Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Extraterrestrial materials processing and construction

Three different chemical processing schemes were identified for separating lunar soils into the major oxides and elements. Feedstock production for space industry; an HF acid leach process; electrorefining processes for lunar free metal and metal derived from chemical processing of lunar soils; production and use of silanes and spectrally selective materials; glass, ceramics, and electrochemistry workshops; and an econometric model of bootstrapping space industry are discussed.

Criswell, D. R.↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Large-scale computations in fluid mechanics; Proceedings of the Fifteenth Summer Seminar on Applied Mathematics, University of California, La Jolla, CA, June 27-July 8, 1983. Parts 1 & 2

Papers are presented on such topics as the use of semi-Lagrangian advective schemes in meteorological modeling; computation with high-resolution upwind schemes for hyperbolic equations; dynamics of flame propagation in a turbulent field; a modified finite element method for solving the incompressible Navier-Stokes equations; computational fusion magnetohydrodynamics; and a nonoscillatory shock capturing scheme using flux-limited dissipation. Consideration is also given to the use of spectral techniques in numerical weather prediction; numerical methods for the incorporation of mountains in atmospheric models; techniques for the numerical simulation of large-scale eddies in geophysical fluid dynamics; high-resolution TVD schemes using flux limiters; upwind-difference methods for aerodynamic problems governed by the Euler equations; and an MHD model of the earth's magnetosphere.

Engquist, B. E.↗

Geometrical Detector Considerations in Laser Sensing Applications

We have studied the influence of the geometrical interaction of different detectors with the impinging optical/laser received beam for a wide range of laser sensing applications. Although different techniques apply, it is found that similar aspects of geometrical physics plays a role in direct detection of a range-resolved large M(sup 2) OPO atmospheric Lidar, heterodyne multi-detector reception of atmospheric turbulence distorted coherent lidar type laser sensing, and the distribution and summation of laser induced fluorescence signals after being spectrally resolved with a spectrometer and detected by a column summing CCD detector. In each of these systems, the focused received light is spatially and spectrally distributed due to several factors including Field-of-View considerations, laser beam quality/divergence, multi-detector aspects, and hardware and software summation (coherent and non-coherent) of multi-element or spatially integrated signals. This invited talk will present some of our recent results in these areas and show the similarities in the detector spatial and temporal summation techniques of these different laser sensing systems.

Killinger, Dennis↗

Chemical Compositions and Abundance Anomalies in Stellar Coronae ADP 99

Progress has been made using both EUVE (Extreme Ultraviolet Explorer) and ASCA (Advanced Satellite for Cosmology and Astrophysics) data and a new postdoctoral scientist has now been hired. Stars studied to date include YY Gem (dMe binary), xi Boo A (intermediate activity G8 V), xi UMa (more active G quadruple system) HR1099 (K1 IV + G5 V) RS CVn-like, AU Mic (dMe). In addition to a paper that concentrated on abundancies in HR1099, a paper was recently submitted on the coronal abundances of AR(tilde)Lac that revealed an interesting pattern of overabundances of very low FIP elements (Al and Ca) compared to the low FIP elements Si, Mg and Fe. Two papers are nearing completion on methods of analysis and on the abundances in the corona of AU(tilde)Mic. Additionally, two invited conference proceedings papers are being published on this work. The main conclusion of the study to date is that our existing ideas of coronal abundance anomalies need complete revision. The solar-like FIP effect is replaced by a pattern than appears to enhance high FIP elements rather than low FIP elements in very active stars. The archival studies we are undertaking now are revealing some key details of these patterns, and are beginning to map out the anomalies as a function of spectral type, a key goal of this study.

Drake, Jeremy↗

Simulations of OSIRIS-REx Atmospheric Entry for Comparisons with Data from the Imaging Campaign

Results from pre-flight flow and radiation simulations for the OSIRIS-REx Sample Return Capsule along a candidate entry trajectory are presented. These results are from pre-flight simulations in support of the observation campaign. Details of the methodology for computing temporal variation of spectral irradiance on an instrument onboard an aerial observation platform are presented along with a sampling of results. An attempt is made to use the methodology presented to assess the level of elemental sodium in the shock layer. The final paper will be based on the actual flight trajectory and will include comparisons of predictions with calibrated spectrometric data.

