Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Develop and test fuel cell powered on-site integrated total energy systems

On-going testing of an 11 cell, 10.7 in. x 14 in. stack (about 1 kW) reached 2600 hours on steady load. Nonmetallic cooling plates and an automated electrolyte replenishment system continued to perform well. A 10 cell, 10.7 in. x 14 in. stack was constructed with a modified electrolyte matrix configuration for the purpose of reducing cell IR loss. The desired effect was achieved, but the general cell performance level was irregular. Evaluation is continuing. Preparations for a long term 25 cell, 13 in. x 23 in. test stack (about 4 kW) approached completion. Start up in early May 1984 is expected.

Kaufman, A.↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of measurement conditions.

99 GENERAL AND MISCELLANEOUS↗

Towards Unlocking Insights from Logbooks Using AI

Electronic logbooks contain valuable information about activities and events concerning their associated particle accelerator facilities. However, the highly technical nature of logbook entries can hinder their usability and automation. As natural language processing (NLP) continues advancing, it offers opportunities to address various challenges that logbooks present. This work explores jointly testing a tailored Retrieval Augmented Generation (RAG) model for enhancing the usability of particle accelerator logbooks at institutes like DESY, BESSY, Fermilab, BNL, SLAC, LBNL, and CERN. The RAG model uses a corpus built on logbook contributions and aims to unlock insights from these logbooks by leveraging retrieval over facility datasets, including discussion about potential multimodal sources. Our goals are to increase the FAIR-ness (findability, accessibility, interoperability, and reusability) of logbooks by exploiting their information content to streamline everyday use, enable macro-analysis for root cause analysis, and facilitate problem-solving automation.

43 PARTICLE ACCELERATORS↗

An Automated Vehicle Fuel Economy Benefits Evaluation Framework Using Real-World Travel and Traffic Data

Increasing automation is a consistent development trend in the automobile industry. However, real-world evaluation of the operational and energy consumption differences between automated vehicles and comparable manually driven vehicles has been limited. This study helps fill the information gap by comparing the operation and fuel economy of vehicles in adaptive cruise control (ACC) and non-ACC modes based on large-scale field test data collected by Volvo Car Corporation (Volvo Cars) from vehicles traveling on the designated 'Drive Me' project road network in Gothenburg, Sweden. The test vehicles' travel data are classified by driving mode (ACC vs. non-ACC) and driving conditions, which refer to traffic speed and road grade in this study. The results from the data logging fleet are used to estimate the aggregate fuel consumption differences at the Drive Me road-network level for vehicles traveling in ACC vs. non-ACC mode based on appropriately weighting the total amount of travel that took place on the network under different driving conditions. At the ACC penetration levels observed in the field test data, vehicles tended to drive more smoothly in ACC mode than in non-ACC mode. The corresponding travel-weighted fuel consumption rate for vehicles in ACC mode was about 5%-7% lower than for vehicles in non-ACC mode when traveling at similar conditions. Sensitivity analyses impart confidence in this result, and in the future, the established evaluation framework could be used to objectively quantify potential on-road fuel consumption impacts from vehicles with even higher levels of automated driving capability.

33 ADVANCED PROPULSION SYSTEMS↗

Poster — Thur Eve — 40: Automated Quality Assurance for Remote-Afterloading High Dose Rate Brachytherapy

High dose rate (HDR) remote afterloading brachytherapy involves sending a small, high-activity radioactive source attached to a cable to different positions within a hollow applicator implanted in the patient. It is critical that the source position within the applicator and the dwell time of the source are accurate. Daily quality assurance (QA) tests of the positional and dwell time accuracy are essential to ensure that the accuracy of the remote afterloader is not compromised prior to patient treatment. Our centre has developed an automated, video-based QA system for HDR brachytherapy that is dramatically superior to existing diode or film QA solutions in terms of cost, objectivity, positional accuracy, with additional functionalities such as being able to determine source dwell time and transit time of the source. In our system, a video is taken of the brachytherapy source as it is sent out through a position check ruler, with the source visible through a clear window. Using a proprietary image analysis algorithm, the source position is determined with respect to time as it moves to different positions along the check ruler. The total material cost of the video-based system was under $20, consisting of a commercial webcam and adjustable stand. The accuracy of the position measurement is ±0.2 mm, and the time resolution is 30 msec. Additionally, our system is capable of robustly verifying the source transit time and velocity (a test required by the AAPM and CPQR recommendations), which is currently difficult to perform accurately.

