Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Polarimetric Analysis of the Long Duration Gamma-Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager

A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2–5.0 MeV. We measured the polarization of GRB 160530A using (1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve and (2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the 99% confidence minimum detectable polarization levels of 72.3% ± 0.8% (SM) and 57.5% ± 0.8% (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining 90% confidence upper limit on the polarization level was 46% (MLM).

79 ASTRONOMY AND ASTROPHYSICS↗

Maximum Likelihood Compton Polarimetry with the Compton Spectrometer and Imager

Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an ideal Compton polarimeter can be improved by ∼21% when an unbinned, maximum likelihood method (MLM) is used instead of the standard approach of fitting a sinusoid to a histogram of azimuthal scattering angles. Here we outline a procedure for implementing this maximum likelihood approach for real, nonideal polarimeters. As an example, we use the recent observation of GRB 160530A with the Compton Spectrometer and Imager. We find that the MDP for this observation is reduced by 20% when the MLM is used instead of the standard method.

79 ASTRONOMY AND ASTROPHYSICS↗

THE VARIABILITY OF HCN IN TITAN’S UPPER ATMOSPHERE AS IMPLIED BY THE CASSINI ION-NEUTRAL MASS SPECTROMETER MEASUREMENTS

HCN is an important constituent in Titan’s upper atmosphere, serving as the main coolant in the local energy budget. In this study, we derive the HCN abundance at the altitude range of 960–1400 km, combining the Ion-Neutral Mass Spectrometer data acquired during a large number of Cassini flybys with Titan. Typically, the HCN abundance declines modestly with increasing altitude and flattens to a near constant level above 1200 km. The data reveal a tendency for dayside depletion of HCN, which is clearly visible below 1000 km but weakens with increasing altitude. Despite the absence of convincing anti-correlation between HCN volume mixing ratio and neutral temperature, we argue that the variability in HCN abundance makes an important contribution to the large temperature variability observed in Titan’s upper atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Soot Particle Aerosol Mass Spectrometer (SP-AMS) BBOP

We collected rapid (1 second time response) measurements of aerosol chemical composition (ug/m3) of biomass burning plumes (including wild fires and controlled agricultural burns) sampled on the DOE G1 aircraft during the 2013 Biomass Burning Observation Project (BBOP) using the Soot Particle Aerosol Mass Spectrometer (SP-AMS) developed and deployed by Aerodyne Research, Inc.

54 ENVIRONMENTAL SCIENCES↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

Particle composition measurements for ultrafine particles collected at the EPCAPE Mount Soledad site from 04-27-2023 to 06-13-2023 using a Thermal Desorption Chemical Ionization Mass Spectrometer

The dataset contains particle composition data for both the positive and negative reagent ion modes of the Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS). The dataset is split into two directories: one for particles with diameters of 30 nm and the other for particles with diameters of less than 100 nm. The positive reagent ion mode uses H3O+ as the reagent ion, and ionization usually occurs through hydrogen addition. The negative mode uses O2- as the reagent ion. Negative mode ionization generally occurs through hydrogen abstraction, but O2- addition is also possible. Ion concentrations were normalized to total ion counts, and unknown ions were then removed from the data. The name of each ion fraction time series includes the mass to charge ratio and the chemical formula for the ion. Time is recorded in seconds since 1/1/1904. The time zone is UTC.

54 ENVIRONMENTAL SCIENCES↗

SCILLA Scanning Electrical Mobility Spectrometer (SEMS) airborne data

The Scanning Electrical Mobility Spectrometer (SEMS) provides measurements of bulk aerosol size distributions, which are crucial for studying aerosol-cloud interactions. The instrument sampled through two different inlets: an isokinetic inlet and a counter-flow virtual impactor (CVI) inlet. Data were collected to help improve climate and earth systems models, characterize atmospheric conditions, and validate satellite observations and climate simulations.

Scanning Electrical Mobility Spectrometer↗

Rocket-UV Spectrometer

This is a report of the second three months (March-May 1961) of a program to design and fabricate an ultraviolet spectrometer and fine guidance control for use in an Aerobee-Hi rocket. The work is being done under Subcontract No. 1 under Contract NASr-3 between Princeton University and the National Aeronautical and Space Administration. The design goals for this instrument are described in the report for the first three month period (Perkin-Elmer Engineering Report No. 5906). The accomplishments of the second three month period include the solution of certain design problems, the establishment of an effective liaison system with personnel at Goddard Space Flight Center, and the completion of certain design and fabrication tasks.

ULTRAVIOLET SPECTROMETER↗