Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-F-T-08: Brachytherapy Film Dosimetry in a Water Phantom for a Ring and Tandem HDR Applicator

Purpose: The feasibility of dose measurement using new generation EBT3 film was explored in a water phantom for a ring and tandem HDR applicator for measurements tracking mucosal dose during cervical brachytherapy. Methods: An experimental fixture was assembled to position the applicator in a water phantom. Prior to measurement, calibration curves for EBT3 film in water and in solidwater were verified. EBT3 film was placed at different known locations around the applicator in the water tank. A CT scan of the phantom with applicator was performed using clinical protocol. A typical cervical cancer treatment plan was then generated by Oncentra brachytherapy planning system. A dose of 500 cGy was prescribed to point A (2 cm, 2 cm). Locations measured by film included the outer surface of the ring, measurement point A-m (2.2 cm, 2.2 cm), and profiles extending from point A-m parallel to the tandem. Three independent measurements were conducted. The doses recorded by film were carefully analyzed and compared with values calculated by the treatment planning system. Results: Assessment of the EBT3 films indicate that the dose at point A matches the values predicted by the planning system. Dose to the point A-m was 411.5 cGy, and the outer circumferential surface dose of the ring was between 500 and 1150 cGy. It was found that from the point A-m, the dose drops 60% within 4.5 cm on the line parallel to the tandem. The measurement doses agree with the treatment planning system. Conclusion: Use of EBT3 film is feasible for in-water measurements for brachytherapy. A carefully machined apparatus will likely improve measurement accuracy. In a typical plan, our study found that the ring surface dose can be 2.5 times larger than the point A prescription dose. EBT3 film can be used to monitor mucosal dose in brachytherapy treatments.

60 APPLIED LIFE SCIENCES↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-09: Relationship Between B0 and the Contrast-To-Noise Ratio (CNR) of Tumour to Background for MRI/Radiotherapy Hybrids

Purpose: To investigate the relationship in MRI between B{sub 0} and the contrast-to-noise ratio (CNR) of various tumour/normal tissue pairs. This study is motivated by the current interest in MRI/radiotherapy hybrids, for which multiple magnetic field strengths have been proposed. CNR is the single most important parameter governing the ability of a system to identify a tumour in real time for treatment guidance. The MRI community has long since recognized that the SNR of a well-designed MR system is roughly proportional to B{sub 0}, the polarizing magnetic field. However, the CNR between two tissues is much more complicated - dependent not only on this signal behavior, but also on the different relaxation properties of the tissues. Methods: Experimentally-based models of B{sub 0}-dependant relaxation for various tumour and normal tissues from the literature were used in conjunction with signal equations for MR sequences suitable for rapid realtime imaging to develop field-dependent predictions for CNR. These CNR models were developed for liver, lung, breast, glioma, and kidney tumours for spoiled-gradient echo (SGE) and balanced steady-state free precession (bSSFP) sequences. Results: In all cases there was an improved CNR at lower fields compared to linear dependency. Further, in some tumour sites, the CNR at lower fields was found to be comparable to, or sometimes higher than those at higher fields (i.e. bSSFP CNR for glioma, kidney and liver tumours). Conclusion: Due to the variation of tissue relaxation parameters with field, lower B{sub 0} fields have been shown to perform as well or better (in terms of CNR) than higher fields for some tumour sites. In other sites this effect was less pronounced. It is the complex relationship between CNR and B{sub 0} that leads to greater CNR at 0.5 T for certain tumour types studied here for fast imaging. B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-09: Optimization of the Design of a Moving Blocker for Cone-Beam CT Scatter Correction: Experimental Evaluation

