Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast Timing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Avalanche photodiode based time-of-flight mass spectrometry

This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns rise time for <200 keV ions (1−40 AMU) under proper bias voltage operations. When combined with a microchannel plate to detect start electron signals from an ultra-thin carbon foil, the APD comprises a novel TOF system that successfully operates with a <0.8 ns intrinsic timing resolution even using commercial off-the-shelf constant-fraction discriminators. By replacing conventional total-energy detectors in the TOF-Energy system, APDs offer significant power and mass savings or an anti-coincidence background rejection capability in future space instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited)

A new endoscope with optimised divertor view has been developed in order to survey and monitor the emission of specific impurities such as tungsten and the remaining carbon as well as beryllium in the tungsten divertor of JET after the implementation of the ITER-like wall in 2011. The endoscope is a prototype for testing an ITER relevant design concept based on reflective optics only. It may be subject to high neutron fluxes as expected in ITER. The operating wavelength range, from 390 nm to 2500 nm, allows the measurements of the emission of all expected impurities (W I, Be II, C I, C II, C III) with high optical transmittance ({>=}30% in the designed wavelength range) as well as high spatial resolution that is {<=}2 mm at the object plane and {<=}3 mm for the full depth of field ({+-}0.7 m). The new optical design includes options for in situ calibration of the endoscope transmittance during the experimental campaign, which allows the continuous tracing of possible transmittance degradation with time due to impurity deposition and erosion by fast neutral particles. In parallel to the new optical design, a new type of possibly ITER relevant shutter system based on pneumatic techniques has been developed and integrated into the endoscope head. The endoscope is equipped with four digital CCD cameras, each combined with two filter wheels for narrow band interference and neutral density filters. Additionally, two protection cameras in the {lambda} > 0.95 {mu}m range have been integrated in the optical design for the real time wall protection during the plasma operation of JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine-root mortality rates in a temperate forest: Estimates using radiocarbon data and numerical modeling

We used an inadvertent whole-ecosystem {sup 14}C label at a temperate forest in Oak Ridge, Tennessee, USA to develop a model (Radix1.0) of fine-root dynamics. Radix simulates two live-root pools, two dead-root pools, non-normally distributed root mortality turnover times, a stored carbon (C) pool, and seasonal growth and respiration patterns. We applied Radix to analyze measurements from two root size classes (< 0.5 and 0.5-2.0 mm diameter) and three soil-depth increments (O horizon, 0-15 cm and 30-60 cm). Predicted live-root turnover times were < 1 yr and 10 yr for short- and long-lived pools, respectively. Dead-root pools had decomposition turnover times of 2 yr and 10 yr. Realistic characterization of C flows through fine roots requires a model with two live fine-root populations, two dead fine-root pools, and root respiration. These are the first fine-root turnover time estimates that take into account respiration, storage, seasonal growth patterns, and non-normal turnover time distributions. The presence of a root population with decadal turnover times implies a lower amount of belowground net primary production used to grow fine-root tissue than is currently predicted by models with a single annual turnover pool.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of asymmetric binary glass formers. I. A dielectric and nuclear magnetic resonance spectroscopy study

Dielectric spectroscopy as well as {sup 2}H and {sup 31}P nuclear magnetic resonance spectroscopy (NMR) are applied to probe the component dynamics of the binary glass former tripropyl phosphate (TPP)/polystyrene (PS/PS-d{sub 3}) in the full concentration (c{sub TPP}) range. In addition, depolarized light scattering and differential scanning calorimetry experiments are performed. Two glass transition temperatures are found: T{sub g1}(c{sub TPP}) reflects PS dynamics and shows a monotonic plasticizer effect, while the lower T{sub g2}(c{sub TPP}) exhibits a maximum and is attributed to (faster) TPP dynamics, occurring in a slowly moving or immobilized PS matrix. Dielectric spectroscopy probing solely TPP identifies two different time scales, which are attributed to two sub-ensembles. One of them, again, shows fast TPP dynamics (α{sub 2}-process), the other (α{sub 1}-process) displays time constants identical with those of the slow PS matrix. Upon heating the α{sub 1}-fraction of TPP decreases until above some temperature T{sub c} only a single α{sub 2}-population exists. Inversely, below T{sub c} a fraction of the TPP molecules is trapped by the PS matrix. At low c{sub TPP} the α{sub 2}-relaxation does not follow frequency-temperature superposition (FTS), instead it is governed by a temperature independent distribution of activation energies leading to correlation times which follow Arrhenius laws, i.e., the α{sub 2}-relaxation resembles a secondary process. Yet, {sup 31}P NMR demonstrates that it involves isotropic reorientations of TPP molecules within a slowly moving or rigid matrix of PS. At high c{sub TPP} the super-Arrhenius temperature dependence of τ{sub 2}(T), as well as FTS are recovered, known as typical of the glass transition in neat systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive manufacturing of high explosives with inert dilution for wave shaping and detonation velocity grading

