Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design for reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Reliability-Informed Life Cycle Warranty Cost and Life Cycle Analysis of Newly Manufactured and Remanufactured Units

Standard life cycle techniques such as life cycle warranty cost (LCWC) analysis and life cycle analysis (LCA) are used to respectively quantify the relative economical and environmental advantages of remanufactured goods while simultaneously identifying avenues for improvement. In this paper, we contribute to the literature on life cycle studies by incorporating reliability into LCWC analysis and LCA with the goal of improving long-term/multiple life cycle decision making. We develop a branched power-law model to incorporate the physical degradation mechanisms leading to reduced reuse rates of system parts over multiple life cycles. We then follow a standard LCA protocol to quantify the difference between a new unit and its remanufactured version in terms of environmental impact items such as abiotic depletion potential, global warming potential, and energy consumption. We then devise four practical warranty policies that vary in the choice of replacement and/or provision for extended warranty. All possible replacement scenarios for multiple life cycles are explored for each policy and a mathematically rigorous framework is provided, where the reliability information is used to calculate probabilistic LCWC and life cycle impact items. This reliability-informed LCWC analysis and LCA framework enables design engineers to compare design options and warranty policies by quantifying both economical and environmental impacts to aid in decision making. Although the framework is presented in a general form applicable to any engineered system, we demonstrate the utility of this framework by using a case study of an infinitely variable transmission used in agricultural equipment.

42 ENGINEERING↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Cutter Blade Wear in Rotary Shear Mills

Following development of an analytical abrasive wear model to predict wear of components in a rotary shear mill, the team used a finite element analysis (FEA) approach to calculate forces and loads acting on particles responsible for abrasive wear. The analytical model related critical rotary shear process parameters (shear geometry and rotational speed) to critical material attributes of inorganic mineral species in feedstock (density, size, and aspect ratio) and substrate (hardness and elastic modulus) that enabled us to model the wear of shear cutters in a rotary shear milling system developed by Forest Concepts. With proper knowledge of the forces acting between abrasive particles and cutter components built into it, the model can accurately predict wear of the cutters and provides a quality by design (QbD) approach to predict component reliability based on scientific engineering principles in lieu of trial-and-error approaches. During this reporting period, researchers at Oak Ridge National Laboratory applied an FEA package to simulate the local stresses and forces between an abrasive silica particle and two rotary shear cutters as the distance between the cutters decreases. The output of the FEA was used to provide more accurate projections of the loads applied to the particles in the analytical wear model. Comparison of the FEA force calculations are in good agreement with the loads assumed in the analytical predictions.

36 MATERIALS SCIENCE↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D modeling of the Staged Z-pinch with the FLASH code

The Staged Z-pinch (SZP) fusion concept is a magneto-inertial compression scheme developed by Magneto-Inertial Fusion Technologies, Inc. (MIFTI), in which small amounts of fusion fuel are brought to fusion-relevant conditions by passing multi-million amperes strong current through a cylindrical shell of high atomic number material. One- and two-dimensional modeling performed by MIFTI with the MACH2 code, suggests that net fusion energy gain can be achieved when currents in the 10 million amperes range compress a 50%-50% mixture of deuterium and tritium gas. In this project we enhance and use the FLASH code to execute high-fidelity, simulations of various SZP configurations, a collaboration between the Flash Center for Computational Science at the University of Rochester and the Laboratory for Laser Energetics, and MIFTI. FLASH is a high-performance computing, multi-physics, radiation magnetohydrodynamic (MHD) code with extended physics capabilities, which is developed at the Flash Center. The goal of this project is to assess the shell/fuel stability of the pinch to two- and three-dimensional MHD instabilities and to utilize FLASH’s extended physics capabilities to understand how extended-MHD effects impact implosion dynamics and plasma conditions at stagnation. The project is a natural extension of an ongoing collaborative effort between MIFTI and the Flash Center through the U.S. DOE Advanced Research Projects Agency-Energy (ARPA-E) BETHE program and can provide MIFTI with simulation capabilities that are currently beyond their reach with MACH2. Ultimately, MIFTI wants FLASH to become one of their simulation workhorses for reliable, high-fidelity SZP platform design. During the project, the Flash Center team developed a suite of in one- and two-dimensional FLASH simulations to model different variants of the SZP platform, performed code-to-code comparisons with MACH2, and used the FLASH code to design and model SZP experiments like the Double Eagle experiments that MIFTI recently performed. Also, the Flash Center team developed the capabilities of FLASH to be able to do three-dimensional simulations of pulsed-power experiments with the code for the first time. Two publications from this effort are currently under review and two more are in preparation. MIFTI has also committed to the use of FLASH for future SZP simulation efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Wind Guidebook [Slides]

Distributed wind energy technologies generate clean, carbon-free power close to the point of electrical consumption (i.e., close to people and their energy needs). Distributed wind energy can help individuals and communities meet their unique goals, such as reducing impacts on climate change, decreasing electricity bills, boosting energy independence or autonomy from the electric grid, and enhancing grid reliability and resiliency. This guidebook is designed to support individuals and communities in deploying distributed wind energy technologies by providing fundamental information needed for success. Each section is framed around a key question in the journey to deployment and offers resources to help you answer it.

