Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Vegetation Greening Mitigates the Impacts of Increasing Extreme Rainfall on Runoff Events

Future flood risk assessment has primarily focused on heavy rainfall as the main driver, with the assumption that projected increases in extreme rain events will lead to subsequent flooding. However, the presence of and changes in vegetation have long been known to influence the relationship between rainfall and runoff. Here, we extract historical (1850–1880) and projected (2070–2100) daily extreme rainfall events, the corresponding runoff, and antecedent conditions simulated in a prominent large Earth system model ensemble to examine the shifting extreme rainfall and runoff relationship. Even with widespread projected increases in the magnitude (78% of the land surface) and number (72%) of extreme rainfall events, we find projected declines in event-based runoff ratio (runoff/rainfall) for a majority (57%) of the Earth surface. Runoff ratio declines are linked with decreases in antecedent soil water driven by greater transpiration and canopy evaporation (both linked to vegetation greening) compared to areas with runoff ratio increases. Using a machine learning regression tree approach, we find that changes in canopy evaporation is the most important variable related to changes in antecedent soil water content in areas of decreased runoff ratios (with minimal changes in antecedent rainfall) while antecedent ground evaporation is the most important variable in areas of increased runoff ratios. Our results suggest that simulated interactions between vegetation greening, increasing evaporative demand, and antecedent soil drying are projected to diminish runoff associated with extreme rainfall events, with important implications for society.

soil moisture↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗

Organic flash cycles for efficient power production

This disclosure provides systems, methods, and apparatus related to an Organic Flash Cycle (OFC). In one aspect, a modified OFC system includes a pump, a heat exchanger, a flash evaporator, a high pressure turbine, a throttling valve, a mixer, a low pressure turbine, and a condenser. The heat exchanger is coupled to an outlet of the pump. The flash evaporator is coupled to an outlet of the heat exchanger. The high pressure turbine is coupled to a vapor outlet of the flash evaporator. The throttling valve is coupled to a liquid outlet of the flash evaporator. The mixer is coupled to an outlet of the throttling valve and to an outlet of the high pressure turbine. The low pressure turbine is coupled to an outlet of the mixer. The condenser is coupled to an outlet of the low pressure turbine and to an inlet of the pump.

30 DIRECT ENERGY CONVERSION↗

Fault detection and diagnosis for refrigerator from compressor sensor

A refrigerator, a sealed refrigerant system, and method are provided where the refrigerator includes at least a refrigerated compartment and a sealed refrigerant system including an evaporator, a compressor, a condenser, a controller, an evaporator fan, and a condenser fan. The method includes monitoring a frequency of the compressor, and identifying a fault condition in the at least one component of the refrigerant sealed system in response to the compressor frequency. The method may further comprise calculating a compressor frequency rate based upon the rate of change of the compressor frequency, wherein a fault in the condenser fan is identified if the compressor frequency rate is positive and exceeds a condenser fan fault threshold rate, and wherein a fault in the evaporator fan is identified if the compressor frequency rate is negative and exceeds an evaporator fan fault threshold rate.

42 ENGINEERING↗

Fault detection and diagnosis for refrigerator from compressor sensor

A refrigerator, a sealed refrigerant system, and method are provided where the refrigerator includes at least a refrigerated compartment and a sealed refrigerant system including an evaporator, a compressor, a condenser, a controller, an evaporator fan, and a condenser fan. The method includes monitoring a frequency of the compressor, and identifying a fault condition in the at least one component of the refrigerant sealed system in response to the compressor frequency. The method may further comprise calculating a compressor frequency rate based upon the rate of change of the compressor frequency, wherein a fault in the condenser fan is identified if the compressor frequency rate is positive and exceeds a condenser fan fault threshold rate, and wherein a fault in the evaporator fan is identified if the compressor frequency rate is negative and exceeds an evaporator fan fault threshold rate.

