Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Film Cooled Recession of SiC/SiC Ceramic Matrix Composites: Test Development, CFD Modeling and Experimental Observations

SiCSiC ceramic matrix composites (CMCs) systems will play a crucial role in next generation turbine engines for hot-section component applications because of their ability to significantly increase engine operating temperatures, reduce engine weight and cooling requirements. However, the environmental stability of Si-based ceramics in high pressure, high velocity turbine engine combustion environment is of major concern. The water vapor containing combustion gas leads to accelerated oxidation and corrosion of the SiC based ceramics due to the water vapor reactions with silica (SiO2) scales forming non-protective volatile hydroxide species, resulting in recession of the ceramic components. Although environmental barrier coatings are being developed to help protect the CMC components, there is a need to better understand the fundamental recession behavior of in more realistic cooled engine component environments.In this paper, we describe a comprehensive film cooled high pressure burner rig based testing approach, by using standardized film cooled SiCSiC disc test specimen configurations. The SiCSiC specimens were designed for implementing the burner rig testing in turbine engine relevant combustion environments, obtaining generic film cooled recession rate data under the combustion water vapor conditions, and helping developing the Computational Fluid Dynamics (CFD) film cooled models and performing model validation. Factors affecting the film cooled recession such as temperature, water vapor concentration, combustion gas velocity, and pressure are particularly investigated and modeled, and compared with impingement cooling only recession data in similar combustion flow environments. The experimental and modeling work will help predict the SiCSiC CMC recession behavior, and developing durable CMC systems in complex turbine engine operating conditions.

Recession↗

Consistent Practices for the Probability of Detection (POD) of Fracture Critical Metallic Components Project

NASA-STD-5009 requires that successful flaw detection by NDE methods be statistically qualified for use on fracture critical metallic components, but does not standardize practices. This task works towards standardizing calculations and record retention with a web-based tool, the NNWG POD Standards Library or NPSL. Test methods will also be standardized with an appropriately flexible appendix to -5009 identifying best practices. Additionally, this appendix will describe how specimens used to qualify NDE systems will be cataloged, stored and protected from corrosion, damage, or loss.

Hughitt, Brian↗

Data & Reasoning Fabric Minimum Viable Product

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users.

DRF↗

Framing Potential Wildfire Opportunities for DRF

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users.

Aeronautics↗

Data and Reasoning Fabric (DRF)

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users.

Aeronautics↗

Data and Reasoning Fabric (DRF)

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users. Presentation has a run time of 16:58 and is an mp4 attachment included in documents.

Aeronautics↗

Data and Reasoning Fabric (DRF)

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users.

Aeronautics↗

Data and Reasoning Fabric (DRF)

A Data & Reasoning Fabric (DRF) is envisioned to enable the full potential of air mobility by providing all data and reasoning where they are needed. The DRF provides a marketplace based on an open foundational ecosystem of data and reasoning exchange between the many systems that must seamlessly interplay to manage the complex and dense airspace operations required to achieve advanced air mobility goals. The DRF marketplace is decentralized and will not be owned by any single party. To deliver reference designs and development environments that catalyze broad private and public sector buy-in and self-sustaining development of DRF and associated standards, DRF activities will collaboratively test these technologies, open standards and architectures, and an integrated framework with end-users. (13.21 run time Video of presentation)

Aeronautics↗

Tevatron Measurements of Electroweak Boson Production

With a large and still increasing dataset, W and Z boson physics studies at the Tevatron p{bar p} collider are particularly useful for testing many aspects of the Standard Model. In this proceeding, we present measurements of electroweak boson properties, distributions, and charge asymmetries. We examine both solitary W and Z production as well as production in association with jets. These measurements are compared to NLO QCD predictions, are used to extract fundamental Standard Model parameters, and constrain parton distribution functions.

43 PARTICLE ACCELERATORS↗

NASA-STD-7012 Leak Test Requirements: Potential Reference for ASNT Nondestructive Testing Handbook for Leak Testing

Developed in 2018-2019, NASA-STD-7012 Leak Test Requirements, has been drafted based mostly on the NASA technical requirement documents applicable to the International Space Station (ISS) hardware and payloads that were developed over the years taking into consideration many known references such as Leakage Testing Handbook prepared by General Electric for the Jet Propulsion Laboratory, the ASTM International standards for leak testing, and last, but not least, the ASNT Nondestructive Testing Handbook for Leak Testing. Thus, NASA-STD-7012 has a reference to the above-mentioned handbook in the leak test method/technique descriptions. However, there are some technical details that are described differently in NASA standard and ASNT Handbook. Those technical details are mostly related to the classification of the leak test methods/techniques, and also to tracer gas to working fluid (gas or liquid) leakage rate conversion methodology, and to some definitions used in the text of both NASA standard and ASNT Handbook. Those differences are going to be briefly described in this paper to let ASNT leak test experts decide if they want to refer to NASA-STD-7012 while working on the next edition of the ASNT Handbook, Volume 2 for Leak Testing.

