Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “relational databases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Sunlit Io Atmospheric [O I] 6300 A and the Plasma Torus

A large database of sunlit Io [O I] 6300A emission, acquired over the period 1990-1999, with extensive coverage of Io orbital phase angle phi and System III longitude lambda(sub III), exhibits significant long-term and short-term variations in [O I] 6300A emission intensities. The long-term average intensity shows a clear dependence on lambda(sub III), which establishes conclusively that the emission is produced by the interaction between Io's atmosphere and the plasma torus. Two prominent average intensity maxima, 70 deg to 90 deg wide, are centered at lambda(sub III) about 130deg. and about 295 deg. A comparison of data from October 1998 with a three-dimensional plasma torus model, based upon electron impact excitation of atomic oxygen, suggests a basis for study of the torus interaction with Io's atmosphere. The observed short-term, erratic [O I] 6300A intensity variations fluctuate approximately 20% to 50% on time scale of tens of minutes with less frequent fluctuations of a factor of about 2. The most likely candidate to produce these fluctuations is a time-variable energy flux of field-aligned nonthermal electrons identified recently in Galileo PLS data. If true, the short-term [O I] intensity fluctuations may be related to variable field-aligned currents driven by inward and outward torus plasma transport and/or transient high-latitude, field-aligned potential drops. A correlation between the intensity and emission line width indicates molecular dissociation may contribute significantly to the [O I] 6300A emission. The nonthermal electron energy flux may produce O(1-D) by electron impact dissociation of SO2 and SO, with the excess energy going into excitation of O and its kinetic energy. The [O I] 6300A emission database establishes Io as a valuable probe of the torus, responding to local conditions at Io's position.

Oliversen, Ronald J.↗

Integrase-on-Demand

SAND2025-07449O Integrase-on-Demand is a software tool that allows users to identify regions in genomic sequences where genetic material can be integrated with high probability. It uses a database of integrases and their DNA attachment sites to search against any genomic sequence, producing a list of open sites, the integrase sequence, and the source of the genomic island. The program requires MASH software to be available on the system. It consists of a main script and a precomputed input file, with a taxonomy mode that searches closely related genomes and a search mode that looks for identical attachment site matches in the integrase/attachment input file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Williams, Kelly [Sandia National Lab. (SNL-CA), Li↗

Monitoring cognitive function and need with the automated neuropsychological assessment metrics in Decompression Sickness (DCS) research

Hypobaric decompression sickness (DCS) research presents the medical monitor with the difficult task of assessing the onset and progression of DCS largely on the basis of subjective symptoms. Even with the introduction of precordial Doppler ultrasound techniques for the detection of venous gas emboli (VGE), correct prediction of DCS can be made only about 65 percent of the time according to data from the Armstrong Laboratory's (AL's) hypobaric DCS database. An AL research protocol concerned with exercise and its effects on denitrogenation efficiency includes implementation of a performance assessment test battery to evaluate cognitive functioning during a 4-h simulated 30,000 ft (9144 m) exposure. Information gained from such a test battery may assist the medical monitor in identifying early signs of DCS and subtle neurologic dysfunction related to cases of asymptomatic, but advanced, DCS. This presentation concerns the selection and integration of a test battery and the timely graphic display of subject test results for the principal investigator and medical monitor. A subset of the Automated Neuropsychological Assessment Metrics (ANAM) developed through the Office of Military Performance Assessment Technology (OMPAT) was selected. The ANAM software provides a library of simple tests designed for precise measurement of processing efficiency in a variety of cognitive domains. For our application and time constraints, two tests requiring high levels of cognitive processing and memory were chosen along with one test requiring fine psychomotor performance. Accuracy, speed, and processing throughout variables as well as RMS error were collected. An automated mood survey provided 'state' information on six scales including anger, happiness, fear, depression, activity, and fatigue. An integrated and interactive LOTUS 1-2-3 macro was developed to import and display past and present task performance and mood-change information.