42 ENGINEERING↗

Evaluation and Impacts of Mercury in the SRS Liquid Waste System - 16121

The Savannah River Site (SRS) Liquid Waste System (LWS) stores radioactive waste in 43 underground tanks. The radionuclides in the waste are removed through a series of separation processes and the low-level fraction is immobilized in a grout waste form while the high level fraction is disposed in a glass waste form. Mercury originated from decades of canyon processing (used as a catalyst for dissolving the aluminum cladding of reactor fuel) and is present throughout the LWS (∼60 metric tons). Mercury has long been a consideration in the LWS, from both hazard and processing perspectives. Mercury is removed from the LWS in many ways including: 1) the Tank Farm evaporator condensates; 2) at the Defense Waste Processing Facility (DWPF) where it is steam-stripped and removed during the feed preparation processes; 3) it is removed at the Effluent Treatment Plant (ETP); and it is immobilized in the low-level, grout waste form. An integrated, system-wide evaluation and assessment of mercury behavior in the LWS is being performed. The recently completed Phase I evaluation focused on mercury inventory and speciation in the LWS; mercury holdup and chemical processing behavior; mercury impact Identification, including worker safety and equipment degradation; and mercury removal and disposal options. The mercury removal system at the DWPF has been unable to remove mercury successfully due to equipment and chemistry challenges since the 2008 timeframe. Phase I evaluations indicate that approximately 43 percent of the mercury in waste sent to the DWPF is now returning to the Tank Farm in the recycle stream and is concentrating to higher than expected levels (∼500 mg/l) around the 2H evaporator system. The chemical behavior of mercury is further complicated by the formation of higher than expected quantities of organomercury species, specifically methyl mercury, now present in the DWPF recycle evaporator system (2H Tank farm evaporator), which is used to volume-reduce the recycle stream. Phase II activities are building on the Phase I mercury activities, including additional sampling and characterization activities, a re-assessment of overall system knowledge, ranking and prioritizing critical gaps/information in mercury behavior across the flowsheet, assessing impacts of mercury removal and disposal options, and documenting an action plan for overall mercury management in the LWS. Phase II activities include two System Engineering Evaluations to 1) 'Reestablish Mercury removal Capability within DWPF', and 2) 'Determine the Best Alternative Mercury Removal Location with the LWS'. This paper provides the results of the Phase I and II mercury evaluations for the SRS LWS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Empirical prediction of saline water atomization pressure loss and spray phase change using local flow pressure analysis

A pressure analysis technique was developed to obtain spray spatial evaporation profile in a thermal desalination process. The technique can replace temperature-based evaporation measurement methods that are challenged by liquid-phase interference. It also provides an alternative to optical methods with high cost and complexity. Fundamental analysis was developed to determine local humidity ratios from changes in local static and dynamic pressures. The analysis was applied to data obtained from an external mixing air-assist atomizer. An empirical model was developed for the pressure loss in atomization process and was used in the analysis of humidity ratio. The results were used to develop empirical correlations for local humidity ratio in spray mediums using inlet conditions. Utilizing inlet conditions to predict evaporation profiles is an important contribution as it eliminates the need to take local spray measurements. Obtaining local data is often difficult and expensive; Our method and correlation circumvent the need for that. Finally, the correlations presented in this paper apply to saline water sprays with total dissolved salt of 0-10 wt%. The salinity-specific correlations are accurate to within ±10% of experimental data. The individual models were aggregated into a unified correlation for salinities within 0-10 wt%. The unified correlation is accurate to within ±18% of experimental data.

42 ENGINEERING↗

Decommissioning of a facility in a historical reactor at SRS: achieving both historical significance preservation and effective in-situ decommissioning - 15275

