Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Fractionation in Stereotactic Body Radiation Therapy Using the Linear Quadratic Model

Purpose: To examine the fractionation effect of stereotactic body radiation therapy with a heterogeneous dose distribution. Methods: Derived from the linear quadratic formula with measurements from a hypothetical 2-cm radiosurgical tumor, the threshold percentage was defined as (α/β{sub tissue}/α/β{sub tumor}), the balance α/β ratio was defined as (prescription dose/tissue tolerance*α/β{sub tumor}), and the balance dose was defined as (tissue tolerance/threshold percentage). Results: With increasing fractions and equivalent peripheral dose to the target, the biological equivalent dose of “hot spots” in a target decreases. The relative biological equivalent doses of serial organs decrease only when the relative percentage of its dose to the prescription dose is above the threshold percentage. The volume of parallel organs at risk decreases only when the tumor's α/β ratio is above the balance α/β ratio and the prescription dose is lower than balance dose. Conclusions: The potential benefits of fractionation in stereotactic body radiation therapy depend on the complex interplay between the total dose, α/β ratios, and dose differences between the target and the surrounding normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Arc Reduces Range Uncertainty Effects and Improves Conformality Compared With Photon Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer

Purpose: To describe, in a setting of non-small cell lung cancer (NSCLC), the theoretical dosimetric advantages of proton arc stereotactic body radiation therapy (SBRT) in which the beam penumbra of a rotating beam is used to reduce the impact of range uncertainties. Methods and Materials: Thirteen patients with early-stage NSCLC treated with proton SBRT underwent repeat planning with photon volumetric modulated arc therapy (Photon-VMAT) and an in-house-developed arc planning approach for both proton passive scattering (Passive-Arc) and intensity modulated proton therapy (IMPT-Arc). An arc was mimicked with a series of beams placed at 10° increments. Tumor and organ at risk doses were compared in the context of high- and low-dose regions, represented by volumes receiving >50% and <50% of the prescription dose, respectively. Results: In the high-dose region, conformality index values are 2.56, 1.91, 1.31, and 1.74, and homogeneity index values are 1.29, 1.22, 1.52, and 1.18, respectively, for 3 proton passive scattered beams, Passive-Arc, IMPT-Arc, and Photon-VMAT. Therefore, proton arc leads to a 30% reduction in the 95% isodose line volume to 3-beam proton plan, sparing surrounding organs, such as lung and chest wall. For chest wall, V30 is reduced from 21 cm{sup 3} (3 proton beams) to 11.5 cm{sup 3}, 12.9 cm{sup 3}, and 8.63 cm{sup 3} (P=.005) for Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. In the low-dose region, the mean lung dose and V20 of the ipsilateral lung are 5.01 Gy(relative biological effectiveness [RBE]), 4.38 Gy(RBE), 4.91 Gy(RBE), and 5.99 Gy(RBE) and 9.5%, 7.5%, 9.0%, and 10.0%, respectively, for 3-beam, Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. Conclusions: Stereotactic body radiation therapy with proton arc and Photon-VMAT generate significantly more conformal high-dose volumes than standard proton SBRT, without loss of coverage of the tumor and with significant sparing of nearby organs, such as chest wall. In addition, both proton arc approaches spare the healthy lung from low-dose radiation relative to photon VMAT. Our data suggest that IMPT-Arc should be developed for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Tumor Size on Outcomes After Stereotactic Body Radiation Therapy for Medically Inoperable Early-Stage Non-Small Cell Lung Cancer