Nesthus, Thomas E.↗

Technology utilization office data base analysis and design

NASA Headquarters is placing a high priority on the transfer of NASA and NASA contractor developed technologies and expertise to the private sector and to other federal, state and local government organizations. The ultimate objective of these efforts is positive economic impact, an improved quality of life, and a more competitive U.S. posture in international markets. The Technology Utilization Office (TUO) currently serves seven states with its technology transfer efforts. Since 1989, the TUO has handled over one-thousand formal requests for NASA related technologies assistance. The technology transfer process requires promoting public awareness of NASA related soliciting requests for assistance, matching technologies to specific needs, assuring appropriate technology transfer, and monitoring and evaluating the process. Each of these activities have one very important aspect in common: the success of each is dissemination of appropriate high quality information. The purpose of the research was to establish the requirements and develop a preliminary design for a database system to increase the effectiveness and efficiency of the TUO's technology transfer function. The research was conducted following the traditional systems development life cycle methodology and was supported through the use of modern structured analysis techniques. The next section will describe the research and findings as conducted under the life cycle approach.

Floyd, Stephen A.↗

Spacecraft potential effects on the Dynamics Explorer 2 satellite

The relationship between the plasma environment and spacecraft potential is examined for the Dynamics Explorer 2 (DE 2) spacecraft in an attempt to improve the accuracy of ion drift measurements by the retarding potential analyzer (RPA). Because of the DE 2 orbit characteristics (apogee near 1000 km and perigee near 300 km) and the configuration of conducting surfaces on the spacecraft, thermal electrons and ions constituted the only significant contributions to the charging currents to the spacecraft surface for the majority of geophysical conditions encountered. The geomagnetic field had considerable effect on the spacecraft potential due to magnetic field confinement of the electrons as well as to the V x B electric field resulting from the movement of the spacecraft across magnetic field lines. Using a database of inferred spacecraft potentials from the RPA, measured electron temperatures from the Langmuir probe (LANG), and calculated V x B electric fields, we derive an algorithm for determining the spacecraft potential (at the location of the RPA on the spacecraft) for any point of the DE 2 orbit. Knowledge of the spacecraft potential subsequently allows us to retrieve relatively accurate ion drifts from the RPA data.

Anderson, P. C.↗

XV-15 Low-Noise Terminal Area Operations Testing

Test procedures related to XV-15 noise tests conducted by NASA-Langley and Bell Helicopter Textron, Inc. are discussed. The tests. which took place during October and November 1995, near Waxahachie, Texas, documented the noise signature of the XV-15 tilt-rotor aircraft at a wide variety of flight conditions. The stated objectives were to: -provide a comprehensive acoustic database for NASA and U.S. Industry -validate noise prediction methodologies, and -develop and demonstrate low-noise flight profiles. The test consisted of two distinct phases. Phase 1 provided an acoustic database for validating analytical noise prediction techniques; Phase 2 directly measured noise contour information at a broad range of operating profiles, with emphasis on minimizing 'approach' noise. This report is limited to a documentation of the test procedures, flight conditions, microphone locations, meteorological conditions, and test personnel used in the test. The acoustic results are not included.

Edwards, B. D.↗

MSU Antenna Pattern Data

The Microwave Sounding Unit (MSU) antenna pattern data for nine MSU Flight Models (FMs) have been successfully rescued from 22-year old 7-track and 9-track magnetic tapes and cartridges. These antenna pattern data were unpacked into user-friendly ASCII format, and are potentially useful for making antenna pattern corrections to MSU antenna temperatures in retrieving the true brightness temperatures. We also properly interpreted the contents of the data and show how to convert the measured antenna signal amplitude in volts into relative antenna power in dB with proper normalization. It is found that the data are of high quality with a 60-dB drop in the co-polarized antenna patterns from the central peak value to its side-lobe regions at scan angles beyond 30 deg. The unpacked antenna pattern data produced in this study provide a useful database for data users to correct the antenna side-lobe contribution to MSU measurements. All of the data are available to the scientific community on a single CD-ROM.

