Flaw Tolerance in Lap Shear Brazed Joints

Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

Flom, Yury↗

Probabilistic Fracture Mechanics Analysis of the Orbiter's LH2 Feedline Flowliner

Work performed by Southwest Research Institute (SwRI) as part of an Independent Technical Assessment (ITA) for the NASA Engineering and Safety Center (NESC) is summarized. The ITA goal was to establish a flight rationale in light of a history of fatigue cracking due to flow induced vibrations in the feedline flowliners that supply liquid hydrogen to the space shuttle main engines. Prior deterministic analyses using worst-case assumptions predicted failure in a single flight. The current work formulated statistical models for dynamic loading and cryogenic fatigue crack growth properties, instead of using worst-case assumptions. Weight function solutions for bivariant stressing were developed to determine accurate crack "driving-forces". Monte Carlo simulations showed that low flowliner probabilities of failure (POF = 0.001 to 0.0001) are achievable, provided pre-flight inspections for cracks are performed with adequate probability of detection (POD)-specifically, 20/75 mils with 50%/99% POD. Measurements to confirm assumed POD curves are recommended. Since the computed POFs are very sensitive to the cyclic loads/stresses and the analysis of strain gage data revealed inconsistencies with the previous assumption of a single dominant vibrant mode, further work to reconcile this difference is recommended. It is possible that the unaccounted vibrational modes in the flight spectra could increase the computed POFs.

Bonacuse, Peter J.↗

The Potential of Water Vapor & Precipitation Estimation with a Differential-frequency Radar

In the presence of rain, the radar return powers from a three-frequency radar, with center frequency at 22.235 GHz and upper and lower frequencies chosen with equal water vapor absorption coefficients, can be used to estimate water vapor density and parameters of the precipitation. A linear combination of differential measurements between the center and lower frequencies on one hand and the upper and lower frequencies on the other provide an estimate of differential water vapor absorption. Conversely, the difference in radar reflectivity factors (in dB) between the upper and lower frequencies is independent of water vapor absorption and can be used to estimate the median mass diameter of the hydrometeors. For a down-looking radar, path-integrated estimates of water vapor absorption may be possible under rain-free as well as raining conditions by using the surface returns at the three frequencies. Cross-talk or interference between the precipitation and water vapor estimates depends on the frequency separation of the channels as well as on the phase state and the median mass diameter of the hydrometeors. Simulations of the retrieval of water vapor absorption show that the largest source of variability arises from the variance in the measured radar return powers while the largest biases occur in the mixed-phase region. Use of high pulse repetition frequencies and signal whitening methods may be needed to obtain the large number of independent samples required. Measurements over a fractional bandwidth, defined as the ratio of the difference between the upper and lower frequencies to the center frequency, up to about 0.2 should be passible in a differential frequency mode, where a single transceiver and antenna are used. Difficulties in frequency allocation may require alternative choices of frequency where the water vapor absorptions at the low and high frequencies are unequal. We consider the degradation in the retrieval accuracy when the frequencies are not optimum.

Meneghini, Robert↗

Development of a User Interface for a Regression Analysis Software Tool

An easy-to -use user interface was implemented in a highly automated regression analysis tool. The user interface was developed from the start to run on computers that use the Windows, Macintosh, Linux, or UNIX operating system. Many user interface features were specifically designed such that a novice or inexperienced user can apply the regression analysis tool with confidence. Therefore, the user interface s design minimizes interactive input from the user. In addition, reasonable default combinations are assigned to those analysis settings that influence the outcome of the regression analysis. These default combinations will lead to a successful regression analysis result for most experimental data sets. The user interface comes in two versions. The text user interface version is used for the ongoing development of the regression analysis tool. The official release of the regression analysis tool, on the other hand, has a graphical user interface that is more efficient to use. This graphical user interface displays all input file names, output file names, and analysis settings for a specific software application mode on a single screen which makes it easier to generate reliable analysis results and to perform input parameter studies. An object-oriented approach was used for the development of the graphical user interface. This choice keeps future software maintenance costs to a reasonable limit. Examples of both the text user interface and graphical user interface are discussed in order to illustrate the user interface s overall design approach.

