Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

NASA Advanced Explorations Systems: Advancements in Life Support Systems

The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide environmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions assessed by NASA's Habitability Architecture Team (HAT). The LSS project is focused on four areas: architecture and systems engineering for life support systems, environmental monitoring, air revitalization, and wastewater processing and water management. Starting with the international space station (ISS) LSS systems as a point of departure (where applicable), the mission of the LSS project is three-fold: 1. Address discrete LSS technology gaps 2. Improve the reliability of LSS systems 3. Advance LSS systems towards integrated testing on the ISS. This paper summarized the work being done in the four areas listed above to meet these objectives. Details will be given on the following focus areas: Systems Engineering and Architecture- With so many complex systems comprising life support in space, it is important to understand the overall system requirements to define life support system architectures for different space mission classes, ensure that all the components integrate well together and verify that testing is as representative of destination environments as possible. Environmental Monitoring- In an enclosed spacecraft that is constantly operating complex machinery for its own basic functionality as well as science experiments and technology demonstrations, it's possible for the environment to become compromised. While current environmental monitors aboard the ISS will alert crew members and mission control if there is an emergency, long-duration environmental monitoring cannot be done in-orbit as current methodologies rely largely on sending environmental samples back to Earth. The LSS project is developing onboard analysis capabilities that will replace the need to return air and water samples from space for ground analysis. Air Revitalization- The air revitalization task is comprised of work in carbon dioxide removal, oxygen generation and recovery and trace contamination and particulate control. The CO2 Removal and associated air drying development efforts under the LSS project are focused both on improving the current SOA technology on the ISS and assessing and examining the viability of other sorbents and technologies available in academia and industry. The Oxygen Generation and Recovery technology development area encompasses several sub-tasks in an effort to supply O2 to the crew at the required conditions, to recover O2 from metabolic CO2, and to recycle recovered O2 back to the cabin environment. Current state-of-the-art oxygen generation systems aboard space station are capable of generating or recovering approximately 40% of required oxygen; for exploration missions this percentage needs to be greatly increased. A spacecraft cabin trace contaminant and particulate control system serves to keep the environment below the spacecraft maximum allowable concentration (SMAC) for chemicals and particulates. Both passive (filters) and active (scrubbers) methods contribute to the overall TC & PC design. Work in the area of trace contamination and particulate control under the LSS project is focused on making improvements to the SOA TC & PC systems on ISS to improve performance and reduce consumables. Wastewater Processing and Water Management- A major goal of the LSS project is the development of water recovery systems to support long duration human exploration beyond LEO. Current space station wastewater processing and water management systems distill urine and wastewater to recover water from urine and humidity condensate in the spacecraft at a approximately 74% recovery rate. For longer, farther missions into deep space, that recovery rate must be greatly increased so that astronauts can journey for months without resupply cargo ships from Earth.

Shull, Sarah A.↗

Pterodactyl: Thermal Protection System for Integrated Control Design of a Mechanically Deployed Entry Vehicle

The need for precision landing of high mass payloads on Mars and the return of sensitive samples from other planetary bodies to specific locations on Earth is driving the development of an innovative NASA technology referred to as the Deployable Entry Vehicle (DEV). A DEV has the potential to deliver an equivalent science payload with a stowed diameter 3 to 4 times smaller than a traditional rigid capsule configuration. However, the DEV design does not easily lend itself to traditional methods of directional control. The NASA Space Technology Mission Directorate (STMD)’s Pterodactyl project is currently investigating the effectiveness of three different Guidance and Control (G&C) systems – actuated flaps, Center of Gravity (CG) or mass movement, and Reaction Control System (RCS) – for use with a DEV using the Adaptable, Deployable, Entry, and Placement Technology (ADEPT) design. This paper details the Thermal Protection System (TPS) design and associated mass estimation efforts for each of the G&C systems. TPS is needed for the nose cap of the DEV and the flaps of the actuated flap control system. The development of a TPS selection, sizing, and mass estimation method designed to deal with the varying requirements for the G&C options throughout the trajectory is presented. The paper discusses the methods used to i) obtain heating environments throughout the trajectory with respect to the chosen control system and resulting geometry; ii) determine a suitable TPS material; iii) produce TPS thickness estimations; and, iv) determine the final TPS mass estimation based on TPS thickness, vehicle control system, vehicle structure, and vehicle payload.

