Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

The Tables of Aerosol Optics (TAO) Project

The Table of Aerosol Optics (TAO) project is a community repository of optics computations (extinction, absorption, single-scatter albedo, lidar ratio, etc) that are useful for global models and remote sensing applications. TAO expands upon historical efforts (e.g., Hess et al., 1998) by building an open database that uses recent measurements and new computational techniques for non-spherical particles. The ‘open’ aspect of TAO is important, since the size distributions, hygroscopicities, refractive indices, and morphological recommendations of today will undoubtedly yield to different values in the future; the open framework of TAO allows scientists to keep adding new computations to the database as the science evolves. TAO is meant to be a community repository where specialists can put their computations for other scientists to use. So for instance, some groups are advancing new techniques that can accommodate complex fractal aggregates of black carbon, other groups are working on realistic irregular shapes for mineral dust, and different groups are updating the hygroscopicity of various aerosol types using new techniques. The TAO database gives these scientists a place to distribute their products. As TAO grows, modelers and remote sensing specialists will look to TAO as a place to find a wide variety of choices for testing. Meanwhile, global modelers can also use TAO to lobby for new tables that accommodate their needs. Eventually, TAO will provide mass extinction coefficients, mass absorption coefficients, lidar ratios, etc., at popular remote sensing and global modeling wavelengths (0.25-40 µm) for all pertinent species (sulfate, sea salt, BC, OC, BrC, dust, etc.). TAO will also accept computations for aerosol ‘type’ (e.g., biomass burning, urban, background, etc.) that may include regional and seasonal variability. Multiple tables may be created for each species or type to account for the multiple valid size distributions, hygroscopicities, complex refractive indices, and shapes that can be found in the literature.

Greg Schuster↗

The Tables of Aerosol Optics (TAO) Project

The Table of Aerosol Optics (TAO) project is a community repository of optics computations (extinction, absorption, single-scatter albedo, lidar ratio, etc) that are useful for global models and remote sensing applications. TAO expands upon historical efforts (e.g., Hess et al., 1998) by building an open database that uses recent measurements and new computational techniques for non-spherical particles. The ‘open’ aspect of TAO is important, since the size distributions, hygroscopicities, refractive indices, and morphological recommendations of today will undoubtedly yield to different values in the future; the open framework of TAO allows scientists to keep adding new computations to the database as the science evolves. TAO is meant to be a community repository where specialists can put their computations for other scientists to use. So for instance, some groups are advancing new techniques that can accommodate complex fractal aggregates of black carbon, other groups are working on realistic irregular shapes for mineral dust, and different groups are updating the hygroscopicity of various aerosol types using new techniques. The TAO database gives these scientists a place to distribute their products. As TAO grows, modelers and remote sensing specialists will look to TAO as a place to find a wide variety of choices for testing. Meanwhile, global modelers can also use TAO to lobby for new tables that accommodate their needs. Eventually, TAO will provide mass extinction coefficients, mass absorption coefficients, lidar ratios, etc., at popular remote sensing and global modeling wavelengths (0.25-40 µm) for all pertinent species (sulfate, sea salt, BC, OC, BrC, dust, etc.). TAO will also accept computations for aerosol ‘type’ (e.g., biomass burning, urban, background, etc.) that may include regional and seasonal variability. Multiple tables may be created for each species or type to account for the multiple valid size distributions, hygroscopicities, complex refractive indices, and shapes that can be found in the literature.

Elisabeth Andrews↗

Cryolite Overcoated Aluminum Reflectors for Far-Ultraviolet Spectroscopy

Aluminum (Al) mirrors are conventionally protected with metal-fluoride coatings (e.g., MgF 2 , LiF, or AlF 3 ) immediately after deposition to prevent oxidation and preserve its far-ultraviolet (FUV) spectral efficiency. However, the resulting FUV reflectance of the aluminum reflector is limited by the metal-fluoride overcoat film index of refraction, morphology, stoichiometry, and its absorption cut-off in the lower end of the FUV spectra. Cryolite (sodium hexafluoroaluminate, Na 3 AlF 6 ) emerges as a potential candidate to preserve the aluminum FUV reflectance due to its relatively lower index of refraction in the visible to ultraviolet; therefore, allowing for the thin-film design of highly spectral efficient reflectors over a wide spectral range. We investigate the use of cryolite in aluminum reflector FUV coating design. The deposited aluminum reflector overcoated with cryolite will be examined in terms of spectral efficiency and environmental durability. The deposited cryolite overcoat will be evaluated in terms of optical constants and structural properties. Preliminary results have shown that the use of cryolite as an overcoat to protect aluminum would yield unprecedented results as an optimal Hydrogen Lyman-alpha (HLyα) spectral line reflector, with experimental reflectance values >96%.