Ulbrich, Norbert Manfred↗

NASA Tech Briefs, November 2010

Topics covered include: Portable Handheld Optical Window Inspection Device; Salience Assignment for Multiple-Instance Data and Its Application to Crop Yield Prediction; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems ; Predicting Long-Range Traversability from Short-Range Stereo-Derived Geometry; Browser-Based Application for Telemetry Monitoring of Robotic Assets; Miniature Low-Noise G-Band I-Q Receiver; Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers; Differential Resonant Ring YIG Tuned Oscillator; Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines; Reducing Seal Adhesion in Low Impact Docking Systems; Optimal Flow Control Design; Corrosion-Resistant Container for Molten-Material Processing; Reusable Hot-Wire Cable Cutter; Deployment of a Curved Truss; High-Volume Airborne Fluids Handling Technologies to Fight Wildfires; Modeling of Alkane Oxidation Using Constituents and Species; Fabrication of Lanthanum Telluride 14-1-11 Zintl High-Temperature Thermoelectric Couple; A Computer Model for Analyzing Volatile Removal Assembly; Analysis of Nozzle Jet Plume Effects on Sonic Boom Signature; Optical Sidebands Multiplier; Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers; Self-Nulling Beam Combiner Using No External Phase Inverter; Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis; Maximum Likelihood Time-of-Arrival Estimation of Optical Pulses via Photon-Counting Photodetectors; Handheld White Light Interferometer for Measuring Defect Depth in Windows; Decomposition Algorithm for Global Reachability on a Time-Varying Graph; Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids; Efficient Web Services Policy Combination; Using CTX Image Features to Predict HiRISE-Equivalent Rock Density; Isolation of the Paenibacillus phoenicis, a Spore-Forming Bacterium; Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy; Cell Radiation Experiment System; Process to Produce Iron Nanoparticle Lunar Dust Simulant Composite; Inversion Method for Early Detection of ARES-1 Case Breach Failure; Use of ILTV Control Laws for LaNCETS Flight Research;and Evaluating Descent and Ascent Trajectories Near Non-Spherical Bodies.

Source record↗

Fundamental Limit of 1/f Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise

So-called 1/f noise has power spectral density inversely proportional to frequency, and is observed in many physical processes. Single longitudinal-mode semiconductor lasers, used in variety of interferometric sensing applications, as well as coherent communications, exhibit 1/f frequency noise at low frequency (typically below 100kHz). Here we evaluate mechanical thermal noise due to mechanical dissipation in semiconductor laser components and give a plausible explanation for the widely-observed 1/f frequency noise, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Semiconductor-laser's short cavity, small beam radius, and lossy components are expected to emphasize thermal-noise-limited frequency noise. Our simple model largely explains the different 1/f noise levels observed in various semiconductor lasers, and provides a framework where the noise may be reduced with proper design.

Numata, K.↗

SEEDS Moving Groups and CHARIS Status Updates

We present the status update for the SEEDS Moving Groups category. To date, we have observed 59 targets and currently have more than 20 candidates. We also present the expected scientific capabilities of CHARIS, the Coronagraphic High Angular Resolution Imaging Spectrograph, which is being built for the Subaru 8.2 m telescope of the National Astronomical Observatory of Japan. CHARIS will be implemented behind the new extreme adaptive optics system at Subaru, SCExAO, and the existing 188-actuator system AO188. CHARIS will offer three observing modes over near~infrared wavelengths from 0.9 to 2.4 microns (the y-, J-, H-, and K-bands), including a low-spectral-resolution mode covering this entire wavelength range and a high-resolution mode within a single band. With these capabilities, CHARIS will offer exceptional sensitivity for discovering giant exoplanets, and will enable detailed characterization of their atmospheres, CHARIS, the only planned high-contrast integral field spectrograph on an 8m-class telescope in the Northern Hemisphere, will complement the similar instruments such as Project 1640 at Palomar, and GPI and SPHERE in Chile.

