Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Self-consistent implementation of locally scaled self-interaction-correction method

Recently proposed local self-interaction correction (LSIC) method is a one-electron self-interaction-correction (SIC) method that uses an iso-orbital indicator to apply the SIC at each point in space by scaling the exchange–correlation and Coulomb energy densities. The LSIC method is exact for the one-electron densities, also recovers the uniform electron gas limit of the uncorrected density functional approximation, and reduces to the well-known Perdew–Zunger SIC (PZSIC) method as a special case. This article presents the self-consistent implementation of the LSIC method using the ratio of Weizsäcker and Kohn–Sham kinetic energy densities as an iso-orbital indicator. The atomic forces as well as the forces on the Fermi-Löwdin orbitals are also implemented for the LSIC energy functional. Results show that LSIC with the simplest local spin density functional predicts atomization energies of the AE6 dataset better than some of the most widely used generalized-gradient-approximation (GGA) functional and barrier heights of the BH6 database better than some of the most widely used hybrid functionals. The LSIC method [a mean absolute error (MAE) of 0.008 Å] predicts bond lengths of a small set of molecules better than the PZSIC-LSDA (MAE 0.042 Å) and LSDA (0.011 Å). Furthermore, this work shows that accurate results can be obtained from the simplest density functional by removing the self-interaction-errors using an appropriately designed SIC method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods for Bayesian power spectrum inference with galaxy surveys

We derive and implement a full Bayesian large scale structure inference method aiming at precision recovery of the cosmological power spectrum from galaxy redshift surveys. Our approach improves upon previous Bayesian methods by performing a joint inference of the three-dimensional density field, the cosmological power spectrum, luminosity dependent galaxy biases, and corresponding normalizations. We account for all joint and correlated uncertainties between all inferred quantities. Classes of galaxies with different biases are treated as separate subsamples. This method therefore also allows the combined analysis of more than one galaxy survey. In particular, it solves the problem of inferring the power spectrum from galaxy surveys with non-trivial survey geometries by exploring the joint posterior distribution with efficient implementations of multiple block Markov chain and Hybrid Monte Carlo methods. Our Markov sampler achieves high statistical efficiency in low signal-to-noise regimes by using a deterministic reversible jump algorithm. This approach reduces the correlation length of the sampler by several orders of magnitude, turning the otherwise numerically unfeasible problem of joint parameter exploration into a numerically manageable task. We test our method on an artificial mock galaxy survey, emulating characteristic features of the Sloan Digital Sky Survey data release 7, such as its survey geometry and luminosity-dependent biases. These tests demonstrate the numerical feasibility of our large scale Bayesian inference frame work when the parameter space has millions of dimensions. This method reveals and correctly treats the anti-correlation between bias amplitudes and power spectrum, which are not taken into account in current approaches to power spectrum estimation, a 20% effect across large ranges in k space. In addition, this method results in constrained realizations of density fields obtained without assuming the power spectrum or bias parameters in advance.

79 ASTRONOMY AND ASTROPHYSICS↗

Conservative self-force correction to the innermost stable circular orbit: Comparison with multiple post-Newtonian-based methods

