Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Dust Control Planning

At the Hanford Site, dust control is required during many activities for health and safety purposes and to prevent contaminant dispersal via atmospheric transport. Water is commonly used to reduce dust dispersal, but can mobilize contaminants and facilitate transport through the vadose zone to groundwater as observed with past activities within the River Corridor. To prevent contaminant mobilization associated with remediation activities in the Central Plateau, alternative approaches for dust suppression are presented considering site-specific requirements at Hanford. There are two high-level categories of approaches to dust control: proactive work strategies to minimize fugitive dust generation and reactive engineered controls to mitigate dust generation and/or capture fugitive dust. Because a variety of activities have the potential to generate fugitive dust at a given site, there is no unique response to dust prevention and control. In fiscal year 2018, an evaluation was completed to identify alternatives, determine limits on surface water additions, and develop information suitable for consideration in feasibility studies. The technical basis detailed in the 2018 evaluation has been condensed into this document that provides a practical Dust Control Plan template and site-specific guidance in the appendices. This Dust Control Plan template specifically provides a workflow to 1) identify key project information, 2) identify fugitive dust sources, 3) assign dust control methods, and 4) determine appropriate monitoring practices to mitigate impacts to groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for Distributed Energy Resource Access Control

Cybersecurity for internet - connected Distributed Energy Resources (DER) is essential for the safe and reliable operation of the US power system. Many facets of DER cybersecurity are currently being investigated within different standards development organizations, research communities, and industry committees to address this critical need. This report covers DER access control guidance compiled by the Access Controls Subgroup of the SunSpec/Sandia DER Cybersecurity Workgroup. The goal of the group was to create a consensus - based technical framework to minimize the risk of unauthorized access to DER systems. The subgroup set out to define a strict control environment where users are authorized to access DER monitoring and control features through three steps: (a) user is identified using a proof-of-identity, (b) the user is authenticated by a managed database, (c) and the user is authorized for a specific level of access. DER access control also provides accountability and nonrepudiation within the power system control environment that can be used for forensic analysis and attribution in the event of a cyber-attack. This paper covers foundational requirements for a DER access control environment as well as offering a collection of possible policy, model, and mechanism implementation approaches for IEEE 1547-mandated communication protocols.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning

Idaho National Laboratory (INL) has contracted IFE to support human factors research and the development of leading-edge technology to support control room operators as the U.S. fleet undergoes modernization and digitalization in legacy plants and control rooms. As the nuclear industry starts to shift to more digital controls and systems, these upgrades provide more information to the main control room in the form of digital signals and values. Also, an increase in the number of alarms points is provided by the vendors. New digital control rooms shift from main control boards to soft controls, and alarm panels to a single display. This change to a single display has created a problem of alarm waterfall, a situation in which the addition of new alarm points causes an overload of information to the operator during either a plant disturbance or other than normal full power operations. IFE’s goal is to find a workable solution to assist operators in both handling and understanding incoming alarms during emergency situations under these waterfall conditions.

99 GENERAL AND MISCELLANEOUS↗

Model Reference Adaptive Control (MRAC) for Additive Manufacturing (AM)

Model Reference Adaptive Control (MRAC) is based on the fundamental concept that the process under investigation is to be controlled to follow or “track” a reference system (model) characterized by a state/input/output model employing an adaptive optimization algorithm to adjust the controller parameters in real-time. The generic structure of the MRAC is shown in Fig. 1 consisting of the following primary components: Reference model, Process (system) model, controller and the adaption algorithm. The basic structure of the controller is specified by a linear construct with the corresponding real-time adaption algorithms given by a gradient-type (so-called MIT rule) or based on stability theory (Lyapunov, hyperstability). This approach to adaptive control is termed “direct”, since the controller (parameters) are adjusted based on the component models/algorithm in contrast to the “indirect” approach that adjusts the process model parameters applying real-time system identification techniques.