The performance of a high explosive charge is highly influenced by the detonation velocity and any inherent internal structure. Additively manufactured (AM) high explosive charges allow for a precisely engineered internal structure and the selective placement of discrete or graded volumes of a tailored material, which are unachievable by conventional means. The dilution of a solid explosive by an inert additive for detonation velocity reduction is herein evaluated for a method of material extrusion called a direct-ink-write AM, where an 1,3,5,7-tetranitro-1,3,5,7-tetrazoctane-based ultraviolet -curable energetic-binder paste explosive was diluted by the inert density mock 5-iodo-2′-deoxyuridine for use in the manufacture of multi-material explosive charges. The explosive ink was characterized for printing by rheological and particle size measurements, and the detonation velocities for 0–40 wt. % inert diluent were found to have a continuous linear reduction in detonation velocity down to 14.3% difference. A two-component 3D plane wave explosive lens with 8.038 km/s “fast” and 7.491 km/s “slow” diluted ink in an internal cone demonstrated a reduced time of breakout at the output face from 361 to 53 ns. A linearly graded “fast–slow–fast” cylinder was successfully printed and fired, showing engineered control along the length of the charge as the detonation velocity dropped from 7.851 to 6.700 km/s and then recovered to 7.241 km/s. The extreme control over the internal composition of a high explosive charge via a dual-material extruder/mixer challenges conventional manufacturing approaches and opens new avenues for engineered detonation wavefronts, high explosive charge performance, and new applications.

36 MATERIALS SCIENCE↗

DIASCoPE: Directly integrated acoustic system combined with pressure experiments—A new method for fast acoustic velocity measurements at high pressure

A novel experimental system to measure elastic wave velocities in samples in situ under extreme conditions of pressure and temperature in a multi-anvil apparatus has been installed at Beamline 6-BM-B of the Advanced Photon Source at Argonne National Laboratory. This system allows for measurement of acoustic velocities via ultrasonic interferometry, and makes use of the synchrotron beam to measure sample densities via X-ray diffraction and sample lengths using X-radiographic imaging. This system is fully integrated into the automated software controls of the beamline and is capable of collecting robust data on elastic wave travel times in less than 1 s, which is an improvement of more than one to two orders of magnitude over existing systems. Moreover, this fast data collection time has been shown to have no effect on the obtained travel time results. This allows for more careful study of time-dependent phenomena with tighter snapshots in time of processes that would otherwise be lost or averaged out in other acoustic measurement systems.

Whitaker, Matthew L.↗

Estimation of economic impacts of cellulosic biofuel production: a comparative analysis of three biofuel pathways: Economic impacts of biofuel production

