Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC PULSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

Growth of Cu{sub 2}O on Ga-doped ZnO and their interface energy alignment for thin film solar cells

Cu{sub 2}O thin films are deposited by direct current reactive magnetron sputtering on borofloat glass and indium tin oxide (ITO) coated glass at room temperature. The effect of oxygen partial pressure on the structures and properties of Cu{sub 2}O thin films are investigated. We show that oxygen partial pressure is a crucial parameter in achieving pure phases of CuO and Cu{sub 2}O. Based on this finding, we fabricate heterojunctions of p-type Cu{sub 2}O with n-type gallium doped ZnO (GZO) on ITO coated glass substrates by pulsed laser deposition for GZO thin films. The energy band alignment for thin films of Cu{sub 2}O/GZO on ITO glass is characterized using high-resolution x-ray photoelectron spectroscopy. The energy band alignment for the Cu{sub 2}O/GZO heterojunctions is determined to be type II with a valence band offset of 2.82 eV and shows negligible effects of variation with gallium doping. The higher conduction band of the Cu{sub 2}O relative to that of GZO in the obtained band alignment shows that the heterojunctions are suitable for solar cell application based on energy levels consideration.

36 MATERIALS SCIENCE↗

Study of physical properties of integrated ferroelectric/ferromagnetic heterostructures

Superlattices (SLs) with different periodicity of ferromagnetic La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) and ferroelectric Ba{sub 0.7}Sr{sub 0.3}TiO{sub 3} as constitutive layers were fabricated on conducting LaNiO{sub 3} coated (001) oriented MgO substrates using pulsed laser deposition. The crystallinity, ferroelectric, and magnetic properties of the SLs were studied over a wide range of temperatures and frequencies. The structure exhibited ferromagnetic behavior at 300 K and ferroelectric behavior over a range of temperatures between 100 and 300 K. A frequency-dependent change in dielectric constant and tangent loss were observed above the ferromagnetic-paramagnetic temperature. The frequency-dependent dielectric anomalies are attributed to the change in metallic and magnetic nature of LSMO and also the interfacial effect of two different phases that are connected alternatively in series. The effect of ferromagnetic LSMO layers on ferroelectric properties of the SLs indicated strong influence of the interfaces. The asymmetric behavior of ferroelectric loop and the capacitance-voltage relationship suggest development of a built field in the SLs due to high strain across the interfaces.

36 MATERIALS SCIENCE↗

Plasma Diagnostics of a Capillary Plasma Channel for Laser Guiding

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapidly reconfigurable slow-light system based on off-resonant Raman absorption

We present a slow-light system based on dual Raman absorption resonances in warm rubidium vapor. Each Raman absorption resonance is produced by a control beam in an off-resonant {Lambda} system. This system combines all optical control of the Raman absorption and the low-dispersion broadening properties of the double Lorentzian absorption slow light. The bandwidth, group delay, and central frequency of the slow-light system can all be tuned dynamically by changing the properties of the control beam. We demonstrate multiple pulse delays with low distortion and show that such a system has fast switching dynamics and thus fast reconfiguration rates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Numerical analysis of laser-driven reservoir dynamics for shockless loading

Laser-driven plasma loader for shockless compression provides a new approach to study the rapid compression response of materials not attainable in conventional shock experiments. In this method, the strain rate is varied from {approx}10{sup 6}/s to {approx}10{sup 8}/s, significantly higher than other shockless compression methods. Thus, this loading process is attractive in the research of solid material dynamics and astrophysics. The objective of the current study is to demonstrate the dynamic properties of the jet from the rear surface of the reservoir, and how important parameters such as peak load, rise time, shockless compression depth, and stagnating melt depth in the sample vary with laser intensity, laser pulse length, reservoir thickness, vacuum gap size, and even the sample material. Numerical simulations based on the space-time conservation element and solution element method, together with the bulk ablation model, were used. The dynamics of the reservoir depend on the laser intensity, pulse length, equation of state, as well as the molecular structure of the reservoir. The critical pressure condition at which the reservoir will unload, similar to a gas or weak plasma, is 40-80 GPa before expansion. The momentum distribution bulges downward near the front of the plasma jet, which is an important characteristic that determines shockless compression. The total energy density is the most important parameter, and has great influence on the jet characteristics, and consequently on the shockless compression characteristics. If the reservoir is of a single material irradiated at a given laser condition, the relation of peak load and shockless compression depth is in conflict, and the highest loads correspond to the smallest thickness of sample. The temperature of jet front runs up several electron volts after impacting on the sample, and the heat transfer between the stagnating plasma and the sample is sufficiently significant to induce the melting of the sample surface. However, this diffusion heat wave propagates much more slowly than the stress wave, and has minimal effect on the shockless compression progress at a deeper position.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of the molecular response to light upon photoexcitation