Hays, Zane B.↗

Planetary protection issues for sample return missions

Planetary protection (PP) issues for both a comet nucleus sample return (CNSR) mission and a Mars rover sample return (MRSR) mission are discussed, with special attention given to the PP requirements for such missions, the exobiology science objectives for the CNSR and MRSR missions, and a qualitative PP risk assessment for both mission types. A set of contamination control procedures for both missions is presented, which identify procedures for each of the mission phases (i.e., the prelaunch, launch, sample handling, transit vehicle, and earth return). Recommendations for further research and technology development are discussed.

Devincenzi, D. L.↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

Monitoring Immune System Function and Reactivation of Latent Viruses in the Artificial Gravity Pilot Study

Numerous studies have indicated that dysregulation of the immune system occurs during or after spaceflight. Using 21 day -6 degrees head-down tilt bed rest as a spaceflight analog, this study describes the effects of artificial gravity (AG) as a daily countermeasure on immunity, stress and reactivation of clinically important latent herpes viruses. The specific aims were to evaluate psychological and physiological stress, to determine the status of the immune system, and to quantify reactivation of latent herpes viruses. Blood, saliva, and urine samples were collected from each participating subject at different times throughout the study. An immune assessment was performed on all treatment and control subjects that consisted of a comprehensive peripheral immunophenotype analysis, intracellular cytokine profiles and a measurement of T cell function. The treatment group displayed no differences throughout the course of the study with regards to peripheral leukocyte distribution, cytokine production or T cell function. Shedding of Epstein barr virus (EBV), Cytomegalovirus (CMV), and Varicella zoster virus (VZV) was quantified by real time PCR in saliva and urine samples, respectively. There was no significant difference in CMV DNA in the treatment group as compared to the control group. EBV and VZV on the other hand showed a mild reactivation during the study. There were no significant differences in cortisol between the control and treatment groups. In addition, no significant differences between antiviral antibody titers (EBV-VCA, -EA, -EBNA, CMV) or tetramer-positive (EBV, CMV) were found between the two groups. EBV DNA copies in blood were typically undetectable but never exceeded 1,500 copies per 106 PBMCs. Overall, these data indicate that the artificial gravity countermeasure and the 21 day head-down tilt bed rest regimen had no observable adverse effect on immune function.

Mehta, Satish K.↗

Body Composition of Rats on NASA Rodent Foodbar Versus Purina Lab Chow

The objective of this study is to test the nutritional adequacy of the NASA Rodent Foodbar for long term use for rats. The Foodbar was tested on two rat strains, Sprague Dawley and Fischer 344. Rats were fed either Foodbar or the control diet, Purina Chow #5012. Body composition analysis was performed on a selected number of samples (n=6 for each gender and treatment group) as part of extensive testing of the Foodbar. Water, fat, ash, and protein (and their percentages) for both treatment groups were compared. Sprague Dawley Foodbar fed rats had a lower % protein than Chow fed rats (25.8% vs. 30.0%). In addition, Sprague Dawley females fed Foodbar had higher total fat (42.1g vs. 24.6g) and % fat (16.4% vs. 10.5%), but lower % water (51.3% vs. 54.8%) than Sprague Dawley females fed Chow. Fischer 344 Foodbar fed rats had a lower % water (47.4% vs. 49,3%) and total water (93.2g vs. 99.6g). In addition, Fischer 344 Foodbar males had higher % fat (17.0% vs. 13.8%) and total fat (43.0g vs. 34.7g). The data suggests that body composition of Foodbar fed rats tends to have lower water content but a higher fat content compared to controls, but not all results are the same for different strains and even different genders within the same strains. The data obtained here, in addition to other data, helps provide a better understanding of the nutritional adequacy of the Foodbar and whether the formula may need to be modified.