Barack and Sago [Phys. Rev. Lett. 102, 191101 (2009)] have recently computed the shift of the innermost stable circular orbit (ISCO) of the Schwarzschild spacetime due to the conservative self-force that arises from the finite-mass of an orbiting test-particle. This calculation of the ISCO shift is one of the first concrete results of the self-force program, and provides an exact (fully relativistic) point of comparison with approximate post-Newtonian (PN) computations of the ISCO. Here this exact ISCO shift is compared with nearly all known PN-based methods. These include both 'nonresummed' and 'resummed' approaches (the latter reproduce the test-particle limit by construction). The best agreement with the exact (Barack-Sago) result is found when the pseudo-4PN coefficient of the effective-one-body (EOB) metric is fit to numerical relativity simulations. However, if one considers uncalibrated methods based only on the currently known 3PN-order conservative dynamics, the best agreement is found from the gauge-invariant ISCO condition of Blanchet and Iyer [Classical Quantum Gravity 20, 755 (2003)], which relies only on the (nonresummed) 3PN equations of motion. This method reproduces the exact test-particle limit without any resummation. A comparison of PN methods with the ISCO in the equal-mass case (computed via sequences of numerical relativity initial-data sets) is also performed. Here a (different) nonresummed method also performs very well (as was previously shown). These results suggest that the EOB approach - while exactly incorporating the conservative test-particle dynamics and having several other important advantages - does not (in the absence of calibration) incorporate conservative self-force effects more accurately than standard PN methods. I also consider how the conservative self-force ISCO shift, combined in some cases with numerical relativity computations of the ISCO, can be used to constrain our knowledge of (1) the EOB effective metric, (2) phenomenological inspiral-merger-ringdown templates, and (3) 4PN- and 5PN-order terms in the PN orbital energy. These constraints could help in constructing better gravitational-wave templates. Lastly, I suggest a new method to calibrate unknown PN terms in inspiral templates using numerical-relativity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stochastic and deterministic methods for the calculation of small-sample reactivity experiments

Several calculations methods for the analysis of small-sample reactivity experiments are presented, as their main advantages and drawbacks. A numerical benchmark has been defined for this study consisting in a regular lattice of UO{sub 2} fuel pins, in which the central one is successively poisoned with isotopes of interest (actinides, absorbers, ...). A first method, based on a forward calculation ('eigenvalues difference method'), is presented, using either a deterministic or a stochastic calculation code. A first perturbative method studied is based on the 'Exact Perturbation Theory' (EPT) implemented in the deterministic code APOLLO2.8, and gives consistent results against forward calculations. A second perturbative method, the 'correlated sampling method', implemented in the stochastic calculation code TRIPOLI4.7 is tested. It should be use carefully as it is generally validated against small atomic density changes, but can be useful for conception studies. An 'hybrid method', based on the EPT formalism, using both Monte Carlo and deterministic results is tested, and shows reliable results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examination of Semi-Analytical Solution Methods in the Coarse Operator of Parareal Algorithm for Power System Simulation

With continuing advances in high-performance parallel computing platforms, parallel algorithms have become powerful tools for development of faster than real-time power system dynamic simulations. In particular, it has been demonstrated in recent years that parallel-in-time (Parareal) algorithms have the potential to achieve such an ambitious goal. Here, the selection of a fast and reasonably accurate coarse operator of the Parareal algorithm is crucial for its effective utilization and performance. This paper examines semi-analytical solution (SAS) methods as the coarse operators of the Parareal algorithm and explores performance of the SAS methods to the standard numerical time integration methods. Two promising time-power series-based SAS methods were considered; Adomian decomposition method and Homotopy analysis method with a windowing approach for improving the convergence. Numerical performance case studies on 10-generator 39-bus system and 327-generator 2383-bus system were performed for these coarse operators over different disturbances, evaluating the number of Parareal iterations, computational time, and stability of convergence. All the coarse operators tested with different scenarios have converged to the same corresponding true solution (if they are convergent) and the SAS methods provide comparable computational speed, while having more stable convergence to the true solution in many cases.

97 MATHEMATICS AND COMPUTING↗

A method to improve accuracy and precision of water surface identification for photon depth dose measurements

