Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

A spectral identification technique for adaptive attitude control and pointing of the Space Telescope

The Space Telescope is a 2.4 m class aperture optical telescope having near-diffraction-limited performance. It will be placed into earth orbit by 1980 via the Space Shuttle. The problem considered is how to achieve negligible degradation of the astronomy imaging capability (to 0.005 arc second) due to smearing by pointing motions during observations. Initially, pointing instability sources were identified and a linear stability was used to assess the magnitude of elastic body modes and to design control system compensation regions necessary for subsequent adaptive control. A spectral identification technique for this adaptive attitude control and pointing has been investigated that will alleviate requirements for comprehensive dynamic ground testing. Typical all-digital simulation results describing motions of the telescope line of sight are presented.

Teuber, D. L.↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

James Webb Space Telescope: The First Light Machine

NASA James Webb Space Telescope (JWST) will search for the first luminous objects of the Universe to help answer fundamental questions about how the Universe came to look like it does today. At 6.5 meters in diameter, JWST will be the world's largest space telescope. Its architecture, e.g. aperture, wavelength range and operating temperature, is driven by JWST's science objectives. Introduction: Scheduled to start its 5 year mission after 2018, JWST will study the origin and evolution of galaxies, stars and planetary systems. Its science mission is to: Identify the first bright objects that formed in the early Universe, and follow the ionization history. Determine how galaxies form. Determine how galaxies and dark matter, including gas, stars, metals, overall morphology and active nuclei evolved to the present day. Observe the birth and early development of stars and the formation of planets. And, study the physical and chemical properties of solar systems for the building blocks of Life. Principle: To accomplish the JWST science objectives requires a larger aperture infrared cryogenic space telescope. A large aperture is required because the objects are very faint. The infrared spectral range is required because the objects are so far away that their ultraviolet and visible wavelength spectral lines are red-shifted into the infrared. Because the telescope is infrared, it needs to be cryogenic. And, because of the telescope is infrared, it must operate above the Earth's atmosphere, i.e. in space. JWST is probably the single most complicated mission that humanity has attempted. It is certainly the most difficult optical fabrication and testing challenge of our generation. The JWST 6.5 m diameter primary mirror is nearly a parabola with a conic constant of -0.9967 and radius of curvature at 30K of 15.880 m. The primary mirror is divided into 18 segments with 3 different prescriptions; each with its own off-axis distance and aspheric departure. The radius of curvature for all 18 segments must match to +/- 0.150 mm at 30K. JWST is diffraction limited at 2 micrometers which translates into a transmitted wavefront specification of 156 nm rms. Of that amount, 50 nm rms is allocated to the primary mirror. Each segment is allocated 22 nm rms surface error. At the start of the JWST program, the capability to make such a mirror did not exist. In 1996, NASA began a systematic and comprehensive mirror technology development effort which resulted in JWST. This program resulted in a qualified mirror fabrication process being approved in 2006. Today, all JWST primary mirror segments meet their requirements and are on schedule for a 2018 launch. The next step is system level assembly, integration and test. Ambient tests will be conducted at Goddard Space Flight Center and cryogenic system level testing will be performed in Chamber A at the Johnson Space Center.

Stahl, H. Philip↗

Cold Spray Deposition of 304L Stainless Steel to Mitigate Chloride-Induced Stress Corrosion Cracking in Canisters for Used Nuclear Fuel Storage

A feasibility study of the cold spray deposition process of 304L stainless steel on 304L stainless steel substrates as a mitigation method for chloride-induced stress corrosion cracking (CISCC) has been investigated under various substrate conditions. The study is aimed at the application of this technology to mitigate CISCC that may potentially occur in or nearthe fusion welded regions of stainless steel canisters in Dry Cask Storage System (DCSS) for used nuclear fuels. Spherical gas-atomized 304L stainless steel powder, in the size range of 25 µm to 44 µm, was used as a feedstock powder for the cold spray process. The powder was deposited on four types of 304L substrates with various surface conditions: as-polished, oxidized, cold-rolled, plates with prototypical CISCC. The effects of cold spray parameters on quality of cold spray coatings were investigated. Thickness, porosity, and phases in the as-deposited materials were evaluated using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and correlated with microhardness and adhesion strength measured via micro-indentation and ASTM C633 pulling test, respectively. XRD analysis of the coatings was also conducted to examine the effects of cold spray condition on residual stress state in the coating. Detailed cross-sectional examination of coating/substrate interfaces was performed with transmission electron microscopy (TEM) equipped with energy dispersive spectroscopy (EDS). Dense and continuous coatings with good adhesion strength and hardness were produced for the various substrate conditions by adjusting cold spray parameters. The results demonstrate that cold spray stainless steel coating is a viable option to provide a physical barrier against CISCC in fusion weld regions of stainless steel in corrosive chloride salt-bearing environments.

