Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Identification of human ferritin, heavy polypeptide 1 (FTH1) and yeast RGI1 (YER067W) as pro-survival sequences that counteract the effects of Bax and copper in Saccharomyces cerevisiae

Ferritin is a sub-family of iron binding proteins that form multi-subunit nanotype iron storage structures and prevent oxidative stress induced apoptosis. Here we describe the identification and characterization of human ferritin, heavy polypeptide 1 (FTH1) as a suppressor of the pro-apoptotic murine Bax sequence in yeast. In addition we demonstrate that FTH1 is a general pro-survival sequence since it also prevents the cell death inducing effects of copper when heterologously expressed in yeast. Although ferritins are phylogenetically widely distributed and are present in most species of Bacteria, Archaea and Eukarya, ferritin is conspicuously absent in most fungal species including Saccharomyces cerevisiae. An in silico analysis of the yeast proteome lead to the identification of the 161 residue RGI1 (YER067W) encoded protein as a candidate for being a yeast ferritin. In addition to sharing 20% sequence identity with the 183 residue FTH1, RGI1 also has similar pro-survival properties as ferritin when overexpressed in yeast. Analysis of recombinant protein by SDS-PAGE and by electron microscopy revealed the expected formation of higher-order structures for FTH1 that was not observed with Rgi1p. Further analysis revealed that cells overexpressing RGI1 do not show increased resistance to iron toxicity and do not have enhanced capacity to store iron. In contrast, cells lacking RGI1 were found to be hypersensitive to the toxic effects of iron. Overall, our results suggest that Rgi1p is a novel pro-survival protein whose function is not related to ferritin but nevertheless it may have a role in regulating yeast sensitivity to iron stress. - Highlights: • Human ferritin, heavy polypeptide 1 (FTH1) was identified as a suppressor of the pro-apoptotic Bax in yeast. • Based on its similarity to ferritin we examined Rgi1p/YER067W for potential ferritin like functions. • Like human H-ferritin, RGI1 confers increased resistance to apoptotic inducing stresses in yeast. • Rgi1p is a pro-survival protein that is not a ferritin but that may play a role in iron metabolism of yeast.

60 APPLIED LIFE SCIENCES↗

The adaptor protein alpha-syntrophin regulates adipocyte lipid droplet growth

The scaffold protein alpha-syntrophin (SNTA) regulates lipolysis indicating a role in lipid homeostasis. Adipocytes are the main lipid storage cells in the body, and here, the function of SNTA has been analyzed in 3T3-L1 cells. SNTA is expressed in preadipocytes and is induced early during adipogenesis. Knock-down of SNTA in preadipocytes increases their proliferation. Proteins which are induced during adipogenesis like adiponectin and caveolin-1, and the inflammatory cytokine IL-6 are at normal levels in the mature cells differentiated from preadipocytes with low SNTA. This suggests that SNTA does neither affect differentiation nor inflammation. Expression of proteins with a role in cholesterol and triglyceride homeostasis is unchanged. Consequently, basal and epinephrine induced lipolysis as well as insulin stimulated phosphorylation of Akt and ERK1/2 are normal. Importantly, adipocytes with low SNTA form smaller lipid droplets and store less triglycerides. Stearoyl-CoA reductase and MnSOD are reduced upon SNTA knock-down but do not contribute to lower lipid levels. Oleate uptake is even increased in cells with SNTA knock-down. In summary, current data show that SNTA is involved in the expansion of lipid droplets independent of adipogenesis. Enhanced preadipocyte proliferation and capacity to store surplus fatty acids may protect adipocytes with low SNTA from lipotoxicity in obesity. - Highlights: • Alpha-syntrophin (SNTA) is expressed in 3T3-L1adipocytes. • SNTA knock-down in preadipocytes has no effect on adipogenesis. • Mature 3T3-L1 differentiated from cells with low SNTA form small lipid droplets. • SCD1 and MnSOD are reduced in adipocytes with low SNTA. • SCD1 knock-down does not alter triglyceride levels.

