Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

Phase-shifted Bragg gratings in a foundry silicon nitride platform

Bragg gratings are key optical elements for applications in communications, sensing, and lasers. Phase-shifted Bragg gratings are a special case where the simple periodic structure is altered to allow a narrow spectral passband within the optical bandgap. Here, we demonstrate phase-shifted silicon nitride gratings fabricated using 193 nm deep ultraviolet lithography (DUV) on the AIM Photonics 300 mm silicon photonics foundry line. We measure the grating properties and verify the results with a transfer-matrix method (TMM) model. The standard grating expressions for extracting the coupling coefficient κ and bandwidth do not apply and are updated to account for the phase shift. These results inform future designs for on-chip grating filters and distributed feedback (DFB) lasers.

Husko, Chad (ORCID:0000000271252518)↗

Mini-Channel Flow Boiling in 1g and μg

Subcooled flow boiling combines complex processes governed by a strong coupling of heat and mass transfer, hydrodynamics, and liquid-vapor transitions. The gravitational body force plays an important role in these processes. By exploiting the latent heat of vaporization, subcooled flow boiling can transfer up to several orders-of-magnitude more heat compared to forced liquid flow. It is widely used in Earth-based thermal equipment to reduce the cost, size, and power required to move heat. Subcooled flow boiling is now considered a promising technology for space applications since it offers a means to control the motion of bubbles near the heated surface and thereby enhance nucleate boiling. However, a lack of data and predictive models on the role that gravity plays in these phenomena hinders the use of flow boiling in a microgravity environment. We will present results of experiments on transients in nucleate boiling that were carried out in the Flow Boiling Module (FBM) on the International Space Station (ISS). The unique ISS FBM ability is to couple large heat loads with flow visualization in testing flow boiling under strict control of experimental conditions in long-duration microgravity. Comparison of results of microgravity experiments with data obtained in a similar setup on the NASA GRC demonstrates the role of gravity in nucleate boiling. The work is supported by the NASA Flight Opportunities program (grant 80NSSC21K0501) and NSF/CASIS program (NSF CBET grants 1832260, 2126461, 2126462).

Two-phase flow and phase transition↗

Simulation studies of electron acceleration by ion ring distributions in solar flares

A 2.5-dimensional fully relativistic EM, particle-in-cell code (PIC) is used to investigate a potential electron acceleration mechanism in solar flares. The free energy is provided by ions which have a ring velocity distribution about the magnetic-field direction. Ion rings may be produced by perpendicular shocks, which could in turn be generated by the super-Alfvenic motion of magnetic flux tubes emerging from the photosphere or by coronal mass ejections. Such ion distributions are known to be unstable to the generation of lower hybrid waves, which have phase velocities in excess of the electron thermal speed parallel to the field and can, therefore, resonantly accelerate electrons in that direction. The simulations show the transfer of perpendicular ion energy to energetic electrons via lower hybrid wave turbulence. With plausible ion ring velocities, the process can account for the observationally inferred fluxes and energies of non-thermal electrons during the impulsive phase of flares.

Mcclements, K. G.↗

Preliminary Transfer Learning Results on Israel Data

In this preliminary report, we use publicly available data recorded in Israel to test and expand upon existing machine learning models for seismic-phase detection and arrival-time measurement. We downloaded 3-years of waveform data from Geofon, and cross referenced the waveforms to Israel bulletin picks (Schardong et al., 2021). The initial results using existing models directly generated ubiquitous false detections and that obscured detections of signals that are clearly visible in the waveforms. However, after applying transfer learning (tuning parameters in the existing ML models using one year of the Israel-network data), the results are encouraging, i.e. ML picks agree within a few tenths of a second with bulletin picks and the number of false detections is greatly reduced. The bulletin picks are a good starting point, but they cannot be considered ground-truth. To test potential improvement in picking using ML we would like to relocate the events using the ML picks to see if the events cluster more tightly at known mine locations. However, in order to constrain event locations, we need ML picks for the whole Israeli-Jordanian network, which requires waveforms that are not publicly available.

58 GEOSCIENCES↗

Flow boiling with enhancement devices for cold plate coolant channel design

The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.

Boyd, Ronald D., Sr.↗

NOvA Inclusive Nue CC Cross Section Data Release

NOvA inclusive electron neutrino cross section results presented at Neutrino2020Exposure:8.09E20 protons-on-target, neutrino-enhanced beamData release contains 3 ROOT files containing the double-differential measurement with respect to electron angle (cos theta) and electron energy, a single-differential measurement with respect to squared four-momentum transfer (Q2), and the total cross section as a function of neutrino energy. The 1D cross-section measurements include the same kinematic phase space restrictions present in the double-differential analysis.The files, xsec_{dThdE/Enu/dQ2}.root, contain the extracted cross section and associated covariance matrices for the double-differential cross section with respect to the observed electron kinematics, dThdE, neutrino energy, Enu, and squared four-momentum transfer, Q^2.In each file there will be the following histograms:— TH2D/TH1D xsec: unfolded measured cross section— TH2D xsec_cov: cross section covariance matrix— TH2D stat_cov: statistical covariance matrixIncludes text files, xsec_{dThdE/Enu/dQ2}.txt show the corresponding histograms in plain text format.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

