Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Theory of a stationary microwave discharge with multiply charged ions in an expanding gas jet

The formation of a jet of a nonequilibrium multiply charged ion plasma is studied in the inhomogeneous gas jet. It is shown that the geometrical divergence of the jet restricts the maximum ion charge state and results in the spatial localization of the discharge. Stationary solutions corresponding to such regimes are constructed. The model proposed can be used to optimize modern experiments on generation of hard UV radiation due to the line emission of multiply ionized atoms in a gas jet heated by high-power millimeter and submillimeter radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetoabsorption of the electromagnetic radiation by a two-dimensional electron gas with Rashba's spin-orbit coupling in a heterojunction with a lateral superlattice

Absorption of linearly polarized electromagnetic radiation by a two-dimensional electron gas in a lateral-superlattice structure subjected to a perpendicular magnetic field is calculated analytically and numerically for the first time, taking into account Rashba's spin-orbit coupling and Zeeman splitting. Calculations are carried out for semiconductor heterostructures characterized by weak and sufficiently strong spin-orbit coupling (AlGaAs/GaAs and GaAs/InGaAs, respectively). The nature of the new effect related to intense magnetoabsorption of electromagnetic radiation in the submillimeter range by a two-dimensional electron gas in a superlattice with strong spin-orbit coupling is analyzed. Magneto-optical experiments aimed at studying spin-Peierls states of charge carriers are discussed and, in this context, optimum parameters for semiconductor structures with spin-orbit coupling and values of the magnetic field are determined.

36 MATERIALS SCIENCE↗

Frequency bandwidth and conversion loss of a semiconductor heterodyne receiver with phonon cooling of two-dimensional electrons

The temperature and concentration dependences of the frequency bandwidth of terahertz heterodyne AlGaAs/GaAs detectors based on hot electron phenomena with phonon cooling of two-dimensional electrons have been measured by submillimeter spectroscopy with a high time resolution. At a temperature of 4.2 K, the frequency bandwidth at a level of 3 dB (f{sub 3dB}) is varied from 150 to 250 MHz with a change in the concentration n{sub s} according to the power law f{sub 3dB} {proportional_to} n{sub s}{sup -0.5} due to the dominant contribution of piezoelectric phonon scattering. The minimum conversion loss of the semiconductor heterodyne detector is obtained in structures with a high carrier mobility ({mu} > 3 x 10{sup 5} cm{sup 2} V{sup -1} s{sup -1} at 4.2 K).

36 MATERIALS SCIENCE↗

Interaction of carbon dioxide laser radiation with a nanotube array in the presence of a constant electric field

The dependence of the current density on the leading edge width of the alternating (high-frequency) field amplitude is studied at various constant (or unsteady) fields. The dependence of amplified microwaves in the two-millimeter range on a longitudinal coordinate is determined. The problem of submillimeter radiation generation in a system of parallel carbon nanotubes exposed to two-frequency carbon dioxide (CO{sub 2} laser) laser radiation in the presence of a constant (or unsteady) field is studied. The possibility of using freely oriented carbon nanotubes parallel to each other is shown.

36 MATERIALS SCIENCE↗

Heterobarrier Varactors with Nonuniformly Doped Modulation Layers

Optimum shape of the capacitance–voltage (C–V) characteristic is a critical parameter determining the efficiency of frequency multiplication in heterobarrier varactors (HBVs) operating in the millimeter and submillimeter frequency ranges. A numerical model for calculating the C–V characteristics and leakage currents of HBV heterostructures with arbitrary composition and doping profiles has been verified on the basis of published and original experimental data. A specially designed HBV heterostructure with three undoped InAlAs/AlAs/InAlAs barriers surrounded by nonuniformly doped n-InGaAs modulation layers has been grown by molecular beam epitaxy on InP substrate. Prototype HBVs manufactured using the proposed heterostructure demonstrated a nearly cosine shape of the C–V curve at bias voltages up to 2 V, increased overlap capacitance, and low leakage currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simons Observatory: characterizing the Large Aperture Telescope Receiver with radio holography