Abstract When a molecule interacts with light, its electrons can absorb energy from the electromagnetic field by rapidly rearranging their positions. This constitutes the first step of photochemical and photophysical processes that include primary events in human vision and photosynthesis. Here, we report the direct measurement of the initial redistribution of electron density when the molecule 1,3-cyclohexadiene (CHD) is optically excited. Our experiments exploit the intense, ultrashort hard x-ray pulses of the Linac Coherent Light Source (LCLS) to map the change in electron density using ultrafast x-ray scattering. The nature of the excited electronic state is identified with excellent spatial resolution and in good agreement with theoretical predictions. The excited state electron density distributions are thus amenable to direct experimental observation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance of an AGATA asymmetric detector

Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4{pi} ball of germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF generation in the DARHT Axis-II beam dump

We have occasionally observed radio-frequency (RF) electromagnetic signals in the downstream transport (DST) of the second axis linear induction accelerator (LIA) at the dual-axis radiographic hydrodynamic testing (DARHT) facility. We have identified and eliminated some of the sources by eliminating the offending cavities. However, we still observe strong RF in the range 1 GHz t0 2 GHz occurring late in the ~2-μs pulse that can be excited or prevented by varying the downstream tune. The narrow frequency width (<0.5%) and near exponential growth at the dominant frequency is indicative of a beam-cavity interaction, and electro-magnetic simulations of cavity structure show a spectrum rich in resonances in the observed frequency range. However, the source of beam produced RF in the cavity resonance frequency range has not been identified, and it has been the subject of much speculation, ranging from beam-plasma or beam-ion instabilities to unstable cavity coupling.

43 PARTICLE ACCELERATORS↗

Numerical gate synthesis for quantum heuristics on bosonic quantum processors

There is a recent surge of interest and insights regarding the interplay of quantum optimal control and variational quantum algorithms. We study the framework in the context of qudits which are, for instance, definable as controllable electromagnetic modes of a superconducting cavity system coupled to a transmon. By employing recent quantum optimal control approaches described in (Petersson and Garcia, 2021), we showcase control of single-qudit operations up to eight states, and two-qutrit operations, mapped respectively onto a single mode and two modes of the resonator. We discuss the results of numerical pulse engineering on the closed system for parametrized gates useful to implement Quantum Approximate Optimization Algorithm (QAOA) for qudits. The results show that high fidelity ( > 0.99) is achievable with sufficient computational effort for most cases under study, and extensions to multiple modes and open, noisy systems are possible. The tailored pulses can be stored and used as calibrated primitives for a future compiler in circuit quantum electrodynamics (cQED) systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

X-Ray Free Electron Laser Interaction With Matter

X-ray free electron lasers (XFELs) will enable studying new areas of laser-matter interaction. We summarize the current understanding of the interaction of XFEL pulses with matter and describe some of the simulation approaches that are used to design experiments on future XFEL sources. Modified versions of these models have been successful in guiding and analyzing experiments performed at the extreme-ultraviolet FEL FLASH at wavelengths of 6 nm and longer. For photon energies of several keV, no XFEL-matter interaction experiments have been performed yet but data is anticipated to become available in the near future, which will allow to test our understanding of the interaction physics in this wavelength regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of THz radiation with devices made from wafers with HgTe and InSb quantum wells

