Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A hybrid electrical power system for aircraft application.

Possible improvements to present aircraft electrical power systems for use in future advanced types of aircraft have been investigated. The conventional power system is examined, the characteristics of electric loads are reviewed, and various methods of power generation and distribution are appraised. It is shown that a hybrid system, with variable-frequency generation and high-voltage dc distribution, could overcome some of the limitations of the conventional system.

Lee, C. H.↗

Controlling Gas-Flow Mass Ratios

Proposed system automatically controls proportions of gases flowing in supply lines. Conceived for control of oxidizer-to-fuel ratio in new gaseous-propellant rocket engines. Gas-flow control system measures temperatures and pressures at various points. From data, calculates control voltages for electronic pressure regulators for oxygen and hydrogen. System includes commercially available components. Applicable to control of mass ratios in such gaseous industrial processes as chemical-vapor depostion of semiconductor materials and in automotive engines operating on compressed natural gas.

Morris, Brian G.↗

Solar Power System Options for the Radiation and Technology Demonstration Spacecraft

The Radiation and Technology Demonstration (RTD) Mission has the primary objective of demonstrating high-power (10 kilowatts) electric thruster technologies in Earth orbit. This paper discusses the conceptual design of the RTD spacecraft photovoltaic (PV) power system and mission performance analyses. These power system studies assessed multiple options for PV arrays, battery technologies and bus voltage levels. To quantify performance attributes of these power system options, a dedicated Fortran code was developed to predict power system performance and estimate system mass. The low-thrust mission trajectory was analyzed and important Earth orbital environments were modeled. Baseline power system design options are recommended on the basis of performance, mass and risk/complexity. Important findings from parametric studies are discussed and the resulting impacts to the spacecraft design and cost.

Kerslake, Thomas W.↗

Bifurcation Analysis of DC Electric Power Systems for Deep Space Exploration Spacecraft

Electric power system reliability is a crucial factor in the application of both manned and unmanned spacecraft that could alter the success of space exploration missions. Understanding the behavior of these electric systems is essential to determine the safe operating conditions, and subsequently, prevent undesired conditions which may cause system-wide blackouts, leaving the spacecraft in a vulnerable position. This study will use bifurcation analysis to determine the behavior of DC spacecraft electric power systems and identify the major causes of voltage instability.

Bifurcation Analysis↗

Voltage-Dependent First-Principles Simulation of Insertion of Chloride Ions into Al/Al 2 O 3 Interfaces Using the Quantum Continuum Approximation

Experiments have shown that pitting corrosion can develop in aluminum surfaces at potentials > − 0.5 V relative to the standard hydrogen electrode (SHE). Until recently, the onset of pitting corrosion in aluminum has not been rigorously explored at an atomistic scale because of the difficulty of incorporating a voltage into density functional theory (DFT) calculations. We introduce the Quantum Continuum Approximation (QCA) which self-consistently couples explicit DFT calculations of the metal-insulator and insulator-solution interfaces to continuum Poisson-Boltzmann electrostatic distributions describing the bulk of the insulating region. By decreasing the number of atoms necessary to explicitly simulate with DFT by an order of magnitude, QCA makes the first-principles prediction of the voltage of realistic electrochemical interfaces feasible. After developing this technique, we apply QCA to predict the formation energy of chloride atoms inserting into oxygen vacancies in Al(111)/α-Al 2 O 3 (0001) interfaces as a function of applied voltage. We predict that chloride insertion is only favorable in systems with a grain boundary in the Al 2 O 3 for voltages > − 0.2 V (SHE). Here our results roughly agree with the experimentally demonstrated onset of corrosion, demonstrating QCA's utility in modeling realistic electrochemical systems at reasonable computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capacitance-voltage characteristics of the electrolyte-n-InN surface and electron states at the interface

Dependences of differential capacitance of the system degenerate n-InN-electrolyte on the voltage are measured at a frequency of the probing voltage of 300 Hz. Qualitative analysis of these characteristics is performed based on a one-dimensional model of the metal-insulator-semiconductor structure in the region of bias voltages near the flat-band voltage and depletion. It is shown that the magnitude of capacitance in this voltage region is affected by electron states at the interface. The density and energy distribution of these states are evaluated. The form of the voltage dependence of capacitance in the region of accumulation also indicates the existence of the states at the interface, the energy of which exceeds the energy of the conduction band bottom by several tenths of eV. The density of these states increases as the energy increases.