Purpose: A moving blocker based strategy has shown promising results for scatter correction in cone-beam computed tomography (CBCT). Different geometry designs and moving speeds of the blocker affect its performance in image reconstruction accuracy. The goal of this work is to optimize the geometric design and moving speed of the moving blocker system through experimental evaluations. Methods: An Elekta Synergy XVI system and an anthropomorphic pelvis phantom CIRS 801-P were used for our experiment. A blocker consisting of lead strips was inserted between the x-ray source and the phantom moving back and forth along rotation axis to measure the scatter signal. Accoriding to our Monte Carlo simulation results, three blockers were used, which have the same lead strip width 3.2mm and different gap between neighboring lead strips, 3.2, 6.4 and 9.6mm. For each blocker, three moving speeds were evaluated, 10, 20 and 30 pixels per projection (on the detector plane). Scatter signal in the unblocked region was estimated by cubic B-spline based interpolation from the blocked region. CBCT image was reconstructed by a total variation (TV) based algebraic iterative reconstruction (ART) algorithm from the partially blocked projection data. Reconstruction accuracy in each condition is quantified as CT number error of region of interest (ROI) by comparing to a CBCT reconstructed image from analytically simulated unblocked and scatter free projection data. Results: Highest reconstruction accuracy is achieved when the blocker width is 3.2 mm, the gap between neighboring lead strips is 9.6 mm and the moving speed is 20 pixels per projection. RMSE of the CT number of ROIs can be reduced from 436 to 27. Conclusions: Image reconstruction accuracy is greatly affected by the geometry design of the blocker. The moving speed does not have a very strong effect on reconstruction result if it is over 20 pixels per projection.

60 APPLIED LIFE SCIENCES↗

Automatic segmentation of the glenohumeral cartilages from magnetic resonance images

Purpose: Magnetic resonance (MR) imaging plays a key role in investigating early degenerative disorders and traumatic injuries of the glenohumeral cartilages. Subtle morphometric and biochemical changes of potential relevance to clinical diagnosis, treatment planning, and evaluation can be assessed from measurements derived from in vivo MR segmentation of the cartilages. However, segmentation of the glenohumeral cartilages, using approaches spanning manual to automated methods, is technically challenging, due to their thin, curved structure and overlapping intensities of surrounding tissues. Automatic segmentation of the glenohumeral cartilages from MR imaging is not at the same level compared to the weight-bearing knee and hip joint cartilages despite the potential applications with respect to clinical investigation of shoulder disorders. In this work, the authors present a fully automated segmentation method for the glenohumeral cartilages using MR images of healthy shoulders. Methods: The method involves automated segmentation of the humerus and scapula bones using 3D active shape models, the extraction of the expected bone–cartilage interface, and cartilage segmentation using a graph-based method. The cartilage segmentation uses localization, patient specific tissue estimation, and a model of the cartilage thickness variation. The accuracy of this method was experimentally validated using a leave-one-out scheme on a database of MR images acquired from 44 asymptomatic subjects with a true fast imaging with steady state precession sequence on a 3 T scanner (Siemens Trio) using a dedicated shoulder coil. The automated results were compared to manual segmentations from two experts (an experienced radiographer and an experienced musculoskeletal anatomist) using the Dice similarity coefficient (DSC) and mean absolute surface distance (MASD) metrics. Results: Accurate and precise bone segmentations were achieved with mean DSC of 0.98 and 0.93 for the humeral head and glenoid fossa, respectively. Mean DSC scores of 0.74 and 0.72 were obtained for the humeral and glenoid cartilage volumes, respectively. The manual interobserver reliability evaluated by DSC was 0.80 ± 0.03 and 0.76 ± 0.04 for the two cartilages, implying that the automated results were within an acceptable 10% difference. The MASD between the automatic and the corresponding manual cartilage segmentations was less than 0.4 mm (previous studies reported mean cartilage thickness of 1.3 mm). Conclusions: This work shows the feasibility of volumetric segmentation and separation of the glenohumeral cartilages from MR images. To their knowledge, this is the first fully automated algorithm for volumetric segmentation of the individual glenohumeral cartilages from MR images. The approach was validated against manual segmentations from experienced analysts. In future work, the approach will be validated on imaging datasets acquired with various MR contrasts in patients.

60 APPLIED LIFE SCIENCES↗

RNAseq analysis of Cellvibrio japonicus during starch utilization differentiates between genes encoding carbohydrate active enzymes controlled by substrate detection or growth rate

