Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗

Certification and Rating of Attachments for Fenestration Technologies

In the U.S., windows still represent a significant energy savings opportunity in residential and commercial buildings, and for decades the United States Department of Energy (DOE) has funded fenestration software tools, analysis, studies, and the National Fenestration Rating Council (NFRC). Despite significant developments in window technology and recognition of efficient products, studies conducted by the U.S. Energy Information Administration and Pacific Northwest National Laboratory (PNNL) found that approximately 64% of U.S. homes currently have inefficient windows. Window attachments (interior and exterior blinds, shades, storm windows, awnings, shutters, etc.) can offer a more cost-effective option to improve the energy performance of residential and commercial windows. In previous years, the window attachment industry attempted to work with the NFRC to generate a window attachment rating program, but was unable to access funding or technical resources necessary to address window attachments, which added many levels of complexity on top of NFRC’s scope of windows and glazing. Starting in 2014, the DOE Office of Energy Efficiency and Renewable Energy (EERE) funded the Window Coverings Manufacturing Association (WCMA) to develop the Attachments Energy Rating Council (AERC) along with policies and procedures to deliver an unbiased, credible, comparable, relevant, and cost-effective window attachment energy rating program for the residential and commercial sectors over a four-year period. This project was created because there were no consistent and credible performance rating mechanisms for assessing the energy performance of window attachments. Without a standardized approach, consumers found it difficult to make informed and comparative decisions about the energy performance of window attachments, and utilities faced challenges offering incentives for energy-efficient attachments. The goal of this project was two-fold: to develop procedures to rate and certify the energy performance of window attachments and to create an educational, consumer-facing Certified Products Website (CPW) to help consumers and other stakeholders make more informed window attachments purchasing decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A highly parallel multigrid-like method for the solution of the Euler equations

We consider a highly parallel multigrid-like method for the solution of the two dimensional steady Euler equations. The new method, introduced as filtering multigrid, is similar to a standard multigrid scheme in that convergence on the finest grid is accelerated by iterations on coarser grids. In the filtering method, however, additional fine grid subproblems are processed concurrently with coarse grid computations to further accelerate convergence. These additional problems are obtained by splitting the residual into a smooth and an oscillatory component. The smooth component is then used to form a coarse grid problem (similar to standard multigrid) while the oscillatory component is used for a fine grid subproblem. The primary advantage in the filtering approach is that fewer iterations are required and that most of the additional work per iteration can be performed in parallel with the standard coarse grid computations. We generalize the filtering algorithm to a version suitable for nonlinear problems. We emphasize that this generalization is conceptually straight-forward and relatively easy to implement. In particular, no explicit linearization (e.g., formation of Jacobians) needs to be performed (similar to the FAS multigrid approach). We illustrate the nonlinear version by applying it to the Euler equations, and presenting numerical results. Finally, a performance evaluation is made based on execution time models and convergence information obtained from numerical experiments.

Tuminaro, Ray S.↗

Technical solutions to reduce mediastinal irradiation in young patients undergoing treatment for lymphomas: Preliminary experience

This study aims at optimizing treatment planning in young patients affected by lymphoma (Stage II to III) by using an inclined board (IB) that allows reducing doses to the organs at risk. We evaluated 19 young patients affected by stage I to III lymphomas, referred to our Department for consolidation radiotherapy (RT) treatment on the mediastinum. Patients underwent 2 planning computed tomography (CT) scans performed in different positions: flat standard position and inclined position. A direct comparison between the different treatment plans was carried out analyzing dosimetric parameters obtained from dose-volume histograms generated for each plan. Comparison was performed to evaluate the sparing obtained on breast and heart. Dosimetric evaluation was performed for the following organs at risk (OARs): mammary glands, lungs, and heart. A statistically significant advantage was reported for V{sub 5}, V{sub 20}, and V{sub 30} for the breast when using the inclined board. A similar result was obtained for V{sub 5} and V{sub 10} on the heart. No advantage was observed in lung doses. The use of a simple device, such as an inclined board, allows the optimization of treatment plan, especially in young female patients, by ensuring a significant reduction of the dose delivered to breast and heart.