The development of a cellulosic biofuel industry utilizing domestic biomass resources is expected to create opportunities for economic growth resulting from the construction and operation of new biorefineries. We applied an economic input-output model to estimate potential economic impacts, particularly gross job growth, resulting from the construction and operation of biorefineries using three different technology pathways: 1) cellulosic ethanol via biochemical conversion in Iowa, 2) renewable diesel blendstock via biological conversion in Georgia, and 3) renewable diesel and gasoline blendstock via fast pyrolysis in Mississippi. Combining direct, indirect, and induced effects, capital investment associated with the construction of a biorefinery processing 2,000 dry metric tons of biomass per day (DMT/day) could yield between 5,960 and 8,470 full-time equivalent (FTE) jobs during the construction period. Fast pyrolysis biorefineries produce the most jobs on a project level thanks to the highest capital requirement among the three pathways. Normalized for one million dollars of capital investment, the fast pyrolysis biorefineries are estimated to yield slighter more jobs (12.1 jobs) than the renewable diesel (11.8 jobs) and the cellulosic ethanol (11.6 jobs) biorefineries. While operating biorefineries is not labor-intensive, the annual operation of a 2,000 DMT/day biorefinery could support between 720 and 970 jobs when the direct, indirect, and induced effects are considered. The major factor, which results in the variations among the three pathways, is the type of biomass feedstock used for biofuels. The agriculture/forest, services, and trade industries are the primary sectors that will benefit from the ongoing operation of biorefineries.

Biofuels↗

Retrieval of temperature and humidity profiles from ground-based high-resolution infrared observations using an adaptive fast iterative algorithm

Various retrieval algorithms have been developed for retrieving temperature and water vapor profiles from Atmospheric Emitted Radiance Interferometer (AERI) observations. The physical retrieval algorithm, named AERI Optimal Estimation (AERIoe), outperforms other retrieval algorithms in many aspects except the retrieval time, which is significantly increased due to the complex radiative transfer process. The calculation of the Jacobian matrix is the most computationally intensive step of the physical retrieval algorithm. Interestingly, an analysis of the change in AERI observations' information content with respect to Jacobians revealed that the AERIoe algorithm's performance presents negligible dependence on these metrics. Thus, the Jacobian matrix could remain unchanged when the variation in the atmospheric state is small in the retrieval process to reduce the most time-consuming computation. On the basis of the above findings, a fast physical–iterative retrieval algorithm was proposed by adaptively recalculating Jacobians in keeping with the changes in the atmospheric state. Experiments with synthetic observations demonstrate that the proposed method experiences an average reduction in retrieval time by an impressive 59 % compared to the original AERIoe algorithm while achieving maximum root-mean-square errors of less than 0.95 K and 0.22 log(ppmv) for heights below 3 km for the temperature and water vapor profile, respectively. Further analyses revealed that the fast-retrieval algorithm reached an acceptable convergence rate of 98.7 %, marginally lower than AERIoe's 99.9 % convergence rate for the 826 cases used in this study.

54 ENVIRONMENTAL SCIENCES↗

TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motion model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.

60 APPLIED LIFE SCIENCES↗

Development of a simultaneous Hugoniot and temperature measurement for preheated-metal shock experiments: Melting temperatures of Ta at pressures of 100 GPa

Equations of state of metals are important issues in earth science and planetary science. A major limitation of them is the lack of experimental data for determining pressure-volume and temperature of shocked metal simultaneously. By measuring them in a single experiment, a major source of systematic error is eliminated in determining from which shock pressure release pressure originates. Hence, a non-contact fast optical method was developed and demonstrated to simultaneously measure a Hugoniot pressure-volume (P{sub H}-V{sub H}) point and interfacial temperature T{sub R} on the release of Hugoniot pressure (P{sub R}) for preheated metals up to 1000 K. Experimental details in our investigation are (i) a Ni-Cr resistance coil field placed around the metal specimen to generate a controllable and stable heating source, (ii) a fiber-optic probe with an optical lens coupling system and optical pyrometer with ns time resolution to carry out non-contact fast optical measurements for determining P{sub H}-V{sub H} and T{sub R}. The shock response of preheated tantalum (Ta) at 773 K was investigated in our work. Measured data for shock velocity versus particle velocity at an initial state of room temperature was in agreement with previous shock compression results, while the measured shock data between 248 and 307 GPa initially heated to 773 K were below the Hugoniot evaluation from its off-Hugoniot states. Obtained interfacial temperatures on release of Hugoniot pressures (100-170 GPa) were in agreement with shock-melting points at initial ambient condition and ab initio calculations of melting curve. It indicates a good consistency for shock melting data of Ta at different initial temperatures. Our combined diagnostics for Hugoniot and temperature provides an important approach for studying EOS and the temperature effect of shocked metals. In particular, our measured melting temperatures of Ta address the current controversy about the difference by more than a factor of 2 between the melting temperatures measured under shock and those measured in a laser-heated diamond anvil cell at {approx}100 GPa.

