Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cisplatin-Conjugated Porous Gelatin Particles: Assessment of Optimal Conditions for Binding and Release

This study was designed to evaluate the optimal conditions for binding cisplatin and porous gelatin particles (PGPs) and to establish in vivo drug release pharmacokinetics. PGPs were immersed in cisplatin solutions under different conditions: concentration, immersion time, and temperature. Thereafter, PGPs were washed in distilled water to remove uncombined cisplatin and were then freeze-dried. The platinum concentration (PC) in the PGPs was then measured. For the in vivo release test, 50 mg/kg of the cisplatin-conjugated PGPs was implanted subcutaneously in the abdominal region of two rabbits. PCs in the blood were measured at different time intervals. PCs significantly increased in direct proportion to the concentration and immersion time (p < 0.01). Although PC increased at higher solution temperature, it was not a linear progression. For the in vivo release test, platinum was released from cisplatin-conjugated PGPs after 1 day, and the peak PC was confirmed 2 days after implantation. Platinum in the blood was detected until 7 days after implantation in one rabbit and 15 days after administration in the other rabbit. Platinum binding with PGPs increased with a higher concentration of cisplatin solution at a higher temperature over a longer duration of time. Release of cisplatin from cisplatin-conjugated PGPs was confirmed in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Spatial Accuracy of a Fusion Imaging Technique Combining Previously Acquired Computed Tomography and Real-Time Ultrasound for Imaging of Liver Metastases

Purpose: This study was designed to evaluate the spatial accuracy of matching volumetric computed tomography (CT) data of hepatic metastases with real-time ultrasound (US) using a fusion imaging system (VNav) according to different clinical settings. Methods: Twenty-four patients with one hepatic tumor identified on enhanced CT and US were prospectively enrolled. A set of three landmarks markers was chosen on CT and US for image registration. US and CT images were then superimposed using the fusion imaging display mode. The difference in spatial location between the tumor visible on the CT and the US on the overlay images (reviewer no. 1, comment no. 2) was measured in the lateral, anterior-posterior, and vertical axis. The maximum difference (Dmax) was evaluated for different predictive factors.CT performed 1-30 days before registration versus immediately before. Use of general anesthesia for CT and US versus no anesthesia.Anatomic landmarks versus landmarks that include at least one nonanatomic structure, such as a cyst or a calcificationResultsOverall, Dmax was 11.53 {+-} 8.38 mm. Dmax was 6.55 {+-} 7.31 mm with CT performed immediately before VNav versus 17.4 {+-} 5.18 with CT performed 1-30 days before (p < 0.0001). Dmax was 7.05 {+-} 6.95 under general anesthesia and 16.81 {+-} 6.77 without anesthesia (p < 0.0015). Landmarks including at least one nonanatomic structure increase Dmax of 5.2 mm (p < 0.0001). The lowest Dmax (1.9 {+-} 1.4 mm) was obtained when CT and VNav were performed under general anesthesia, one immediately after the other. Conclusions: VNav is accurate when adequate clinical setup is carefully selected. Only under these conditions (reviewer no. 2), liver tumors not identified on US can be accurately targeted for biopsy or radiofrequency ablation using fusion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kummel Disease Treatment by Unipedicular Vertebral Augmentation Using Curved Injection Cannula

Purpose: This study was designed to evaluate the efficacy of the blunt-tipped curved injection needle (BCN) AVAflex (Care Fusion) for vertebral augmentation in cases of Kummel's disease. Methods: We performed 25 vertebral augmentation procedures on 25 consecutive patients (11 men/14 women; mean age, 67 years) with Kummel's disease using the blunt-tipped curved injection needle with PMMA cement. We performed all 25 procedures by unipedicular left approach with patients in prone position under local anesthesia and mild sedation. In all cases, an intravertebral cleft was evident on preprocedural imaging. We evaluated pain intensities by Visual Analogic Scale (VAS) before and at first day, 6 months, and 1 year after procedure. Results: In all cases the curved injection cannula permitted the filling of the clefts and surrounding cancellous bone without any complication. A significant reduction of kyphotic deformities of the treated vertebral bodies was evident. A significance decrease in VAS values at 1 year also was evident (mean decrease 7.2). At plain dynamic postprocedural X-rays checks, there was no sign of pathologic intravertebral motion as evidence of optimal stabilization. Conclusions: BCN AVAflex is a safe and effective device for targeted vertebral augmentation in cases of Kummel's disease. Its distinctive characteristic is the curved injection cannula, which enables targeting the cement injection to areas far off the trajectory of the straight access cannula, thus providing excellent cement spread throughout the entire volume of vertebral body.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bone Marrow Nails Created by Percutaneous Osteoplasty for Long Bone Fracture: Comparisons Among Acrylic Cement Alone, Acrylic-Cement-Filled Bare Metallic Stent, and Acrylic-Cement-Filled Covered Metallic Stent

