Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Development of an improved mirror facet for space applications

A fabrication technique was successfully developed for a metallic aluminum honeycomb, high-accuracy, lightweight, and long-life solar concentrator (mirror) for Advanced Solar Dynamic Space Power Systems. The program scope was limited to the development, fabrication, evaluation, and delivery of a solar concentrator facet (petal) that was sized for a 2-meter deployable solar concentrator. A surface accuracy of 1.0 mrad was achieved. The development incorporated tooling design, material selection, facet forming, adhesive selection, testing, and analysis. Techniques for applying levelizing, reflective, and protective optical coatings were also developed.

Schertz, Paul↗

Mirror mode waves at Comet Halley

High resolution VEGA magnetic field and plasma data in Halley's magnetosphere reveal out-of-phase oscillations of the type expected to be driven by the mirror mode instability. The spacecraft passes through these structures in about 20 s. The magnetic energy density drops about 6.5 x 15 exp 9 ergs/cu cm in a typical event. The thickness of these regions is about a water-group ion gyro diameter. While such enhancements should be invisible against the comet when viewed perpendicular to the wavefronts, they could be visible as rays when viewed tangential to the wavefronts.

Russell, C. T.↗

Self-checking self-repairing computer nodes using the mirror processor

Circuitry added to fault-tolerant systems for concurrent error deduction usually reduces performance. Using a technique called micro rollback, it is possible to eliminate most of the performance penalty of concurrent error detection. Error detection is performed in parallel with intermodule communication, and erroneous state changes are later undone. The author reports on the design and implementation of a VLSI RISC microprocessor, called the Mirror Processor (MP), which is capable of micro rollback. In order to achieve concurrent error detection, two MP chips operate in lockstep, comparing external signals and a signature of internal signals every clock cycle. If a mismatch is detected, both processors roll back to the beginning of the cycle when the error occurred. In some cases the erroneous state is corrected by copying a value from the fault-free processor to the faulty processor. The architecture, microarchitecture, and VLSI implementation of the MP, emphasizing its error-detection, error-recovery, and self-diagnosis capabilities, are described.

Tamir, Yuval↗

The mirror and ion cyclotron anisotropy instabilities

The linear dispersion equation for fully electromagnetic waves and instabilities at arbitrary directions of propagation relative to a background magnetic field B(0) in a homogeneous Vlasov plasma is solved numerically for bi-Maxwellian particle distributions. For isotropic plasmas the dispersion and damping of the three modes below the proton cyclotron frequency are studied as functions of Beta(i) and T(e)/T(i). The transport ratios of helicity, cross-helicity, Alfven ratio, compressibility, and parallel compressibility are defined. Under the condition that the proton temperature perpendicular to B(0) is greater than the parallel temperature, the growth rates and transport ratios of the mirror instability and the ion cyclotron anisotropy instability are examined and compared. Both the proton parallel compressibility and the proton Alfven ratio are significantly different for the two growing modes.

Gary, S. P.↗

Nonlinear magnetosonic waves and mirror mode structures in the March 1991 Ulysses interplanetary event

In examining the March 23-25, 1991 Ulysses (2.2 AU) high speed solar wind events, two distinct plasma wave modes are found: steepened magnetosonic waves with whistler precursors and mirror mode structures. These two modes are locally generated by plasma instabilities, presumably associated with anisotropies existing in the energetic shock particles and solar wind plasma, respectively. The magnetosonic waves are generated by a right-hand resonant instability associated with an about 40 keV ion beam. By an extrapolation of the results presented here, assuming microflares and nanoflares at the sun generate shocks in the lower corona and these shocks accelerate energetic ions, it is suggested that the ions, via the right-hand resonant instability, generate magnetosonic waves which steepened to form 'microshocks'. These shocks could, in turn, accelerate more energetic ions, leading to a shock/energetic ion/magnetosonic wave cascade. These newly formed magnetosonic waves and shocks presumably could propagate in a broad range of directions, leading to energy dissipation over a large region of the outer corona.

Tsurutani, Bruce T.↗

Electroform replication of smooth mirrors from sapphire masters

A sapphire master was used to produce mirrors that exhibit mid-to-high-frequency roughness as low as 3 A. The fabrication procedure and potential applications in X-ray astronomy are discussed. It is shown that foils replicated from flat smooth mandrels should offer at least equivalent HF roughness and significantly lower mid-frequency ripple than those coated with lacquer. A ceramic-surface mandrel could also be expected to last far longer without the need for repolishing than electroless nickel-coated mandrels.