Yu, Diane Sau Mun↗

Space Flown Rodent Liver RNA Sequencing Data for Machine Learning in Space Biology Research

High-throughput nucleic acid sequencing (DNA-seq, RNA-seq) has become widespread in biomedical research due to the growing availability and affordability of these assays. Data analysis has been accelerated in recent years by the adoption of artificial intelligence (AI) and machine learning (ML) techniques by biomedical researchers. In space biology research, RNAseq datasets from space-flown experimental samples are critical for characterizing the gene expression aberrations associated with exposure to spaceflight stressors. However, space biological experiments tend to be very low sample size, so identifying proper AI/ML algorithms for sequencing data analysis is an ongoing challenge since these algorithms typically require large sample size. The NASA Science Mission Directorate (SMD) has started the “Benchmark Initiative for AI/ML”, focused on creating datasets meant for three main applications: 1) scientific benchmarking, which finds the best algorithm for a specific problem; 2) application benchmarking, which measures algorithm performance against a set of parameters; and 3) system benchmarking, which evaluates performance of hardware and software architecture. These scientific benchmarks consist of an AI-ready dataset and a reference implementation on a specific scientific question. In this work, we focused on generating standardized datasets to allow the scientific community to benchmark AI/ML algorithms in the domain of space biology. We present here a standardized, AI-ready, publicly available benchmark dataset for space biology RNA-seq data as a collaboration between the NASA AI4LS (Artificial Intelligence for Life Sciences) working group. and NASA’s SMD. This dataset consists of space-flown and ground control mouse liver found in the NASA GeneLab omics database. However, to amplify the small sample number (n=112 samples) for ML purposes, we employ Gaussian noise and a generative adversarial network to extend this dataset to 6,000 synthetic samples, matching the original gene expression characteristics.

James Casaletto↗

Interactions of atomic oxygen with material surfaces in low Earth orbit: Preliminary results from experiment A0114

The atomic oxygen experiment consisted of two trays (one-sixth of a Long Duration Exposure Facility (LDEF) tray each) of 64 one inch diameter solid samples. It was intended that the effects of atomic oxygen and solar ultraviolet irradiation on the surface properties of each material could be distinguished from each other and from the effects of aging. Sixteen of the samples were placed on a thermally isolated plate of highly polished aluminum, while the main plate was coated with the thermal control coating S13-GLO. Though the experiment was entirely passive, it was hoped that the effects of thermal activation might be observed, if present. The plates were expected to stabilize at temperatures differing by 20-30 C. The samples included thin films of metals Os, Ir, Pt, Ni, Mo, and Al coated onto silica optical flats, metal carbides (WC, SiC), solid carbons of various types, eight polymers, and some other coatings of various types. Analysis is essentially complete using stylus profilometry with high sensitivity Talystep and lower sensitivity Talysurf machines. Though the integrated fluence of O atoms on the LDEF was 30 times that of previous missions, etch depths of the polymers such as the polyimide Kapton show excellent agreement with extrapolations from previous flight data. However, some new effects were observed. We demonstrated on a previous experiment on STS-8 that profilometry of this kind can show steps of 50 A (for example those due to oxide film growth on metals) and this is now the preferred method for estimating etch depth (or mass loss) of erodible substances.

Gregory, John C.↗

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-110 (ISS-8A) in April 2002

The toxicological assessment of grab sample canisters (GSCs) returned aboard STS-110 is reported. Analytical methods have not changed from earlier reports, and surrogate standard recoveries from the GSCs were 77-121%, with one exception. Pressure tracking indicated no leaks in the canisters. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. These five indices of air quality are summarized.