36 MATERIALS SCIENCE↗

Holbrook Substation Superconductor Cable System, Long Island, New York: Final Report ~ Volume 1 [Slides]

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spacecraft high-voltage power supply construction

The design techniques, circuit components, fabrication techniques, and past experience used in successful high-voltage power supplies for spacecraft flight systems are described. A discussion of the basic physics of electrical discharges in gases is included and a design rationale for the prevention of electrical discharges is provided. Also included are typical examples of proven spacecraft high-voltage power supplies with typical specifications for design, fabrication, and testing.

Sutton, J. F.↗

Resistively Graded Insulation System for Next-Generation Converter-Fed Motors

The objective of this project was to demonstrate the feasibility of a new insulation material system capable of withstanding 10 kV/μs switching voltage ramp rate (dV/dt) with operating frequencies and temperatures targeted at converter-fed motors. If successful, with additional development, this insulation material can enable 5%-10% electric machine energy savings from advanced silicon carbide (SiC) drive implementation. To accomplish these goals, we propose to eliminate partial discharge as a degradation mechanism in high voltage, taped insulation. This can be accomplished through the use of a two-sided coating on a polymer film system that will envelop any residual defects on all sides, effectively creating a Faraday cage around the defect. This project focused on demonstrating the proof of concept for the coating. It was shown that concept of providing a stress grading coating around voids can prevent partial discharge. Simulation and lab scale experiments showed that the design can be implemented in a practical layered structure without causing overheating of the insulation due to conduction. Short term testing and calculations show there is a reasonable likelihood to improved insulation life. A path to full scale production was demonstrated, with gaps in process optimization identified as needing to be closed for full scale implementation. Longer term testing and integration onto a conductor is required to fully quantify life and show benefits at an application level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of NRZ data asymmetry on the performance of a space telemetry system

The telemetry data asymmetry due to rising and falling voltage transitions can cause undesired spectral components at the output of a spacecraft transmitter. The performance of a space telemetry system can potentially degrade because of these undesired components. Here, an expression is derived for the power spectral density of an asymmetric nonreturn-to-zero (NRZ) data stream. This formula is then used to investigate how the data bandwidth varies with data asymmetry. At the receiver end, the threshold levels of undesired spectral components that fall into the carrier-tracking-loop bandwidth are determined by examining the derived spectral density. Further, based on this formula, a simple technique is developed for the computation of bit signal-to-noise ratio (SNR) degradation due to data asymmetry. The telemetry bit SNR degradations derived using this technique are compared with results obtained previously and with measurements by the Electronic Systems Test Laboratory (ESTL) at the Lyndon B. Johnson Space Center.

Nguyen, T. M.↗

Booster Synchrotron RF System Upgrade for SPEAR3

Recent progress at the SPEAR3 includes the increase in stored current from 100 mA to 200 mA and top-off injection to allow beamlines to stay open during injection. Presently the booster injects 3.0 GeV beam to SPEAR3 three times a day. The stored beam decays to about 150 mA between the injections. The growing user demands are to increase the stored current to the design value of 500 mA, and to maintain it at a constant value within a percent or so. To achieve this goal the booster must inject once every few minutes. For improved injection efficiency, all RF systems at the linac, booster and SPEAR3 need to be phase-locked. The present booster RF system is basically a copy of the SPEAR2 RF system with 358.5 MHz and 40 kW peak RF power driving a 5-cell RF cavity for 1.0 MV gap voltage. These requirements entail a booster RF system upgrade to a scaled down version of the SPEAR3 RF system of 476.3 MHz with 1.2 MW cw klystron output power capabilities. We will analyze each subsystem option for their merits within budgetary and geometric space constraints. A substantial portion of the system will come from the decommissioned PEP-II RF stations.

43 PARTICLE ACCELERATORS↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data Driven Optimization Framework for Volt-age Regulation in Distribution Systems

This letter proposes a data-driven optimization framework for voltage regulation problems to address the challenge of model inaccuracy and parameter varying. To achieve online voltage optimization, the recursive kernel regression and interior point methods are integrated. The IEEE 123-Bus system and EPRI Ckt5 feeder are selected to validate the effectiveness of the proposed data-driven optimization framework. The proposed method is also compared with a linear function based method.

Hong, Tianqi↗