Spectrometric Imaging↗

Demonstration of GaN HEMT MMIC High-Power Amplifier for Lunar Proximity Communications

In this paper, we demonstrate a high efficiency, Ka-band (23.15 to 23.55 GHz) GaN HEMT MMIC based single-ended high power amplifier (HPA). The measured Pout, Gain, PAE, RMS EVM for Offset-QPSK, 8PSK, 16APSK, and 32APSK waveforms, 3rd-order IMD products, noise figure, and phase noise are presented. The results indicate that the saturated output power (P sat ) and the small signal Gain are on the order of 38.8 dBm (7.6 W) and 29.3 dB, respectively. The PAE at Psat is 20.0%. At the 1-dB compression point, the RMS EVM and the out-of-band spectral regrowth are less than 6% and –26 dBc respectively, for all four waveforms. Additionally, the spectrum is in compliance with the NTIA mask requirements for all four waveforms. The output 3rd-order intercept point (OIP3) is on the order of 42 dBm. The noise figure is less than 9.5 dB. The SSB phase noise spectral density is compliant with the envelope defined by the MIL-STD-188-164C. The HPA can enable proximity forward links between the orbiting Gateway/relay satellites and the lunar surface elements and cross links between relay satellites.

Ka-band↗

An in Situ Technique for Elemental Analysis of Lunar Surfaces

An in situ analytical technique that can remotely determine the elemental constituents of solids has been demonstrated. Laser-Induced Breakdown Spectroscopy (LIBS) is a form of atomic emission spectroscopy in which a powerful laser pulse is focused on a solid to generate a laser spark, or microplasma. Material in the plasma is vaporized, and the resulting atoms are excited to emit light. The light is spectrally resolved to identify the emitting species. LIBS is a simple technique that can be automated for inclusion aboard a remotely operated vehicle. Since only optical access to a sample is required, areas inaccessible to a rover can be analyzed remotely. A single laser spark both vaporizes and excites the sample so that near real-time analysis (a few minutes) is possible. This technique provides simultaneous multielement detection and has good sensitivity for many elements. LIBS also eliminates the need for sample retrieval and preparation preventing possible sample contamination. These qualities make the LIBS technique uniquely suited for use in the lunar environment.

Kane, K. Y.↗

Synthesis and study of Fe{sup 2+} : MgAl{sub 2}O{sub 4} ceramics for active elements of solid-state lasers

The results of pioneering studies on preparation of highly transparent Fe{sup 2+} : MgAl{sub 2}O{sub 4} ceramics from powders synthesised in a laser torch are presented. This ceramics with a high transparency in the near-IR spectral region is synthesised for the first time at a low temperature (1300°C) and a short (1 h) sintering time. It is found that, as the iron oxide concentration increases from 0.1 to 5 wt %, the concentration of Fe{sup 3+} ions in samples decreases to zero. It is shown that the samples of Fe{sup 2+} : MgAl{sub 2}O{sub 4} ceramics contain the second phase (MgO){sub 0.91}(FeO){sub 0.09} with a concentration of several percent, which considerably decreases transmission coefficient T in the visible region. At the same time, the T coefficient increases with increasing wavelength λ due to a decrease in Rayleigh scattering and almost reaches the theoretical value 85.6 % for λ = 4 μm. The absorption cross section σ for Fe{sup 2+} ions at λ = 2 μm is determined to be (1.66 ± 0.14) × 10{sup −20} cm{sup 2}. (paper)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence for elemental variation in the ejecta of the Tycho supernova remnant

We present an X-ray study of the Tycho supernova remnant utilizing archival data from the high-resolution imagers (HRIs) on Einstein and ROSAT, the low-energy imaging telescopes (LEITs) on EXOSAT, and spectral data from the Broad Band X-ray Telescope (BBXRT). We have made use of the differing HRI bandpasses to construct images of Tycho in two spectral bands, o.7-1.8 keV and 1.8-4.5 keV. We find that the two images differ, with the harder image showing enhanced emission along much of the south, west, and north periphery. There appears to be enhanced soft emission in the interior and in one particular knot of emission in the southeast. Besides continuum (which we model here as thermal bremsstrahlung emission), we believe the hard image shows primarily the distribution of high-ionization Si and S K-shell lines which lie in the 1.8-2.6 keV band, while the softer image has contributions from Si as well as Fe XVII to Fe XXIV L-shell lines in the 0.7-1.4 keV band. Guided by the results of nonequilibrium ionization modeling of the BBXRT spectral data, we interpret the observed contrast in hard and soft X-ray emission in terms of variations in abundance, ionization timescale, and temperature. The most likely explanation for the spectral differences are spatial variations of the relative abundances of Si, S, and Fe.