07 ISOTOPE AND RADIATION SOURCES↗

Invite the Chaos Monkey: Test Effect Payloads for Tuning ICS Incident Response

In 2010, when Netflix moved their operational systems to the cloud, they developed a pseudo-random mechanism to cause deliberate outages and failures of key system elements to ensure that automated systems for detecting and remediating outages were mature and fully functional. This Chaos Monkey spawned an entire Simian Army designed to ensure system resilience and enable failure response before issues became outages. Through the DARPA RADICS program, Provatech, INL, and other researchers have developed a mechanism for creating controllable failures via Test Effect Payloads (TEPs) for Industrial Control Systems in order to enable an asset owner to tune network and process sensor technology, increase the effectiveness of incident response and remediation, and highlight areas where resilient technology could bring benefit to Operational Technology. This talk will explore what a TEP is, how to create a TEP, and suggest what a systematic system resilience plan using TEP’s might look like. We will also discuss how regulated entities might employ TEP’s in a compliant resilience strategy.

42 ENGINEERING↗

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards Unlocking Insights from Logbooks Using AI

Electronic logbooks contain valuable information about activities and events concerning their associated particle accelerator facilities. However, the highly technical nature of logbook entries can hinder their usability and automation. As natural language processing (NLP) continues advancing, it offers opportunities to address various challenges that logbooks present. This work explores jointly testing a tailored Retrieval Augmented Generation (RAG) model for enhancing the usability of particle accelerator logbooks at institutes like DESY, BESSY, Fermilab, BNL, SLAC, LBNL and CERN. The RAG model uses a corpus built on logbook contributions and aims to unlock insights from these logbooks by leveraging retrieval over facility datasets, including discussion about potential multimodal sources. Our goals are to increase the FAIR-ness (findability, accessibility, interoperability, and reusability) of logbooks by exploiting their information content to streamline everyday use, to enable macro-analysis for root cause analysis, and to facilitate problem-solving automation.

43 PARTICLE ACCELERATORS↗

Compact Simultaneous-beam Optical Strain Measurement System, Phase 5

Recent advances on the laser speckle strain measurement system under development at NASA Lewis Research Center have resulted in a compact, easy-to-use measurement package having many performance improvements over previous systems. NASA has developed this high performance optical strain measurement system for high temperature material testing applications. The system is based on I. Yamaguchi's two-beam speckle-shift strain measurement theory, and uses a new optical design that allows simultaneous recording of laser speckle patterns. This design greatly improves system response over previous implementations of the two-beam speckle-shift technique. The degree of immunity to transient rigid body motions is no longer dependent on the data transfer rate. The system automatically calculates surface strains at a frequency of about 5 Hz using a high speed digital signal processor in a personal computer. This system is fully automated, and can be operated remotely. This report describes the designs and methods used by the system, and shows low temperature strain test results obtained from small diameter tungsten-rhenium and palladium-chrome wires.

Lant, Christian T.↗

Automation of the Environmental Control and Life Support System

The objective of the Environmental Control and Life Support System (ECLSS) Advanced Automation Project is to recommend and develop advanced software for the initial and evolutionary Space Station Freedom (SSF) ECLS system which will minimize the crew and ground manpower needed for operations. Another objective includes capturing ECLSS design and development knowledge for future missions. This report summarizes our results from Phase I, the ECLSS domain analysis phase, which we broke down into three steps: 1) Analyze and document the baselined ECLS system, 2) envision as our goal an evolution to a fully automated regenerative life support system, built upon an augmented baseline, and 3) document the augmentations (hooks and scars) and advanced software systems which we see as necessary in achieving minimal manpower support for ECLSS operations. In addition, Phase I included development of an advanced software life cycle testing tools will be used in the development of the software. In this way, we plan in preparation for phase II and III, the development and integration phases, respectively. Automated knowledge acquisition, engineering, verification, and can capture ECLSS development knowledge for future use, develop more robust and complex software, provide feedback to the KBS tool community, and insure proper visibility of our efforts.