Mo, Tsan↗

Anomalous Oxygen and Krypton Abundances in Interstellar Gas

The primary objective of this program was to obtain FUSE observations of the interstellar H2 absorption toward a sample of stars observed with the HST STIS spectrograph as part of the ISM SNAP Survey. This Survey was designed to produce a database of high quality, high resolution W spectra from which interstellar gas-phase elemental abundances could be derived for large portions of the Galaxy. In particular, oxygen and krypton were chosen as excellent tracers for measuring the homogeneity of the interstellar gas due to their weak depletion into dust grains. The gas-phase 0 and Kr abundances relative to total hydrogen column density had previously been shown with HST GHRS measurements to be essentially constant in the local Milky Way. One of the main motivations of the ISM SNAP Survey was to determine if this constancy held at greater distances and in denser sightlines (where depletion into dust could be a possibility). The initial ISM SNAP STIS observations indicated a number of sightlines with unusual 0 and Kr abundances relative to the measured H I column densities. Since the appropriate benchmark for accurate abundance comparisons is the total hydrogen column density (H I plus H2), FUSE observations of interstellar H2 were carried out in these sightlines in order to determine if they represent cases of true abundance anomalies.

Meyer, David M.↗

Tools for Performing SBG hyperspectral Observing System Simulation Experiment

One of NASA’s Decadal Survey mission, Surface Biology and Geology (SBG), will include a hyperspectral remote sensing imager, which has a very high spatial resolution and a wide spectral coverage (from UV to Near IR). Unprecedented large data volumes will be generated by the SBG hyperspectral instrument. Before the launch of the new satellite, an Observing System Simulation Experiment (OSSE) can be used to study different designs of the new satellite system. One of the key components in an OSSE study is a radiative transfer model (RTM) or forward model. In this presentation, we will describe a Principal Component-based Radiative Transfer Model (PCRTM) which is capable of simulating atmospheric (TOA) radiance or reflectance spectra from far IR to visible and UV spectral regions (50 wavenumber to 30000 wavenumber) quickly and accurately. Multiple scattering from multiple layers of clouds/aerosols are included in the model. The PCRTM has a very good accuracy relative to reference line-by-line radiative transfer models (LBLRTM), and it saves 3-4 orders of magnitude computational time relative to LBLRTM or MODTRAN. The PCRTM model has been successfully used to analyze large volumes of data from hyperspectral sensors such as AIRS, CrIS, and IASI. It has also been used to perform OSSE studies for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Another useful tool for the OSSE is surface Bidirectional Reflectance Distribution Function (BRDF) database. It is very crucial for the SBG OSSE to include realistic BRDF spectra. Currently, most of the surface reflectance spectra such as those in the ECOSIS and ECOSTRESS are measured at specific observation geometries. We have developed a hyperspectral bidirectional reflectance (HSBR) model which combines Ross-Li BRDF model with the existing reflectance spectral libraries using a principal component analysis. This HSBR model can provide realistic BRDF spectra under various observation conditions. It can also be used to generate realistic BRDF spectra using measurements from multi-band imagers or spectrometers such as MODIS or VIIRS.