The objective of this study is to present a method to reduce the setup error inherent in clinical depth dose measurements and, in doing so, to improve entrance dosimetry measurement reliability. Ionization chamber (IC) depth dose measurements are acquired with the depth scan extended into the air above the water surface. An inflection region is obtained in each resulting percent depth ionization (PDI) curve that can be matched against other measurements or to an inflection region obtained from an analogous Monte Carlo (MC) simulation. Measurements are made with various field sizes for the 6 and 18 MV photon beams, with and without a Pb foil in the beam, to determine the sensitivity of the dose inflection region to the beam conditions. The offset between reference and test data set inflection regions is quantified using two separate methods. When comparing sets of measured data, maxima in the second derivative of ionization are compared. When comparing measured data to MC simulation, the offset that minimizes the sum of squared differences between the reference and test curves in the ionization inflection region is found. These methods can be used to quantify the offset between an initial setup (test) position and the true surface (reference) position. The ionization inflection location is found to be insensitive to changes in field size, electron contamination, and beam energy. Data from a single reference condition should be sufficient to identify the surface location. The method of determining IC offsets is general and should be applicable to any IC and other radiation sources. The measurement method could reduce the time and effort required in the initial IC setup at a water surface as setup errors can be corrected offline. Given a reliable set of reference data to compare with, this method could increase the ability of quality assurance (QA) measurements to detect discrepancies in beam output as opposed to discrepancies in IC localization. Application of the measurement method standardizes the procedure for localizing cylindrical ICs at a water surface and thereby improves the reliability of measurements taken with these devices at all depths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations

Purpose: The purposes of this work were: (1) To determine if a spectral method can accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for situations where the Cerenkov light is dominant over the scintillation light and (2) to develop a procedural guideline for accurately determining the calibration factors of PSDs. Methods: The authors demonstrate, by using the equations of the spectral method, that the condition for accurately correcting the effect of Cerenkov light is that the ratio of the two calibration factors must be equal to the ratio of the Cerenkov light measured within the two different spectral regions used for analysis. Based on this proof, the authors propose two new procedures to determine the calibration factors of PSDs, which were designed to respect this condition. A PSD that consists of a cylindrical polystyrene scintillating fiber (1.6 mm{sup 3}) coupled to a plastic optical fiber was calibrated by using these new procedures and the two reference procedures described in the literature. To validate the extracted calibration factors, relative dose profiles and output factors for a 6 MV photon beam from a medical linac were measured with the PSD and an ionization chamber. Emphasis was placed on situations where the Cerenkov light is dominant over the scintillation light and on situations dissimilar to the calibration conditions. Results: The authors found that the accuracy of the spectral method depends on the procedure used to determine the calibration factors of the PSD and on the attenuation properties of the optical fiber used. The results from the relative dose profile measurements showed that the spectral method can correct the Cerenkov light effect with an accuracy level of 1%. The results obtained also indicate that PSDs measure output factors that are lower than those measured with ionization chambers for square field sizes larger than 25x25 cm{sup 2}, in general agreement with previously published Monte Carlo results. Conclusions: The authors conclude that the spectral method can be used to accurately correct the Cerenkov light effect in PSDs. The authors confirmed the importance of maximizing the difference of Cerenkov light production between calibration measurements. The authors also found that the attenuation of the optical fiber, which is assumed to be constant in the original formulation of the spectral method, may cause a variation of the calibration factors in some experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations

Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version of commercial treatment planning system for a patient case. Methods: The average dose accumulated in a finite volume should be unchanged when the dose delivered to one anatomic instance of that volume is mapped to a different anatomic instance--provided that the tissue deformation between the anatomic instances is mass conserving. The average dose to a finite volume on image S is defined as d{sub S}=e{sub s}/m{sub S}, where e{sub S} is the energy deposited in the mass m{sub S} contained in the volume. Since mass and energy should be conserved, when d{sub S} is mapped to an image R(d{sub S{yields}R}=d{sub R}), the mean dose mapping error is defined as {Delta}d{sub m}=|d{sub R}-d{sub S}|=|e{sub R}/m{sub R}-e{sub S}/m{sub S}|, where the e{sub R} and e{sub S} are integral doses (energy deposited), and m{sub R} and m{sub S} are the masses within the region of interest (ROI) on image R and the corresponding ROI on image S, where R and S are the two anatomic instances from the same patient. Alternatively, application of simple differential propagation yields the differential dose mapping error, {Delta}d{sub d}=|({partial_derivative}d/{partial_derivative}e)*{Delta}e+({partial_derivative}d/{partial_derivative}m)*{Delta}m|=|((e{sub S}-e{sub R})/m{sub R})-((m{sub S}-m{sub R})/m{sub R}{sup 2})*e{sub R}|={alpha}|d{sub R}-d{sub S}| with {alpha}=m{sub S}/m{sub R}. A 4D treatment plan on a ten-phase 4D-CT lung patient is used to demonstrate the dose mapping error evaluations for a patient case, in which the accumulated dose, D{sub R}={Sigma}{sub S=0}{sup 9}d{sub S{yields}R}, and associated error values ({Delta}D{sub m} and {Delta}D{sub d}) are calculated for a uniformly spaced set of ROIs. Results: For the single sample patient dose distribution, the average accumulated differential dose mapping error is 4.3%, the average absolute differential dose mapping error is 10.8%, and the average accumulated mean dose mapping error is 5.0%. Accumulated differential dose mapping errors within the gross tumor volume (GTV) and planning target volume (PTV) are lower, 0.73% and 2.33%, respectively. Conclusions: A method has been presented to evaluate the dose mapping error introduced by the dose mapping process. This method has been applied to evaluate the 4D dose calculation process implemented in a commercial treatment planning system. The method could potentially be developed as a fully-automatic QA method in image guided adaptive radiation therapy (IGART).

61 RADIATION PROTECTION AND DOSIMETRY↗

Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method

Purpose: Four-dimensional cone beam computed tomography (4D-CBCT) has been developed to provide respiratory phase-resolved volumetric imaging in image guided radiation therapy. Conventionally, it is reconstructed by first sorting the x-ray projections into multiple respiratory phase bins according to a breathing signal extracted either from the projection images or some external surrogates, and then reconstructing a 3D CBCT image in each phase bin independently using FDK algorithm. This method requires adequate number of projections for each phase, which can be achieved using a low gantry rotation or multiple gantry rotations. Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. 4D-CBCT images at different breathing phases share a lot of redundant information, because they represent the same anatomy captured at slightly different temporal points. Taking this redundancy along the temporal dimension into account can in principle facilitate the reconstruction in the situation of inadequate number of projection images. In this work, the authors propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. Methods: The authors define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms implementation on GPU is designed to avoid redundant and uncoalesced memory access, in order to ensure a high computational efficiency. Our algorithms have been tested on a digital NURBS-based cardiac-torso phantom and a clinical patient case. Results: The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56-3.13 and our enhancement method increases the CNR by 2.75-3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is 509-683 s for the reconstruction algorithm and 524-540 s for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card. Conclusions: By innovatively taking the temporal redundancy among 4D-CBCT images into consideration, the proposed algorithms can produce high quality 4D-CBCT images with much less streak artifacts than the FDK results, in the situation of inadequate number of projections.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-02: High-Pitch and Sparse-View Helical 4D CT Via Iterative Image Reconstruction Method Based On Tensor Framelet