61 RADIATION PROTECTION AND DOSIMETRY↗

Post-Irradiation Evaluation of Eurofer97 Fracture Toughness Using Miniature Multinotch Bend Bar Specimens

In this study, we performed fracture toughness characterization of ten neutron-irradiated Eurofer97 variants using precracked miniature multi-notch bend bar (M4CVN) specimens based on the Master Curve method in the ASTM E1921 standard. The neutron irradiation was performed in the flux trap position of the High Flux Isotope Reactor (HFIR) of the Oak Ridge National Laboratory (ORNL) with the nominal irradiation temperature of 300°C and irradiation dose of 2.5 displacements per atom (dpa). Depending on the irradiation temperature and materials, we observed different degrees of irradiation hardening and embrittlement for ten Eurofer97 variants. The upper shift in the Master Curve reference temperature T0Q vs. the increase in Vickers microhardness values showed a liner relationship for only a few materials indicating different irradiation responses of the Eurofer97 variants.

Chen, Xiang↗

Laser Frequency Stabilization and Control through Offset Sideband Locking to Optical Cavities

We describe a class of techniques whereby a laser frequency can be stabilized to a fixed optical cavity resonance with an adjustable offset, providing a wide tuning range for the central frequency. These techniques require only minor modifications to the standard Pound-Drever-Hall locking techniques and have the advantage of not altering the intrinsic stability of the frequency reference. In a laboratory investigation the sideband techniques were found to perform equally well as the standard, non-tunable Pound-Drever-Hall technique, each providing more than four decades of frequency noise suppression over the free-running noise. An application of a tunable system as a pre-stabilization stage in a phase-lock loop is also presented with the combined system achieving a frequency noise suppression of nearly twelve orders of magnitude.

Thorpe, James I.↗

Development of a NASA standard gas generator

The goals of the NASA Standard Gas Generator (NSGG) Program are to create a NASA standard gas generating cartridge, characterize its performance, and make it readily available to users. A cartridge within the same envelope as the NASA Standard Initiator (NSI) has the greatest potential use. This potential use is described in viewgraph form. Our approach for NSGG development and qualification was planned to be conducted in several phases. Test methods were developed to evaluate output performance for a variety of potential applications. A feasibility study using modified NSI's was accomplished. Preliminary and final development will be conducted with a delta qualification to evaluate the effects of manufacturing lots and environments. Feasibility study results, feasibility study conclusions, and future plans are presented.

Bement, Laurence J.↗

Industrial Wireless Sensor Standards; A User Perspective

Future industrial use of wireless instrumentation will undoubtedly increase dramatically in the coming years. Deployment of such instrumentation in an industrial setting with its security and robustness criteria that are much more stringent than residential performance criteria hinges on user acceptance of verified performance as well as meeting cost requirements. Today, circa 2011, these industrial users are faced with many choices when specifying a wireless sensor network, including radio performance, battery life, interoperability concerns, and standards compliance. With industrial users standing on the precipice to order and deploy (literally) millions of wireless instruments, it is imperative that accurate information for applying the technology to real-world applications be available to the end-user.

47 OTHER INSTRUMENTATION↗

Experimental evaluation of a semi-open membrane-based absorption heat pump system utilizing ionic liquids