One way time transfer via Meteosat capable of 30 (ns accuracy

The METEOSAT ranging signal's available every 3 hours for about 1.5 minutes, its phase is measured against the second pulses of the station clocks. A system study shows that the accuracy obtainable could be in the order of 30 ns. The receiver unit consists of a 2 m diameter fixed antenna, a low noise broadband receiver, and a phase tracker and demodulator. The overall costs will be less than $20.000 US.

Nottarp, K.↗

Determining Drying Conditions to Mitigate Hanford Double Shell Storage Tank Underside Corrosion — Phase 1

The Hanford Site in Washington State has legacy radiological waste that is being retrieved from single shell tanks (SSTs) and transferred to newer, double shell tanks (DSTs) for eventual closure of the SSTs. The waste is maintained in the DSTs until eventual immobilization can be performed at the Waste Treatment and Immobilization Plant (WTP), currently under construction. Until full immobilization is complete, extended service of the DSTs must be ensured by mitigating corrosion of the steel tank walls and buried steel pipelines. A Pit Air Supply System has been developed to mitigate corrosion of the leak detection pits connected to the concrete foundations of the DSTs. The objectives for the present study are: (i) to corrode steel specimens in an electrolytic simulant to form artificial pits with specific pit depths, and (ii) to determine the temperature and humidity levels that will mitigate further pit growth. Experimental work and results will be presented to evaluate conditions associated with the PASS system and predict corrosion rates when the PASS is operating.

Atmospheric Corrosion↗

Ignition delay of a gas mixture above a liquid fuel pool

A computational study has been made of transient heat transfer and fluid flow of an axisymmetric two-layer gas-and-liquid system heated from above by a small hot spot (e.g., a hot wire or pilot flame) located close to the liquid surface. The gas phase is unconfined above the liquid pool. The effects of varying gravity level (0.0001 to 1 gn), liquid pool height, and heater height are investigated. Thermocapillary convection induced by the nonuniform heating of the liquid surface combines with buoyancy forces to affect the heat transfer and the transport of fuel vapor toward the heat source. At reduced gravity, gas-phase conduction is comparable to the incident radiation at the liquid surface, whereas at 1 gn, buoyant convection carries the heat upward from the heat source and, therefore, the liquid is heated primarily by radiation.

Schiller, D. N.↗

Heat transfer in oscillating flows

The heat transfer in a sudden-expansion flow subjected to upstream periodic disturbances is investigated. In order to study the unsteady turbulent flow for the present symmetrical sudden-expansion flow, the phase-averaging technique of Hussain and Reynolds (1970) is used to derive the governing equations. The imposed periodic disturbances are found to increase the turbulent kinetic energy and the heat transfer rates at the wall. The phenomenon is discovered to be sensitive to the frequency of the imposed disturbances. At the optimum frequency and at a 3 percent disturbance level, the time-averaged heat transfer rate near the reattachment point can be increased by as much as 14 percent.

El-Mehlawy, F.↗

Mars: Correcting surface albedo observations for effects of atmospheric dust loading

We have developed a radiative transfer model which allows the effects of atmospheric dust loading on surface albedo to be investigated. This model incorporates atmospheric dust opacity, the single scattering albedo and particle phase function of atmospheric dust, the bidirectional reflectance of the surface, and variable lighting and viewing geometry. The most recent dust particle properties are utilized. The spatial and temporal variability of atmospheric opacity (Tan) strongly influences the radiative transfer modelling results. We are currently using the approach described to determine Tan for IRTM mapping sequences of selected regions. This approach allows Tan to be determined at the highest spatial and temporal resolution supported by the IRTM data. Applying the radiative transfer modelling and determination of Tan described, IRTM visual brightness observations can be corrected for the effects of atmospheric dust loading a variety of locations and times. This approach allows maps of 'dust-corrected surface albedo' to be constructed for selected regions. Information on the variability of surface albedo and the amount of dust deposition/erosion related to such variability results. To date, this study indicates that atmospheric dust loading has a significant effect on observations of surface albedo, amounting to albedo corrections of as much as several tens of percent. This correction is not constant or linear, but depends upon surface albedo, viewing and lighting geometry, the dust and surface phase functions, and the atmospheric opacity. It is clear that the quantitative study of surface albedo, especially where small variations in observed albedo are important (such as photometric analyses), needs to account for the effects of the atmospheric dust loading. Maps of 'dust-corrected surface albedo' will be presented for a number of regions.

