Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

An Estimate of Shallow, Low-Temperature Geothermal Resources of the United States: Preprint

Low-temperature geothermal resources in the United States potentially hold an enormous quantity of thermal energy, useful for direct use in residential, commercial and industrial applications such as space and water heating, greenhouse warming, pool heating, aquaculture, and low-temperature manufacturing processes. Several studies published over the past 40 years have provided assessments of the resource potential for multiple types of low-temperature geothermal systems (e.g. hydrothermal convection, hydrothermal conduction, and enhanced geothermal systems) with varying temperature ranges and depths. This paper provides a summary and additional analysis of these assessments of shallow (= 3 km), low-temperature (30-150 degrees C) geothermal resources in the United States, suitable for use in direct-use applications. This analysis considers six types of geothermal systems, spanning both hydrothermal and enhanced geothermal systems (EGS). We outline the primary data sources and quantitative parameters used to describe resources in each of these categories, and present summary statistics of the total resources available. In sum, we find that low-temperature hydrothermal resources and EGS resources contain approximately 8 million and 800 million TWh of heat-in-place, respectively. In future work, these resource potential estimates will be used for modeling of the technical and market potential for direct-use geothermal applications for the U.S. Department of Energy's Geothermal Vision Study.

15 GEOTHERMAL ENERGY↗

Communicating with residential electrical devices via a vehicle telematics unit

A method of communicating with residential electrical devices using a vehicle telematics unit includes receiving information identifying a residential electrical device to control; displaying in a vehicle one or more controlled features of the identified residential electrical device; receiving from a vehicle occupant a selection of the displayed controlled features of the residential electrical device; sending an instruction from the vehicle telematics unit to the residential electrical device via a wireless carrier system in response to the received selection; and controlling the residential electrical device using the sent instruction.

47 OTHER INSTRUMENTATION↗

Oxy-fired boiler unit and method of operating the same

An oxy-combustion boiler unit is disclosed which includes a furnace for combusting fuel and for emitting flue gas resulting from combustion. The furnace has first, second and third combustion zones, and an air separation unit for separating oxygen gas from air and providing a first portion of the separated oxygen to a first oxidant flow, a second portion to a second oxidant flow, and a third portion of the separated oxygen gas to the first, second, and third zones of the furnace. A controller can cause the separated oxygen gas to be distributed so that the first and second oxygen flows have a desired oxygen content, and so that the first, second, and third zones of the furnace receive a desired amount of oxygen based on a combustion zone stoichiometry control.

20 FOSSIL-FUELED POWER PLANTS↗

An Estimate of Shallow, Low-Temperature Geothermal Resources of the United States

Low-temperature geothermal resources in the United States potentially hold an enormous quantity of thermal energy, useful for direct use in residential, commercial and industrial applications such as space and water heating, greenhouse warming, pool heating, aquaculture, and low-temperature manufacturing processes. Several studies published over the past 40 years have provided assessments of the resource potential for multiple types of low-temperature geothermal systems (e.g. hydrothermal convection, hydrothermal conduction, and enhanced geothermal systems) with varying temperature ranges and depths. This paper provides a summary and additional analysis of these assessments of shallow (= 3 km), low-temperature (30-150 degrees C) geothermal resources in the United States, suitable for use in direct-use applications. This analysis considers six types of geothermal systems, spanning both hydrothermal and enhanced geothermal systems (EGS). We outline the primary data sources and quantitative parameters used to describe resources in each of these categories, and present summary statistics of the total resources available. In sum, we find that low-temperature hydrothermal resources and EGS resources contain approximately 8 million and 800 million TWh of heat-in-place, respectively. In future work, these resource potential estimates will be used for modeling of the technical and market potential for direct-use geothermal applications for the U.S. Department of Energy's Geothermal Vision Study.

15 GEOTHERMAL ENERGY↗

Space vehicle field unit and ground station system

A field unit and ground station may use commercial off-the-shelf (COTS) components and share a common architecture, where differences in functionality are governed by software. The field units and ground stations may be easy to deploy, relatively inexpensive, and be relatively easy to operate. A novel file system may be used where datagrams of a file may be stored across multiple drives and/or devices. The datagrams may be received out of order and reassembled at the receiving device.