Dry Cask Storage Systems, cold spray, 304L stainle↗

Epitaxial growth of oriented CoO films by radio-frequency sputtering deposition

Rock-salt CoO is a p-type semiconductor and its Neel temperature is close to room temperature. CoO-based compounds are known as promising systems for renewable energy harvest with high efficiency. CoO with catalytic and exchange bias properties can be widely used for industrial applications. In this paper, we report high-quality stable CoO(111) and (100) films epitaxially grown on c-cut (0001) and r-cut ($10\bar1$2) alpha-Al 2 O 3 substrates, respectively, using radio-frequency sputtering deposition. X-ray diffraction (XRD) measurements revealed that the CoO films had a rock-salt structure (Fm3m) with lattice constants of 4.2477 Å and 4.2617 Å for film grown on (0001) and ($10\bar1$2) α-Al 2 O 3 substrates, respectively. CoO films with the best crystal quality were grown at a substrate temperature of similar to ~700°C. XRD measurements of CoO(111) films indicated a lack of structural residual strain, whereas CoO(100) films had substantial amounts of structural strain. X-ray reflectivity (XRR) and transmission electron microscopy measurements showed neither oxygen vacancy nor defects in both CoO(111) and (100) films. Further, XRR revealed that the mean electron density of the CoO films was nearly identical to a pure CoO and that the films were considerably stable under the atmosphere.

36 MATERIALS SCIENCE↗

Crystal Chemistry and Thermodynamics of HREE (Er, Yb) Mixing in a Xenotime Solid Solution

Rare earth elements (REEs), the 15 naturally occurring lanthanides plus yttrium and scandium, are ubiquitously used in modern life as they are critical components of many advanced devices and technologies. However, the demand for REEs is not equal, with the heavy rare earth elements (HREEs) having a higher demand. Xenotime (HREEPO 4 ) is an important HREE ore mineral and globally is an economical source of HREE. Most of the crystallographic and thermodynamic properties of xenotime endmembers have been elucidated by calorimetric, solubility, and high-pressure studies. Yet, in natural systems, endmembers are rarely encountered, and instead, REE solid solutions are more commonly observed. Here, we characterize the crystal chemistry, thermodynamics of HREE mixing, and high-temperature material behaviors and thermochemistry of a synthetic erbium (Er)-ytterbium (Yb) binary xenotime solid solution (Er (x) Yb (1-x) PO 4 ) using a suite of experimental techniques, including X-ray fluorescence spectroscopy, synchrotron X-ray powder diffraction implemented with Rietveld analysis, Fourier transform infrared spectroscopy coupled with attenuated total reflectance, Raman spectroscopy, thermogravimetric analysis coupled with differential scanning calorimetry, and high-temperature oxide melt drop solution calorimetry. Our results shed light on the formation of natural xenotimes and lay the foundation for their industrial applications as thermal coating materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR↗

Perfect Crystals: microgravity capillary counterdiffusion crystallization of human manganese superoxide dismutase for neutron crystallography

The NASA mission Perfect Crystals used the microgravity environment on the International Space Station (ISS) to grow crystals of human manganese superoxide dismutase (MnSOD)—an oxidoreductase critical for mitochondrial vitality and human health. The mission’s overarching aim is to perform neutron protein crystallography (NPC) on MnSOD to directly visualize proton positions and derive a chemical understanding of the concerted proton electron transfers performed by the enzyme. Large crystals that are perfect enough to diffract neutrons to sufficient resolution are essential for NPC. This combination, large and perfect, is hard to achieve on Earth due to gravity-induced convective mixing. Capillary counterdiffusion methods were developed that provided a gradient of conditions for crystal growth along with a built-in time delay that prevented premature crystallization before stowage on the ISS. Here, we report a highly successful and versatile crystallization system to grow a plethora of crystals for high-resolution NPC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of Tantalum and Hafnium Carbide Fibers via Forcespinning TM for Ultrahigh‐Temperature Applications