While the use of energy efficient absorption heat pumps has been typically limited to the high capacity commercial and industrial applications, the use of a semi-open absorption heat pump for water heating has been demonstrated to be an energy efficient alternative for residential scale applications. A semi-open absorption system uses ambient water vapor as the refrigerant in the absorber where its heat of phase change is transferred to the process water, cooling the solution in the absorber. The solution is pumped to the desorber, where by adding heat, the water vapor is released from the solution and condensed in the condenser. The heat of phase change of water vapor is transferred to process water again in the condenser. This cycle when implemented with a membrane-based absorber in a plate and frame form of heat exchanger using ionic liquids can overcome the challenges related to the system architecture of conventional absorption heat pumps like the lower efficiency at small scale, crystallization/corrosion issues with the desiccants and the high cost of hermetically sealed components. The cycle COP for such a system was previously demonstrated by Chugh et al. for high humidity conditions. In this experimental study, design improvements were made that expand the system’s applicability to more practical and standardized test conditions. With these improvements, the performance of the system was evaluated. The results presented in this study demonstrate the improved system’s viability as a heat pump water heater conforming to standard water heater test conditions. Performance was measured at a cycle thermal COP of 1.2 with a hot water delivery water temperature of 56 °C and ambient air at 19 °C and 49% RH.

42 ENGINEERING↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Methodology Description for the Policy Analysis Modeling System (PAMS)

The Policy Analysis Modeling System is a spreadsheet tool developed to provide an estimate of costs and benefits of appliance efficiency standard and labeling programs. PAMS is a self-contained spreadsheet model that provides both a consumer-oriented analysis and a national cost-benefit analysis in the style of the analysis performed for U.S. appliance efficiency standards. The tool allows policy analysts from many countries to produce a first-cut analysis of appliance efficiency program costs and benefits, examine the sensitivities of the analysis with respect to different policy parameters and assumptions, and continually refine the analysis as more data becomes available. The methodology is a bottom-up approach, using technical specifications for particular products in estimating the increased cost to the consumer resulting from implementation of particular energy-saving designs. It is designed to operate for the widest possible variety of countries, and with as little need as possible for detailed input data. For more accurate results, it can be easily customized to use the most reliable country-specific data inputs. In addition to consumer financial impacts, the tool provides national primary energy savings and estimates of carbon emissions mitigation resulting from the program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CCD charge collection efficiency and the photon transfer technique

The charge-coupled device (CCD) has shown unprecendented performance as a photon detector in the areas of spectral response, charge transfer, and readout noise. Recent experience indicates, however, that the full potential for the CCD's charge collection efficiency (CCE) lies well beyond that which is realized in currently available devices. A definition of CCE performance is presented and a standard test tool (the photon transfer technique) for measuring and optimizing this important CCD parameter is introduced. CCE characteristics for different types of CCDs are compared; the primary limitations in achieving high CCE performance are discussed, and the prospects for future improvement are outlined.

Janesick, J.↗

A Standard Reference Model for Data Archives

An implementable Data Archive Architecture is being developed for trusted digital repositories based on the Reference Model for an Open Archival Information System (OAIS) – ISO 14721. A set of interoperable protocols and interface specifications are planned that will offer capabilities for accessing, merging, and re-using data, both within and across the operational boundaries of trustworthy digital repositories. The model will also provide support for the fundamental scientific need to verify the reproducibility of results. This standards development task is being performed by the Data Archive Interoperability (DAI) working group within the Consultative Committee for Space Data Systems (CCSDS). The architecture integrates concepts from the OAIS Reference Model, the ISO/IEC 11179 Metadata Registry (MDR) standard, the CCSDS Reference Architecture for Space Information Management (RASIM), the proposed draft recommended practice document, Information Preparation to Enable Long Term Use (IPELTU), and three decades of digital repository development for science research.

Ambacher, Bruce↗

Primer Stepper Motor Nomenclature, Definition, Performance and Recommended Test Methods

There has been an unfortunate lack of standardization of the terms and components of stepper motor performance, requirements definition, application of torque margin and implementation of test methods. This paper will address these inconsistencies and discuss in detail the implications of performance parameters, affects of load inertia, control electronics, operational resonances and recommended test methods. Additionally, this paper will recommend parameters for defining and specifying stepper motor actuators. A useful description of terms as well as consolidated equations and recommended requirements is included.

Starin, Scott↗

Risk-Based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS↗

Risk-based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS↗