The Savannah River Site (SRS) is an 802 square-kilometer United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina, where Management and Operations are performed by Savannah River Nuclear Solutions, LLC (SRNS). In 2004, US DOE recognized SRS as a structure within the Cold War Historic District of national, state and local significance because it is composed of the first generation of facilities constructed and operated from 1950 through 1989 to produce plutonium and tritium for our nation's defense. US DOE agreed to manage the SRS 105-C Reactor Facility as a potentially historic property due to its significance in supporting the U.S. Cold War Mission and for potential for future interpretation. The Disassembly Basin (DB) in C Reactor was evaluated for action under CERCLA. Data indicated there were over 830 curies of radioactivity associated with the basin sediments and approximately 9.1 million (M) liters (L) of contaminated water, not including a large quantity of activated reactor equipment, scrap metal, and debris on the basin floor. The release of DB water could potentially migrate to the aquifer and contaminate groundwater. The need for an action was identified to reduce risks to personnel in the facility and to eliminate the possible release of contaminants into the environment. In-situ decommissioning was selected as the remedy. The remedial action proceeded in stages: -Above-grade modifications to the interior of DB building -Relocation of irradiated scrap and reactor components to the deepest segments of the DB - Construction of a metal building to house evaporators - Forced evaporation of the DB's radiologically contaminated water - Grouting with special hybrid grouts - Removal of the evaporators and temporary building. Since the building itself was not demolished and will remain unchanged in appearance with the exception of filling the DB with grout, this ISD removal action/methodology did not adversely impact the historical significance of the 105-C Reactor Building, in accordance with the National Historic Preservation Act, nor did it adversely affect the ability to determine the full extent and details of preservation at some later date. Both special hybrid grout materials met all requirements. Overall average 7-day compressive strength for the dry area mix was 1.54 MPa (223 psi) and for the underwater mix 2.94 MPa (427 psi).Overall 28-day compressive strength for the dry area mix was 2.88 MPa (417 psi) and for the underwater mix 4.99 MPa (724 psi). A limited amount of testing was also performed at 91 days, where the overall compressive strength for the dry area mix was found to be 9.40 MPa (1363 psi) and for the underwater mix 13.98 MPa (2028 psi). All compressive strength values far exceeded the 0.34 MPa (50 psi) minimum requirements. The special, flowable-fill grouts designed and used for P- and R-Reactor ISD and used again for this 105-C ISD removal action resulted in considerable labor, cost, and schedule savings versus conventional materials. As an added bonus/benefit, the CO{sub 2} footprint of the SRS C-Reactor DB ISD was minimized by using a small amount of cement and byproduct material to produce the structural fill materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evapotranspiration Partitioning Using Flux Tower Data in a Semi-Arid Ecosystem

Information about evapotranspiration (ET) and its components, that is, evaporation and transpiration, is crucial for a wide range of water and ecosystem management applications. However, partitioning ET into its two components is often challenging because of their spatiotemporal variabilities and lack of process understanding. This study developed a machine learning (ML) framework to shed light on ET processes and assess the relative importance of different drivers by incorporating hydrometeorology and biomass productivity variables. The Shapley Additive Explanations (SHAP) approach was applied to enhance explainability and rank the importance of ET drivers and their components. A total of 62 variables covering hydrometeorological and biomass productivity dimensions were considered from the Reynolds Creek Critical Zone Observatory (CZO) station in Idaho. The variable importance assessment identified the leading drivers individually for evaporation, transpiration and ET (soil water content for evaporation, vapour pressure deficit for transpiration and soil water content for ET). The results further highlighted the value of combining hydrometeorological and biomass productivity variables to achieve better predictability of ET processes.

54 ENVIRONMENTAL SCIENCES↗

Relationships between Cloud Droplet Spectral Relative Dispersion and Entrainment Rate and Their Impacting Factors

Cloud microphysical properties are significantly affected by entrainment and mixing processes. However, it is unclear how the entrainment rate affects the relative dispersion of cloud droplet size distribution. Previously, the relationship between relative dispersion and entrainment rate was found to be positive or negative. To reconcile the contrasting relationships, the Explicit Mixing Parcel Model is used to determine the underlying mechanisms. When evaporation is dominated by small droplets, and the entrained environmental air is further saturated during mixing, the relationship is negative. However, when the evaporation of big droplets is dominant, the relationship is positive. Whether or not the cloud condensation nuclei are considered in the entrained environmental air is a key factor as condensation on the entrained condensation nuclei is the main source of small droplets. However, if cloud condensation nuclei are not entrained, the relationship is positive. If cloud condensation nuclei are entrained, the relationship is dependent on many other factors. High vertical velocity, relative humidity of environmental air, liquid water content, and low droplet number concentration are more likely to cause the negative relationship since new saturation is easier to achieve by evaporation of small droplets. Further, the signs of the relationship are not strongly affected by the turbulence dissipation rate, but the higher dissipation rate causes the positive relationship more significant for a larger entrainment rate. A conceptual model is proposed to reconcile the contrasting relationships. This work enhances the understanding of relative dispersion and lays a foundation for the quantification of entrainment-mixing mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Hydrogeological and hydrochemical investigation of groundwater using environmental isotopes ({sup 18}O, {sup 2}H, {sup 3}H, {sup 14}C) and chemical tracers: a case study of the intermediate aquifer, Sfax, southeastern Tunisia