42 ENGINEERING↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

LED lighting is becoming widely adopted and displacing most traditional lighting technologies. However, the traditional methods used to control light sources have not seen similar displacement. Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512). The utility and market success of the standardized methods has been limited for a variety of reasons. Analog 0-10V methods have long been popular due to their simplicity and low cost of implementation and are presently the most commonly available control interface for indoor and outdoor LED products in North America. The emergence of “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence was anticipated by many to mark the beginning of the end of analog control. However, 0-10V interfaces continue to be prevalent with these more “digital” systems. The use of 0-10V methods has significant tradeoffs. 0-10V standards have historically not explicitly defined the relationship between the luminaire input control signal and output luminous flux for the full control signal range. As a result, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and in practice the performance across LED drivers and the luminaires power is inconsistent. While this inconsistency has long been acknowledged by experts in the field, it is not accounted for in standard practice deployment, and end-users continue to regularly see unexpected and undesirable performance. It is hoped that the results from this study will help the lighting industry and standards developing organizations better understand and possibly resolve the shortcomings of 0-10V products, and consider what is best for the industry – additional incremental improvements to this fundamentally limited analog technology, or fully moving on to existing digital approaches, such as DALI D4i, that deliver accurate and consistent dimming performance across all luminaires in the system and thus guarantee the delivery of expected light levels, and energy and cost savings. Recommendations consistent with these goals are made to lighting and driver manufacturers, lighting software developers, standard developing organizations, and system designers and specifiers.

0-10V↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This project (1) developed and demonstrated data-driven process controls at full-scale facilities for five promising WRRF process technologies that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) created a Machine Learning (ML) Toolkit and an implementation guide of new process control approaches that walks users through each step of the ML workflow and illustrates the steps through case study examples.

54 ENVIRONMENTAL SCIENCES↗

Multi-Agent Control of Lane-Switching Automated Vehicles for Energy Efficiency

The proliferation of automatic control systems and their connectivity accents the performance of their interactions. In particular, connected and automated vehicles could become high-impact examples thanks to their energy use and productivity effects. Ideally, a controller might collectively optimize all agents' control moves for a given objective. However, limits on computational complexity, incomplete knowledge of the central planner, and risks of a single point of failure make distributed control attractive as well. This paper proposes a collaborative heuristic to approach the performance of centralized control with decentralized-like computational effort. The related centralized controller is also described in detail and evaluated as a baseline. A collaboration-intensive obstacle avoidance scenario involving electric vehicles is simulated to demonstrate benefits over fully decentralized control. While centralized optimization performed best with an 8.6 % energy reduction, the collaborative decentralized scheme reached a favorable computation-performance tradeoff with a 6.7 % energy reduction.

Dollar, R. Austin↗

Online Control of Process Variance Using Feedback

For many stochastic control problem formulations, design objectives typically include constraining the covariance of the outputs of the system. Recent engineering challenges have demonstrated an interest in controlling system output covariances to a setpoint. However, open-loop control of system output covariance can be exceptionally challenging when the system has significant plant uncertainties. This paper explores closed-loop control of the system’s output covariance using a windowed variance function. The stochastic nature of the windowed variance feedback means that root locus and other classical control design techniques cannot be immediately used. Expected value analysis is used to generate transfer functions for the average response of such systems, and the results are used to design controllers. Stochastic simulations are presented to verify the analytical results and make other observations concerning closed-loop variance control.

Bieniek, Mitchell↗

Effects of 5-ion 6-beam sequential irradiation in the presence and absence of hindlimb or control hindlimb unloading on behavioral performances and plasma metabolic pathways of Fischer 344 rats