Here, we present near-field radio holography measurements of the Simons Observatory Large Aperture Telescope Receiver optics. These measurements demonstrate that radio holography of complex millimeter-wave optical systems comprising cryogenic lenses, filters, and feed horns can provide detailed characterization of wave propagation before deployment. We used the measured amplitude and phase, at 4 K, of the receiver near-field beam pattern to predict two key performance parameters: 1) the amount of scattered light that will spill past the telescope to 300 K and 2) the beam pattern expected from the receiver when fielded on the telescope. These cryogenic measurements informed the removal of a filter, which led to improved optical efficiency and reduced sidelobes at the exit of the receiver. Holography measurements of this system suggest that the spilled power past the telescope mirrors will be less than 1%, and the main beam with its near sidelobes are consistent with the nominal telescope design. This is the first time such parameters have been confirmed in the lab prior to deployment of a new receiver. This approach is broadly applicable to millimeter and submillimeter instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibration measurement of a miniature component by high-speed image-plane digital holographic microscopy

Measuring deformation of vibrating specimens whose dimensions are in the submillimeter range introduces a number of difficulties using laser interferometry. Normal interferometry is not suitable because of a phase ambiguity problem. In addition, the noise effect is much more serious in the measurement of small objects because a high-magnification lens is used. We present a method for full-field measurement of displacement, velocity, and acceleration of a vibrating miniature object based on image-plane digital holographic microscopy. A miniature cantilever beam is excited by a piezoelectric transducer stage with a sinusoidal configuration. A sequence of digital holograms is captured using a high-speed digital holographic microscope. Windowed Fourier analysis is applied in the spatial and spatiotemporal domains to extract the displacement, velocity and acceleration. The result shows that a combination of image-plane digital holographic microscopy and windowed Fourier analyses can be used to study vibration without encountering a phase ambiguity problem, and one can obtain instantaneous kinematic parameters on each point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon noise correlations in millimeter-wave telescopes

Many modern millimeter and submillimeter (“mm-wave”) telescopes for astronomy are deploying more detectors by increasing the detector pixel density and, with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch p pix is small compared to the product of the wavelength λ and the focal ratio F , or p pix ≲1.2 F λ , the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown and Twiss (HBT) effect. When this HBT effect is non-negligible, the array-averaged sensitivity scales with the detector count N det less favorably than the uncorrelated limit of N det −1/2 . In this paper, we present a general prescription to calculate this HBT correlation based on a quantum optics formalism and extend it to polarization-sensitive detectors. We then estimate the impact of HBT correlations on the sensitivity of a model mm-wave telescope and discuss the implications for a focal plane design.

Hill, Charles A. (ORCID:0000000226416878)↗

Enhancement of terahertz fields in LiTaO 3 waveguides using a conical pulse front

The development of methods for the generation of strong ultrafast electromagnetic pulses in the terahertz (THz) spectral range has led to a surge of progress in nonlinear THz spectroscopy and THz control of molecular and collective responses. For spectroscopy in the 1-THz range, the submillimeter wavelengths and associated large spot sizes, large optical elements, and short distances between final focusing elements and samples can lead to cumbersome experimental setups that are incompatible with some sample environments. Here, we introduce a novel terahertz ring excitation (TREx) optical pumping geometry to generate superposing, focusing fields in planar THz waveguides made out of the electro-optic material lithium tantalate. High THz fields, >175 kV/cm, are generated and measured optically with no free-space THz propagation. The field level achieved by pumping with a sequence of concentric rings of excitation light exceeds by about 20× the result of a single cylindrically focused line of pump light that has been used routinely in previous work. The technique opens new prospects for compact waveguide-based linear and nonlinear THz spectroscopy and signal processing.

47 OTHER INSTRUMENTATION↗

Angular-dispersion-induced spatiotemporal aberrations in noncollinear optical parametric amplifiers

We characterize spatiotemporal aberrations induced in noncollinear optical parametric amplifiers (NOPAs), for the first time (to our knowledge), using spatially resolved spectral interferometry. Measurements show that when the submillimeter pump and signal beams are not correctly aligned, several degrees of pulse-front tilt caused by angular dispersion are introduced by the NOPA angular-dependent gain, without significant loss of bandwidth. After eliminating the pulse-front tilt, analysis of the residual higher-order aberrations shows that far-field intensities reaching 80% of the theoretical limit can be achieved without complex spatiospectral phase optimization.