Purpose: Stereotactic body radiation therapy for medically inoperable early-stage non-small cell lung cancer (NSCLC) offers excellent control rates. Most published series deal mainly with small (usually <4 cm), peripheral, solitary tumors. Larger tumors are associated with poorer outcomes (ie, lower control rates, higher toxicity) when treated with conventional RT. It is unclear whether SBRT is sufficiently potent to control these larger tumors. We therefore evaluated and examined the influence of tumor size on treatment outcomes after SBRT. Methods and Materials: Between October 2004 and October 2010, 185 medically inoperable patients with early (T1-T2N0M0) NSCLC were treated on a prospective research ethics board-approved single-institution protocol. Prescription doses were risk-adapted based on tumor size and location. Follow-up included prospective assessment of toxicity (as per Common Terminology Criteria for Adverse Events, version 3.0) and serial computed tomography scans. Patterns of failure, toxicity, and survival outcomes were calculated using Kaplan-Meier method, and the significance of tumor size (diameter, volume) with respect to patient, treatment, and tumor factors was tested. Results: Median follow-up was 15.2 months. Tumor size was not associated with local failure but was associated with regional failure (P=.011) and distant failure (P=.021). Poorer overall survival (P=.001), disease-free survival (P=.001), and cause-specific survival (P=.005) were also significantly associated with tumor size (with tumor volume more significant than diameter). Gross tumor volume and planning target volume were significantly associated with grade 2 or worse radiation pneumonitis. However, overall rates of grade ≥3 pneumonitis were low and not significantly affected by tumor or target size. Conclusions: Currently employed stereotactic body radiation therapy dose regimens can provide safe effective local therapy even for larger solitary NSCLC tumors (up to 5.7 cm in tumor diameter or 100 cm{sup 3} in tumor volume) but are associated with more nonlocal failures as well as poorer survival. These observations suggest these patients may benefit from more extensive staging or consideration of adjuvant therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Ablative Body Radiation Therapy for Primary Kidney Cancer: A 3-Dimensional Conformal Technique Associated With Low Rates of Early Toxicity

Purpose: To describe our 3-dimensional conformal planning approaches and report early toxicities with stereotactic body radiation therapy for the management of primary renal cell carcinoma. Methods and Materials: This is an analysis of a phase 1 trial of stereotactic body radiation therapy for primary inoperable renal cell carcinoma. A dose of 42 Gy/3 fractions was prescribed to targets ≥5 cm, whereas for <5 cm 26 Gy/1 fraction was used. All patients underwent a planning 4-dimensional CT to generate a planning target volume (PTV) from a 5-mm isotropic expansion of the internal target volume. Planning required a minimum of 8 fields prescribing to the minimum isodose surrounding the PTV. Intermediate dose spillage at 50% of the prescription dose (R50%) was measured to describe the dose gradient. Early toxicity (<6 months) was scored using the Common Terminology Criteria for Adverse Events (v4.0). Results: From July 2012 to August 2013 a total of 20 patients (median age, 77 years) were recruited into a prospective clinical trial. Eleven patients underwent fractionated treatment and 9 patients a single fraction. For PTV targets <100 cm{sup 3} the median number of beams used was 8 (2 noncoplanar) to achieve an average R50% of 3.7. For PTV targets >100 cm{sup 3} the median beam number used was 10 (4 noncoplanar) for an average R50% value of 4.3. The R50% was inversely proportional to decreasing PTV volume (r=−0.62, P=.003) and increasing total beams used (r=−0.51, P=.022). Twelve of 20 patients (60%) suffered grade ≤2 early toxicity, whereas 8 of 20 patients (40%) were asymptomatic. Nausea, chest wall pain, and fatigue were the most common toxicities reported. Conclusion: A 3-dimensional conformal planning technique of 8-10 beams can be used to deliver highly tolerable stereotactic ablation to primary kidney targets with minimal early toxicities. Ongoing follow-up is currently in place to assess long-term toxicities and cancer control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Results of the UCSF-LBNL Randomized Trial: Charged Particle With Helium Ion Versus Iodine-125 Plaque Therapy for Choroidal and Ciliary Body Melanoma