Purpose: 4D CT is routinely performed during radiation therapy treatment planning of thoracic and abdominal cancers. Compared with the cine mode, the helical mode is advantageous in temporal resolution. However, a low pitch (∼0.1) for 4D CT imaging is often required instead of the standard pitch (∼1) for static imaging, since standard image reconstruction based on analytic method requires the low-pitch scanning in order to satisfy the data sufficient condition when reconstructing each temporal frame individually. In comparison, the flexible iterative method enables the reconstruction of all temporal frames simultaneously, so that the image similarity among frames can be utilized to possibly perform high-pitch and sparse-view helical 4D CT imaging. The purpose of this work is to investigate such an exciting possibility for faster imaging with lower dose. Methods: A key for highpitch and sparse-view helical 4D CT imaging is the simultaneous reconstruction of all temporal frames using the prior that temporal frames are continuous along the temporal direction. In this work, such a prior is regularized through the sparsity transform based on spatiotemporal tensor framelet (TF) as a multilevel and high-order extension of total variation transform. Moreover, GPU-based fast parallel computing of X-ray transform and its adjoint together with split Bregman method is utilized for solving the 4D image reconstruction problem efficiently and accurately. Results: The simulation studies based on 4D NCAT phantoms were performed with various pitches (i.e., 0.1, 0.2, 0.5, and 1) and sparse views (i.e., 400 views per rotation instead of standard >2000 views per rotation), using 3D iterative individual reconstruction method based on 3D TF and 4D iterative simultaneous reconstruction method based on 4D TF respectively. Conclusion: The proposed TF-based simultaneous 4D image reconstruction method enables high-pitch and sparse-view helical 4D CT with lower dose and faster speed.

60 APPLIED LIFE SCIENCES↗

SU-E-J-58: Comparison of Conformal Tracking Methods Using Initial, Adaptive and Preceding Image Frames for Image Registration

Purpose: Accounting for tumor motion during radiation therapy is important to ensure that the tumor receives the prescribed dose. Increasing the field size to account for this motion exposes the surrounding healthy tissues to unnecessary radiation. In contrast to using motion-encompassing techniques to treat moving tumors, conformal radiation therapy (RT) uses a smaller field to track the tumor and adapts the beam aperture according to the motion detected. This work investigates and compares the performance of three markerless, EPID based, optical flow methods to track tumor motion with conformal RT. Methods: Three techniques were used to track the motions of a 3D printed lung tumor programmed to move according to the tumor of seven lung cancer patients. These techniques utilized a multi-resolution optical flow algorithm as the core computation for image registration. The first method (DIR) registers the incoming images with an initial reference frame, while the second method (RFSF) uses an adaptive reference frame and the third method (CU) uses preceding image frames for registration. The patient traces and errors were evaluated for the seven patients. Results: The average position errors for all patient traces were 0.12 ± 0.33 mm, −0.05 ± 0.04 mm and −0.28 ± 0.44 mm for CU, DIR and RFSF method respectively. The position errors distributed within 1 standard deviation are 0.74 mm, 0.37 mm and 0.96 mm respectively. The CU and RFSF algorithms are sensitive to the characteristics of the patient trace and produce a wider distribution of errors amongst patients. Although the mean error for the DIR method is negatively biased (−0.05 mm) for all patients, it has the narrowest distribution of position error, which can be corrected using an offset calibration. Conclusion: Three techniques of image registration and position update were studied. Using direct comparison with an initial frame yields the best performance. The authors would like to thank Dr.YeLin Suh for making the Cyberknife dataset available to us. Scholarship funding from the Natural Sciences and Engineering Research Council of Canada (NSERC) and CancerCare Manitoba Foundation is acknowledged.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-05: New Dosimetry Methods for CBCT

Purpose: To determine the absorbed dose to water in the moderately filtered (M-series) x-ray beams at the UWADCL and assess the feasibility of transferring this dose to water to a clinical CBCT environment. Methods: The dose was determined in the M-series beams using three dosimetry Methods: the TG-61 protocol, a {sup 60}Co absorbed dose to water calibration, and through the use of a Monte Carlo (MC) model of the x-ray tube. The dose to water in the M-series beams determined by the MC model was used to calibrate an ionization chamber. The calibrated chamber was used to measure the dose to water from a Varian CBCT system. The dose from the CBCT beams was also measured using the same methods as for the M-series beams. Results: The measured surface doses in the M-series beams determined by MC method and TG-61 agreed within 3% for all beams. The dose to water a depth of 2 cm in the M-series beams as determined by the TG-61, {sup 60}Co, and MC methods, agreed within 2%. The dose in the CBCT beams was determined using the same methods as for the M-series beams and using the newly determined x-ray dose to water calibration coefficient. At the phantom surface, the dose values agreed within 1.5% and at a 2 cm depth the values agreed within 3%. Conclusion: New techniques to determine the absorbed dose to water in standard x-ray beams were developed. The dose values were in good agreement with previous techniques, but with much lower uncertainties. The dose to water in the M-series beams was used to calibrate an ionization chamber and the dose in the CBCT beams was measured using this calibration. The CBCT dose at a depth of 2 cm was measured in this manner and it agreed with other dose determination methods.