optical coating↗

Cryolite Overcoated Aluminum Reflectors for Far-Ultraviolet Spectroscopy

Aluminum (Al) mirrors are conventionally protected with metal-fluoride coatings (e.g., MgF2, LiF, or AlF3) immediately after deposition to prevent oxidation and preserve its far-ultraviolet (FUV) spectral efficiency. However, the resulting FUV reflectance of the aluminum reflector is limited by the metal-fluoride overcoat film index of refraction, morphology, stoichiometry, and its absorption cut-off in the lower end of the FUV spectra. Cryolite (sodium hexafluoroaluminate, Na3AlF6) emerges as a potential candidate to preserve the aluminum FUV reflectance due to its relatively lower index of refraction in the visible to ultraviolet; therefore, allowing for the thin-film design of highly spectral efficient reflectors over a wide spectral range. We investigate the use of cryolite in aluminum reflector FUV coating design. The deposited aluminum reflector overcoated with cryolite will be examined in terms of spectral efficiency and environmental durability. The deposited cryolite overcoat will be evaluated in terms of optical constants and structural properties. Preliminary results have shown that the use of cryolite as an overcoat to protect aluminum would yield unprecedented results as an optimal Hydrogen Lyman-alpha (HLyα) spectral line reflector, with experimental reflectance values >96%.

optical coatings↗

The Tables of Aerosol Optics (TAO) Project

The Table of Aerosol Optics (TAO) project is a community repository of optics computations (extinction, absorption, single-scatter albedo, lidar ratio, etc) that are useful for global models and remote sensing applications. TAO expands upon historical efforts (e.g., Hess et al., 1998) by building an open database that uses recent measurements and new computational techniques for non-spherical particles. The ‘open’ aspect of TAO is important, since the size distributions, hygroscopicities, refractive indices, and morphological recommendations of today will undoubtedly yield to different values in the future; the open framework of TAO allows scientists to keep adding new computations to the database as the science evolves. TAO is meant to be a community repository where specialists can put their computations for other scientists to use. So for instance, some groups are advancing new techniques that can accommodate complex fractal aggregates of black carbon, other groups are working on realistic irregular shapes for mineral dust, and different groups are updating the hygroscopicity of various aerosol types using new techniques. The TAO database gives these scientists a place to distribute their products. As TAO grows, modelers and remote sensing specialists will look to TAO as a place to find a wide variety of choices for testing. Meanwhile, global modelers can also use TAO to lobby for new tables that accommodate their needs. Eventually, TAO will provide mass extinction coefficients, mass absorption coefficients, lidar ratios, etc., at popular remote sensing and global modeling wavelengths (0.25-40 µm) for all pertinent species (sulfate, sea salt, BC, OC, BrC, dust, etc.). TAO will also accept computations for aerosol ‘type’ (e.g., biomass burning, urban, background, etc.) that may include regional and seasonal variability. Multiple tables may be created for each species or type to account for the multiple valid size distributions, hygroscopicities, complex refractive indices, and shapes that can be found in the literature.

Greg Schuster↗

Nanolaser spectroscopy and micro-optical resonators for detecting, analyzing, and manipulating bioparticles

This invention provides a new method for rapidly analyzing single bioparticles to assess their material condition and state of health. The method is enabled by use of a resonant cavity apparatus to measure an optical property related to the bioparticle size and refractive index. Measuring the refractive index is useful for determining material properties of the bioparticle. The material properties depend on the biomolecular composition of the bioparticle. The biomolecular composition is, in turn, dependent on the state of health of the bioparticle. Thus, measured optical properties can be used to differentiate normal (healthy) and abnormal (diseased) states of bioparticles derived from cells or tissues. The method is illustrated with data obtained from a resonator with a gain medium. The invention also provides new methods for making multiple measurements in a single device and detecting, analyzing, and manipulating bioparticles that are much smaller than the wavelength of light.

47 OTHER INSTRUMENTATION↗

Laser diode package with enhanced cooling

This invention provides a new method for rapidly analyzing single bioparticles to assess their material condition and state of health. The method is enabled by use of a resonant cavity apparatus to measure an optical property related to the bioparticle size and refractive index. Measuring the refractive index is useful for determining material properties of the bioparticle. The material properties depend on the biomolecular composition of the bioparticle. The biomolecular composition is, in turn, dependent on the state of health of the bioparticle. Thus, measured optical properties can be used to differentiate normal (healthy) and abnormal (diseased) states of bioparticles derived from cells or tissues. The method is illustrated with data obtained from a resonator with a gain medium. The invention also provides new methods for making multiple measurements in a single device and detecting, analyzing, and manipulating bioparticles that are much smaller than the wavelength of light.