Altkorn, R.↗

Intensity distribution of the x ray source for the AXAF VETA-I mirror test

The X-ray generator for the AXAF VETA-I mirror test is an electron impact X-ray source with various anode materials. The source sizes of different anodes and their intensity distributions were measured with a pinhole camera before the VETA-I test. The pinhole camera consists of a 30 micrometers diameter pinhole for imaging the source and a Microchannel Plate Imaging Detector with 25 micrometers FWHM spatial resolution for detecting and recording the image. The camera has a magnification factor of 8.79, which enables measuring the detailed spatial structure of the source. The spot size, the intensity distribution, and the flux level of each source were measured with different operating parameters. During the VETA-I test, microscope pictures were taken for each used anode immediately after it was brought out of the source chamber. The source sizes and the intensity distribution structures are clearly shown in the pictures. They are compared and agree with the results from the pinhole camera measurements. This paper presents the results of the above measurements. The results show that under operating conditions characteristic of the VETA-I test, all the source sizes have a FWHM of less than 0.45 mm. For a source of this size at 528 meters away, the angular size to VETA is less than 0.17 arcsec which is small compared to the on ground VETA angular resolution (0.5 arcsec, required and 0.22 arcsec, measured). Even so, the results show the intensity distributions of the sources have complicated structures. These results were crucial for the VETA data analysis and for obtaining the on ground and predicted in orbit VETA Point Response Function.

Zhao, Ping↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

Precision of the calibration of the AXAF engineering test article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗

A wavefront compensation approach to segmented mirror figure control

We consider the 'figure-control' problem for a spaceborn sub-millimeter wave telescope, the Precision Segmented Reflector Project Focus Mission Telescope. We show that performance of any figure control system is subject to limits on the controllability and observability of the quality of the wavefront. We present a wavefront-compensation method for the Focus Mission Telescope which uses mirror-figure sensors and three-axis segment actuator to directly minimize wavefront errors due to segment position errors. This approach shows significantly better performance when compared with a panel-state-compensation approach.

Redding, David↗

Segmented mirror figure control for a space-based far-IR astronomical telescope

For segmented large mirrors to be used effectively for astronomy they must be actively aligned and controlled to extreme levels of precision. We consider the figure control problem for a spaceborne far-IR telescope, the Precision Segmented Reflector Project Focus Moderate Mission Telescope. We propose a two-stage approach. A figure initialization controller is used to achieve initial phasing and alignment of the telescope using an imaging science detector. A figure maintenance controller keeps the telescope aligned during normal operation using a laser metrology optical truss sensor system. We show that performance of any figure control system is subject to limits on the controllability of the wavefront. Maintenance controllers are additionally limited by considerations of the observability of the wavefront from the maintenance sensors. We show preliminary results for the figure initialization controller. We present a 'Wavefront Compensation' method for figure maintenance control that minimizes wavefront errors due to misalignment errors.

Redding, David↗

Spectral radiation analyses of the GOES solar illuminated hexagonal cell scan mirror back

A ray tracing analytical tool has been developed for the simulation of spectral radiation exchange in complex systems. Algorithms are used to account for heat source spectral energy, surface directional radiation properties, and surface spectral absorptivity properties. This tool has been used to calculate the effective solar absorptivity of the geostationary operational environmental satellites (GOES) scan mirror in the calibration position. The development and design of Sounder and Imager instruments on board GOES is reviewed and the problem of calculating the effective solar absorptivity associated with the GOES hexagonal cell configuration is presented. The analytical methodology based on the Monte Carlo ray tracing technique is described and results are presented and verified by experimental measurements for selected solar incidence angles.

Fantano, Louis G.↗

Cryogenic performance of the SIRTF prototype secondary mirror assembly

Results are presented of the first liquid helium temperature testing of the Space Infrared Telescope Facility (SIRTF) prototype Secondary Mirror Assembly (PSMA). Attention is given to the key requirements of PSMA, its design, and the test instrumentation and procedures. Results of preliminary tests completed to date showed that the design of the PSMA forms a very strong basis for meeting the SIRTF requirements.

Stier, M. T.↗

Dimensionally stable, graphite-fiber reinforced composite mirror technology

A research project intended to design and fabricate a dimensionally stable 2 mu spherical mirror 0.4 m in diameter, carried out by Composite Optics, Incorporated, is briefly reported. A laminate for the facesheet and the back surface that is intended to be exceptionally uniform in-plane has been designed using the P75/ERL 1999 material. The core is designed to be pseudoisotropic in all three directions.

Kulick, Shel↗

Thermal and structural analysis of the GOES scan mirror's on orbit performance

The on-orbit performance of the GOES satellite's scan mirror has been predicted by means of thermal, structural, and optical models. A simpler-than-conventional thermal model was used to reduce the time required to obtain orbital predictions, and the structural model was used to predict on-earth gravity sag and on-orbit distortions. The transfer of data from the thermal model to the structural model was automated for a given set of thermal nodes and structural grids.

Zurmehly, G. E.↗

Intensity distribution of the X-ray source for the AXAF VETA-I mirror test

Intensity distribution measurements of the X-ray source for the AXAF VETA-I mirror test are reported. During the VETA-I test, microscope pictures were taken for each used anode immediately after it was brought out of the source chamber. The source sizes and the intensity distribution structures are shown. They are compared and shown to agree with the results from pinhole camera measurements. It is demonstrated that under operating conditions characteristic of the VETA-I test, all the source sizes have an FWHM of less than 0.45 mm. For a source of this size at 528 m away, the angular size to VETA is less than 0.17 arcsec, which is small compared to the on-ground VETA angular resolution. These results were crucial for VETA data analysis and for obtaining the on-ground and predicted in-orbit VETA point response function.

Zhao, Ping↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/- 9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

Precision of the calibration of the AXAF Engineering Test Article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