Xu Liu↗

MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling

Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269–1274, 2016; Arch Dis Child 81.2:172–173, 1999) atlas. The evaluation of BAA can be a tedious and time-consuming process for the radiologist. As such, several computer-assisted detection/diagnosis (CAD) methods have been proposed for automation of BAA. Classical CAD tools have traditionally relied on hard-coded algorithmic features for BAA which suffer from a variety of drawbacks. Recently, the advent and proliferation of convolutional neural networks (CNNs) has shown promise in a variety of medical imaging applications. There have been at least two published applications of using deep learning for evaluation of bone age (Med Image Anal 36:41–51, 2017; JDI 1–5, 2017). However, current implementations are limited by a combination of both architecture design and relatively small datasets. The purpose of this study is to demonstrate the benefits of a customized neural network algorithm carefully calibrated to the evaluation of bone age utilizing a relatively large institutional dataset. In doing so, this study will aim to show that advanced architectures can be successfully trained from scratch in the medical imaging domain and can generate results that outperform any existing proposed algorithm. The training data consisted of 10,289 images of different skeletal age examinations, 8909 from the hospital Picture Archiving and Communication System at our institution and 1383 from the public Digital Hand Atlas Database. The data was separated into four cohorts, one each for male and female children above the age of 8, and one each for male and female children below the age of 10. The testing set consisted of 20 radiographs of each 1-year-age cohort from 0 to 1 years to 14–15+ years, half male and half female. The testing set included left-hand radiographs done for bone age assessment, trauma evaluation without significant findings, and skeletal surveys. A 14 hidden layer-customized neural network was designed for this study. The network included several state of the art techniques including residual-style connections, inception layers, and spatial transformer layers. Data augmentation was applied to the network inputs to prevent overfitting. A linear regression output was utilized. Mean square error was used as the network loss function and mean absolute error (MAE) was utilized as the primary performance metric. MAE accuracies on the validation and test sets for young females were 0.654 and 0.561 respectively. For older females, validation and test accuracies were 0.662 and 0.497 respectively. For young males, validation and test accuracies were 0.649 and 0.585 respectively. Finally, for older males, validation and test set accuracies were 0.581 and 0.501 respectively. The female cohorts were trained for 900 epochs each and the male cohorts were trained for 600 epochs. An eightfold cross-validation set was employed for hyperparameter tuning. Test error was obtained after training on a full data set with the selected hyperparameters. Using our proposed customized neural network architecture on our large available data, we achieved an aggregate validation and test set mean absolute errors of 0.637 and 0.536 respectively. To date, this is the best published performance on utilizing deep learning for bone age assessment. Our results support our initial hypothesis that customized, purpose-built neural networks provide improved performance over networks derived from pre-trained imaging data sets. We build on that initial work by showing that the addition of state-of-the-art techniques such as residual connections and inception architecture further improves prediction accuracy. This is important because the current assumption for use of residual and/or inception architectures is that a large pre-trained network is required for successful implementation given the relatively small datasets in medical imaging. Instead we show that a small, customized architecture incorporating advanced CNN strategies can indeed be trained from scratch, yielding significant improvements in algorithm accuracy. It should be noted that for all four cohorts, testing error outperformed validation error. One reason for this is that our ground truth for our test set was obtained by averaging two pediatric radiologist reads compared to our training data for which only a single read was used. This suggests that despite relatively noisy training data, the algorithm could successfully model the variation between observers and generate estimates that are close to the expected ground truth.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

miR-342-3p affects hepatocellular carcinoma cell proliferation via regulating NF-κB pathway

Recent research indicates that non-coding microRNAs (miRNAs) help regulate basic cellular processes in many types of cancer cells. We hypothesized that overexpression of miR-342-3p might affect proliferation of hepatocellular carcinoma (HCC) cells. After confirming overexpression of miR-342-3p with qRT-PCR, MTT assay showed that HCC cell proliferation was significantly inhibited by miR-342-3p, and that it significantly decreased BrdU-positive cell proliferation by nearly sixfold. Searching for targets using three algorithms we found that miR-342-3p is related to the NF-κB pathway and luciferase assay found that IKK-γ, TAB2 and TAB3 are miR-342-3p target genes. Results of western blot on extracted nuclear proteins of HepG2 and HCT-116 cells showed that miR-342-3p reduced and miR-342-3p-in increased p65 nuclear levels and qRT-PCR found that NF-κB pathway downstream genes were downregulated by miR-342-3p and upregulated by miR-342-3p-in, confirming that miR-342 targets NF-κB pathway. Overexpression of Ikk-γ, TAB2 and TAB3 partially rescued HCC cells proliferation inhibited by miR-342-3p. Using the GSE54751 database we evaluated expression from 10 HCC samples, which strongly suggested downregulation of miR-342-3p and we also found inverse expression between miR-342-3p and its targets IKK-γ, TAB2 and TAB3 from 71 HCC samples. Our results show that miR-342-3p has a significant role in HCC cell proliferation and is suitable for investigation of therapeutic targets. - Highlights: • MiR-342-3p suppresses hepatocellular carcinoma cell proliferation. • MiR-342-3p targets IKK-γ, TAB2 and TAB3 genes. • MiR-342-3p downregulates NF-kB signaling pathway. • MiR-342-3p is downregulated in clinical hepatocellular carcinoma samples. • The expression of miR-342-3p and its target gene is inversely related.