36 MATERIALS SCIENCE↗

Fast and Efficient Stochastic Optimization for Analytic Continuation

In this analytic continuation of imaginary-time quantum Monte Carlo data to extract real-frequency spectra remains a key problem in connecting theory with experiment. Here we present a fast and efficient stochastic optimization method (FESOM) as a more accessible variant of the stochastic optimization method introduced by Mishchenko et al. [Phys. Rev. B 62, 6317 (2000)], and we benchmark the resulting spectra with those obtained by the standard maximum entropy method for three representative test cases, including data taken from studies of the two-dimensional Hubbard model. Genearally, we find that our FESOM approach yields spectra similar to the maximum entropy results. In particular, while the maximum entropy method yields superior results when the quality of the data is strong, we find that FESOM is able to resolve fine structure with more detail when the quality of the data is poor. In addition, because of its stochastic nature, the method provides detailed information on the frequency-dependent uncertainty of the resulting spectra, while the maximum entropy method does so only for the spectral weight integrated over a finite frequency region. Therefore, we believe that this variant of the stochastic optimization approach provides a viable alternative to the routinely used maximum entropy method, especially for data of poor quality.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast sweeping reflectometry upgrade on Tore Supra

In order to study the temporal dynamics of turbulence, the sweep time of our reflectometry has been shortened from 20 to 2 {mu}s with 1 {mu}s dead time. Detailed technical aspects of the upgrade are given, namely, about the stability of the ramp generation, the detection setup, and the fast acquisition module. A review of studies (velocity measurement of the turbulence, modifications of the wavenumber spectrum, radial mapping of correlation time, etc.) offered by such improvements is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinal Evaluation of Myocardial Fatty Acid and Glucose Metabolism in Fasted and Nonfasted Spontaneously Hypertensive Rats Using MicroPET/CT

Using longitudinal micro positron emission tomography (microPET)/computed tomography (CT) studies, we quantified changes in myocardial metabolism and perfusion in spontaneously hypertensive rats (SHRs), a model of left ventricular hypertrophy (LVH). Fatty acid and glucose metabolism were quantified in the hearts of SHRs and Wistar-Kyoto (WKY) normotensive rats using long-chain fatty acid analog 18F-fluoro-6-thia heptadecanoic acid ( 18 F-FTHA) and glucose analog 18 F-fluorodeoxyglucose ( 18 F-FDG) under normal or fasting conditions. We also used 18 F-fluorodihydrorotenol ( 18 F-FDHROL) to investigate perfusion in their hearts without fasting. Rats were imaged at 4 or 5 times over their life cycle. Compartment modeling was used to estimate the rate constants for the radiotracers. Blood samples were obtained and analyzed for glucose and free fatty acid concentrations. SHRs demonstrated no significant difference in 18 F-FDHROL wash-in rate constant (P = .1) and distribution volume (P = .1), significantly higher 18 F-FDG myocardial influx rate constant (P = 4×10 –8 ), and significantly lower 18 F-FTHA myocardial influx rate constant (P = .007) than WKYs during the 2009-2010 study without fasting. SHRs demonstrated a significantly higher 18F-FDHROL wash-in rate constant (P = 5×10 –6 ) and distribution volume (P = 3×10 –8 ), significantly higher 18 F-FDG myocardial influx rate constant (P = 3×10 –8 ), and a higher trend of 18 F-FTHA myocardial influx rate constant (not significant, P = .1) than WKYs during the 2011–2012 study with fasting. Changes in glucose plasma concentrations were generally negatively correlated with corresponding radiotracer influx rate constant changes. The study indicates a switch from preferred fatty acid metabolism to increased glucose metabolism with hypertrophy. Increased perfusion during the 2011-2012 study may be indicative of increased aerobic metabolism in the SHR model of LVH.