ABSTRACT Bacterial utilization of starch is increasingly of interest as the importance and contributions of animal gut microbiomes become more defined. Consequently, identifying and characterizing the bacterial enzymes responsible for the degradation, transport, and metabolism of starch will enable developments in pharmaceutical, biotechnological, and culinary industries searching for novel prebiotics, carrier molecules, and low glycemic index sweeteners. The current challenge is that bacteria proficient at starch utilization often have hundreds of carbohydrate active enzymes, and it is unclear which are essential for starch utilization using only homology-based bioinformatics or computational methods. Complementary experimental data are also needed, especially to understand the regulation of bacterial starch utilization. We have completed an RNAseq analysis of the Gram-negative bacterium Cellvibrio japonicus and found that it has sophisticated regulation that includes substrate sensing and growth rate components for genes that encode starch-degrading enzymes. Among the 22 genes predicted to encode starch-active enzymes, C. japonicus has 10 alpha-amylases, 4 alpha-glucosidases, 2 pullulnases, and 2 cyclomaltodextrin glucanotransferases, 15 of which were up-regulated during exponential growth on starch and 8 up-regulated in stationary phase. Growth analyses with an enzyme secretion deficient mutant of C. japonicus suggested that secreted amylases are essential for this bacterium to degrade starch. Our approach of coupling a physiological growth assay with transcriptomic data provides a platform to identify targets for further genetic or biochemical analysis that can be broadly applied to other starch-utilizing bacteria. IMPORTANCE Understanding the bacterial metabolism of starch is important as this polysaccharide is a ubiquitous ingredient in foods, supplements, and medicines, all of which influence gut microbiome composition and health. Our RNAseq and growth data set provides a valuable resource to those who want to better understand the regulation of starch utilization in Gram-negative bacteria. These data are also useful as they provide an example of how to approach studying a starch-utilizing bacterium that has many putative amylases by coupling transcriptomic data with growth assays to overcome the potential challenges of functional redundancy. The RNAseq data can also be used as a part of larger meta-analyses to compare how C. japonicus regulates carbohydrate active enzymes, or how this bacterium compares to gut microbiome constituents in terms of starch utilization potential.

59 BASIC BIOLOGICAL SCIENCES↗

Small-angle scattering study of Aspergillus awamori glycoprotein glucoamylase

Glucoamylase from fungus Aspergillus awamori is glycoside hydrolase that catalyzes the hydrolysis of α-1,4- and α-1,6-glucosidic bonds in glucose polymers and oligomers. This glycoprotein consists of a catalytic domain and a starch-binding domain connected by an O-glycosylated polypeptide chain. The conformation of the linker, the relative arrangement of the domains, and the structure of the full-length enzyme are unknown. The structure of the recombinant glucoamylase GA1 was studied by molecular modelling and small-angle neutron scattering (SANS) methods. The experimental SANS data provide evidence that glucoamylase exists as a monomer in solution and contains a glycoside component, which makes a substantial contribution to the scattering. The model of full-length glucoamylase, which was calculated without taking into account the effect of glycosylation, is consistent with the experimental data and has a radius of gyration of 33.4 ± 0.6 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Ginzburg-Landau functional calculations of the structure and energy of the coherent interphase boundaries between austenite and martensite in iron

The earlier-developed methods and experimental data on the phonon spectra and thermodynamics of fcc and bcc iron are used to construct a generalized Ginzburg-Landau functional for microscopic investigations of the austenite-martensite phase transformations in iron. This functional is used to calculate the structure and properties of a plane austenite-martensite interface for arbitrary orientations of this interface at various temperatures. The transformation parameter profiles in the interface region are calculated. The interface width is found to substantially exceed the interatomic distances. The interfacial surface energy is 500-800 erg/cm{sup 2}, depends strongly on the orientation, and has a sharp maximum when the interface is parallel to a close-packed plane.

36 MATERIALS SCIENCE↗

Recoil studies in the reaction of {sup 12}C ions with the enriched isotope {sup 118}Sn

The recoil properties of the product nuclei from the interaction of 2.2 GeV/nucleon {sup 12}C ions from Nuclotron of the Laboratory of High Energies, Joint Institute for Nuclear Research at Dubna with a {sup 118}Sn target have been studied via catcher foils method. The experimental data were analyzed using the mathematical formalism of the standard two-step vector model. The results for {sup 12}C ions are compared with those for deuterons and protons. Three different Los Alamos versions of the Quark-Gluon String Model were used for comparison with our experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliability of Photonuclear Data: Various Experiments and Evaluations

The well-known problem of reliability of partial photoneutron cross-section data obtained using beams of quasimonoenergetic annihilation photons was discussed. Noticeable disagreements between data from various experiments were analyzed using physical data reliability criteria. The experimentally-theoretical method for evaluating of reaction cross sections satisfied physical criteria was used and new reliable data were obtained for many nuclei. The disagreements between newly evaluated cross sections and data from the IAEA Digital Photonuclear Data Library were discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small-Angle Neutron Scattering Wave Interference on Ferromagnetic Alloys