Purpose: This study was designed to compare the strength among bone marrow nails created to treat long bone fractures using interventional procedures. Methods: Twelve resected intact tibiae of healthy swine were used. A circumferential bone fracture was made in nine tibiae and restored with the following created bone marrow nails: acrylic cement alone (ACA) (n = 3), acrylic-cement-filled bare metallic stent (AC-FBMS) (n = 3), and acrylic-cement-filled covered metallic (AC-FCMS) stent (n = 3). The remaining intact tibiae (n = 3) were used as controls. Results: A bone marrow nail was successfully achieved within 30 min in all swine. The maximum injection volume of acrylic cement for creating ACA, AC-FBMS, and AC-FCMS was 1.7 {+-} 0.3, 3.2 {+-} 0.4, and 2.9 {+-} 0.4 mL, respectively. The thickness of bone marrow nail created in the ACA, AC-FBMS, and AC-FCMS groups was 3.6 {+-} 1.0, 10.3 {+-} 0.26, and 9.6 {+-} 0.32 mm, respectively (AC-FBMS group versus AC-FCMS group, p = 0.038), probably because of leakage of acrylic cement surrounding the interstices. The maximum bending power (kilonewton) and bending strength (newton/mm{sup 2}) in the normal long bone, ACA, AC-FBMS, and AC-FCMS groups were: 1.70 {+-} 0.25 and 79.2 {+-} 16.1; 0.21 {+-} 0.11 and 8.8 {+-} 2.8; 0.46 {+-} 0.06 and 18.2 {+-} 1.6; and 0.18 {+-} 0.04 and 7.8 {+-} 2.7, respectively. Conclusions: Although the maximum bending power and bending strength of AC-FBMS were not satisfactory, it was the most robust of the three marrow nails for restoring fractured long bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

British Society of Interventional Radiology: Biliary Drainage and Stenting Registry (BDSR)

Objectives: This study was designed to audit current practice in percutaneous biliary drainage and stenting in the United Kingdom. Methods: In 2006, the British Society of Interventional Radiology set up the first web-based Biliary Drainage and Stenting Registry (BDSR). This consisted of a series of tick sheets, which were completed online. Data collection included technical and clinical success of the procedures and outcomes at discharge with a separate form for any follow-up visits. Two months before data analysis, all contributors were asked via email to complete any outstanding data. This paper reports on data collected between November 1, 2006 and August 18, 2009. Results: A total of 833 procedures were recorded and were entered by 62 operators from 44 institutions within the United Kingdom. There were 455 men and 378 women with a median age of 69 (range 20-101) years.The majority of procedures were performed by a consultant. Successful drainage of the biliary tree was achieved in 98.7%. Partial or complete relief of symptoms was seen in 65% of patients. Minor complications, predominantly pain (14.3%), were seen in 26% and major complications, predominantly sepsis (3.5%), were seen in 7.9% of patients. Conclusions: These figures provide an essential benchmark for both audit and patient information. Identifying areas of good practice and those that require improvement will ultimately result in better patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization Via Branches from the Splenic Artery in Patients with Hepatocellular Carcinoma