Lee, S. W.↗

Interaction between Convection and Heat Transfer in Crystal Growth

Crystals are integral components in some of our most sophisticated and rapidly developing industries. Single crystals are solids with the most uniform structures that can be obtained on an atomic scale. Because of their structural uniformity, crystals can transmit acoustic and electromagnetic waves and charged particles with essentially no scattering or interferences. This transparency, which can be selectively modified by controlled additions of impurities known as dopants, is the foundation of modern electronic industry. It has brought about widespread application of crystals in transistors, lasers, microwave devices, infrared detectors, magnetic memory devices, and many other magnets and electro-optic components. The performance of a crystal depends strongly on its compositional homogeneity. For instance, in modern microcircuitry, compositional variations of a few percent (down to a submicron length scale) can seriously jeopardize predicted yields. Since crystals are grown by carefully controlled phase transformations, the compositional adjustment in the solid is often made during growth from the nutrient. Hence, a detailed understanding of mass transfer in the nutrient is essential. Moreover, since mass transfer is often the slowest process during growth, it is usually the rate limiting mechanism. Crystal growth processes are usually classified according to the nature of the parent phase. Nevertheless, whether the growth occurs by solidification from a melt (melt growth), nucleation from a solution (solution growth), condensation from a vapor (physical vapor transport) or chemical reaction of gases (chemical vapor deposition), the parent phase is a fluid. As is with most non-equilibrium processes involving fluids, liquid or vapor, fluid motion plays an important role, affecting both the concentration and temperature gradients at the soli-liquid interface.

Source record↗

Multi-modular capacitive wireless power transfer circuit and related techniques

A high performance kilowatt-scale large air-gap multi-modular capacitive wireless power transfer (WPT) system is provided for electric vehicle (EV) charging. In one particular implementation, the multi-modular system achieves high power transfer while maintaining fringing electric fields within prescribed safety limits. The fringing fields are reduced using near-field phased-array field-focusing techniques, wherein the adjacent modules of the multi-modular system are out-phased with respect to one another. The inter-module interactions in this multi-modular system can be modeled, and an approach to eliminate these interactions in a practical EV charging environment is provided. To illustrate one example implementation, a prototype 1.2-kW 6.78-MHz 12-cm air-gap multi-modular capacitive WPT system comprising two 600-W modules is provided. This prototype system achieves 21.2 kW/m2 power transfer density and a peak efficiency of 89.8%. This multi-modular system also achieves a fringing field reduction of 50% compared to its individual modules.

Afridi, Khurram K.↗

Semi-empirical quantum optics for mid-infrared molecular nanophotonics

Nanoscale infrared (IR) resonators with sub-diffraction limited mode volumes and open geometries have emerged as new platforms for implementing cavity quantum electrodynamics at room temperature. The use of IR nanoantennas and tip nanoprobes to study strong light–matter coupling of molecular vibrations with the vacuum field can be exploited for IR quantum control with nanometer spatial and femtosecond temporal resolution. In order to advance the development of molecule-based quantum nanophotonics in the mid-IR, we propose a generally applicable semi-empirical methodology based on quantum optics to describe light–matter interaction in systems driven by mid-IR femtosecond laser pulses. The theory is shown to reproduce recent experiments on the acceleration of the vibrational relaxation rate in infrared nanostructures. It also provides physical insights on the implementation of coherent phase rotations of the near-field using broadband nanotips. We then apply the quantum framework to develop general tip-design rules for the experimental manipulation of vibrational strong coupling and Fano interference effects in open infrared resonators. We finally propose the possibility of transferring the natural anharmonicity of molecular vibrational levels to the resonator near-field in the weak coupling regime to implement intensity-dependent phase shifts of the coupled system response with strong pulses and develop a vibrational chirping model to understand the effect. The semi-empirical quantum theory is equivalent to first-principles techniques based on Maxwell’s equations, but its lower computational cost suggests its use as a rapid design tool for the development of strongly coupled infrared nanophotonic hardware for applications ranging from quantum control of materials to quantum information processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topical: Boiling, Condensation and Two-Phase Flows in Microgravity

The white paper addresses both fundamental and technological questions in the science of phase-change fluid flows aimed at understanding thermal transport in flow boiling and condensation and the use of these processes in space and terrestrial thermal systems. While flow boiling and condensation are widely employed in Earth-based thermal equipment to reduce the cost, size, and power required to transfer heat, a lack of data and predictive models on the impact of gravity on these phenomena hinders the use of two-phase heat transport in a low-gravity environment. The white paper presents research tasks in long-duration microgravity recommended to expand our knowledge on phase-changing flows. Due to elimination of the masking gravity effects, the proposed research will provide a unique opportunity to bring new insights into the role of capillary and hydrodynamic forces in phase-changing flows. The potential impact of the proposed research ranges from the space power, thermal and cryogenic systems to various terrestrial applications in the petrochemical, pharmaceutical, biochemical, nuclear, and metallurgical industries.

Phase-change fluid flow↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