60 APPLIED LIFE SCIENCES↗

Nonlocal and Mixed-Locality Multiscale Finite Element Methods

In many applications the resolution of small-scale heterogeneities remains a significant hurdle to robust and reliable predictive simulations. In particular, while material variability at the mesoscale plays a fundamental role in processes such as material failure, the resolution required to capture mechanisms at this scale is often computationally intractable. Multiscale methods aim to overcome this difficulty through judicious choice of a subscale problem and a robust manner of passing information between scales. One promising approach is the multiscale finite element method, which increases the fidelity of macroscale simulations by solving lower-scale problems that produce enriched multiscale basis functions. Here, in this study, we present the first work toward application of the multiscale finite element method to the nonlocal peridynamic theory of solid mechanics. This is achieved within the context of a discontinuous Galerkin framework that facilitates the description of material discontinuities and does not assume the existence of spatial derivatives. Analysis of the resulting nonlocal multiscale finite element method is achieved using the ambulant Galerkin method, developed here with sufficient generality to allow for application to multiscale finite element methods for both local and nonlocal models that satisfy minimal assumptions. Finally, we conclude with preliminary results on a mixed-locality multiscale finite element method in which a nonlocal model is applied at the fine scale and a local model at the coarse scale.

97 MATHEMATICS AND COMPUTING↗

Numerical Methods of Computational Electromagnetics for Complex Inhomogeneous Systems

Understanding electromagnetic phenomena is the key in many scientific investigation and engineering designs such as solar cell designs, studying biological ion channels for diseases, and creating clean fusion energies, among other things. The objectives of the project are to develop high order numerical methods to simulate evanescent electromagnetic waves occurring in plasmon solar cells and biological ion-channels, where local field enhancement within random media in the former and long range electrostatic interactions in the latter are of major challenges for accurate and efficient numerical computations. We have accomplished these objectives by developing high order numerical methods for solving Maxwell equations such as high order finite element basis for discontinuous Galerkin methods, well-conditioned Nedelec edge element method, divergence free finite element basis for MHD, and fast integral equation methods for layered media. These methods can be used to model the complex local field enhancement in plasmon solar cells. On the other hand, to treat long range electrostatic interaction in ion channels, we have developed image charge based method for a hybrid model in combining atomistic electrostatics and continuum Poisson-Boltzmann electrostatics. Such a hybrid model will speed up the molecular dynamics simulation of transport in biological ion-channels.

97 MATHEMATICS AND COMPUTING↗

Application of Electrochemical Methods to Molten Salt Reactors: Draft TLR Documenting Assessment of Electrochemical Monitoring