McElwain, Michael↗

Development and Characterization of Embedded Sensory Particles Using Multi-Scale 3D Digital Image Correlation

A method for detecting fatigue cracks has been explored at NASA Langley Research Center. Microscopic NiTi shape memory alloy (sensory) particles were embedded in a 7050 aluminum alloy matrix to detect the presence of fatigue cracks. Cracks exhibit an elevated stress field near their tip inducing a martensitic phase transformation in nearby sensory particles. Detectable levels of acoustic energy are emitted upon particle phase transformation such that the existence and location of fatigue cracks can be detected. To test this concept, a fatigue crack was grown in a mode-I single-edge notch fatigue crack growth specimen containing sensory particles. As the crack approached the sensory particles, measurements of particle strain, matrix-particle debonding, and phase transformation behavior of the sensory particles were performed. Full-field deformation measurements were performed using a novel multi-scale optical 3D digital image correlation (DIC) system. This information will be used in a finite element-based study to determine optimal sensory material behavior and density.

Cornell, Stephen R.↗

The CheMin XRD on the Mars Science Laboratory Rover Curiosity: Construction, Operation, and Quantitative Mineralogical Results from the Surface of Mars

The Mars Science Laboratory mission was launched from Cape Canaveral, Florida on Nov. 26, 2011 and landed in Gale crater, Mars on Aug. 6, 2012. MSL's mission is to identify and characterize ancient "habitable" environments on Mars. MSL's precision landing system placed the Curiosity rover within 2 km of the center of its 20 X 6 km landing ellipse, next to Gale's central mound, a 5,000 meter high pile of laminated sediment which may contain 1 billion years of Mars history. Curiosity carries with it a full suite of analytical instruments, including the CheMin X-ray diffractometer, the first XRD flown in space. CheMin is essentially a transmission X-ray pinhole camera. A fine-focus Co source and collimator transmits a 50μm beam through a powdered sample held between X-ray transparent plastic windows. The sample holder is shaken by a piezoelectric actuator such that the powder flows like a liquid, each grain passing in random orientation through the beam over time. Forward-diffracted and fluoresced X-ray photons from the sample are detected by an X-ray sensitive Charge Coupled Device (CCD) operated in single photon counting mode. When operated in this way, both the x,y position and the energy of each photon are detected. The resulting energy-selected Co Kalpha Debye-Scherrer pattern is used to determine the identities and amounts of minerals present via Rietveld refinement, and a histogram of all X-ray events constitutes an X-ray fluorescence analysis of the sample.The key role that definitive mineralogy plays in understanding the Martian surface is a consequence of the fact that minerals are thermodynamic phases, having known and specific ranges of temperature, pressure and composition within which they are stable. More than simple compositional analysis, definitive mineralogical analysis can provide information about pressure/temperature conditions of formation, past climate, water activity and the like. Definitive mineralogical analyses are necessary to establish the origin or provenance of a sample. The search for evidence of extant or extinct life on Mars will initially be a search for evidence of present or past conditions supportive of life (e.g., evidence of water), not for life itself.Results of the first 1,000 sols (Mars days) will be discussed, including the discovery of the first habitable environment on Mars.

CheMin↗

Adaptable Single Active Loop Thermal Control System (TCS) for Future Space Missions

This presentation will examine the development of a thermal control system (TCS) for future space missions utilizing a single active cooling loop. The system architecture enables the TCS to be reconfigured during the various mission phases to respond, not only to varying heat load, but to heat rejection temperature as well. The system will consist of an accumulator, pump, cold plates (evaporators), condenser radiator, and compressor, in addition to control, bypass and throttling valves. For cold environments, the heat will be rejected by radiation, during which the compressor will be bypassed, reducing the system to a simple pumped loop that, depending on heat load, can operate in either a single-phase liquid mode or two-phase mode. For warmer environments, the pump will be bypassed, enabling the TCS to operate as a heat pump. This presentation will focus on recent findings concerning two-phase flow regimes, pressure drop, and heat transfer coefficient trends in the cabin and avionics micro-channel heat exchangers when using the heat pump mode. Also discussed will be practical implications of using micro-channel evaporators for the heat pump.