The detection conditions and features of direct and scattered neutron wave interference are studied on magnetized Co{sub 67}Fe{sub 31}V{sub 2} alloy slabs. The angular intensity distributions of neutrons passed through a sample are measured for the opposite polarization directions of the initial neutron beam. The sought-for effect that is induced by the magnetic scattering on crystal structure irregularities in specimens manifest itself by different areas of peaks “without neutron spin flip.” The ratio of these areas depends on the thermal treatment mode, sample thickness and strength of the magnetic field applied to the sample. The peaks “with neutron spin flip” are due to the mechanism of neutron wave passage through magnetononcollinear boundaries. The methods for experimental data acquisition and processing are reported as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiscale Neural Networks for Approximating Green’s Functions

Neural networks (NNs) have been widely used to solve partial differential equations (PDEs) in the applications of physics, biology, and engineering. One effective approach for solving PDEs with a fixed differential operator is learning Green’s functions. However, Green’s functions are notoriously difficult to learn due to their poor regularity, which typically requires larger NNs and longer training times. In this work, we address these challenges by leveraging multiscale NNs to learn Green’s functions. Through theoretical analysis using multiscale Barron space methods and experimental validation, we show that the multiscale approach significantly reduces the necessary NN size and accelerates training.

97 MATHEMATICS AND COMPUTING↗

Alternative analysis of the MINERVE ZPR oscillation experiments

Delayed neutrons are of fundamental importance in the field of nuclear reactor dynamics and control. However, the precursor yield fraction for a given nuclear reactor are dependent on the properties of the reactor. Thus, in-pile experiments, such as oscillation experiments are conducted in order to measure those values. In this work, an alternative analysis of the piston oscillation experiments that have been conducted in the MINERVE reactor in 2013 is performed. A new method which evolves effective terms that cancel out undesired drifts of the flux during the experiments is presented. The evaluation of the uncertainty on the values of the response function is also presented. Moreover, the effective delayed neutron fraction β{sub eff} is evaluated and is compared to results in previous works. As the analysis has led to an estimation of β{sub eff} with a large uncertainty, it has been deduced that the oscillation experiments that have been conducted in MINERVE are not a reliable method of experimentation to determine the value of β{sub eff} in the reactor and that the noise experiments are better suited for that purpose.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power enhancement of burst-mode UV pulses using a doubly-resonant optical cavity

We report a doubly-resonant enhancement cavity (DREC) that can realize a simultaneous enhancement of two incoming laser beams at different wavelengths and different temporal structures. The double-resonance condition is theoretically analyzed and different DREC locking methods are experimentally investigated. Simultaneous locking of a Fabry-Perot cavity to both an infrared (IR, 1064 nm) and its frequency tripled ultraviolet (UV, 355 nm) pulses has been demonstrated by controlling the frequency difference between the two beams with a fiber optic frequency shifter. The DREC technique opens a new paradigm in the applications of optical cavities to power enhancement of burst-mode lasers with arbitrary macropulse width and repetition rate.

42 ENGINEERING↗

A Protein Turnover Signaling Motif Controls the Stimulus-Sensitivity of Stress Response Pathways

Stimulus-induced perturbations from the steady state are a hallmark of signal transduction. In some signaling modules, the steady state is characterized by rapid synthesis and degradation of signaling proteins. Conspicuous among these are the p53 tumor suppressor, its negative regulator Mdm2, and the negative feedback regulator of NFkB, IkBa. We investigated the physiological importance of this turnover, or flux, using a computational method that allows flux to be systematically altered independently of the steady state protein abundances. Applying our method to a prototypical signaling module, we show that flux can precisely control the dynamic response to perturbation. Next, we applied our method to experimentally validated models of p53 and NFkB signaling. We find that high p53 flux is required for oscillations in response to a saturating dose of ionizing radiation (IR). In contrast, high flux of Mdm2 is not required for oscillations but preserves p53 sensitivity to sub-saturating doses of IR. In the NFkB system, degradation of NFkB-bound IkB by the IkB kinase (IKK) is required for activation in response to TNF, while high IKK-independent degradation prevents spurious activation in response to metabolic stress or low doses of TNF. Our work identifies flux pairs with opposing functional effects as a signaling motif that controls the stimulus-sensitivity of the p53 and NFkB stress-response pathways, and may constitute a general design principle in signaling pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization of Nano-Carbon Materials for Hydrogen Sorption