60 APPLIED LIFE SCIENCES↗

Performance of the university of saskatchewan compact torus injector with curved acceleration electrodes

The first vertical compact torus (CT) injection experiment has been performed in the Saskatchewan Torus Modified (STOR-M) tokamak [Nucl. Fusion 46, 104 (2006)]. To increase the kinetic energy density of the injected CTs for deeper penetration, the University of Saskatchewan Compact Torus Injector (USCTI) was further modified by attaching a 90 deg. curved inner electrode coaxial with the outer electrode. The modification extended the original CT acceleration section from 60 to 114 cm. Effects of the curved acceleration electrodes on the velocity and magnetic field of the CT are reported in this paper. It has been found that the CTs, injected horizontally, were deflected to vertical direction and CT velocity measured at the curved acceleration section increased to 180 km/s, representing a 40% increase compared with the case without the curved inner electrode in a previous experiment. At a higher acceleration bank voltage of 16 kV, this velocity increased to about 270 km/s. In addition, amplification of the CT magnetic field in the curved acceleration section has also been observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak

Plasma experiments on KSTAR are scheduled to start up this year (2008). We have developed an electron cyclotron emission (ECE) radiometer to measure the radial electron temperature profiles in KSTAR experiments. The radiometer system consists, briefly, of two downconversion stages, amplifiers, bandpass filter banks, and video detectors. These components are made commercially or developed in house. The system detects ECE power in the frequency range from 110 to 196 GHz, the detected signal being resolved by means of 48 frequency windows. Before installation of this system on KSTAR, we installed a part of this system on large helical device (LHD) to study the system under similar plasma conditions. In this experiment, the signal amplitude, considered to be proportional to the electron temperature, is measured. The time-dependent traces of the electron temperature measured by this radiometer are in good agreement with those provided by the LHD Michelson spectrometer. The system noise level which limits the minimum measurable temperature (converted to the electron temperature) is about 30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Development of a Miniature Neutron Generator for the Brachytherapy Treatment of Cancer

Brachytherapy refers to application of an irradiation source within a tumor. {sup 252}Cf needles used in brachytherapy have been successfully applied to treatment of some of the most virulent cancers but it is doubtful that it will be widely used because of difficulty in dealing with unwanted dose (source cannot be turned off) and in adhering to stringent NRC regulations that have been exacerbated in our post 911 environment. We have been working on the development of a miniature neutron generator with the reaction target placed at the end of a needle (tube) for brachytherapy applications. Orifice geometries are most amenable, e.g. rectum and cervix, but interstitial use is possible with microsurgery. This paper dicusses the results of a 30 watt DD neutron generator SBU project that demonstrates that sufficient hydrogen isotope current can be delivered down a small diameter needle required for a DT neutron treatment device, and, will summarize the progress of building a commercial device pursued by the All Russian Institute for Automatics (VNIIA) supported by the DOE's Industrial Proliferation Prevention Program (IPP). It is known that most of the fast neutron (FN) beam cancer treatment facilities have been closed down. It appears that the major limitation in the use of FN beams has been damage to healthy tissue, which is relatively insensitive to photons, but this problem is alleviated by brachytherapy. Moreover, recent clinical results indicate that fast neutrons in the boost mode are most highly effective in treating large, hypoxic, and rapidly repopulating diseases. It appears that early boost application of FN may halt angiogenesis (development and repair of tumor vascular system) and shrink the tumor resulting in lower hypoxia. The boost brachytherapy application of a small, low cost neutron generator holds promise of significant contribution to the treatment of cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of the parameters of plasma liners with zero-dimensional models

The efficiency of conversion of the energy stored in the capacitor bank of a high-current pulse generator into the kinetic energy of an imploding plasma liner is analyzed. The analysis is performed by using a model consisting of LC circuit equations and equations of motion of a cylindrical shell. It is shown that efficient energy conversion can be attained only with a low-inductance generator. The mode of an 'ideal' load is considered where the load current at the final stage of implosion is close to zero. The advantages of this mode are, first, high efficiency of energy conversion (80%) and, second, improved stability of the shell implosion. In addition, for inertial confinement fusion realized by the scheme of a Z pinch dynamic hohlraum, not one but several fusion targets can be placed in the cavity on the pinch axis due to the large length of the liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First-cut design of an all-superconducting 100-T direct current magnet

A 100-T magnetic field has heretofore been available only in pulse mode. This first-cut design demonstrates that a 100-T DC magnet (100 T) is possible. We base our design on: Gadolinium-based coated superconductor; a nested-coil formation, each a stack of double-pancake coils with the no-insulation technique; a band of high-strength steel over each coil; and a 12-T radial-field limit. The 100 T, a 20 mm cold bore, 6-m diameter, 17-m height, with a total of 12 500-km long superconductor, stores an energy of 122 GJ at its 4.2-K operating current of 2400 A. It requires a 4.2-K cooling power of 300 W.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum money with classical verification

We propose and construct a quantum money scheme that allows verification through classical communication with a bank. This is the first demonstration that a secure quantum money scheme exists that does not require quantum communication for coin verification. Our scheme is secure against adaptive adversaries - this property is not directly related to the possibility of classical verification, nevertheless none of the earlier quantum money constructions is known to possess it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determinants of debit cards acceptance: An empirical investigation