Vancura, O.↗

Using neural networks to assist in OPAD data analysis

The space shuttle main engine (SSME) became the subject of plume emission spectroscopy in 1986 when researchers from NASA-Marshall Space Flight Center (MSFC), Arnold Engineering Development Center (AEDC), and Rocketdyne went to the SSME test stands at the NASA-Stennis Space Center and at Rocketdyne's Santa Susan Field Laboratory to optically observe the plume. Since then, plume spectral acquisitions have recorded many nominal tests and the qualitative spectral features of the SSME plume are now well established. Significant discoveries made with both wide-band and narrow-band plume emission spectroscopy systems led MSFC to promote the Optical Plume Anomaly Detection (OPAD) program with a goal of instrumenting all SSME test stands with customized spectrometer systems. A prototype OPAD system is now installed on the SSME Technology Test Bed (TTB) at MSFC. The OPAD system instrumentation consists of a broad-band, optical multiple-channel analyzer (OMA) and a narrow-band device called a polychrometer. The OMA is a high-resolution (1.5-2.0 Angstroms) 'super-spectrometer' covering the near-ultraviolet to near-infrared waveband (2800-7400 Angstroms), providing two scans per second. The polychrometer consists of sixteen narrow-band radiometers: fourteen monitoring discrete wavelengths of health and condition monitoring elements and two dedicated to monitoring background emissions. All sixteen channels are capable of providing 500 samples per second. To date, the prototype OPAD system has been used during 43 SSME firings on the TTB, collecting well over 250 megabytes of plume spectral data. One goal of OPAD data analysis is to determine interatively with the help of a computer code, SPECTRA4, developed at AEDC. Experience has shown that iteration with SPECTRA4 is an incredibly labor intensive task and not one to be performed by band. What is really needed is the 'inverse' of SPECTRA4 but the mathematical model for this inverse mapping is tenuous at best. However, the robustness of PSECTRA4 run in the 'forward' direction means that accurate input/output mappings can be obtained. If the mappings were inverted (i.e., input becomes output and output becomes input) then an 'inverse' of SPECTRA4 would be at hand but the 'model' would be specific to the data utilized and would in no way be general. Building a generalized model based upon known input/output mappings while ignoring the details of the governing physical model is possible through the use of a neural network. The research investigation described involves the development of a neural network to provide a generalized 'inverse' of SPECTRA4. The objectives of the research were to design an appropriate neural network architecture, train the network, and then evaluate its performance.

Whitaker, Kevin W.↗

Improvements in RIMS Isotopic Precision: Application to in situ atom-limited analyses

Resonance ionization mass spectrometry offers high sensitivity and elemental selectivity in microanalysis, but the isotopic precision attainable by this technique has been limited. Here we report instrumental modifications to improve the precision of RIMS isotope ratio measurements. Special attention must be paid to eliminating pulse-to-pulse variations in the time-of-flight mass spectrometer through which the photoions travel, and resonant excitation schemes must be chosen such that the resonance transitions can substantially power-broadened to cover the isotope shifts. We report resonance ionization measurements of chromium isotope ratios with statistics-limited precision better than 1%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating ultrafast electron dynamics at surfaces using extreme ultraviolet (XUV) reflection–absorption spectroscopy

Here we review the recent development of extreme ultraviolet reflection–absorption (XUV-RA) spectroscopy. This method combines the benefits of X-ray absorption spectroscopy, such as element, oxidation, and spin state specificity, with surface sensitivity and ultrafast time resolution, having a probe depth of only a few nm and an instrument response less than 100 fs. Using this technique we investigated the ultrafast electron dynamics at a hematite (α-Fe 2 O 3 ) surface. Surface electron trapping and small polaron formation both occur in 660 fs following photoexcitation. These kinetics are independent of surface morphology indicating that electron trapping is not mediated by defects. Instead, small polaron formation is proposed as the likely driving force for surface electron trapping. We also show that in Fe 2 O 3 , Co 3 O 4 , and NiO, band gap excitation promotes electron transfer from O 2p valence band states to metal 3d conduction band states. In addition to detecting the photoexcited electron at the metal M 2,3 -edge, the valence band hole is directly observed as transient signal at the O L 1 -edge. The size of the resulting charge transfer exciton is on the order of a single metal–oxygen bond length. Spectral shifts at the O L 1 -edge correlate with metal–oxygen bond covalency, confirming the relationship between valence band hybridization and the overpotential for water oxidation. Furthermore, these examples demonstrate the unique ability to measure ultrafast electron dynamics with element and chemical state resolution using XUV-RA spectroscopy. Accordingly, this method is poised to play an important role to reveal chemical details of previously unseen surface electron dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Interplay between Photons, Canopy Structure, and Recollision Probability: A Review of the Spectral Invariants Theory of 3D Canopy Radiative Transfer Processes