Purpose: Relevant clinical data are needed given the increasing national interest in charged particle radiation therapy (CPT) programs. Here we report long-term outcomes from the only randomized, stratified trial comparing CPT with iodine-125 plaque therapy for choroidal and ciliary body melanoma. Methods and Materials: From 1985 to 1991, 184 patients met eligibility criteria and were randomized to receive particle (86 patients) or plaque therapy (98 patients). Patients were stratified by tumor diameter, thickness, distance to disc/fovea, anterior extension, and visual acuity. Tumors close to the optic disc were included. Local tumor control, as well as eye preservation, metastases due to melanoma, and survival were evaluated. Results: Median follow-up times for particle and plaque arm patients were 14.6 years and 12.3 years, respectively (P=.22), and for those alive at last follow-up, 18.5 and 16.5 years, respectively (P=.81). Local control (LC) for particle versus plaque treatment was 100% versus 84% at 5 years, and 98% versus 79% at 12 years, respectively (log rank: P=.0006). If patients with tumors close to the disc (<2 mm) were excluded, CPT still resulted in significantly improved LC: 100% versus 90% at 5 years and 98% versus 86% at 12 years, respectively (log rank: P=.048). Enucleation rate was lower after CPT: 11% versus 22% at 5 years and 17% versus 37% at 12 years, respectively (log rank: P=.01). Using Cox regression model, likelihood ratio test, treatment was the most important predictor of LC (P=.0002) and eye preservation (P=.01). CPT was a significant predictor of prolonged disease-free survival (log rank: P=.001). Conclusions: Particle therapy resulted in significantly improved local control, eye preservation, and disease-free survival as confirmed by long-term outcomes from the only randomized study available to date comparing radiation modalities in choroidal and ciliary body melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer Tumors Greater Than 5 cm: Safety and Efficacy

Purpose: The purpose of this study was to determine outcomes of patients with node-negative medically inoperable non-small cell lung cancer (NSCLC) whose primary tumors exceeded 5 cm and were treated with stereotactic body radiation therapy (SBRT). Methods and Materials: We surveyed our institutional prospective lung SBRT registry to identify treated patients with tumors >5 cm. Treatment outcomes for local control (LC), locoregional control (LRC), disease-free survival (DFS), and overall survival (OS) were assessed by Kaplan-Meier estimates. Toxicities were graded according to Common Terminology Criteria for Adverse Events version 4. Mean pretreatment pulmonary function test values were compared to mean posttreatment values. Results: From December 2003 to July 2014, 40 patients met study criteria. Median follow-up was 10.8 months (range: 0.4-70.3 months). Median age was 76 years (range: 56-90 years), median body mass index was 24.3 (range: 17.7-37.2), median Karnofsky performance score was 80 (range: 60-90), and median Charlson comorbidity index score was 2 (range: 0-5). Median forced expiratory volume in 1 second (FEV1) was 1.41 L (range: 0.47-3.67 L), and median diffusion capacity (DLCO) was 47% of predicted (range: 29%-80%). All patients were staged by fluorodeoxyglucose-positron emission tomography/computed tomography staging, and 47.5% underwent mediastinal staging by endobronchial ultrasonography. Median tumor size was 5.6 cm (range: 5.1-10 cm), median SBRT dose was 50 Gy (range: 30-60 Gy) in 5 fractions (range: 3-10 fractions). Eighteen-month LC, LRC, DFS, and OS rates were 91.2%, 64.4%, 34.6%, and 59.7%, respectively. Distant failure was the predominant pattern of failure (32.5%). Three patients (7.5%) experienced grade 3 or higher toxicity. Mean posttreatment FEV1 was not significantly reduced (P=.51), but a statistically significant absolute 6.5% (P=.03) reduction in DLCO was observed. Conclusions: Lung SBRT for medically inoperable node-negative NSCLC with primary tumors larger than 5 cm is safe and provides excellent local control with limited toxicity. The predominant pattern of failure in this population was distant failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy

Purpose: To investigate development of a recipe for the creation of a beam angle class solution (CS) for noncoplanar prostate stereotactic body radiation therapy to replace time-consuming individualized beam angle selection (iBAS) without significant loss in plan quality, using the in-house “Erasmus-iCycle” optimizer for fully automated beam profile optimization and iBAS. Methods and Materials: For 30 patients, Erasmus-iCycle was first used to generate 15-, 20-, and 25-beam iBAS plans for a CyberKnife equipped with a multileaf collimator. With these plans, 6 recipes for creation of beam angle CSs were investigated. Plans of 10 patients were used to create CSs based on the recipes, and the other 20 to independently test them. For these tests, Erasmus-iCycle was also used to generate intensity modulated radiation therapy plans for the fixed CS beam setups. Results: Of the tested recipes for CS creation, only 1 resulted in 15-, 20-, and 25-beam noncoplanar CSs without plan deterioration compared with iBAS. For the patient group, mean differences in rectum D{sub 1cc}, V{sub 60GyEq}, V{sub 40GyEq}, and D{sub mean} between 25-beam CS plans and 25-beam plans generated with iBAS were 0.2 ± 0.4 Gy, 0.1% ± 0.2%, 0.2% ± 0.3%, and 0.1 ± 0.2 Gy, respectively. Differences between 15- and 20-beam CS and iBAS plans were also negligible. Plan quality for CS plans relative to iBAS plans was also preserved when narrower planning target volume margins were arranged and when planning target volume dose inhomogeneity was decreased. Using a CS instead of iBAS reduced the computation time by a factor of 14 to 25, mainly depending on beam number, without loss in plan quality. Conclusions: A recipe for creation of robust beam angle CSs for robotic prostate stereotactic body radiation therapy has been developed. Compared with iBAS, computation times decreased by a factor 14 to 25. The use of a CS may avoid long planning times without losses in plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Longitudinal Assessment of Quality of Life for Liver Cancer Patients Treated With Stereotactic Body Radiation Therapy

Purpose: To evaluate quality of life (QoL), an important outcome owing to poor long-term survival, after stereotactic body radiation therapy (SBRT) to the liver. Methods and Materials: Patients (n=222) with hepatocellular carcinoma (HCC), liver metastases, or intrahepatic cholangiocarcinoma and Child-Pugh A liver function received 24-60 Gy of 6-fraction image-guided SBRT. Prospective QoL assessment was completed with the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core-30 (QLQ-C30) and/or Functional Assessment of Cancer Therapy-Hepatobiliary (FACT-Hep, version 4) questionnaires at baseline and 1, 3, 6, and 12 months after treatment. Ten HCC patients with Child-Pugh B liver function were also treated. Results: The QLQ-C30 was available for 205 patients, and 196 completed the FACT-Hep. No difference in baseline QoL (P=.17) or overall survival (P=.088) was seen between the HCC, liver metastases, and intrahepatic cholangiocarcinoma patients. Appetite loss and fatigue measured by the QLQ-C30 clinically and statistically worsened by 1 month after treatment but recovered by 3 months. At 3 and 12 months after treatment, respectively, the FACT-Hep score had improved relative to baseline in 13%/19%, worsened in 36%/27%, and remained stable in 51%/54%. Using the QLQ-C30 Global Health score, QoL improved in 16%/23%, worsened in 34%/39%, and remained stable in 50%/38% at 3 and 12 months, respectively. Median survival was 17.0 months (95% confidence interval [CI] 12.3-19.8 months). Higher baseline scores on both FACT-Hep and QLQ-C30 Global Health were associated with improved survival. Hazard ratios for death, per 10-unit decrease in QoL, were 0.90 (95% CI 0.83-0.98; P=.001) and 0.88 (95% CI 0.82-0.95; P=.001), respectively. Tumor size was inversely correlated with survival. Conclusions: Liver SBRT temporarily worsens appetite and fatigue, but not overall QoL. Stereotactic body radiation therapy is well tolerated and warrants comparison against other liver-directed therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Trial of Stereotactic Body Radiation Therapy for Both Operable and Inoperable T1N0M0 Non-Small Cell Lung Cancer: Japan Clinical Oncology Group Study JCOG0403