Purpose: This study was designed to evaluate the radiologic findings and imaging response of chemoembolization via branches of the splenic artery in patients with hepatocellular carcinoma (HCC). Methods: From January 2001 to July 2010, we observed tumor staining supplied by branches of the splenic artery in 34 (0.6%) of 5,413 patients with HCC. Computed tomography (CT) scans and digital subtraction angiograms of these patients were retrospectively reviewed in consensus by two investigators. Results: A total of 39 tumor feeding-vessels in 34 patients were identified: omental branches from the left gastroepiploic artery (n = 5), branches from the short gastric artery (n = 9), and omental branches directly from the splenic artery (n = 25). Branches of the splenic artery that supplied tumors were revealed on the celiac angiogram in 29 (85%) of 34 patients and were detected on pre-procedure CT images in 27 (79%) of 34 patients. Selective chemoembolization was achieved in 38 of 39 tumor-feeding vessels. Complete or partial response of the tumor fed by branches of the splenic artery, as depicted on follow-up CT scans, was achieved in 21 (62%) patients. No patient developed severe complications directly related to chemoembolization via branches of the splenic artery. Conclusions: Omental branches directly from the splenic artery are common tumor-feeding vessels of the splenic artery in cases of advanced HCC with multiple previous chemoembolizations. Tumor-feeding vessels of the splenic artery are usually visualized on the celiac angiogram or CT scan, and chemoembolization through them can be safely performed in most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the 'Cheese-wire' Technique

Purpose: This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and 'cheese-wire' technique for fenestration of abdominal aortic dissection membranes. Methods: Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver. Results: We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient. Conclusions: The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors and Complications Associated with Difficult Retrieval of Embolic Protection Devices in Carotid Artery Stenting

Purpose: This study was designed to investigate the risk factors and complications of difficult retrieval (DR) of embolic protection devices (EPDs) in carotid artery stenting (CAS). Methods: A total of 195 consecutive patients who underwent CAS between December 2007 and March 2010 in a general hospital were enrolled and divided into two groups: with DR and without DR. The risk factors of DR were analyzed with univariate and multivariate analyses. The complications of DR were recorded and analyzed. Results: A total of 30 (15.4%) patients with DR of EPDs were observed, of whom EPDs were successfully retrieved in 29, and in 1 was it taken out by surgical treatment. The retrieval time was significantly longer in patients with DR (490.5 {+-} 143.9 s) than in patients without DR (157.2 {+-} 15.7 s, p = 0.000). Vasospasm was observed more frequently in patients with DR than in patients without DR (55.2% vs. 14.5%, p = 0.000). Intracranial compilations were more frequent in patients with DR than in those without DR (17.2% vs. 0.6%, p = 0.000). Calcified plaques, degree of residual stenosis, types of the stents, and tortuosity index (TI > 80 Degree-Sign) were all associated with DR. A logistic regression analysis indicated that calcified plaques (odds ratio (OR) = 6.5; p = 0.000) and TI > 80 Degree-Sign (OR = 18.8; p = 0.000) were independent predictors of DR. Conclusions: Calcified plaques and TI > 80 Degree-Sign may be related to DR in patients with CAS. DR may lengthen the retrieving time and increase the complications of the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Techniques for the Treatment of Renal Artery Aneurysms

Purpose: Our goal was to analyze the indications and limitations of the different percutaneous endovascular approaches reported for the treatment of renal artery aneurysms (RAAs) and to develop a scientific approach for optimum selection of treatment strategy of RAAs through analyzing our experience and reviewing available literature. Methods: This retrospective study was designed to evaluate the treatment and follow-up of 13 consecutive patients who presented with 13 RAAs by using a variety of endovascular interventional techniques. Different combinations of coil embolization, liquid embolization, stenting, and stent-graft exclusion were used in correlation with variable-specific aneurysm criteria. Results: All patients were successfully treated with no significant short- or long-term complications. Patients were followed for an average period of 43 (range 13-103) months. Conclusions: Ten different determinants were found to affect our decision making: shape, size, neck, position of aneurysm on artery, branches arising, artery involved, condition of the artery, age, general condition of the patient, and renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Embolization of the Pancreas Safe? Pancreatic Histological Changes after Selective Transcatheter Arterial Embolization with N-Butyl Cyanoacrylate in a Swine Model