Lvovsky, Oleg M.↗

Three Dimensional Constraint Effects on the Estimated (Delta)CTOD during the Numerical Simulation of Different Fatigue Threshold Testing Techniques

Variation in constraint through the thickness of a specimen effects the cyclic crack-tip-opening displacement (DELTA CTOD). DELTA CTOD is a valuable measure of crack growth behavior, indicating closure development, constraint variations and load history effects. Fatigue loading with a continual load reduction was used to simulate the load history associated with fatigue crack growth threshold measurements. The constraint effect on the estimated DELTA CTOD is studied by carrying out three-dimensional elastic-plastic finite element simulations. The analysis involves numerical simulation of different standard fatigue threshold test schemes to determine how each test scheme affects DELTA CTOD. The American Society for Testing and Materials (ASTM) prescribes standard load reduction procedures for threshold testing using either the constant stress ratio (R) or constant maximum stress intensity (K(sub max)) methods. Different specimen types defined in the standard, namely the compact tension, C(T), and middle cracked tension, M(T), specimens were used in this simulation. The threshold simulations were conducted with different initial K(sub max) values to study its effect on estimated DELTA CTOD. During each simulation, the DELTA CTOD was estimated at every load increment during the load reduction procedure. Previous numerical simulation results indicate that the constant R load reduction method generates a plastic wake resulting in remote crack closure during unloading. Upon reloading, this remote contact location was observed to remain in contact well after the crack tip was fully open. The final region to open is located at the point at which the load reduction was initiated and at the free surface of the specimen. However, simulations carried out using the constant Kmax load reduction procedure did not indicate remote crack closure. Previous analysis results using various starting K(sub max) values and different load reduction rates have indicated DELTA CTOD is independent of specimen size. A study of the effect of specimen thickness and geometry on the measured DELTA CTOD for various load reduction procedures and its implication in the estimation of fatigue crack growth threshold values is discussed.

Seshadri, Banavara R.↗

Probing the role of solids loading and mix procedure on the properties of acoustically mixed materials for additive manufacturing

We report resonant acoustic mixing has been of particular interest for use in additive manufacturing since viscous, solids-loaded materials can be difficult to mix and inhomogeneity has adverse effects on print quality. In this study, we detail a method to iterate through different formulations and mix procedures and assess mixture quality. The approach utilizes a constant pressure-driven flow test to collect statistics on flow rate through a standard geometry. This test is first applied to well mixed formulations containing particulate solids and find that the results are sensitive to viscosity produced by solids content. We then consider the formulations at various stages of mixing and find that the spread in the volume measurements is indicative of the mixing quality; poorly mixed material yields measurements with wide distributions. We believe this testing approach can be useful when screening new formulations, developing mixing processes, or for quality control.

36 MATERIALS SCIENCE↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical and Mechanical Properties of Glass Blown In Vacuo

Theoretically, the strength of glass processed in vacuum should be higher due to outgassing of contaminants normally present in the glass, such as bulk water in the form of OH bonds that tends to weaken the glass structure. In this research, small discs of a few types of glass have been subjected to various temperatures for extended periods of time in vacuum. Their strength was then tested using a standard flexure technique, facilitated by a custom-designed test fixture, and the results were compared to glass tested in air using the same fixture. The purpose of the glass blowing investigation was to prove the basic feasibility of a high-level concept for in-space manufacture of optical elements. The central requirement was that the glass bubble had to be blown into a support structure such that the bubble could be handled by manipulation of the structure. The blown bubble attached itself to a mullite ring geometrically and mechanically, as a demonstration in the initial experiments described here, by expanding through and around it. The vacuum system used was custom made, as were most of the components of the system, such as the heating element, the glass and ring support structure, and the gas inlet system that provided the pressure needed to blow the glass.

Manning, andrew↗

Testing of flat conductor cable to Underwriters Laboratory standards UL719 and UL83

The flat conductor cable (FCC) which was tested consisted of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with a self-extinguishing polyester adhesive. Results of the tests conducted on this cable, according to specifications, warrants the use of this FCC for electrical interconnections in a surface nonmetallic protective covering.

Loggins, R. W.↗

STANDARDIZATION OF CEBAF 12 GEV UPGRADE CAVITY TESTING

CEBAF 12GeV upgrade project includes 80 new 7-cell cavities to form 10 cryomodules. Each cavity underwent RF qualification at 2.07K using a high power accelerating gradient test and an HOM survey in Jefferson Lab's Vertical Testing Area (VTA) before cavity string assembly. In order to ensure consistently high quality data, updated cavity testing procedures and analysis were implemented and used by a group of VTA operators. For high power tests, a cavity testing procedure was developed and used in conjunction with a LabVIEW program to collect the test data. Additionally while the cavity was at 2.07K, an HOM survey was performed using a network analyzer and a combination of Excel and Mathematica programs. Data analysis was standardized and an online logbook, Pansophy, was used for data storage and mining. The Pansophy system allowed test results to be easily summarized and searchable across all cavity tests. In this presentation, the CEBAF 12GeV upgrade cavity testing procedure, method for data analysis, and results reporting results will be discussed.

43 PARTICLE ACCELERATORS↗