60 APPLIED LIFE SCIENCES↗

Report Series: Finding of Effect and Mitigation Documentation for Building 23-W10, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

Finding of Effect: The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-W10 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15228), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-W10, a supply warehouse, was installed in Mercury in 1962 (NNSS GIS Database) and served as a support facility for nuclear testing throughout much of the Cold War. It was likely produced during World War II (WWII) and previously installed at Camp Desert Rock. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource #D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-W10 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-W10 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD, such as warehouses, but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-W10 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation: The purpose of this letter report is to support the mitigation of the demolition of Building 23-W10 (Nevada State Historic Preservation Office [SHPO] Resource No. B15228) in the Mercury Historic District (MHD, SHPO Resource #D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The warehouse is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Entropy-driven melting point depression in fcc HEAs

High Entropy Alloys (HEAs) are an increasingly dominant alloy design paradigm. The premise of entropic stabilization of single-phase alloys has motivated much of the research on HEAs. Chemical complexity may indeed help stabilize single alloy phases relative to other lower-entropy competing solid phases. Paradoxically, this complexity may de-stabilize these alloys against the liquid phase, potentially limiting the application space of HEAs at elevated temperatures. In this work, we carry out a comprehensive investigation of the phase stability in the fcc CoCrFeMnNiV-Al HEA space using a state of the art CALPHAD database. By using modern visualization techniques and statistical analysis we examine the trade-off between chemical complexity and stability against the liquid state and identify a potentially difficult to overcome barrier for development of high temperature alloys, at least within the conventional fcc HEA space. Here, limited experimental data seem to be consistent with this analysis.

36 MATERIALS SCIENCE↗

Improved Annotation of Untargeted Metabolomics Data through Buffer Modifications That Shift Adduct Mass and Intensity

Annotation of untargeted high-resolution full-scan LC-MS metabolomics data remains challenging due to individual metabolites generating multiple LC-MS peaks arising from isotopes, adducts and fragments. Adduct annotation is a particular challenge, as the same mass difference between peaks can arise from adduct formation, fragmentation, or different biological species. To address this, here we describe a Buffer Modification Workflow (BMW), in which the same sample is run by LC-MS in both liquid chromatography solvent with 14 NH 3 -acetate buffer, and in solvent with the buffer modified with 15 NH 3 -formate. Buffer switching results in characteristic mass and signal intensity changes for adduct peaks, facilitating their annotation. This relatively simple and convenient chromatography modification annotated yeast metabolomics data with similar effectiveness to growing the yeast in isotope-labeled media. Application to mouse liver data annotated both known metabolite and known adduct peaks with 95% accuracy. Altogether, it identified 26% of ~ 27,000 liver LC-MS features as putative metabolites, of which ~ 2600 showed HMDB or KEGG database formula match. This workflow is well-suited to biological samples that cannot be readily isotope labeled, including plants, mammalian tissues, and tumors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative-capture cross sections for the La 139 ( n , γ ) reaction using thermal neutrons and structural properties of La 140