Major element concentrations and stable (δ{sup 18}O and δ{sup 2}H) and radiogenic ({sup 3}H and {sup 14}C) isotopes in groundwater have proved useful tracers for understanding the geochemical processes that control groundwater mineralization and for identifying recharge sources in the semi-arid region of Sfax (southeastern Tunisia). Major-ion chemical data indicate that the origins of the salinity in the groundwater are the water–rock interactions, mainly the dissolution of evaporitic minerals, as well as the cation exchange with clay minerals. The δ{sup 18}O and δ{sup 2}H relationships suggest variations in groundwater recharge mechanisms. Strong evaporation during recharge with limited rapid water infiltration is evident in the groundwater of the intermediate aquifer. The mixing with old groundwater in some areas explains the low stable isotope values of some groundwater samples. Groundwaters from the intermediate aquifer are classified into two main water types: Ca-Na-SO{sub 4} and Ca-Na-Cl-SO{sub 4}. The high nitrate concentrations suggest an anthropogenic source of nitrogen contamination caused by intensive agricultural activities in the area. The stable isotopic signatures reveal three water groups: non-evaporated waters that indicate recharge by recent infiltrated water; evaporated waters that are characterized by relatively enriched δ{sup 18}O and δ{sup 2}H contents; and mixed groundwater (old/recent) or ancient groundwater, characterized by their depleted isotopic composition. Tritium data support the existence of recent limited recharge; however, other low tritium values are indicative of pre-nuclear recharge and/or mixing between pre-nuclear and contemporaneous recharge. The carbon-14 activities indicate that the groundwaters were mostly recharged under different climatic conditions during the cooler periods of the late Pleistocene and Holocene.

58 GEOSCIENCES↗

Model Implementation of Boron Removal Using CaCl{sub 2}-CaO-SiO{sub 2} Slag System for Solar-Grade Silicon

A new CaCl{sub 2}-CaO-SiO{sub 2} slag system was recently proposed to remove boron from metallurgy-grade silicon by oxidized chlorination and evaporation. To further investigate the boron transformation process at a high temperature, a model implementation to present the transfer of boron from molten silicon to the gas phase via slag is introduced. Heat transfer, fluid flow, the chemical reactions at the interface and surface, the mass transfer and diffusion of boron in the molten silicon and slag, and the evaporation of BOCl and CaCl{sub 2} were coupled in this model. After the confirmation of the thermal field, other critical parameters, including the boron partition ratios (L{sub B}) for this slag from 1723 K to 1823 K (1450 °C to 1550 °C), the thicknesses of the velocity boundary layer at the surface and interface, the mass transfer coefficients of the boundary layer at the surface and interface, and partial pressure of BOCl in the gas phase were analyzed to determine the rate-limiting step. To verify this model implementation, boron removal experiments were carried out at various temperatures and with various initial mass ratios of slag to silicon (μ). The evaporation rate of CaCl{sub 2} was also measured by thermogravimetry analysis (TGA).

36 MATERIALS SCIENCE↗

Evapotranspiration Partitioning of Eucalyptus benthamii and Pinus taeda During Early Stand Development

Increasing demand for bioenergy from intensively managed woody crops raises concerns of increased evapotranspiration and potential decreases in water yield. Pinus taeda (loblolly pine) is currently the most cultivated species in the southeastern USA, the country’s wood basket. However, Eucalyptus species could achieve greater productivity but with unknown ramifications for water budgets. To address the knowledge gap, we determined annual water budgets of loblolly pine and Eucalyptus benthamii (eucalypt) from growing years 3 through 5 in a replicated (n = 3) two-factor design comparing species and groundwater depth. Paired plots were established across a depth-to-groundwater gradient from shallow (~ 2 m) to deep (~ 8 m). Hydrologic budgets were constructed by measuring precipitation, interception, soil evaporation, and transpiration. Eucalypt evapotranspiration and above-ground biomass production for growing years 3 through 5 were on average 25 and 14% greater than pine, respectively; however, evapotranspiration did not differ across groundwater depths. At the end of growing year 5, eucalypt had higher transpiration and evapotranspiration per unit area than pine. Soil evaporation was substantial in young plantations (nearly 500 mm) in growing year 3 but declined as the canopy closed. Partitioning of evapotranspiration components in developing bioenergy plantations was dynamic due to canopy development driven decreases in soil evaporation and increases in transpiration and interception; total evapotranspiration was less variable from year to year. Water use efficiency (WUE, kg biomass/m 3 H 2 O) per unit evapotranspiration was similar between species, but WUE per unit transpiration was higher in pine. As a result, considering total evapotranspiration in young plantations can affect WUE interpretations.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of rapid thermal annealing of copper indium aluminium gallium diselenide solar cell devices and its deposition challenges