James, John T.↗

Primary Dendrite Arm Spacings in Al-7Si Alloy Directionally Solidified on the International Space Station

Samples from directionally solidified Al- 7 wt. % Si have been analyzed for primary dendrite arm spacing (lambda) and radial macrosegregation. The alloy was directionally solidified (DS) aboard the ISS to determine the effect of mitigating convection on lambda and macrosegregation. Samples from terrestrial DS-experiments thermal histories are discussed for comparison. In some experiments, lambda was measured in microstructures that developed during the transition from one speed to another. To represent DS in the presence of no convection, the Hunt-Lu model was used to represent diffusion controlled growth under steady-state conditions. By sectioning cross-sections throughout the entire length of a solidified sample, lambda was measured and calculated using the model. During steady-state, there was reasonable agreement between the measured and calculated lambda's in the space-grown samples. In terrestrial samples, the differences between measured and calculated lambda's indicated that the dendritic growth was influenced by convection.

Angart, Samuel↗

The role of silver in the processing and properties of Bi-2212

The influence of the silver content and the oxygen partial pressure on the solidus temperature and the weight loss during melting of Bi2Sr2Ca1Cu2O(x) has been examined by means of DTA and TGA. By decreasing the oxygen partial pressure the solidus is lowered (e.g. del T = 59 C by decreasing pO2 from 1 atm to 0.001 atm) and the weight loss is increased. The addition of silver causes two effects: (1) the solidus is further decreased (e.g. 2 wt% Ag lower T (solidus) by up to 25 C, depending on the oxygen partial pressure); and (2) the weight loss during melting is reduced. Thick films (10-20 micron in thickness) with 0 and 5 wt% silver and bulk samples with) and 2.7 wt% silver were melt processed in flowing oxygen on a silver substrate in the DTA, allowing the observation of the melting process and a good temperature control. The critical current densities are vigorously dependent on the maximum processing temperature. The highest j(sub c) in thick films (8000 A/sq cm at 77 K, O T) was reached by melting 7 C above the solidus temperature. The silver addition shows no significant effect on the processing parameters or the superconducting properties. The highest j(sub c) for bulk samples (1 mm in thickness) was obtained by partial melting at 900 C or 880 C, depending on the silver content of the powder (0 or 2.7 wt%). The j(sub c) of the samples is slightly enhanced from 1800 A/sq cm (at 77 K, O T) to 2000 A/sq cm by the silver addition. To be able to reach at least 80% of the maximum critical current density, the temperature has to be controlled in a window of 5 C for thick films and 17 C for bulk samples.

Lang, TH.↗

Thermal Design, Analysis, and Sensitivity of a Sample Tube on the Martian Surface

NASA will launch a rover to Mars in 2020 to collect and cache samples of Martian rocks and regolith for potential return to Earth on a future mission. The collected samples will be placed in tubes, hermetically sealed, and deposited on the surface of Mars for a period of up to 10 years. Preventing the deposited samples from overheating is an important consideration in order to ensure their scientific integrity. The samples are required to remain below 60 °C, however there is a goal to keep them below 40 °C. This temperature requirement is challenging, considering that the maximum surface temperature of Mars is 38 °C and the tube must be thermally controlled through only passive means. As a result, a significant effort has been made to design a tube to contain the samples and investigate innovative tube surface treatments that maintain proper sample temperatures without significant adverse effects of sample contamination. The tube uses a specialized aluminum oxide coating to prevent overheating on the Martian surface. The maximum predicted tube temperature is relatively insensitive to local thermal inertia, ground contact, and ground slope, but is very sensitive to landing site latitude and dust deposition. The maximum predicted sample temperature in the +/- 30° landing latitude range with worst case assumptions is 54 °C, but many of the potential landing sites have significantly cooler maximum predicted sample temperatures. This paper describes the thermal design, analysis, and sensitivity studies performed on the sample tubes and also discusses operational considerations.