33 ADVANCED PROPULSION SYSTEMS↗

An Introduction to Retail Electricity Choice in the United States

Retail electricity choice in the United States allows end-use customers (including industrial, commercial, and residential customers) to buy electricity from competitive retail suppliers. This brochure offers an overview of retail electricity choice in the United States, and its impact on prices and renewable energy procurement. It concludes with three lessons learned from the U.S. retail market experience that may serve as a reference for other countries and regions taking steps towards retail electricity market liberalization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Performance and Green Federal Buildings in the United States

This paper looks at recent development in high performance and green Federal buildings in the United States. Congressional legislation and executive orders from the President of the US drive most development of Federal building regulation in the United States. The US Department of Energy’s Federal Energy Management Program (FEMP) is responsible for writing rules for Federal building design that become part of the US Code of Federal Regulation (CFR). Two pieces of legislation and one executive order are the main drivers behind recent efforts. The requirements from these drivers are being incorporated into two parts of the Code of Federal Regulations. 10 CFR Part 433 addresses Federal buildings that are designated commercial or high-rise multi-family residential buildings, while 10 CFR Part 435, Subpart A address Federal buildings that are designated low-rise residential buildings. This paper discusses the development of these regulations.

Nasseri, Cyrus H.↗

A Forecast of Crude Oil Production from Carbon Dioxide Enhanced Oil Recovery in the United States through 2018

CO2 supply for enhanced oil recovery operations in the United States is expected to increase 64% between 2012 and 2018, from 3.3 BCFd to 5.4 BCFd. The CO2 utilization rate (URNet the amount of CO2 supplied per incremental barrel of crude oil produced) can be used to estimate crude oil production based on CO2 supply rate. Based on compiled historical data we estimate the following regional CO2 Utilization rates: Permian basin, 8,500 scf/bbl, Rocky mountain, 8,000 scf/bbl, Gulf Coast, 25,000 scf/bbl. Applying these rates to the regional forecast for CO2 supply we forecast production from CO2 EOR in the United States in 2018 will be 500,000 bpd.

GHG↗

Source localization using multiple units of a tight-pitched detector array

A system and method for determining a probability of the location of an illicit radiation source within an environment based on directional detectors. An embodiment includes a plurality of directional radiation detectors distributed about the environment and integrated with a processing unit adapted to determine the probability of the source location based on the radiation count data received from the plurality of detectors. The processing unit is further adapted to output information indicative of the location of the radiation source within the environment.

Vilim, Richard B.↗

An Overview of the United States Department of Energy's Nuclear Criticality Safety Program and Future Challenges

The United States (US) Department of Energy (DOE)/National Nuclear Security Administration (NNSA) Nuclear Criticality Safety Program (NCSP) was formally established in January 1998 as part of the Defense Nuclear Facility Safety Board (DNFSB) Recommendation 97-2 implementation plan. The NCSP was initially focused on seven NCSP tasks: Critical Experiments, Benchmarking, Analytical Methods, Nuclear Data, Training and Qualification, Information Preservation and Dissemination, and Applicable Ranges of Bounding Curves and Data. The first NCSP 5-year plan was published in August 1999. Now, more than 20 years later, NCSP continues to serve the United States and the nuclear criticality safety (NCS) community around five technical program elements (TPEs): Analytical Methods, Information Preservation and Dissemination, Integral Experiments, Nuclear Data, and Training and Education. NCSP has three chartered support groups, the Criticality Safety Support Group, the Nuclear Data Advisory Group, and the DOE Criticality Safety Coordinating Team, all of which provide technical advisement to the NCS community, to DOE, and to the NCSP manager. NCSP has a comprehensive mission and vision document that provides technical and budget priorities for TPE attributes and goals to ensure that the needs of the NCS community and DOE NCS are prioritized appropriately to meet the goals defined by the 1998 DNFSB recommendation. Like any DOE/NNSA program, NCSP faces significant challenges in the future that involves program funding, rising nuclear facility costs, aging critical assembly infrastructure, knowledge retention, and other issues. This paper discusses NCSP and provides some insights into these and other challenges moving into the future.

Bowen, Douglas G.↗

Preemptive cache management policies for processing units

A processing system includes at least one central processing unit (CPU) core, at least one graphics processing unit (GPU) core, a main memory, and a coherence directory for maintaining cache coherence. The at least one CPU core receives a CPU cache flush command to flush cache lines stored in cache memory of the at least one CPU core prior to launching a GPU kernel. The coherence directory transfers data associated with a memory access request by the at least one GPU core from the main memory without issuing coherence probes to caches of the at least one CPU core.

Kayiran, Onur↗

Mixed core processor unit

A method and apparatus for processing data. The data is sent to a processor unit comprising a group of neural cores, a group of digital processing cores, and a routing network connecting the group of digital processing cores. The data is processed in the processor unit to generate a result.