These days, most of the Malaysians realize that the consumption of debit card will help them to reduce the household debt. Thus, it is important to analyse the acceptance of debit cards for further enhancement and expanding its market share in Malaysia. In addition, there is lacked of research being conducted on the determinants affecting the acceptance of debit cards among Malaysians. Thus, the study aimed to investigate the factors affecting the acceptance of debit cards. This study focuses on payment methods, consumer attitude, and safety of debit card in acceptance of debit cards. Questionnaires were distributed to the 300 respondents. The sampling procedure adopted was stratified random sampling. The data obtained were analysed using SPSS 20.0 which involves scale reliability, descriptive and regression analysis. The result indicates that payment methods, consumer attitude and safety are the determinants of debit cards acceptance. Safety is the best predictor as most of the customers are confidents to use debit cards because of the security being developed around these debit card transactions. The analyses presented in this study can be used by policymakers and managers as a guide to promote banking products and services. The findings achieved in this study will be of interest for practitioners and academics concerned with developments of the Malaysian banking industry.

99 GENERAL AND MISCELLANEOUS↗

Evaluating Kuala Lumpur stock exchange oriented bank performance with stochastic frontiers

Banks play an essential role in the economic development and banks need to be efficient; otherwise, they may create blockage in the process of development in any country. The efficiency of banks in Malaysia is important and should receive greater attention. This study formulated an appropriate stochastic frontier model to investigate the efficiency of banks which are traded on Kuala Lumpur Stock Exchange (KLSE) market during the period 2005–2009. All data were analyzed to obtain the maximum likelihood method to estimate the parameters of stochastic production. Unlike the earlier studies which use balance sheet and income statements data, this study used market data as the input and output variables. It was observed that banks listed in KLSE exhibited a commendable overall efficiency level of 96.2% during 2005–2009 hence suggesting minimal input waste of 3.8%. Among the banks, the COMS (Cimb Group Holdings) bank is found to be highly efficient with a score of 0.9715 and BIMB (Bimb Holdings) bank is noted to have the lowest efficiency with a score of 0.9582. The results also show that Cobb-Douglas stochastic frontier model with truncated normal distributional assumption is preferable than Translog stochastic frontier model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passivity analysis for a winged re-entry vehicle

Application of simple adaptive control (SAC) theory to the design of guidance and control systems for winged re-entry vehicles has been proven successful. To apply SAC to these non-linear and non-stationary systems, it needs to be Almost Strictly Passive (ASP), which is an extension of the Almost Strictly Positive Real (ASPR) condition for linear, time-invariant systems. To fulfill the ASP condition, the controlled, non-linear system has to be minimum-phase (i.e., the zero dynamics is stable), and there is a specific condition for the product of output and input matrix. Earlier studies indicate that even the linearised system is not ASPR. The two problems at hand are: 1) the system is non-minimum phase when flying with zero bank angle, and 2) whenever there is hybrid control, e.g., yaw control is established by combined reaction and aerodynamic control for the major part of flight, the second ASPR condition cannot be met. In this paper we look at both issues, the former related to the guidance system and the latter to the attitude-control system. It is concluded that whenever the nominal bank angle is zero, the passivity conditions can never be met, and guidance should be based on nominal commands and a redefinition of those whenever the error becomes too large. For the remaining part of the trajectory, the passivity conditions are marginally met, but it is proposed to add feedforward compensators to alleviate these conditions. The issue of hybrid control is avoided by redefining the controls with total control moments and adding a so-called control allocator. Deriving the passivity conditions for rotational motion, and evaluating these conditions along the trajectory shows that the (non-linear) winged entry vehicle is ASP. The sufficient conditions to apply SAC for attitude control are thus met.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Redox Trapping of Arsenic During Groundwater Discharge in Sediments from the Meghna Riverbank in Bangladesh