17 WIND ENERGY↗

Distributed Wind Guidebook: Agricultural Producers and Rural Small Business Owners

Distributed wind energy technologies generate clean, carbon-free power close to the point of consumption (i.e., close to people and their energy needs). Distributed wind energy can help individuals, farms, businesses, and communities meet their unique goals, such as reducing impacts on climate change, decreasing electricity bills, boosting energy independence or autonomy from the electric grid, and enhancing grid reliability and resilience. This guidebook is designed to support you in (1) deciding if distributed wind energy is right for you, (2) installing a proven wind turbine technology by working with a reputable installer, and (3) setting up your project for success through its lifetime. The information in this guidebook is tailored to rural small businesses and agricultural producers who are interested in exploring distributed wind energy to meet their electricity, resilience, financial, and environmental goals. You will find gray boxes with key topics, definitions, and considerations throughout the guidebook. The report has been adapted from the Distributed Wind Guidebook, which offers a comprehensive view on core aspects of deploying distributed wind energy technologies. In comparison, this edition of the guidebook is designed to offer a more succinct and tailored guidebook for rural small businesses and agricultural producers. For additional detail on any topic presented within this edition, readers are advised to reference the original version of the Distributed Wind Guidebook.

17 WIND ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-life, space-maintainable nuclear stage regulators and shutoff valves

The six most promising valve, regulator, and remote coupling concepts, representing the more radical designs from twenty concepts generated, were investigated. Of the three valves, one has no moving parts because shutoff sealing is accomplished by an electromagnetic field which ionized the flowing fluid. Another valve uses liquid metal to obtain sealing. In the third valve, high sealing forces are generated by heating and expanding trapped hydrogen. The pressure regulator is an electronically controlled, electromechanically operated, single state valve. Its complexity is in electronic circuitry, and the design results in less weight, increased reliability and performance flexibility, and multipurpose application. The two remote couplings feature the minimization of weight and mechanical complexity. One concept uses a low melting temperature metal alloy which is injected into the joint cavity; upon solidification, the alloy provides a seal and a structural joint. The second concept is based on the differential thermal expansion of the coupling mating parts. At thermal equilibrium there is a predetermined interference between the parts, and sealing is achieved by interference loading.

Source record↗

Tensile failure criteria for fiber composite materials

The analysis provides insight into the failure mechanics of these materials and defines criteria which serve as tools for preliminary design material selection and for material reliability assessment. The model incorporates both dispersed and propagation type failures and includes the influence of material heterogeneity. The important effects of localized matrix damage and post-failure matrix shear stress transfer are included in the treatment. The model is used to evaluate the influence of key parameters on the failure of several commonly used fiber-matrix systems. Analyses of three possible failure modes were developed. These modes are the fiber break propagation mode, the cumulative group fracture mode, and the weakest link mode. Application of the new model to composite material systems has indicated several results which require attention in the development of reliable structural composites. Prominent among these are the size effect and the influence of fiber strength variability.

Rosen, B. W.↗

Detailed design of a 100-We multicell thermionic power supply.

Confirmation of the general trends of a previously reported parametric study of plutonia-fueled thermionic generators in a detailed 100-We generator design. The detailed design takes into account the additional weight of system-integration components and shows that design refinements of all aeroshell components are possible when a specific generator configuration is considered. An optimized 100-We thermionic power supply design is presented, reflecting a 0.98 reliability goal after five years of operation. The optimum multicell array consists of 28 isomite converters, each producing approximately 3.6 We at end-of-life. The optimum arrangement of converters in the aeroshell is a four-column, seven-row stacking configuration connected electrically as a two-column, 14-row array.

Rouklove, P.↗

Digital servo controller behaves like synchro

Encoder has been used for years to measure accurately positional parameters of controlled devices with very high accuracy and reliability. Digital control system has been designed using digital shaft angle encoders.

Byrne, F.↗

Tracking and data relay satellite system configuration and tradeoff study. Volume 1: Summary. Part 2: Final Report, 22 August 1972 - 1 April 1973

A Tracking and Data Relay Satellite System (TDRSS) concept for service of low, medium, and high data rate user spacecraft has been defined. During the study, four TDRS dual spin stabilized configurations (contractual requirement) were designed; two are compatible with Delta 2914, one with Atlas Centaur, and one with space shuttle launches. A summary of the study and the salient results are presented. The topics included are: (1) TDRSS operations, (2) telecommunications service performance, telecommunications service equipment, (3) TDRS configurations and their design characteristics, and (4) TDRS system reliability.

Source record↗