97 MATHEMATICS AND COMPUTING↗

Pilot-configurable information on a display unit

A small thin display unit that can be installed in the flight deck for displaying only flight crew-selected tactical information needed for the task at hand. The flight crew can select the tactical information to be displayed by means of any conventional user interface. Whenever the flight crew selects tactical information for display, the user interface sends a corresponding request for tactical information to a computer system. The computer system processes the request, including periodically retrieving measured current values or computing current values for the requested tactical parameters and returning those current tactical parameter values to the display unit for display.

Shafaat, Syed Tahir↗

A METHODOLOGY TO SUPPORT THE DEVELOPMENT OF A NEW STATE VISION FOR THE UNITED STATES NUCLEAR INDUSTRY

A new strategy in the way in which the United States nuclear power plants (NPPs) are operated, maintained, and supported is needed. One such strategy is to transform the NPP operating model through a business-driven approach that leverages technology to enable new capabilities that improve performance and reduce cost. This paper presents a methodology for developing an achievable yet transformative new state vision that ensures continued safe and efficient operations of the United States NPP fleet. This work builds on existing guidance and leverages previous research to comprehensively address both bottom-up (i.e., utility needs) and top-down (i.e., first principles) considerations important for developing a new state vision. The proposed methodology is intended to provide industry-wide guidance for developing a new state vision that leverages both the selected vendor’s capabilities in a way that meets the utility’s modernization goals while ensuring state-of-the-art systems engineering and human factors engineering principles are applied that promote overall plant safety, performance, and efficiency.

99 GENERAL AND MISCELLANEOUS↗

Effects on the Sustainable Development Goals of Wood Pellet Production in the Southeastern United States

Wood-based pellets produced in the southeastern United States (SE US) and shipped overseas for the generation of heat and power support achievement of several of the United Nation’s Sustainable Development Goals and their targets. If improperly implemented, pellet supply chains, like most energy technologies, can have negative impacts on water and air quality, biodiversity, and other ecosystem services. Cooperation between regional and local industry partners and local communities as well as readily accessible information on environmental and societal effects of the industry are important for addressing sustainability goals. Strengths of this supply chain include replacement of fossil coal with bioenergy; support for renewable energy goals; conservation of forests through sustainable, green economy jobs; and more efficient use of waste materials.

09 BIOMASS FUELS↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States: Preprint

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Contentious narratives and disinformation about nuclear weapons in strategic deterrence and competition: A SOCOM perspective. Part of Section: United States Special Operations Command (USSOCOM) in Emerging Strategic & Geopolitical Challenges: Operational Implications for US Combatant Commands

Russia’s “special military operation” in Ukraine demonstrates the challenge for strategic deterrence and competition of countering contentious narratives and disinformation about weapons of mass destruction (WMD) during conventional regional wars against a nucleararmed adversary. Moscow uses both tailored, contentious narratives and targeted disinformation about WMD in Ukraine to influence and disrupt local and global perceptions in support of its deterrence and competition objectives vis-à-vis the United States and NATO. Since December 2021, Moscow has made a focal point of chemical, biological, radiological, and nuclear weapons in its efforts to establish a permissive environment for its military buildup on the border with Ukraine and then its military intervention. These information tactics also demonstrate an opportunity for US Special Operations Forces (SOF). They are a case study for considering how SOF can contribute to strategic deterrence and competition objectives, specifically countering adversary gray-zone information efforts to alter regional security orders.1 Such a role is in line with the 2022 Special Operations Forces Vision and Strategy, which provides a framework for the evolution of SOF into “a force capable of creating strategic, asymmetric advantages for the nation as a key contributor of integrated deterrence” (United States Special Operations Command, 2022). This paper briefly examines this strategic challenge and SOF opportunity, focusing narrowly on the distinction between contentious narratives and disinformation about nuclear weapons and the role of SOF in countering these gray-zone information tactics. The nuclear dimension of Moscow’s contentious narratives and disinformation in the “special military operation” is of particular interest because it demonstrates the distinction between strategic efforts to influence and disrupt local and global perceptions in Moscow’s favor. This distinction between influence and disruption is less clear with Russia’s contentious narratives and disinformation about chemical and biological weapons in Ukraine, as disinformation about these two types of WMD appears to overwhelm contentious narratives. We believe this distinction is useful for policymakers and warfighters responsible for countering gray-zone information tactics because it provides a framework for crafting tailored responses to contentious narratives and disinformation about nuclear weapons and other WMD. The chapter concludes with a discussion of efforts that could be undertaken by SOF in cooperation with other relevant stakeholders to address this aspect of adversary gray-zone information tactics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