47 OTHER INSTRUMENTATION↗

An Approximate Analytic Expression for the Flux Density of Scintillation Light at the Photocathode

The flux density of light exiting scintillator crystals is an important factor affecting the performance of radiation detectors, and is of particular importance for position sensitive instruments. Recent work by T. Woldemichael developed an analytic expression for the shape of the light spot at the bottom of a single crystal [1]. However, the results are of limited utility because there is generally a light pipe and photomultiplier entrance window between the bottom of the crystal and the photocathode. In this study, we expand Woldemichael s theory to include materials each with different indices of refraction and compare the adjusted light spot shape theory to GEANT 4 simulations [2]. Additionally, light reflection losses from index of refraction changes were also taken into account. We found that the simulations closely agree with the adjusted theory.

Braverman, Joshua B↗

Off-Angle Iris Correction using a Biological Model

This work implements an eye model to simulate corneal refraction effects. Using this model, ray tracing is performed to calculate transforms to remove refractive effects in off-angle iris images when reprojected to a frontal view. The correction process is used as a preprocessing step for off-angle iris images for input to a commercial matcher. With this method, a match score distribution mean improvement of 11.65% for 30 degree images, 44.94% for 40 degree images, and 146.1% improvement for 50 degree images is observed versus match score distributions with unmodi ed images.

Thompson, Joseph T↗

Method of analysis of polymerizable monomeric species in a complex mixture

Method of selective quantitation of a polymerizable monomeric species in a well spacer fluid, said method comprising the steps of adding at least one solvent having a refractive index of less than about 1.33 to a sample of the complex mixture to produce a solvent phase, and measuring the refractive index of the solvent phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method to create gradient index in a polymer

Novel photo-writable and thermally switchable polymeric materials exhibit a refractive index change of .DELTA.n.gtoreq.1.0 when exposed to UV light or heat. For example, lithography can be used to convert a non-conjugated precursor polymer to a conjugated polymer having a higher index-of-refraction. Further, two-photon lithography can be used to pattern high-spatial frequency structures.

36 MATERIALS SCIENCE↗

Methods and apparatus for controlling dispersions of nanoparticles

Electrically reconfigurable metamaterial with spatially varied refractive index is proposed for applications such as optical devices and lenses. The apparatus and method comprises a metamaterial in which the refractive indices are modified in space and time by applying one or more electric fields. The metamaterials are electrically controllable and reconfigurable, and consist of metal (gold, silver, etc.) particles of different shapes, such as rods, with dimension much smaller than the wavelength of light, dispersed in a dielectric medium. The metamaterial is controlled by applying a non-uniform electric field that causes two effects: (1) It aligns the metallic anisometric particles with respect to the direction of the applied electric field and (2) It redistributes particles in space, making their local concentration position dependent.

36 MATERIALS SCIENCE↗

Ultrafast transient grating radiation to optical image converter

A high sensitivity transient grating ultrafast radiation to optical image converter is based on a fixed transmission grating adjacent to a semiconductor substrate. X-rays or optical radiation passing through the fixed transmission grating is thereby modulated and produces a small periodic variation of refractive index or transient grating in the semiconductor through carrier induced refractive index shifts. An optical or infrared probe beam tuned just below the semiconductor band gap is reflected off a high reflectivity mirror on the semiconductor so that it double passes therethrough and interacts with the radiation induced phase grating therein. A small portion of the optical beam is diffracted out of the probe beam by the radiation induced transient grating to become the converted signal that is imaged onto a detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frontal view reconstruction for iris recognition

Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

97 MATHEMATICS AND COMPUTING↗

Imaging based refractometers

Refractometers for simultaneously measuring refractive index of a sample over a range or wavelengths of light include dispersive and focusing optical systems. An optical beam including the rang of wavelengths is spectrally spread along a first axis and focused along a second axis so as to be incident to an interface between the sample and a prism at a range of angles of incidence including a critical angle for at least one wavelength. In some cases, the prism can have a triangle, parallelogram, trapezoid, or other shape. In some cases, the optical beam can be reflected off of multiple interfaces between the prism and the sample. An imaging detector is situated to receive the spectrally spread and focused light from the interface and form an image corresponding to angle of incidence as a function of wavelength. One or more critical angles are indentified and corresponding refractive indices are determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Off-Angle Iris Correction using a Biological Model

This work implements an eye model to simulate corneal refraction effects. Using this model, ray tracing is performed to calculate transforms to remove refractive effects in off-angle iris images when reprojected to a frontal view. The correction process is used as a preprocessing step for off-angle iris images for input to a commercial matcher. With this method, a match score distribution mean improvement of 11.65% for 30 degree images, 44.94% for 40 degree images, and 146.1% improvement for 50 degree images is observed versus match score distributions with unmodified images.

Santos-Villalobos, Hector J↗