In this work, a novel method for producing ultrafine tantalum and hafnium carbide fibers using the Forcespinning TM technique via a nonhalide‐based sol‐gel process was investigated. An optimal solution viscosity range was systematically determined via rheological studies of neat PAN/DMF as a function of fiber formation. Subsequently, Forcespinning TM parameters were also systemically studied to determine the optimal rotational velocity and spinneret‐to‐collecting rod distance required for ideal fiber formation. TaC and HfC fibers were synthesized via Forcespinning TM utilizing a mixture of PAN and refractory transition metal alkoxides (i.e., tantalum (V) ethoxide and hafnium (IV) tert‐butoxide) in DMF solution based on optimal conditions determined from the neat PAN/DMF. In all instances after calcination, powder X‐ray diffraction (PXRD) and energy dispersive spectroscopy (EDS) indicated that TaC and HfC fibers were produced. TGA/DSC confirmed the chemical stability of the resulting fibers.

Lee, Harold O.↗

Seismo-Acoustic Wave Simulation for the 2016 Kumamoto Earthquake

It is well known that underground explosions or earthquakes can generate infrasound in the atmosphere. Seismoacoustic coupling between the ground motions and atmosphere is a key mechanism for infrasound generation. Epicentral infrasound which is direct response to epicentral ground motions are extensively studied for event detection and discrimination. Diffracted infrasound generated from Rayleigh waves are often observed and reported. Recent studies suggested the surface topography is also important for infrasound generation, and mountains or topographic peaks can act as effective secondary infrasound sources. In this study, we perform full 3-D seismoacoustic simulations to understand a coupled seismic and acoustic wave generation by an earthquake and energy partitioning across the solid Earth-ocean-atmosphere system. By including the effects of realistic topography, bathymetry, and earthquake focal mechanism, we provide quantitative information about seismoacoustic wavefields and secondary infrasound sources across the solid-water, solid-air, and water-air interfaces. Acoustic wave transmission across water-air interface is also investigated by using synthetic waveforms. Our study suggests that shallow seas near the coastline or over elevated seafloors can transmit significant amount of energy from acoustic waves in water and can be effective secondary infrasound sources.

58 GEOSCIENCES↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Composition on the Phase Structure and Magnetic Properties of Ball-Milled LaFe11.71-xMnxSi1.29H1.6 Magnetocaloric Powders

Magnetocaloric alloys are an important class of materials that enable non-vapor compression cycles. One promising candidate for magnetocaloric systems is LaFeMnSi, thanks to a combination of factors including low-cost constituents and a useful curie temperature, although control of the constituents’ phase distribution can be challenging. In this paper, the effects of composition and high energy ball milling on the particle morphology and phase stability of LaFe11.71-xMnxSi1.29H1.6 magnetocaloric powders were investigated. The powders were characterized with optical microscopy, dynamic light scattering, X-ray diffraction (XRD), and differential scanning calorimetry (DSC). It was found that the powders retained most of their original magnetocaloric phase during milling, although milling reduced the degree of crystallinity in the powder. Furthermore, some oxide phases (<1 weight percent) were present in the as-received and milled powders, which indicates that no significant contamination of the powders occurred during milling. Finally, the results indicated that the Curie temperature drops as Fe content decreases (Mn content increases). In all of the powders, milling led to an increase in the Curie temperature of ~3–6 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plans for a large deployable reflector for submillimeter and infrared astronomy from space

Continuing plans for a large deployable reflector (LDR), conceived as a 10- to 30-m-diameter clear-aperture telescope, operating at wavelengths from 1000 microns to a diffraction-limited 30 microns, and to be placed in orbit for a life of 10 years by the Space Shuttle, are discussed. The primary reflector will be composed of a number of closely packed hexagonal segments of glass or lightweight composite material and attached to a truss integrating structure through position actuators providing three degrees of freedom for each segment. Technical aspects of optical design, surface measurement systems, deployment, and detectors are discussed, as are practical and fiscal limitations.