Groundwater arsenic (As) is elevated in the shallow Holocene aquifers of Bangladesh. In the dry season, the shallow groundwater discharges to major rivers. This process may influence the chemistry of the river and the hyporheic zone sediment. To assess the fate of As during discharge, surface (0-5 cm) and subsurface (1-3 m) sediment samples were collected at 9 sites from the bank of the Meghna River along a transect from its northern source (25 degrees N) to the Bay of Bengal (22.5 degrees N). Bulk As concentrations of surface sediment averaged 16 {+-} 7 mg/kg (n = 9). Subsurface sediment contained higher mean concentrations of As of 4,000 mg/kg (n = 14), ranging from 1 to 23,000 mg/kg As, with >100 mg/kg As measured at 8 sites. X-ray absorption near-edge structure spectroscopy indicated that As was mainly arsenate and arsenite, not As-bearing sulfides. We hypothesize that the elevated sediment As concentrations form as As-rich groundwater discharges to the river, and enters a more oxidizing environment. A significant portion of dissolved As sorbs to iron-bearing minerals, which form a natural reactive barrier. Recycling of this sediment-bound As to the Ganges-Brahmaputra-Meghna Delta aquifer provides a potential source of As to further contaminate groundwater. Furthermore, chemical fluxes from groundwater discharge from the Ganges-Brahmaputra-Meghna Delta may be less than previous estimates because this barrier can immobilize many elements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anomalies, unparticles, and Seiberg duality

We calculate triangle anomalies for fermions with noncanonical scaling dimensions. The most well-known example of such fermions (aka unfermions) occurs in Seiberg duality where the matching of anomalies (including mesinos with scaling dimensions between 3/2 and 5/2) is a crucial test of duality. By weakly gauging the nonlocal action for an unfermion, we calculate the one-loop three-current amplitude. Despite the fact that there are more graphs with more complicated propagators and vertices, we find that the calculation can be completed in a way that nearly parallels the usual case. We show that the anomaly factor for fermionic unparticles is independent of the scaling dimension and identical to that for ordinary fermions. This can be viewed as a confirmation that unparticle actions correctly capture the physics of conformal fixed point theories like Banks-Zaks or supersymmetric QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystallographic Evidence for Noncoplanar Catalytic Aspartic Acids in plasmepsin II Resides in the Protein Data Bank

The carboxylate atoms of the two catalytic aspartic acid residues in aspartic proteases are nearly coplanar and in the uncomplexed form share an in-plane nucleophilic water molecule that is central to the mechanism of these enzymes. This note reports that while reviewing the electron-density maps derived from the deposited data for uncomplexed plasmepsin II from Plasmodium falciparum (Asojo et al. (2003), J. Mol. Biol. 327, 173-181; PDB code 1lf4), it was discovered that the aspartic acid residues in this structure should in fact be distinctly noncoplanar. The crystallographic model from the deposited coordinates has been re-refined against the 1.9 {angstrom} resolution published diffraction data to an R{sub cryst} of 21.2% and an R{sub free} of 22.2%. The catalytic water molecule is present, but the plane of the carboxylate group of Asp214 is rotated by 66 degrees from its original position.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Curved Image-Plate Detector System for High-Resolution Synchrotron X-ray Diffraction

The developed curved image plate (CIP) is a one-dimensional detector which simultaneously records high-resolution X-ray diffraction (XRD) patterns over a 38.7 2{theta} range. In addition, an on-site reader enables rapid extraction, transfer and storage of X-ray intensity information in {le}30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X-ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X-ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high-temperature XRD.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron contamination modeling and reduction in a 1 T open bore inline MRI-linac system

Purpose: A potential side effect of inline MRI-linac systems is electron contamination focusing causing a high skin dose. In this work, the authors reexamine this prediction for an open bore 1 T MRI system being constructed for the Australian MRI-Linac Program. The efficiency of an electron contamination deflector (ECD) in purging electron contamination from the linac head is modeled, as well as the impact of a helium gas region between the deflector and phantom surface for lowering the amount of air-generated contamination. Methods: Magnetic modeling of the 1 T MRI was used to generate 3D magnetic field maps both with and without the presence of an ECD located immediately below the MLC’s. Forty-seven different ECD designs were modeled and for each the magnetic field map was imported into Geant4 Monte Carlo simulations including the linac head, ECD, and a 30 × 30 × 30 cm{sup 3} water phantom located at isocenter. For the first generation system, the x-ray source to isocenter distance (SID) will be 160 cm, resulting in an 81.2 cm long air gap from the base of the ECD to the phantom surface. The first 71.2 cm was modeled as air or helium gas, with the latter encased between two windows of 50 μm thick high density polyethlyene. 2D skin doses (at 70 μm depth) were calculated across the phantom surface at 1 × 1 mm{sup 2} resolution for 6 MV beams of field size of 5 × 5, 10 × 10, and 20 × 20 cm{sup 2}. Results: The skin dose was predicted to be of similar magnitude as the generic systems modeled in previous work, 230% to 1400% ofD {sub max} for 5 × 5 to 20 × 20 cm{sup 2}, respectively. Inclusion of the ECD introduced a nonuniformity to the MRI imaging field that ranged from ∼20 to ∼140 ppm while the net force acting on the ECD ranged from ∼151 N to ∼1773 N. Various ECD designs were 100% efficient at purging the electron contamination into the ECD magnet banks; however, a small percentage were scattered back into the beam and continued to the phantom surface. Replacing a large portion of the extended air-column between the ECD and phantom surface with helium gas is a key element as it significantly minimized the air-generated contamination. When using an optimal ECD and helium gas region, the 70 μm skin dose is predicted to increase moderately inside a small hot spot over that of the case with no magnetic field present for the jaw defined square beams examined here. These increases include from 12% to 40% of D {sub max} for 5 × 5 cm{sup 2}, 18% to 55% of D {sub max} for 10 × 10 cm{sup 2}, and from 23% to 65% of D {sub max} for 20 × 20 cm{sup 2}. Conclusions: Coupling an efficient ECD and helium gas region below the MLCs in the 160 cm isocenter MRI-linac system is predicted to ameliorate the impact electron contamination focusing has on skin dose increases. An ECD is practical as its impact on the MRI imaging distortion is correctable, and the mechanical forces acting on it manageable from an engineering point of view.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-86: Evaluation of the New RaySafe Unfors X2 Dosimetry System