Earth observations collected by remote sensors provide unique information to our ever-growing knowledge of the terrestrial biosphere. Yet, retrieving information from remote sensing data requires sophisticated processing and demands a better understanding of the underlying physics. This paper reviews research efforts that lead to the developments of the stochastic radiative transfer equation (RTE) and the spectral invariants theory. The former simplifies the characteristics of canopy structures with a pair-correlation function so that the 3D information can be succinctly packed into a 1D equation. The latter indicates that the interactions between photons and canopy elements converge to certain invariant patterns quantifiable by a few wavelength independent parameters, which satisfy the law of energy conservation. By revealing the connections between plant structural characteristics and photon recollision probability, these developments significantly advance our understanding of the transportation of radiation within vegetation canopies. They enable a novel physically-based algorithm to simulate the “hot-spot” phenomenon of canopy bidirectional reflectance while conserving energy, a challenge known to the classic radiative transfer models. Therefore, these theoretical developments have a far-reaching influence in optical remote sensing of the biosphere.

vegetation remote sensing; stochastic radiative tr↗

Comparison Between Mass Spectra of Individual Organic Particles Generated by UV Laser Ablation and in the IR/UV Two-Step Mode

One of the most fundamental aspects of single particle mass spectrometry is that the individual particle mass spectra are first classified and only then averaged. When ions are generated by ablation with a UV laser the mass spectra of particles with identical compositions exhibit large particle to particle fluctuations in the mass spectral intensity pattern. This is particularly true when it comes to particles containing organic molecules. At laser fluence that is sufficient to ionize sulfates many of the organic molecules exhibit high degree of fragmentation, often to the point where they cannot be distinguished from elemental carbon. In contrast, when ion generation is separated into two steps, in which the first step uses infra red to evaporate the semi-volatile components and the second, time delayed UV pulse to ionize the evaporating plume, the quality of the individual particle mass spectra are significantly improved. We present an experimental investigation of the properties and behavior of individual particle mass spectra of organic particles that are generated by ablation and in two steps. We investigate the effect of UV laser fluence and the delay between the two lasers. The study shows that the two step approach yields highly reproducible mass spectra that contain sufficient detail to allow clear molecular assignments. The two step approach also produces 10 times as many ions, and the mass spectral intensity can be related to the amount of organics in the particle. In contrast, ablation generated mass spectra were found to exhibit high degree of fragmentation and particle-to-particle fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of Low-Complexity Spectrally Selective One-Dimensional Mirrors for Photovoltaic Thermal Management

Operation at elevated temperatures is detrimental to the performance of crystalline Si solar modules. One method of reducing module operating temperature is selective reflection of sub-bandgap photons, which can otherwise only be absorbed parasitically. We numerically optimize the design of a series of multilayer photonic mirrors based on real materials using a previously developed optimization routine. Combined ray tracing and finite element simulations reveal the ability of each mirror to increase energy yield and decrease operating temperature. The best design outperforms a conventional glass antireflection coating, contains only nine layers, and maintains performance regardless of geographic location.

14 SOLAR ENERGY↗

Weak Production of Strange and Charmed Ground-State Baryons in Nuclei

We present results for the quasielastic weak production of Λ and Σ hyperons induced by ν¯ scattering off nuclei in the kinematical region of interest for accelerator neutrino experiments. We employ realistic hole spectral functions and we describe the propagation of the hyperons in the nuclear medium by means of a Monte Carlo cascade. The latter strongly modifies the kinematics and the relative production rates of the hyperons, leading to a nonvanishing Σ+ cross section, to a sizable enhancement of the Λ production and to a drastic reduction of the Σ0 and Σ− distributions. We also compute the quasielastic weak Λc production cross section, paying special attention to estimate the uncertainties induced by the model dependence of the vacuum n→Λc weak matrix element. In this regard, the recent BESIII measurements of the branching ratios of Λc→Λl+νl (l=e,μ) are used to benchmark the available theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel von Hamos spectrometer for efficient X-ray emission spectroscopy in the laboratory

We present a novel, highly efficient von Hamos spectrometer for X-ray emission spectroscopy (XES) in the laboratory using highly annealed pyrolitic graphite crystals as the dispersive element. The spectrometer covers an energy range from 2.5 keV to 15 keV giving access to chemical speciation and information about the electronic configuration of 3d transition metals by means of the Kβ multiplet. XES spectra of Ti compounds are presented to demonstrate the speciation capabilities of the instrument. A spectral resolving power of E/ΔE = 2000 at 8 keV was achieved. Typical acquisition times range from 10 min for bulk material to hours for thin samples below 1 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