Introduction Effects and interactions between different spaceflight stressors are expected to be experienced by crew on missions when exposed to microgravity and galactic cosmic rays (GCRs). One of the limitations of previous studies on simulated weightlessness using hindlimb unloading (HU) is that a control HU condition was not included. Methods We characterized the behavioral performance of male Fischer rats 2 months after sham or total body irradiation with a simplified 5-ion 6-mixed-beam exposure representative of GCRs in the absence or presence of HU. Six months later, the plasma, hippocampus, and cortex were processed to determine whether the behavioral effects were associated with long-term alterations in the metabolic pathways. Results In the open field without and with objects, interactions were observed for radiation × HU. In the plasma of animals that were not under the HU or control HU condition, the riboflavin metabolic pathway was affected most for sham irradiation vs. 0.75 Gy exposure. Analysis of the effects of control HU on plasma in the sham-irradiated animals showed that the alanine, aspartate, glutamate, riboflavin, and glutamine metabolisms as well as arginine biosynthesis were affected. The effects of control HU on the hippocampus in the sham-irradiated animals showed that the phenylalanine, tyrosine, and tryptophan pathway was affected the most. Analysis of effects of 0.75 Gy irradiation on the cortex of control HU animals showed that the glutamine and glutamate metabolic pathway was affected similar to the hippocampus, while the riboflavin pathway was affected in animals that were not under the control HU condition. The effects of control HU on the cortex in sham-irradiated animals showed that the riboflavin metabolic pathway was affected. Animals receiving 0.75 Gy of irradiation showed impaired glutamine and glutamate metabolic pathway, whereas animals receiving 1.5 Gy of irradiation showed impaired riboflavin metabolic pathways. A total of 21 plasma metabolites were correlated with the behavioral measures, indicating that plasma and brain biomarkers associated with behavioral performance are dependent on the environmental conditions experienced. Discussion Phenylalanine, tyrosine, and tryptophan metabolism as well as phenylalanine and tryptophan as plasma metabolites are biomarkers that can be considered for spaceflight as they were revealed in both Fischer and WAG/Rij rats exposed to simGCRsim and/or HU.

Physiology↗

The Relationship Between Perceived Control and Hypothalamic–Pituitary–Adrenal Axis Reactivity to the Trier Social Stress Test in Healthy Young Adults

Psychological factors can modulate the hypothalamic–pituitary–adrenal (HPA) axis activity toward stressors. Animal studies demonstrated that uncontrollability was one critical factor associated with HPA axis stress response, but the results in human studies were inconsistent. The current study adopted a standardized laboratory stress induction procedure, the Trier Social Stress Test (the TSST), as the stressor to regulate the objective controllability level, and young adult participants were asked to rate their subjectively perceived control level toward the stressor and measured their cortisol stress responses ( N =54; 19 females and 35 males) to address this concern. Results showed that participants’ perceived control on the TSST was related to the cortisol stress response. In other words, under the stress of a certain objective controllability level, the lower the subjectively perceived control level, the greater the HPA axis response. This finding suggested that, in addition to objective controllability, subjectively perceived control is a psychological factor that regulates activation of the HPA axis in young adults.

Liu, Qian↗

LED lamp color control system and method

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

47 OTHER INSTRUMENTATION↗

Systems and methods for providing power to a load based upon a control strategy

Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

42 ENGINEERING↗

Feedwater temperature control methods and systems

A system for controlling the power level of a natural circulation boiling water nuclear reactor (NCBWR) is disclosed. The system, in accordance with an example embodiment of the present invention, may include a controller configured to control a power output level of the NCBWR by controlling a heating subsystem to adjust a temperature of feedwater flowing into an annulus of the NCBWR. The heating subsystem may include a steam diversion line configured to receive steam generated by a core of the NCBWR and a steam bypass valve configured to receive commands from the controller to control a flow of the steam in the steam diversion line, wherein the steam received by the steam diversion line has not passed through a turbine. Additional embodiments of the invention may include a feedwater bypass valve for controlling an amount of flow of the feedwater through a heater bypass line to the annulus.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control Strategies for Electric Vehicle (EV) Charging Using Renewables and Local Storage