Purpose: To evaluate the new RaySafe Unfors X2 (X2) dosimetry system and compare it to the operation of the RaySafe Unfors Xi (Xi) and Radcal Accugold (RCAG) dosimetry systems. The comparison was done for the radiographic/fluoroscopic detectors, mammography detectors and the CT ionization chambers. Methods: This study used several R/F rooms, GE AMX4 portable x-ray unit, Siemens Biograph 16 slice CT scanner and a Hologic Dimensions mammography unit to evaluate the dosimetry systems. The three X2 detectors were compared to similar detectors of the older Xi and RCAG detectors under clinical conditions used for diagnostic medical physics testing. Measurements of kVp, HVL and exposure were made under identical conditions. Results: For radiography and fluoroscopy the three systems agreed to within +2 kVp in the 60 to 140 kVp range, HVL measurements agreed to within +2 mm Al and the exposures agreed to within +5%. The RCAG 6 cc ionization chamber measured at least 3% higher than the diode systems. The X2 R/F detector appeared to be transparent to the fluoroscopy AEC system. For exposures made using both the CT ACR dose phantoms, the X2 agreed to within +3% of the other two systems. For mammography measurements, the three systems agreed to within +0.4kVp (25-49 kVp range), HVL measurements agreed to within +0.05 mm Al and the exposures agreed to within +1% of the ionization chamber. Conclusion: The X2 system is a new version of the older Xi system. The system is faster, more robust, very easy to use, has a larger dynamic range, produced less errors and stores 1000 exposures. The measurements showed that the system performs well in the clinical environment and the X2 is within + 5% agreement of the other two calibrated systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-120: Analytic Dose Verification for Patient-Specific Proton Pencil Beam Scanning Plans

Purpose: To independently verify the QA dose of proton pencil beam scanning (PBS) plans using an analytic dose calculation model. Methods: An independent proton dose calculation engine is created using the same commissioning measurements as those employed to build our commercially available treatment planning system (TPS). Each proton PBS plan is exported from the TPS in DICOM format and calculated by this independent dose engine in a standard 40 x 40 x 40 cm water tank. This three-dimensional dose grid is then compared with the QA dose calculated by the commercial TPS, using standard Gamma criterion. A total of 18 measured pristine Bragg peaks, ranging from 100 to 226 MeV, are used in the model. Intermediate proton energies are interpolated. Similarly, optical properties of the spots are measured in air over 15 cm upstream and downstream, and fitted to a second-order polynomial. Multiple Coulomb scattering in water is approximated analytically using Preston and Kohler formula for faster calculation. The effect of range shifters on spot size is modeled with generalized Highland formula. Note that the above formulation approximates multiple Coulomb scattering in water and we therefore chose not use the full Moliere/Hanson form. Results: Initial examination of 3 patient-specific prostate PBS plans shows that agreement exists between 3D dose distributions calculated by the TPS and the independent proton PBS dose calculation engine. Both calculated dose distributions are compared with actual measurements at three different depths per beam and good agreements are again observed. Conclusion: Results here showed that 3D dose distributions calculated by this independent proton PBS dose engine are in good agreement with both TPS calculations and actual measurements. This tool can potentially be used to reduce the amount of different measurement depths required for patient-specific proton PBS QA.

60 APPLIED LIFE SCIENCES↗