy (DOE) complex is the pressure response behaviors of Primary Containment Vessels (PCVs) of a 9975 shipping package. Although there are many conservative estimates for the pressure response behavior of PCV in high temperature environments, these estimations remain unchecked by experiment. Conservative estimates frequently build in large safety margins which result in a reduced operating range and potentially unnecessary operation restrictions. In an attempt to alleviate some of these barriers, Nuclear & Criticality Safety Engineering (N&CSE) has requested the fire testing of primary containment vessels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phenolic compounds and black carbon feedback controls on peat decomposition and carbon accumulation in southeastern peatlands under regimes of seasonal drought, drainage and frequent fire

Peatlands store one-third of soil C in terrestrial ecosystems and have persisted through changing climate over millennia from the arctic to the tropics. Approximately one-third of peat stores are found in subtropical and tropical peatlands (STPs) formed from high-lignin woody biomass. In this project, our questions are: 1) why do these non-sphagnum peatlands (STPs) accumulate C under warmer-drier climates and 2) how might insights coming from studying control mechanisms in STPs improve the management and conservation of the vast C stores in boreal peatlands subject to increasing climate forcing. We hypothesized that a dual control or “latch mechanism” reduces decomposition in shrub/tree communities in STPs due to both (1) higher production of polyphenol and aromatic compounds in STPs than found in northern Sphagnum/Carex communities and (2) the buildup of recalcitrant organic matter produced by light fire-drought-warming-adapted communities, together leading to a reduction in the microbial decay rate of peat. After three-years of intensive biological and chemical analysis in a series of field and microcosm experiments along our north to south bog gradient from Minnesota to Peru, we show how previously unrecognized biotic factors, particularly dynamic interlinked above- and belowground attributes control C sequestration in peatlands. Our key findings include (1) phenolics-bridged plant-microbe symbioses, principally slow-growing microbes dominated in higher phenolic wooded STPs, preserving C in peatlands under climate change, 2) phenolics are the overarching factor controlling the relative abundance of slow-and fast-growing microbes, the slow-growing microbes in STPs metabolize C slowly and are inherently resistant to disturbance, 3) global data analysis shows that soil respiration does not increase exponentially from boreal to tropical peatlands, suggesting that slow-growing microbes may have become dominant in most non-boreal peatlands, 4) peat chemistry analysis from over 2000 samples show that across peatlands both from the arctic to tropics and from high to low elevation peatlands recalcitrance increases as aromatic content increases, and 5) peat affected by low-severity wildfires displays a similar pattern of higher aromatic content. Our findings all demonstrate links between peat recalcitrance and increased content of phenolics and other aromatic compounds in plants. Thus, linked plant–microbe symbiotic traits are a key to understanding ecological resilience and resistance developed in peatlands under disturbance. New trait-based approaches that can better link above-and below ground processes are needed to advance both the accuracy and precision of current abiotic-factor-based Earth system models in predicting future soil C responses to climate-change feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Performance and Cost Assessment of a Coal Gasification Power Plant Integrated with a Direct-Fired sCO 2 Brayton Cycle

The objective of this study is to develop a cost and performance baseline for a coal syngas-fueled, direct-fired supercritical carbon dioxide (sCO2) power plant using coal gasification, and to analyze the sensitivity of its cost and performance to variations in operating parameter and cost assumptions. The study results yield a sCO2 baseline plant efficiency of 37.7% (HHV), with 97.6% carbon capture at 99.8% purity, much higher than the reference integrated gasification combined cycle (IGCC) plant using the same Shell gasifier (31.2% efficiency, 90% carbon capture). The economic analysis estimates a cost of electricity (COE) of $137/MWh for the mature, commercial-scale sCO2 plant (without CO2 transport and storage costs), yielding a 10% reduction in COE from the reference IGCC case. These results demonstrate the significant potential of direct sCO2 power cycles for achieving DOE’s transformational power generation goals for coal-fueled power plants with carbon capture and storage.

20 FOSSIL-FUELED POWER PLANTS↗

ThermoLift – A Natural Gas Fired Air Conditioner and Heat Pump

ThermoLift is developing TC-Cycle™, a natural-gas driven air conditioner and cold-climate heat pump that can provide space heating, water heating, and air conditioning in a single device. Unlike traditional heat-pump system, the TC-Cycle system uses helium as working fluid in place of high global warming potential HFC refrigerant. The system has broad application as a combined HVAC solution and technology development throughout this program has advanced the Technology Readiness Level (TRL) from TRL-1 to TRL-5 achieved in the Gen 3.0 prototype. In August of 2013, the US Department of Energy (DOE) provided Research and Development funding through the Building Technologies Innovations Program Funding Opportunity Announcement DE-FOA-0000823. The statement of work (SOW) outlined a deliverable of testing at ORNL and a final test report prepared to include various heating cooling temperature ranges and performance analysis. Furthermore, a milestone of this effort was to analyze all test data to establish further efficiency improvements and consider optimum manufacturing methodologies to facilitate the next level improvements. ThermoLift’s Gen 3.0 gas-fired heat pump was shipped and installed into ORNL’s test facility with most of the data reported herein obtained on August 6, 2018. Uninterrupted operation demonstrated cycle Coefficient of Performance (COP) well exceeding DOE targets for cold-climate heat pumps. Furthermore, there was no degradation in capacity as inlet (ambient) temperature decreased.

03 NATURAL GAS↗

FIRE Midterm Report

The goal of the FIRE topical collaboration in nuclear theory is to determine the astrophysical conditions of the rapid neutron capture process (r process), which is responsible for the formation of heavy elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update to Regulatory Activity Impacting Coal-Fired Power Plants (Slides)

This presentation evaluates recent regulatory initiatives that could have an impact on new and existing coal-fired power plants. The relevant regulations are identified, along with possible compliance strategies. To view this document, when you open the file, click 'Read Only.'

20 FOSSIL-FUELED POWER PLANTS↗

Coal-Fired Power Plants in the United States: Examination of the Costs of Retrofitting with CO 2 Capture Technology, Revision 3

This report describes the development of a database and geographic information systems (GIS) analysis of a defined population of coal-fired power plants in the U.S. to model the cost and assist in the assessment of the feasibility of retrofitting these plants with CO 2 capture technology. In addition, an assessment of the impacts on generation, CO 2 emission, and fuel consumption should all units be brought up to the average efficiency of the top decile of efficient units by nameplate was made. This report covers data sources, methodology employed, modeling and results. An appendix containing a catalog of aerial imagery used for this analysis is available as a separate document.

20 FOSSIL-FUELED POWER PLANTS↗

Tracking New Coal Fired Plants FY2011 Q1

This presentation provides an overview of proposed new coal-fired power plants that are under consideration. It focuses on those power plant development activities achieving significant progress toward completion, in order to more accurately assess the ability of this segment of the power generation industry to support adequate electricity capacity in various regions of the U.S.

01 COAL, LIGNITE, AND PEAT↗

Industrial Boiler, Diesel Fired, Over 100 Million BTU/hr

This unit process models air emissions and heat produced by an industrial-scale diesel fired boiler, producing less than 100 million BTU/hr. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=9130EF60-DC26-45BF-BE02-DB24954EB24B

42 ENGINEERING↗