Dewberry, Brandon S.↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

60 APPLIED LIFE SCIENCES↗

Machine learning prediction of incidence of Alzheimer’s disease using large-scale administrative health data

Nationwide population-based cohort provides a new opportunity to build an automated risk prediction model based on individuals’ history of health and healthcare beyond existing risk prediction models. We tested the possibility of machine learning models to predict future incidence of Alzheimer’s disease (AD) using large-scale administrative health data. From the Korean National Health Insurance Service database between 2002 and 2010, we obtained de-identified health data in elders above 65 years (N = 40,736) containing 4,894 unique clinical features including ICD-10 codes, medication codes, laboratory values, history of personal and family illness and socio-demographics. To define incident AD we considered two operational definitions: “definite AD” with diagnostic codes and dementia medication (n = 614) and “probable AD” with only diagnosis (n = 2026). We trained and validated random forest, support vector machine and logistic regression to predict incident AD in 1, 2, 3, and 4 subsequent years. For predicting future incidence of AD in balanced samples (bootstrapping), the machine learning models showed reasonable performance in 1-year prediction with AUC of 0.775 and 0.759, based on “definite AD” and “probable AD” outcomes, respectively; in 2-year, 0.730 and 0.693; in 3-year, 0.677 and 0.644; in 4-year, 0.725 and 0.683. The results were similar when the entire (unbalanced) samples were used. Important clinical features selected in logistic regression included hemoglobin level, age and urine protein level. This study may shed a light on the utility of the data-driven machine learning model based on large-scale administrative health data in AD risk prediction, which may enable better selection of individuals at risk for AD in clinical trials or early detection in clinical settings.

97 MATHEMATICS AND COMPUTING↗

Machine learning-led semi-automated medium optimization reveals salt as key for flaviolin production in Pseudomonas putida

Although synthetic biology can produce valuable chemicals in a renewable manner, its progress is still hindered by a lack of predictive capabilities. Media optimization is a critical, and often overlooked, process which is essential to obtain the titers, rates and yields needed for commercial viability. Here, we present a molecule- and host-agnostic active learning process for media optimization that is enabled by a fast and highly repeatable semi-automated pipeline. Its application yielded 60% and 70% increases in titer, and 350% increase in process yield in three different campaigns for flaviolin production in Pseudomonas putida KT2440. Explainable Artificial Intelligence techniques pinpointed that, surprisingly, common salt (NaCl) is the most important component influencing production. The optimal salt concentration is very high, comparable to seawater and close to the limits that P. putida can tolerate. The availability of fast Design-Build-Test-Learn (DBTL) cycles allowed us to show that performance improvements for active learning are rarely monotonous. This work illustrates how machine learning and automation can change the paradigm of current synthetic biology research to make it more effective and informative, and suggests a cost-effective and underexploited strategy to facilitate the high titers, rates and yields essential for commercial viability.

59 BASIC BIOLOGICAL SCIENCES↗

Computational catalyst discovery: Active classification through myopic multiscale sampling

We report the recent boom in computational chemistry has enabled several projects aimed at discovering useful materials or catalysts. We acknowledge and address two recurring issues in the field of computational catalyst discovery. First, calculating macro-scale catalyst properties is not straightforward when using ensembles of atomic-scale calculations [e.g., density functional theory (DFT)]. We attempt to address this issue by creating a multi-scale model that estimates bulk catalyst activity using adsorption energy predictions from both DFT and machine learning models. The second issue is that many catalyst discovery efforts seek to optimize catalyst properties, but optimization is an inherently exploitative objective that is in tension with the explorative nature of early-stage discovery projects. In other words, why invest so much time finding a “best” catalyst when it is likely to fail for some other, unforeseen problem? We address this issue by relaxing the catalyst discovery goal into a classification problem: “What is the set of catalysts that is worth testing experimentally?” Here, we present a catalyst discovery method called myopic multiscale sampling, which combines multiscale modeling with automated selection of DFT calculations. It is an active classification strategy that seeks to classify catalysts as “worth investigating” or “not worth investigating” experimentally. Our results show an ~7–16 times speedup in catalyst classification relative to random sampling. These results were based on offline simulations of our algorithm on two different datasets: a larger, synthesized dataset and a smaller, real dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of antifouling surfaces using a method that employs mussel larvae settlement quantified by machine learning

Antifouling coating development requires extensive performance testing. Coatings that prevent aquatic larval settlement are of interest because many forms of macrofouling begin at the larval stage. However, field testing can be time consuming and poorly controlled. Herein is reported a screening tool, Settlement of Larvae Assay using Mussels (SLAM), for down-selecting materials prior to field testing. The method entails using a dense concentration of mussel larvae that are allowed to settle on submerged test surfaces. Settled larvae are then quantified to provide a measure of antifouling performance. The SLAM test differentiated coatings with only slight differences in formulation. To enable efficient quantification of dense larvae settlement, an automated counting method was developed that combines two analyses: a color thresholding identifies larvae clumps, and a machine learning algorithm identifies non-clumped larvae. Finally, this automated ‘hybrid’ approach rapidly quantifies settled larvae as effectively as manual counting but in a fraction of the time.

Mytilus↗