Bromage, Jake↗

High-resolution mapping of phase-matching conditions in second-order nonlinear crystals

We demonstrate the spatial mapping of phase-matching conditions in nonlinear crystals using detuned second-harmonic generation. A beam-stabilization system cancels out the angular wobbling of the translation stages that scan the crystal under test in front of the static probe beam at the fundamental frequency. A submillimeter resolution over the full scanned aperture, 50 × 50 mm 2 , is demonstrated. The mapping of several partially deuterated potassium dihydrogen phosphate (DKDP) crystals reveals the spatially nonuniform phase-matching conditions due to internal variations in crystal properties and high-frequency surface variations.

36 MATERIALS SCIENCE↗

Ultrasonic welding of AZ31B magnesium alloy

This article overviews the ultrasonic welding process, a solid-state joining method, using the example of welding of a magnesium alloy as well as the joining of magnesium alloys in general. In situ high-speed imaging and infrared thermography were utilized to study interfacial relative motion and heat generation during ultrasonic spot welding of AZ31B magnesium (Mg) alloys. A postweld ultrasonic nondestructive evaluation was performed to study the evolution of local bond formation at the faying interface (contact surface of the joint between the top and bottom Mg sheets) at different stages of the welding process. Two distinct stages were observed as the welding process progresses. In the early stage, localized reciprocating sliding occurred at the contact faying interface between the two Mg sheets, resulting in localized rapid temperature rise from the localized frictional heating. Microscale (submillimeter) bonded regions at the Mg–Mg faying surface started to form, but the overall joint strength was low. Here, the early-stage localized bonds were broken during the subsequent vibrations. In the later stage, no relative motion occurred at any points of the faying interface. Localized bonded regions coalesced into a macroscale joint that was strong enough to prevent the Mg–Mg interface from further breakage and sliding. With increasing welding time, the bonded area continued to increase.

36 MATERIALS SCIENCE↗

Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D printed Ni-Mn-Fe Bi-Functional Catalyst for Metal Air Batteries

Oxygen evolution catalyst with porous structures on the submillimeter and millimeter ranges have been shown to have high catalytic activity. Often, a limiting factor in the performance of a catalyst can be its specific surface area as this can limit the availability of active sites which encourage the desired reaction. As such, the inclusion of a hierarchical structure that include both meso-scale and nano-scale porosity can offer a means to greatly increase the performance of electrochemical catalysts. We have developed a method for manufacturing samples with such a hierarchical structure by combining techniques of direct ink writing (DIW), thermal sintering and free corrosion based dealloying. This allows us to prepare three-dimensionally structured samples with open-cell porosity at the macro-, micro- and nano-scales. Each level of porosity offers a different advantage to the overall functionality and applicability of this technology.

25 ENERGY STORAGE↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

More α Than β for Prostate Cancer?

Radionuclide therapy for prostate cancer started more than 70 y ago (1). Nuclear medicine has since evolved considerably to provide a multitude of new imaging and therapy options. The past decade witnessed an unprecedented expansion of radioligands for prostate cancer. Milestones include the first α-emitter for treatment of symptomatic bone metastases (2) and theranostic vectors directed at the prostate-specific membrane antigen (PSMA) or bombesin receptor (3–5). However, current radionuclide therapies are applied at a late stage of the disease aiming at palliation. Despite recent advances for treatment of metastatic prostate cancer, cure remains an unmet need of the 21st century. Cancer spreads early and develops slowly as submillimeter occult lesions. Lesions grow at distant sites and become detectable only when significant morphologic or metabolic alterations have formed, often years to decades after the initial spread (6). Effective ablation of small metastases is critical for cure and presents a specific challenge for β-emitting radionuclide therapy. Millimeter-range β-particles deliver insufficient amounts of radiation to millimeter-size tumor lesions, as energy deposition extends and dilutes beyond lesion boundaries (Fig. 1). α-radiation, because of its micrometer range, targets millimeter-size tumor volumes at higher relative yield (Fig. 1). Further evidence points to a superior biologic effectiveness for α-therapy based on high-linear-energy transfer resulting in frequent double-strand DNA breaks (7). However, are basic advantages of α-therapy associated with a clinical benefit?

62 RADIOLOGY AND NUCLEAR MEDICINE↗