59 BASIC BIOLOGICAL SCIENCES↗

Clues to the nature of SN 2009ip from photometric and spectroscopic evolution to late times

We present time series photometric and spectroscopic data for the transient SN 2009ip from the start of its outburst in 2012 September until 2013 November. These data were collected primarily with the new robotic capabilities of the Las Cumbres Observatory Global Telescope Network, a specialized facility for time domain astrophysics, and includes supporting high-resolution spectroscopy from the Southern Astrophysical Research Telescope, Kitt Peak National Observatory, and Gemini Observatory. Based on our nightly photometric monitoring, we interpret the strength and timing of fluctuations in the light curve as interactions between fast-moving ejecta and an inhomogeneous circumstellar material (CSM) produced by past eruptions of this massive luminous blue variable (LBV) star. Our time series of spectroscopy in 2012 reveals that, as the continuum and narrow Hα flux from CSM interactions declines, the broad component of Hα persists with supernova (SN)-like velocities that are not typically seen in LBVs or SN impostor events. At late times, we find that SN 2009ip continues to decline slowly, at ≲ 0.01 mag day{sup –1}, with small fluctuations in slope similar to Type IIn supernovae (SNe IIn) or SN impostors but no further LBV-like activity. The late-time spectrum features broad calcium lines similar to both late-time SNe and SN impostors. In general, we find that the photometric and spectroscopic evolution of SN 2009ip is more similar to SNe IIn than either continued eruptions of an LBV star or SN impostors but we cannot rule out a nonterminal explosion. In this context, we discuss the implications for episodic mass loss during the late stages of massive star evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Model Development and Loads Analysis of an Offshore Wind Turbine on a Tension Leg Platform with a Comparison to Other Floating Turbine Concepts: April 2009

This report presents results of the analysis of a 5-MW wind turbine located on a floating offshore tension leg platform (TLP) that was conducted using the fully coupled time-domain aero-hydro-servo-elastic design code FAST with AeroDyn and HydroDyn. The report also provides a description of the development process of the TLP model. The model has been verified via comparisons to frequency-domain calculations. Important differences have been identified between the frequency-domain and time-domain simulations, and have generated implications for the conceptual design process. An extensive loads and stability analysis for ultimate and fatigue loads according to the procedure of the IEC 61400-3 offshore wind turbine design standard was performed with the verified TLP model. This report compares the loads for the wind turbine on the TLP to those of an equivalent land-based turbine. Major instabilities for the TLP are identified and described.

17 WIND ENERGY↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure and Electronic Configurations of the Intermediates of Water Oxidation in Blue Ruthenium Dimer Catalysis

Catalytic O{sub 2} evolution with cis,cis-[(bpy){sub 2}(H{sub 2}O)Ru{sup III}ORu{sup III}(OH{sub 2})(bpy){sub 2}]{sup 4+} (bpy is 2,2-bipyridine), the so-called blue dimer, the first designed water oxidation catalyst, was monitored by UV-vis, EPR, and X-ray absorption spectroscopy (XAS) with ms time resolution. Two processes were identified, one of which occurs on a time scale of 100 ms to a few seconds and results in oxidation of the catalyst with the formation of an intermediate, here termed [3,4]'. A slower process occurring on the time scale of minutes results in the decay of this intermediate and O{sub 2} evolution. Spectroscopic data suggest that within the fast process there is a short-lived transient intermediate, which is a precursor of [3,4]'. When excess oxidant was used, a highly oxidized form of the blue dimer [4,5] was spectroscopically resolved within the time frame of the fast process. Its structure and electronic state were confirmed by EPR and XAS. As reported earlier, the [3,4]' intermediate likely results from reaction of [4,5] with water. While it is generated under strongly oxidizing conditions, it does not display oxidation of the Ru centers past [3,4] according to EPR and XAS. EXAFS analysis demonstrates a considerably modified ligand environment in [3,4]'. Raman measurements confirmed the presence of the O-O fragment by detecting a new vibration band in [3,4]' that undergoes a 46 cm{sup -1} shift to lower energy upon {sup 16}O/{sup 18}O exchange. Under the conditions of the experiment at pH 1, the [3,4]' intermediate is the catalytic steady state form of the blue dimer catalyst, suggesting that its oxidation is the rate-limiting step.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