Thin-film photovoltaic research based on ternary or quaternary absorber materials has mainly concentrated on copper (indium/gallium) diselenide, CuIn x Ga 1-x Se 2 (CIGS). This material has demonstrated exceptional energy conversion efficiencies. By altering the In/Ga ratio the band gap can be varied from 1.02 eV (for CuInSe 2 ) to 1.68 eV (for CuGaSe 2 ). However, research from leading groups showed that cells have maximum efficiency at or below 1.35 eV. This paper reports the challenges of using aluminium alloyed CIGS deposited with a single step co-evaporation method. Adding aluminium is found to reduce the bulk trap state density for wide gap devices. However, it created significant safety issues when compared to conventional CIGS co-evaporation deposition systems. The release of H 2 Se when moisture comes in contact with aluminium selenide was resolved by placing exhaust lines at various places of the deposition chamber. A single phase CIAGS device with a bandgap of 1.30 eV was prepared using a co-evaporation method. The fabricated solar cell devices with CIAGS absorber layers and resulted in a photoconversion efficiency of 10.3%. A progressive rapid thermal annealing at various temperature resulted in a 10% increase in the overall efficiency at 300 °C. The efficiencies were reduced when the RTA temperature increased above 300 °C.

14 SOLAR ENERGY↗

Modelling the interlayer bond strength of 3D printed concrete with surface moisture

Highlights: • An analytical model for interlayer adhesion of 3DPC is proposed based on the amount of surface moisture on the interlayer. • For this mix, the model accurately (RMSE=2.5%) predicts the reduction in interlayer adhesion from 30% to 50%. • Internal curing with superabsorbent polymers increases the interlayer adhesion by 10% and flexural strength by 19%. • SAPs also improve the initial thixotropy by 49% and buildability by 25% compared to the reference. Providing additional water to the hydrating cementitious particles is essential to achieve the optimal mechanical performance of the low w/b concrete mixes preferred for 3D printing. This study incorporates superabsorbent polymers (SAP) and additional water in 3D printed concrete (3DPC) to promote the hydration process through delayed internal water release. The study shows that a retentive SAP modifies the rheological development by absorbing the pore fluid for a short period after printing. The absorption-induced stiffening increases the thixotropy and buildability by 49% and 25%, respectively. A retentive SAP increases the flexural strength and interlayer adhesion by 19% and 10%, respectively. This is due to the internal water release that promotes hydration. Evaporation of the interlayer moisture during the pass time has the opposite effect— evaporation reduces the interlayer adhesion. Based on this assumption, an analytical model is proposed. The model accounts for the pass time, bleeding, and the environmental evaporation rate to estimate the surface moisture and predict the lack of interlayer adhesion. In this study, the model accurately (RMSE = 2.5%) predicted an interlayer adhesion reduction from 30% to 50%. The interlayer adhesion results of other studies could also be predicted.

36 MATERIALS SCIENCE↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

Growth and characterization of Cl-doped ZnO hexagonal nanodisks

Cl-doped ZnO nanodisks were grown on a Si(111) substrate using a thermal evaporation method. The prepared nanodisks exhibited a hexagonal shape with an average thickness of 50 nm and average diagonal of 270 nm. In addition, undoped ZnO disks with hexagonal shape were grown under the same conditions, but the sizes of these undoped ZnO disks were on the micrometer order. A possible mechanism was proposed for the growth of the Cl-doped ZnO nanodisks, and it was shown that the Cl{sup 1-} anions play a crucial role in controlling the size. X-ray diffraction and Raman spectroscopy clearly showed an extension in the crystal lattice of ZnO because of the presence of chlorine. In addition, these nanodisks produced a strong photoluminescence emission peak in the ultraviolet (UV) region and a weak peak in the green region of the electromagnetic spectrum. Furthermore, the UV peak of the Cl-doped ZnO nanodisks was blueshifted with respect to that of the undoped ZnO disks. - Graphical abstract: Cl-doped ZnO nanodisks and undoped ZnO microdisks have been grown using a thermal evaporation method. Highlights: > Cl-doped ZnO nanodisks with hexagonal shape are grown using a thermal evaporation method. > It is shown that the Cl{sup 1-} anions play a crucial role in controlling the size of the nanodisks. > XRD and Raman results showed that the Cl-doped ZnO nanodisks structure is under a biaxial stress. > UV peak of the PL spectrum is blueshifted for the Cl-doped ZnO nanodisks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