The increase of electric vehicle (EV) and plug-in hybrid-electric vehicle (PHEV) adoption creates a need for more EV supply equipment (EVSE) infrastructure (i.e., EV chargers). The impact of EVSE installations could be significant due to limitations in the electric grid and potential demand charges for residential and commercial customers. The use of renewables (e.g., solar) and local storage (e.g., battery bank) can mitigate loads caused by EVSE on the electric grid. This would eliminate costly upgrades needed by utilities and decrease demand charges for consumers. This paper aims to explore control systems that mitigate the impact of EVSE on the electric grid using solar energy and battery banks. Three control systems are investigated and compared in this study. The first control system discharges the battery bank at a constant rate during specific times of the day based on historical data. The second discharges the battery bank based on the number of EVs charging (linear) and the amount of solar energy being generated. The third discharges the battery bank based on a sigmoid function (non-linear) in response to the number of EVs charging, and also takes into consideration the amount of renewables being generated. The first and second control systems recharge the battery bank at night when demand charges are lowest. The third recharges the battery bank at night and during times of the day when there is an excess of solar. Experiments are conducted using data from a private site that has 25 solar-assisted charging stations at Oak Ridge National Laboratory (ORNL) in Oak Ridge, TN and 4 at a public site in Nashville, TN. Results indicate the third control system having better performance, negating up to 71% of EVSE load, compared with the second control system (up to 61%) and the first control system (up to 58%).

Castello, Charles C↗

Adaptive powertrain control for plugin hybrid electric vehicles

A powertrain control system for a plugin hybrid electric vehicle. The system comprises an adaptive charge sustaining controller; at least one internal data source connected to the adaptive charge sustaining controller; and a memory connected to the adaptive charge sustaining controller for storing data generated by the at least one internal data source. The adaptive charge sustaining controller is operable to select an operating mode of the vehicle's powertrain along a given route based on programming generated from data stored in the memory associated with that route. Further described is a method of adaptively controlling operation of a plugin hybrid electric vehicle powertrain comprising identifying a route being traveled, activating stored adaptive charge sustaining mode programming for the identified route and controlling operation of the powertrain along the identified route by selecting from a plurality of operational modes based on the stored adaptive charge sustaining mode programming.

33 ADVANCED PROPULSION SYSTEMS↗

Alternator control for battery charging

In accordance with an aspect of the present disclosure, an electrical system for an automotive vehicle has an electrical generating machine and a battery. A set point voltage, which sets an output voltage of the electrical generating machine, is set by an electronic control unit (ECU). The ECU selects one of a plurality of control modes for controlling the alternator based on an operating state of the vehicle as determined from vehicle operating parameters. The ECU selects a range for the set point voltage based on the selected control mode and then sets the set point voltage within the range based on feedback parameters for that control mode. In an aspect, the control modes include a trickle charge mode and battery charge current is the feedback parameter and the ECU controls the set point voltage within the range to maintain a predetermined battery charge current.

25 ENERGY STORAGE↗

Hydrodynamic Effects on Modeling and Control of a High Temperature Active Magnetic Bearing Pump with a Canned Rotor

Embedding instrumentation and control Embedding instrumentation and control (I\&C) at the component level in nuclear power plants can improve component performance, lifetime, and resilience by optimizing operation, reducing the constraints on physical design, and providing on-board prognostics and diagnostics. However, the extreme environments that many nuclear power plant components operate in makes embedding instrumentation and control at the component level difficult. Successfully utilizing embedded I\&C requires developing a deep understanding of the system's dynamics and using that knowledge to overcome material and physical limitations imposed by the environment. In this paper, we will develop a coupled dynamic model of a high temperature (700 $^\circ$C) canned rotor pump that incorporates rotordynamics, hydrodynamics, and active magnetic bearing dynamics. Then we will compare two control design methods, one that uses a simplified decoupled model of the system and another that utilizes the full coupled system model. It will be seen that utilizing all the available knowledge of the system dynamics in the controller design yield an order of magnitude improvement in the magnitude of the magnetic bearing response to disturbances at the same level of control effort, a large reduction in the settling time of the system, and a smoother control action.

Melin, Alexander M↗