two phase heat transfer↗

Multi-Stage ADRs for Current and Future Astronomy Missions: Performance and Requirements for Cryogen-Free Operation

The cooling requirements for current (e.g. Astro-H) and future (e.g. IXO and ASP) astronomy missions pose significant challenges for the sub-Kelvin Cooler. In particular, the use of large detector arrays increases the cooling power needed, and the variety of cryocoolers that can be used for pre-cooling greatly expands the range of temperatures at which the sub-Kelvin cooler can be designed to reject heat. In most cases, there is also a need for a stable higher temperature stage for cooling amplifiers or telescope components. NASA/GSFC is currently building a 3-stage ADR for the Astro-H mission, and is developing a 5-stage ADR suitable for IXO and ASP, as well as many other missions in the early planning stages. The architecture of these ADRs allows them to be adapted rather easily for different cooling requirements and to accommodate different cryocooler capabilities (operating temperature and cooling power). This paper will discuss the performance of these ADRs, which operate in both continuous, and single-shot cooling modes, and the minimum cryocooler capabilities needed to meet the requirements of future missions.

Shirron, Peter↗

IXPE Mission System Concept and Development Status

The Goal of the Imaging X-Ray Polarimetry Explorer (IXPE) Mi SMEX), is to expand understanding of high-energy astrophysical processes and sources, in support of NASA’s first science objective in Astrophysics: “Discover how the universe works.” IXPE, an international collaboration, will conduct X-ray imaging polarimetry for multiple categories of cosmic X-ray sources such as neutron stars, stellar-mass black holes, supernova remnants and active galactic nuclei. The Observatory uses a single science operational mode capturing the X-ray data from the targets. The IXPE Observatory consists of spacecraft and payload modules built up in parallel to form the Observatory during system integration and test. The payload includes three X-ray telescopes each consisting of a polarization-sensitive, gas pixel X-ray detector, paired with its corresponding grazing incidence mirror module assembly (MMA). A deployable boom provides the correct separation (focal length) between the detector units (DU) and MMAs. These payload elements are supported by the IXPE spacecraft which is derived from the BCP-small spacecraft architecture. This paper summarizes the IXPE mission science objectives, updates the Observatory implementation concept including the payload and spacecraft ts and summarizes the mission status since last year’s conference.

Deininger, William D.↗

Simultaneous Temperature/Pressure Monitoring in Compressible Flows using Hybrid fs/ps Pure-Rotational CARS

We demonstrate simultaneous monitoring of temperature and pressure using a hybrid femtosecond/picosecond pure-rotational CARS technique in a one-dimensional line-imaging configuration. The method employs two detection channels and two 60-ps-duration probe laser beams with independently adjustable time delays from the broadband 35-fs pump/Stokes pulse. Simultaneous temperature and pressure monitoring is demonstrated along the centerline of a canonical under expanded compressible air jet flow emanating from a choked, sonic nozzle. Temperature is measured almost independently of pressure by analyzing CARS spectra obtained with a probe pulse near zero time delay for nearly collision-free acquisition. Pressure is obtained from spectra acquired with long probe time delays to sample the impact of gas-phase collisions. The CARS measurements were obtained in both time-averaged and single-laser-shot mode with 67 μm spatial resolution along the jet axis along a nominally 6-mm line. The measurements span a temperature and pressure range of T= 70-300 K and P= 0.05-1.2atm.

Sean P Kearney↗

Investigation of the Potential for Lidar & Polarimeter Combined Aerosol Retrievals Using Various Instrument Combinations