Research undertaken has added to the understanding of several critical areas, by providing both negative answers (and therefore eliminating expensive further studies of unfeasible paths) and positive feasible options for storage. Theoretical evaluation of the early hypothesis of storage on pure carbon single wall nanotubes (SWNT) has been scrutinized with the use of comprehensive computational methods (and experimental tests by the Center partners), and demonstrated that the fundamentally weak binding energy of hydrogen is not sufficiently enhanced by the SWNT curvature or even defects, which renders carbon nanotubes not practical media. More promising direction taken was towards 3-dimensional architectures of high porosity where concurrent attraction of H2 molecule to surrounding walls of nano-scale cavities can double or even triple the binding energy and therefore make hydrogen storage feasible even at ambient or somewhat lower temperatures. An efficient computational tool has been developed for the rapid capacity assessment combining (i) carbon-foam structure generation, (ii) accurate empirical force fields, with quantum corrections for the lightweight H2, and (iii) grand canonical Monte Carlo simulation. This made it possible to suggest optimal designs for carbon nanofoams, obtainable via welding techniques from SWNT or by growth on template-zeolites. As a precursor for 3D-foams, we have investigated experimentally the synthesis of VANTA (Vertically Aligned NanoTube Arrays). This can be used for producing nano-foams. On the other hand, fluorination of VANTA did not show promising increase of hydrogen sorption in several tests and may require further investigation and improvements. Another significant result of this project was in developing a fundamental understanding of the elements of hydrogen spillover mechanisms. The benefit of developed models is the ability to foresee possible directions for further improvement of the spillover mechanism.

08 HYDROGEN↗

Electrolytes at Solid-Water Interfaces: Theoretical Studies for Practical Applications

The goal of this research program was to determine how a solid substrate affects structure and dynamics of aqueous electrolyte solutions. From fundamental observations, we seek to improve practical applications. Of particular interest at the project inset were carbon nanotube separation, electric double layer capacitors, and water desalination. As time progresses, we became interested in sub-surface water transport and fate, and in hydraulic fracturing. We employed an arsenal of techniques based on atomistic molecular dynamics simulations. We validated our methods using experimental data, to propose practical improvements. Some experiments were conducted in house. We established valuable collaborations with experienced scientists at National Laboratories to provide information not attainable with our in-house resources.

25 ENERGY STORAGE↗

A feasibility and optimization study to determine cooling time and burnup of advanced test reactor fuels using a nondestructive technique

The goal of this study presented is to determine the best available non-destructive technique necessary to collect validation data as well as to determine burn-up and cooling time of the fuel elements onsite at the Advanced Test Reactor (ATR) canal. This study makes a recommendation of the viability of implementing a permanent fuel scanning system at the ATR canal and leads3 to the full design of a permanent fuel scan system. The study consisted at first in determining if it was possible and which equipment was necessary to collect useful spectra from ATR fuel elements at the canal adjacent to the reactor. Once it was establish that useful spectra can be obtained at the ATR canal the next step was to determine which detector and which configuration was better suited to predict burnup and cooling time of fuel elements non-destructively. Three different detectors of High Purity Germanium (HPGe), Lanthanum Bromide (LaBr3), and High Pressure Xenon (HPXe) in two system configurations of above and below the water pool were used during the study. The data collected and analyzed was used to create burnup and cooling time calibration prediction curves for ATR fuel. The next stage of the study was to determine which of the three detectors tested was better suited for the permanent system. From spectra taken and the calibration curves obtained, it was determined that although the HPGe detector yielded better results, a detector that could better withstand the harsh environment of the ATR canal was needed. The in-situ nature of the measurements required a rugged fuel scanning system, low in maintenance and easy to control system. Based on the ATR canal feasibility measurements and calibration results it was determined that the LaBr3 detector was the best alternative for canal in-situ measurements; however in order to enhance the quality of the spectra collected using this scintillator a deconvolution method was developed. Following the development of the deconvolution method for ATR applications the technique was tested using one-isotope, multi-isotope and fuel simulated sources. Burnup calibrations were perfomed using convoluted and deconvoluted data. The calibrations results showed burnup prediction by this method improves using deconvolution. The final stage of the deconvolution method development was to perform an irradiation experiment in order to create a surrogate fuel source to test the deconvolution method using experimental data. A conceptual design of the fuel scan system is path forward using the rugged LaBr3 detector in an above the water configuration and deconvolution algorithms.

07 ISOTOPE AND RADIATION SOURCES↗