Swanson, P. N.↗

Real-time optical correlator using photorefractive GaAs

A real-time optical correlator based on GaAs and liquid-crystal TV (LCTV) is demonstrated. The demonstrated system has a video-frame rate limited by the speed of the LCTVs; if faster spatial-light modulators are used, the potential frame rate of a GaAs-based correlator can be as fast as 1000 frames/sec under experimental conditions. Comparisons are made between VanderLugt and joint transform and between degenerate and nondegenerate four-wave mixing. The edge-enhancement effect and the Bragg diffraction effect are discussed.

Liu, Duncan T. H.↗

Commercial researcher perspective

Protein crystallography--a research tool used to study the structure of the complex building blocks of living systems--has a lot to gain from space-based research. In order to know how a protein works in the human body, researchers must understand its molecular structure. Researchers have identified 150,000 different proteins in the body, but they now know the structure of less than a third of them. The only viable technique for analyzing the structure of these proteins is x-ray diffraction of the proteins in their crystal form. The better the quality of a protein crystal, the more useful it is to researchers who are trying to delineate its structure. The microgravity environment of space allows protein crystals to grow nearly undisturbed by convection and other gravity-driven forces that cause flaws to form in them on the ground. In space, lack of convection enables protein crystals to grow more slowly than they do on Earth, and the slower a protein crystal grows, the fewer flaws it will have. Protein crystal growth experiments have already flown on 14 Space Shuttle missions. This year's USML-1 Spacelab mission included protein crystal growth experiments conducted for commercial researchers. The results of protein crystal experiments flown thus far have been larger crystals with more uniform morphologies. The Center for Macromolecular Crystallography (A NASA-cosponsored CCDS) currently builds flight hardware to meet researchers' needs and handles sample loading and retrieval for flight experiments. Protein crystallography enables 'rational drug design': the development of drugs that bind only with the target protein and, hence, do not cause side effects. For example, pharmaceutical companies presently are interested in developing drugs that can inhibit purine nucleoside phosphorylase (PNP), a protein that plays a role in auto-immune diseases. To continue these kinds of investigations, researchers need a constant supply of protein crystals that are as free of flaws as possible. Space Station Freedom will provide the kind of research environment that will enable the production of such supplies. In addition, Freedom will provide the kind of long-duration facility required by protein crystal researchers: 40 percent of proteins require more than two weeks to crystallize.

Delucas, Larry↗

The Evolution of the Deformation Substructure in a Ni-Co-Cr Equiatomic Solid Solution Alloy

The equiatomic NiCoCr alloy exhibits an excellent combination of strength and ductility, even greater than the FeNiCrCoMn high entropy alloy, and also displays a simultaneous increase in strength and ductility with decreasing the testing temperature. To systemically investigate the origin of the exceptional properties of NiCoCr alloy, which are related to the evolution of the deformation substructure with strain, interrupted tensile testing was conducted on the equiatomic NiCoCr single-phase solid solution alloy at both cryogenic and room temperatures at five different plastic strain levels of 1.5%, 6.5%, 29%, 50% and 70%. The evolution of deformation substructure was examined using electron backscatter diffraction (EBSD), transmission Kikuchi diffraction (TKD), conventional transmission electron microscopy (CTEM), diffraction contrast imaging using STEM (DCI-STEM) and atomic resolution scanning transmission electron microscopy. While the deformation substructure mainly consisted of planar dislocation slip and the dissociation of dislocations into stacking faults at small strain levels (≤6.5%), at larger strain levels, additional substructures including nanotwins and a new phase with hexagonal close packed (HCP) lamellae also appeared. The volume fraction of the HCP lamellae increases with increasing deformation, especially at cryogenic temperature. First principles calculations at 0 K indicate that the HCP phase is indeed energetically favorable relative to FCC for this composition. The effects of the nanotwin and HCP lamellar structures on hardening rate and ductility at both cryogenic and room temperature are qualitatively discussed.

Twinning↗