In this study we present measurements of the Terahertz (THz) photoconductivity of 2D electron system realized at HgTe/HgCdTe and AlInSb/InSb/AlInSb quantum wells (QWs) in Corbino geometry (inner and outer radius: 500 {mu}m and 1500 {mu}m) with different mobilities and electron densities. To characterize the devices, the Shubnikov-de Haas (SdH) effect up to magnetic fields B of 7T and current-voltage (I-V) characteristics at various magnetic fields were measured. The THz radiation is provided by a p-Ge laser which operates with a magnetic field and a high voltage for the electrical pumping. The stimulated emission is caused by transitions between Landau levels of light holes [1]. The laser is tunable in the range between 1.7 to 2.5 THz (corresponding to wavelengths between 120 to 180 {mu}m or energies of 7 to 12 meV). The laser is pulsed with a pulse rate of 1 Hz and pulse lengths of about 1 {mu}s with low switching times (about 20 ns). The monochromatic THz radiation is transferred to our samples via a 0.32m long brass waveguide immersed in liquid Helium. The detection of a change in the conductivity of the sample due to absorption of THz-radiation (photoresponse) requires a low-noise circuit. For the Corbino-shaped samples the photoresponse (PR) is measured via a resistor R{sub V} of 1 k{Omega}. The signal is transferred via in a high-frequency cable and detected with a digital oscilloscope.

36 MATERIALS SCIENCE↗

A 10{sup 9} neutrons/pulse transportable pulsed D-D neutron source based on flexible head plasma focus unit

A 17 kJ transportable plasma focus (PF) device with flexible transmission lines is developed and is characterized. Six custom made capacitors are used for the capacitor bank (CB). The common high voltage plate of the CB is fixed to a centrally triggered spark gap switch. The output of the switch is coupled to the PF head through forty-eight 5 m long RG213 cables. The CB has a quarter time-period of 4 μs and an estimated current of 506 kA is delivered to the PF device at 17 kJ (60 μF, 24 kV) energy. The average neutron yield measured using silver activation detector in the radial direction is (7.1 ± 1.4) × 10{sup 8} neutrons/shot over 4π sr at 5 mbar optimum D{sub 2} pressure. The average neutron yield is more in the axial direction with an anisotropy factor of 1.33 ± 0.18. The average neutron energies estimated in the axial as well as in the radial directions are (2.90 ± 0.20) MeV and (2.58 ± 0.20) MeV, respectively. The flexibility of the PF head makes it useful for many applications where the source orientation and the location are important factors. The influence of electromagnetic interferences from the CB as well as from the spark gap on applications area can be avoided by putting a suitable barrier between the bank and the PF head.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

11.424 Ghz Stripline Transversal Filter for Sub-Picosecond Bunch Timing Measurements

Measurement of time-of-arrival or instantaneous longitudinal position is a fundamental beam diagnostic. We present results from a stripline transversal periodic coupler structure which forms the heart of a sub-ps beam timing detector. This filter structure approximates a sinx/x response in the frequency domain which corresponds to a limited pulse length response in the time domain. These techniques have been used extensively in beam feedback systems at 3 GHz center frequencies with operational single-shot resolutions of 200 fs [1]. We present a new design, based on a 11.424 GHz center frequency, which is intended to offer a factor of four improvement in time resolution. Two-dimensional electromagnetic simulation results are shown, and the design optimization approach leading to the final circuit implementation is illustrated. The prototype circuit has been fabricated on 64mil Rogers 4003 and lab frequency domain and time domain data are compared to the 2-D simulation results. Performance of the prototype circuit is shown with applicability to sub-ps beam measurements in LINAC and FEL applications.

43 PARTICLE ACCELERATORS↗

Radiobiological study by using laser-driven proton beams

Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of gamma-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface-wave mechanism of subwavelength imaging by a flat left-handed superlens

We develop a theory describing the dynamics and interaction of electromagnetic surface waves (ESWs) resonantly excited by an external source in a slab of left-handed material (LHM) with identical negative (equal to -1) values of dielectric permittivity and magnetic permeability that makes up a so-called perfect lens, or a superlens. We show that subwavelength imaging by a superlens is associated with the degeneracy of the spectrum of eigen electromagnetic surface modes at the interfaces of the metamaterial slab, whereas the dynamic response of the superlens is completely determined by the dynamics of these modes and the dispersion properties of the metamaterial. We obtain conditions that enable one to find out when a superlens produces subwavelength images of an external source. We consider the cases of a stationary and a pulse source, as well as of a source that moves with constant velocity or oscillates in space.

36 MATERIALS SCIENCE↗