Purpose: This study was designed to evaluate the safety of selective transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) in a swine model in terms of histological changes in the pancreas. Methods: Three groups of two female swine (58-64 kg) per group underwent TAE of the dorsal pancreatic artery, under anesthesia, with 1:1, 1:4, and 1:9 mixtures of NBCA and iodized oil. Blood parameters were evaluated at days 1, 4, and 10 after TAE, after which the animals were sacrificed and pancreatic tissues were examined under light microscopy. Results: All of the animals were asymptomatic and survived for 10 days. Cone beam computed tomographic angiography revealed occlusion of the dorsal pancreatic artery and no enhancement in the embolized area. The white blood cell count and C-reactive protein level were elevated slightly on day 1 after TAE (mean {+-} SD: 252.7 {+-} 27.8 Multiplication-Sign 10{sup 2}/{mu}l and 0.15 {+-} 0.07 mg/l, respectively), but they normalized or remained near the upper normal limit thereafter. The serum amylase and lipase levels also were elevated on day 1 (8831.7 {+-} 2169.2 U/l and 130 {+-} 53.4 U/l, respectively) but normalized thereafter. Histologically, necrosis and fibrosis were noted only in the embolized segment, and necrosis and acute inflammatory reactions were absent in the nonembolized segment. The border between both segments was well defined. Lymphocytic infiltration and foreign body reaction were noted around the embolized vessels. Conclusions: Selective TAE with NBCA in the pancreas caused localized ischemic necrosis without clinically significant pancreatitis; therefore, this procedure is tolerable in swine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Acute Arterial Hemorrhage in Trauma Patients Using Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: This study was designed to determine the feasibility and efficacy of endovascular embolization with liquid embolic agent ethylene vinyl alcohol copolymer (Onyx) in patients with acute traumatic arterial bleeding. Methods: This is a retrospective review of 13 patients (9 men and 4 women; mean age 45 years) with severe trauma who underwent embolotherapy using Onyx from November 2003 to February 2009. Bleeding was located in the pelvis (5 patients), kidney (3 patients), mesenteric region (2 patients), retroperitoneal space (2 patients), neck (1 patient), and thigh (1 patient). In three cases (23.1%), Onyx was used in conjunction with coils. We evaluate the technical and clinical success, procedural and embolization time, occurrence of rebleeding, and embolotherapy-related complications, such as necrosis or migration of Onyx into nontarget vessels. Results: In all patients, embolotherapy was technically and clinically successful on the first attempt. Control of bleeding could be reached with a mean time of 19 (range, 4-63) min after correct placement of the microcatheter in the feeding artery. No recurrent bleeding was detected. No unintended necrosis or migration of Onyx into a nontarget region was observed. During the follow-up period, three patients (23.1%) died due to severe intracranial hemorrhage, cardiac arrest, and sepsis. Conclusions: Transcatheter embolization with new liquid embolic agent Onyx is technically feasible and effective in trauma patients with acute arterial hemorrhage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization of Intramuscular Active Hemorrhage with N-Butyl Cyanoacrylate

Purpose: This study was designed to evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for intramuscular active hemorrhage of varied etiologies and anatomic sites. Methods: Eighteen patients who demonstrated hematoma with pseudoaneurysm and/or active extravasation of contrast media underwent TAE with NBCA. Etiologies of hematoma included trauma, postoperative complication, and coagulopathy (due to underlying disease or anticoagulation therapy). Sites of embolization included chest wall, abdomen wall, retroperitoneum, and extremity. TAE was performed by using 1:3 to 1:5 mixtures of NBCA and iodized oil, either solely (n = 15) or in combination with microcoil (n = 3). The technical and clinical success rate, procedure-related complications, and clinical outcomes were evaluated. Results: The technical and clinical success rates were 100% and 83% (15/18), respectively. Two patients expired while admitted due to other comorbidities. One patient expired due to recurrent bleeding at another site. There were no serious complications relating to the embolization procedure. Conclusions: TAE with NBCA is effective and safe treatment modality for intramuscular active hemorrhage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wingspan Stent for High-Grade Symptomatic Vertebrobasilar Artery Atherosclerotic Stenosis