Purpose: To evaluate, in Japan Clinical Oncology Group study 0403, the safety and efficacy of stereotactic body radiation therapy (SBRT) in patients with T1N0M0 non-small cell lung cancer (NSCLC). Methods and Materials: Eligibility criteria included histologically or cytologically proven NSCLC, clinical T1N0M0. Prescribed dose was 48 Gy at the isocenter in 4 fractions. The primary endpoint was the percent (%) 3-year overall survival. The threshold % 3-year survival to be rejected was set at 35% for inoperable patients, whereas the expected % 3-year survival was 80% for operable patients. Results: Between July 2004 and November 2008, 169 patients from 15 institutions were registered. One hundred inoperable and 64 operable patients (total 164) were eligible. Patients' characteristics were 122 male, 47 female; median age 78 years (range, 50-91 years); adenocarcinomas, 90; squamous cell carcinomas, 61; others, 18. Of the 100 inoperable patients, the % 3-year OS was 59.9% (95% confidence interval 49.6%-68.8%). Grade 3 and 4 toxicities were observed in 10 and 2 patients, respectively. No grade 5 toxicity was observed. Of the 64 operable patients, the % 3-year OS was 76.5% (95% confidence interval 64.0%-85.1%). Grade 3 toxicities were observed in 5 patients. No grade 4 and 5 toxicities were observed. Conclusions: Stereotactic body radiation therapy for stage I NSCLC is effective, with low incidences of severe toxicity. This treatment can be considered a standard treatment for inoperable stage I NSCLC. This treatment is promising as an alternative to surgery for operable stage I NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness of Surgery, Stereotactic Body Radiation Therapy, and Systemic Therapy for Pulmonary Oligometastases

Introduction: Pulmonary oligometastases have conventionally been managed with surgery and/or systemic therapy. However, given concerns about the high cost of systemic therapy and improvements in local treatment of metastatic cancer, the optimal cost-effective management of these patients is unclear. Therefore, we sought to assess the cost-effectiveness of initial management strategies for pulmonary oligometastases. Methods and Materials: A cost-effectiveness analysis using a Markov modeling approach was used to compare average cumulative costs, quality adjusted life years (QALYs), and incremental cost-effectiveness ratios (ICERs) among 3 initial disease management strategies: video-assisted thoracic surgery (VATS) wedge resection, stereotactic body radiation therapy (SBRT), and systemic therapy among 5 different cohorts of patient disease: (1) melanoma; (2) non-small cell lung cancer adenocarcinoma without an EGFR mutation (NSCLC AC); (3) NSCLC with an EGFR mutation (NSCLC EGFRm AC); (4) NSCLC squamous cell carcinoma (NSCLC SCC); and (5) colon cancer. One-way sensitivity analyses and probabilistic sensitivity analyses were performed to analyze uncertainty with regard to model parameters. Results: In the base case, SBRT was cost effective for melanoma, with costs/net QALYs of $467,787/0.85. In patients with NSCLC, the most cost-effective strategies were SBRT for AC ($156,725/0.80), paclitaxel/carboplatin for SCC ($123,799/0.48), and erlotinib for EGFRm AC ($147,091/1.90). Stereotactic body radiation therapy was marginally cost-effective for EGFRm AC compared to erlotinib with an incremental cost-effectiveness ratio of $126,303/QALY. For colon cancer, VATS wedge resection ($147,730/2.14) was the most cost-effective strategy. Variables with the greatest influence in the model were erlotinib-associated progression-free survival (EGFRm AC), toxicity (EGFRm AC), cost of SBRT (NSCLC SCC), and patient utilities (all histologies). Conclusions: Video-assisted thoracic surgery wedge resection or SBRT can be cost-effective in select patients with pulmonary oligometastases, depending on histology, efficacy, and tolerability of treatment and patient preferences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Stereotactic Body Radiation Therapy Compared With Radiofrequency Ablation for Inoperable Colorectal Liver Metastases

Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account for model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Spinal Metastases in the Postoperative Setting: A Secondary Analysis of Mature Phase 1-2 Trials

Purpose: To evaluate the outcomes in patients treated on prospective phase 1-2 protocols with postoperative stereotactic body radiation therapy (SBRT) and identify the associated prognostic variables. Methods and Materials: Sixty-six patients with 69 tumors were treated with SBRT on prospective phase 1-2 studies for spinal metastases between 2002 and 2010. All patients underwent SBRT after spine surgery, which included laminectomy, vertebrectomy, or a combination of these techniques. Renal cell carcinoma was the most common histology represented (n=35, 53%) followed by sarcomas (n=13, 20%). Thirty-one patients (47%) were treated with prior conventional radiation to the spine (median dose 30 Gy). Patients were followed up with spinal magnetic resonance imaging (MRI) studies to determine the treated tumor control (TC). Pain and other symptom data were collected prospectively to determine treatment response and toxicity. Results: The median follow-up time was 30 months (range, 1-145 months) for all patients and 75 months for living patients (range, 6-145 months). The actuarial 1-year rate of TC was 85%, adjacent vertebral body control was 85%, and overall survival (OS) was 74% (median 29 months). On multivariate competing-risks analysis, sarcoma histology (subhazard ratio [SHR] = 2.38, 95% confidence interval [CI] 1.05-5.6, P=.04) and larger preoperative tumor volumes (SHR=1.01, 95% CI 1.0-1.01, P=.006) were significantly associated with worse TC. Karnofsky performance status was the only significant predictor for OS on multivariate analysis. There were no differences in TC between patients treated with different surgical techniques or different preoperative or postoperative Bilsky grades. There were no grade 3 or higher neurologic toxicities. Conclusion: This study represents a large series of prospective data available on patients treated with SBRT in the postoperative setting. The combination of surgery with SBRT can offer patients with metastatic disease to the spine the chance of durable tumor control with minimal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Stereotactic Body Radiation Therapy Before Orthotopic Liver Transplantation: Retrospective Evaluation of Pathologic Response and Outcomes

Purpose: To analyze the results of stereotactic body radiation therapy (SBRT) in patients with early-stage, localized hepatocellular carcinoma who underwent definitive orthotopic liver transplantation (OLT). Methods and Materials: The subjects of this retrospective report are 38 patients diagnosed with hepatocellular carcinoma who underwent SBRT per institutional phase 1 to 2 eligibility criteria, before definitive OLT. Pre-OLT radiographs were compared with pathologic gold standard. Analysis of treatment failures and deaths was undertaken. Results: With median follow-up of 4.8 years from OLT, 9 of 38 patients (24%) recurred, whereas 10 of 38 patients (26%) died. Kaplan-Meier estimates of 3-year overall survival and disease-free survival are 77% and 74%, respectively. Sum longest dimension of tumors was significantly associated with disease-free survival (hazard ratio 1.93, P=.026). Pathologic response rate (complete plus partial response) was 68%. Radiographic scoring criteria performed poorly; modified Response Evaluation Criteria in Solid Tumors produced highest concordance (κ = 0.224). Explants revealed viable tumor in 74% of evaluable patients. Treatment failures had statistically larger sum longest dimension of tumors (4.0 cm vs 2.8 cm, P=.014) and non–statistically significant higher rates of lymphovascular space invasion (44% vs 17%), cT2 disease (44% vs 21%), ≥pT2 disease (67% vs 34%), multifocal tumors at time of SBRT (44% vs 21%), and less robust mean α-fetoprotein response (−25 IU/mL vs −162 IU/mL). Conclusions: Stereotactic body radiation therapy before to OLT is a well-tolerated treatment providing 68% pathologic response, though 74% of explants ultimately contained viable tumor. Radiographic response criteria poorly approximate pathology. Our data suggest further stratification of patients according to initial disease burden and treatment response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