A set of prompt partial γ-ray production cross sections from thermal neutron capture were measured for the La 139 ( n , γ ) reaction using a guided beam of subthermal (thermal and cold) neutrons incident on a nat La 2 O 3 target at the Prompt Gamma Activation Analysis facility of the Budapest Research Reactor. Absolute La 140 cross sections were determined relative to the well-known comparator 35 Cl(n,γ) cross sections from the irradiation of a stoichiometric nat LaCl 3 sample. Here, the total cross section for radiative thermal neutron capture on La 139 from the sum of experimentally measured cross sections observed to directly feed the La 140 ground state was determined to be $σ$ $^{expt}_{0}$ = 8.58 (50) b.

139La(n, γ), E=thermal and cold↗

Ultraviolet Fluorescence Imaging for Photovoltaic Module Metrology: Best Practices and Survey of Features Observed in Fielded Modules

As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.

14 SOLAR ENERGY↗

Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation

Purpose: An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). Methods: The proposed MAR algorithm followed a four-step procedure. The first step involved applying a weighted blend of both DECT scans (I {sub H/L}) to generate a new image (I {sub Mix}). This action minimized Hounsfield unit (HU) variations surrounding the brachytherapy seeds. In the second step, the mean HU of the prostate in I {sub Mix} was calculated and shifted toward the mean HU of the two original DECT images (I {sub H/L}). The third step involved smoothing the newly shifted I {sub Mix} and the two original I {sub H/L}, followed by a subtraction of both, generating an image that represented the metallic artifact (I {sub A,(H/L)}) of reduced noise levels. The final step consisted of subtracting the original I {sub H/L} from the newly generated I {sub A,(H/L)} and obtaining a final image corrected for metallic artifacts. Following the completion of the algorithm, a DECT stoichiometric method was used to extract the relative electronic density (ρ{sub e}) and effective atomic number (Z {sub eff}) at each voxel of the corrected scans. Tissue assignment could then be determined with these two newly acquired physical parameters. Each voxel was assigned the tissue bearing the closest resemblance in terms of ρ{sub e} and Z {sub eff}, comparing with values from the ICRU 42 database. A MC study was then performed to compare the dosimetric impacts of alternative MAR algorithms. Results: An improvement in tissue assignment was observed with the DECT MAR algorithm, compared to the single-energy computed tomography (SECT) approach. In a phantom study, tissue misassignment was found to reach 0.05% of voxels using the DECT approach, compared with 0.40% using the SECT method. Comparison of the DECT and SECT D {sub 90} dose parameter (volume receiving 90% of the dose) indicated that D {sub 90} could be underestimated by up to 2.3% using the SECT method. Conclusions: The DECT MAR approach is a simple alternative to reduce metallic artifacts found in LDRB patient scans. Images can be processed quickly and do not require the determination of x-ray spectra. Substantial information on density and atomic number can also be obtained. Furthermore, calcifications within the prostate are detected by the tissue assignment algorithm. This enables more accurate, patient-specific MC dose calculations.

60 APPLIED LIFE SCIENCES↗

Coupled Approximation of U.S. Driving Speed and Volume Statistics using Spatial Conflation and Temporal Disaggregation

The advent of mobile devices with embedded global positioning systems has allowed commercial providers of real-time traffic data to develop highly accurate estimates of network-level vehicle speeds. Traffic speed data have far outpaced the availability and accuracy of real-time traffic volume information. Limited to a relatively small number of permanent and temporary traffic counters in any city, traffic volumes typically only cover a handful of roadways, with inconsistent temporal resolution. This work addressed this data gap by coupling a commercial data set of typical traffic speeds (by roadway and time of week) from TomTom to the U.S. Federal Highway Administration's Highway Performance Monitoring System database of annual average daily traffic (AADT) counts by roadway. This work is technically novel in its solution for establishing a national crosswalk between independent network geometries using spatial conflation and big data techniques. The resulting product is a national data set providing traffic speed and volume estimates under typical conditions for all U.S. roadways with AADT values.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