Purpose: This study was designed to present the treatment outcomes with Wingspan stent angioplasty of high-grade intracranial vertebrobasilar artery (VBA) stenosis in symptomatic patients. Methods: Between 2007 and 2010, the records of 30 patients with 31 intracranial high-grade VBA stenoses (all{>=}70%) who underwent elective stenting due to the failure of medical therapy were retrospectively reviewed. Clinical evaluation was performed based on the modified Rankin scale and the National Institutes of Health Stroke Scale. Results: In all cases, the stent deployment was technically successful. The mean stenosis decreased significantly from 82.28 {+-} 8.02% (range, 72-99%) to 11.18 {+-} 7.28% (range, 0-25%) after stent-assisted angioplasty (P < 0.05). Periprocedure complications occurred in 3 (10%) of 30 patients; there were 2 cases of perforator strokes and 1 case of transient flow insufficiency with stent overlap. Clinical follow-up (mean, 17.81 {+-} 11.49 months; range, 5-40 months) was available for 27 patients, and angiographic follow-up (mean, 9.95 {+-} 5.74 months, range, 5-20 months) was available for 19 patients. Only one case demonstrated recurrent symptoms with restenosis ({>=}50%). There were no recurrent ischemic events and no cases of restenosis in the other patients. Conclusions: According to our data, the Wingspan stent for symptomatic intracranial VBA stenoses is a safe and efficacious treatment alternative in cases with recurrent symptoms despite medical therapy. However, the improvement of outcome requires the reduction in the rate of procedure-related complications and long-term outcomes still have to be demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Doxorubicin Loading for Superabsorbent Polymer Microspheres: in vitro Analysis

Purpose: This study was designed to establish the ability of super-absorbent polymer microspheres (SAP) to actively uptake doxorubicin and to establish the proof of principle of SAP's ability to phase transfer doxorubicin onto the polymer matrix and to elute into buffer with a loading method that optimizes physical handling and elution characteristics. Methods: Phase I: 50-100 {mu}m SAP subject to various prehydration methods (normal saline 10 cc, hypertonic saline 4 cc, iodinated contrast 10 cc) or left in their dry state, and combined with 50 mg of clinical grade lyophilized doxorubicin reconstituted with various methods (normal saline 10 cc and 25 cc, sterile water 4 cc, iodinated contrast 5 cc) were placed in buffer and assessed based on loading, handling, and elution utilizing high-performance liquid chromatography (HPLC). Phase II: top two performing methods were subject to loading of doxorubicin (50, 75, 100 mg) in a single bolus (group A) or as a serial loading method (group B) followed by measurement of loading vs. time and elution vs. time. Results: Phase I revealed the most effective loading mechanisms and easiest handling to be dry (group A) vs. normal saline prehydrated (group B) SAP with normal saline reconstituted doxorubicin (10 mg/mL) with loading efficiencies of 83.1% and 88.4%. Phase II results revealed unstable behavior of SAP with 100 mg of doxorubicin and similar loading/elution profiles of dry and prehydrated SAP, with superior handling characteristics of group B SAP at 50 and 75 mg. Conclusions: SAP demonstrates the ability to load and bulk phase transfer doxorubicin at 50 and 75 mg with ease of handling and optimal efficiency through dry loading of SAP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Anti-tumor Effects of Two Platinum Agents (Miriplatin and Fine-Powder Cisplatin)

Purpose: This study was designed to evaluate the anti-tumor effects of miriplatin-lipidol and fine-powder cisplatin-lipiodol suspensions. Methods: Assessment of the cytotoxicity of two drugs was performed: a soluble derivative of miriplatin (DPC) and fine-powder cisplatin. We randomly divided 15 rabbits with transplanted VX2 liver tumors into three equal groups. They were infused via the proper hepatic artery with a miriplatin-lipiodol suspension (ML), a fine-powder cisplatin-lipiodol suspension (CL), or saline (control) and the tumor growth rate was determined on MR images acquired before and 7 days after treatment. The concentration of platinum (PCs) in blood was assayed immediately, and 10, 30, and 60 min, and 24 h and 7 days after drug administration. Its concentration in tumor and surrounding normal liver tissues was determined at 7 days postadministration. Results: At high concentrations, fine-powder cisplatin exhibited stronger cytotoxicity than DPC. At low concentrations, both agents manifested weak cytotoxicity. While there was no difference between the tumor growth rate of the ML and the CL groups, the difference between the controls and ML- and CL-treated rabbits was significant. The blood PCs peaked at 10 min and then gradually decreased over time. On the other hand, no platinum was detected at any point after the administration of ML. There was no difference between the ML and CL groups in the PCs in tumor tissues; however, in normal hepatic tissue, the PCs were higher in ML- than CL-treated rabbits. Conclusions: We confirmed the anti-tumor effect of ML and CL. There was no significant difference between the anti-tumor effect of ML and CL at 7 days postadministration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