As a scientific community, we are motivated to achieve better observational capabilities for aerosols, to reduce uncertainties about aerosol’s role in climate. Encouraged by the National Academies Decadal Survey, many are looking to the synergy of lidar and polarimeter as a means of achieving improved measurements. Polarimetric observations of total-column radiances have excellent sensitivity to aerosol size distribution and absorption properties. Active lidar measurements have fewer wavelengths and view angles and therefore more limited sensitivity to aerosol microphysical properties such as complex refractive index. Yet the advantage of vertically resolved profiles is game-changing, especially given that models contain significant uncertainty about the vertical distribution of aerosol and that polarimeter and other passive retrievals must make assumptions about vertical distribution which can impact performance. To optimize the synergy, a joint polarimeter + lidar mission requires a joint retrieval. However, the exact instruments that will be launched on a future satellite are unknown, and the capabilities of polarimeters and lidars cover a large range. In this study, we perform information content analysis for a range of nominal instrument combinations. The methodology is ideal for assessing the impact of measurements and a priori information (assumptions and constraints) with respect to the desired retrieval products, and for comparing measurement systems. It has advantages that make it useful in advance of or in parallel with retrieval development, such as producing quantitatively useful comparisons even for retrieval scenarios that are significantly underdetermined and therefore impossible to retrieve without significant assumptions, and it is not impacted by retrieval-specific sources of error such as incomplete or incorrect convergence which can complicate the interpretation of a retrieval performance analysis. Here, we will derive the expected uncertainty in retrieved aerosol concentration, effective radius, fine mode fraction and single scattering albedo, for a combination of a polarimeter with various grades of lidar, from an elastic backscatter lidar, similar to the pathfinder CALIOP on the CALIPSO satellite, to a multi-wavelength high spectral resolution lidar.

Sharon P Burton↗

An LES Survey of Cold-Air Outbreaks Spanning ACTIVATE and COMBLE

Two recent field campaigns offer unique new opportunities to survey coupled aerosol and cloud processes operating within cold-air outbreaks (CAOs). NASA's 2019-2023 Aerosol Cloud meTeorology Interactions oVer the western Atlantic Experiment (ACTIVATE) project provided airborne in situ and remote sensing observations in multiple CAOs off the central US Eastern Seaboard. Contemporaneously, DOE's 2019-2020 Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) provided continuous ground-based in situ and remote sensing measurements during hundreds of hours of CAO conditions at two sites flanking the Norwegian Sea. Here we highlight lessons learned from contrasting sets of aerosol-aware Lagrangian large-eddy simulation case studies derived from each campaign, as well as outstanding uncertainties. Cases simulated include all of the most extensively sampled CAO flights during ACTIVATE, and a wide range of CAO strengths and mesoscale structures during COMBLE. Each case study is also suitable for simulation with large-scale models in single-column model mode or with a limited-domain approach using periodic boundary conditions. We seek to address the central question: what microphysical process pathways control the Lagrangian evolution of surface and top-of-atmosphere radiative fluxes under ACTIVATE and COMBLE conditions? Many science team members, co-investigators, and collaborators will be gratefully acknowledged in association with their contributions to making this work possible.

cold-air outbreaks↗

Microelectromechanical filter formed from parallel-connected lattice networks of contour-mode resonators

A microelectromechanical (MEM) filter is disclosed which has a plurality of lattice networks formed on a substrate and electrically connected together in parallel. Each lattice network has a series resonant frequency and a shunt resonant frequency provided by one or more contour-mode resonators in the lattice network. Different types of contour-mode resonators including single input, single output resonators, differential resonators, balun resonators, and ring resonators can be used in MEM filter. The MEM filter can have a center frequency in the range of 10 MHz-10 GHz, with a filter bandwidth of up to about 1% when all of the lattice networks have the same series resonant frequency and the same shunt resonant frequency. The filter bandwidth can be increased up to about 5% by using unique series and shunt resonant frequencies for the lattice networks.

42 ENGINEERING↗

Development of Advanced Radionuclide Gamma spectrOmeter-2 (ARGO-2) for Low-level Radionuclide Measurements

A low-level multidimensional gamma spectrometer was recently installed at Pacific Northwest National Laboratory, USA. The spectrometer utilizes a dual-detector design and advanced detection techniques, demonstrating superior detection efficiency/sensitivity. This work details integral components of the system, including the dual-detector design, its shielding, and cosmic veto panels for background reduction. Results from system’s operation in singles and coincidence mode are highlighted.

ARGO, Coincidence measurements, Multidimensional g↗