Novak, Keith↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Combined dietary and exercise intervention for control of serum cholesterol in the workplace

PURPOSE: To elucidate a potential combined dietary and exercise intervention affect on cardiovascular risk reduction of the National Aeronautics and Space Administration Headquarters employees. DESIGN: A nonexperimental, longitudinal, clinical-chart review study (1987 to 1996) of an identified intervention group and a reference (not a control) group. SETTING: The study group worked in an office environment and participated in the annual medical examinations. SUBJECTS: An intervention group of 858 people with initially elevated serum cholesterol, and a reference group of 963 people randomly sampled from 10% of the study group. MEASURES: Serum cholesterol data were obtained for both groups, respectively, from pre- and postintervention and annual examinations. The reference group was adjusted by statistical exclusion of potential intervention participants. Regression equations (cholesterol vs. study years) for the unadjusted/adjusted reference groups were tested for statistical significance. INTERVENTION: An 8-week individualized, combined dietary and exercise program was instituted with annual follow-ups and was repeated where warranted. RESULTS: Only the unadjusted (but not the adjusted) reference group with initial mean total serum cholesterol levels above 200 mg/dL shows a significant 9-year decline trend and significant beta coefficient tests. An intervention effect is suggested. Mean high density lipoprotein cholesterol rose slightly in the intervention group but was maintained in the reference group. CONCLUSION: With potential design limitations, the NASA intervention program focusing on a high risk group may be associated to some degree, if not fully, with an overall cardiovascular risk profile improvement.

Occupational Health Services↗

Effect of Illumination Angle on the Performance of Dusted Thermal Control Surfaces in a Simulated Lunar Environment

JSC-1A lunar simulant has been applied to AZ93 and AgFEP thermal control surfaces on aluminum substrates in a simulated lunar environment. The temperature of these surfaces was monitored as they were heated with a solar simulator using varying angles of incidence and cooled in a 30 K coldbox. Thermal modeling was used to determine the solar absorptivity (a) and infrared emissivity (e) of the thermal control surfaces in both their clean and dusted states. It was found that even a sub-monolayer of dust can significantly raise the a of either type of surface. A full monolayer can increase the a/e ratio by a factor of 3 to 4 over a clean surface. Little angular dependence of the a of pristine thermal control surfaces for both AZ93 and AgFEP was observed, at least until 30 from the surface. The dusted surfaces showed the most angular dependence of a when the incidence angle was in the range of 25 to 35 . Samples with a full monolayer, like those with no dust, showed little angular dependence in a. The e of the dusted thermal control surfaces was within the spread of clean surfaces, with the exception of high dust coverage, where a small increase was observed at shallow angles.

Gaier, James R.↗

Contamination Mitigation Strategies for Long Duration Human Spaceflight Missions

Contamination control issues are particularly challenging for long-term human spaceflight and are associated with the search for life, dynamic environmental conditions, human-robotic-environment interaction, sample collection and return, biological processes, waste management, long-term environmental disturbance, etc. These issues impact mission success, human health, planetary protection, and research and discovery. Mitigation and control techniques and strategies may include and integrate long-term environmental monitoring and reporting, contamination control and planetary protection protocols, habitation site design, habitat design, and surface exploration and traverse pathways and area access planning.

enviroment↗

Method for X-ray study under extreme temperature and pressure conditions

Vacuum chamber environmental simulator and X ray camera are used to study the stability of various minerals in extreme environmental conditions. An ion pump creates the desired vacuum. Exact sample positioning is obtained with a bellows sealed linear motion feed-through. Temperature control is by means of fluid conductive heat transfer.

Paus, L. L.↗

Atmospheric constituent measurements using commercial 747 airliners

NASA is implementing a Global Atmospheric Monitoring Program to measure the temporal and spatial distribution of particulate and gaseous constituents related to aircraft engine emissions in the upper troposphere and lower stratosphere (6 to 12 Km). Several 747 aircraft operated by different airlines flying routes selected for maximum world coverage will be instrumented. An instrumentation system is being assembled and tested and is scheduled for operation in airline service in late 1974. Specialized instrumentation and an electronic control unit are required for automatic unattended operation on commercial airliners. An ambient air sampling system was developed to provide undisturbed outside air to the instruments in the pressurized aircraft cabin.

Perkins, P. J.↗