Nuclear Regulatory Commission (NRC) is developing the regulatory framework and technical expertise to support regulatory review of advanced non-water reactors, including molten salt reactors (MSRs). In an MSR, it is essential that the salt chemistry be maintained in a desired range in terms of redox potential for reliable operation and mitigation of corrosion to structural materials in the reactor, particularly the reactor vessel and heater exchanger. Measuring the redox potential of the salt in the reactor would also allow for the material lifetimes to be predicted more accurately, and chemical issues to be diagnosed more quickly. In addition to the chemical composition analysis by ICP-MS, electrochemical methods including potentiometry and linear wave scanning (LSC) were also used in molten salt reactor experiment (MSRE) for redox potential monitoring purposes. Electrochemcial methods offers unique advantages such as quick turnaround in results and unique capability of in-line monitoring of redox potential, and are considered popular electroanalytical techniques that can be used to monitor redox potentials and salt chemistry including impurities. The last two decades have seen significant advances in science and engineering of electrochemical methods for potential application to molten salts. The primary goal of this report is to assist NRC in understanding the monitoring of the salt chemistry by electrochemical methods and provide NRC reviewers with necessary information and tools to support regulatory review of MSR designs. This reports consists of two majors parts—Part 1, chemical potential of molten salts and effects by fission process in MSR; Part 2, assessment of electrochemical methods for application to MSRs. The TRLs of the typical relevant electrochemical methods for molten salts were evaluated based on the DOE TRL guidelines and upon a review of the current status of the electrochemical methods for two typical salt systems, fluoride and chloride, for MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Different methods of estimating riverbed sediment grain size diverge at the basin scale

Introduction: The distribution of sediment grain size in streams and rivers is often quantified by the median grain size (D50), a key metric for understanding and predicting hydrologic and biogeochemical function of streams and rivers. Manual D50 measurements are time-consuming and ignore larger grains, while approaches to model D50 based on catchment characteristics may over-generalize and miss site-scale heterogeneity. Machine learning-enabled object detection methods like You Only Look Once (YOLO) provides an alternative that enables estimation of D50 that is faster than manual measurements and more site-specific than predictions based on catchment characteristics. Methods: To understand the potential role of object detection methods for improving understanding of D50, we compared D50 estimates made manually, predicted from catchment characteristics, and using a YOLO-enabled approach across the Yakima River Basin. Results: We found distinct differences between methods for D50 averages and variability, and relationships between D50 estimates and basin characteristics. Discussion: We discuss the advantages and limitations of object detection methods versus current methods, and explore potential future directions to combine D50 methods to better estimate spatiotemporal variation of D50, and improve incorporation into basin-scale models.

grain size distribution↗

Subspace Methods in Multi-Parameter Seismic Full Waveform Inversion

In full waveform inversion (FWI) high-resolution subsurface model parameters are sought. FWI is normally treated as a nonlinear least-squares inverse problem, in which the minimum of the corresponding misfit function is found by updating the model parameters. When multiple elastic or acoustic properties are solved for, simple gradient methods tend to confuse parameter classes. This is referred to as parameter cross-talk; it leads to incorrect model solutions, poor convergence and strong dependence on the scaling of the different parameter types. Determining step lengths in a subspace domain, rather than directly in terms of gradients of different parameters, is a potentially valuable approach to address this problem. The particular subspace used can be defined over a span of different sets of data or different parameter classes, provided it involves a small number of vectors compared to those contained in the whole model space. Additionally, in a subspace method, the basis vectors are defined first, and a local minimum is found in the space spanned by these. We examine the application of the subspace method within acoustic FWI in determining simultaneously updates for velocity and density. We first discuss the choice of basis vectors to construct the spanned space, from linear updates by distinguishing only the contributions of different parameter classes towards nonlinear updates by adding the contributions of higher-order perturbations of each parameter class. The numerical character of FWI solutions generated via subspace methods involving different basis vectors is then analyzed and compared with traditional FWI methods. The subspace methods can provide better reconstructions of the model, especially for the velocity, as well as improved convergence rates, while the computational costs are still comparable with the traditional FWI methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperspectral Image Classification Using Graph Clustering Methods

Hyperspectral imagery is a challenging modality due to the dimension of the pixels which can range from hundreds to over a thousand frequencies depending on the sensor. Most methods in the literature reduce the dimension of the data using a method such as principal component analysis, however this procedure can lose information. More recently methods have been developed to address classification of large datasets in high dimensions. This paper presents two classes of graph-based classification methods for hyperspectral imagery. Using the full dimensionality of the data, we consider a similarity graph based on pairwise comparisons of pixels. The graph is segmented using a pseudospectral algorithm for graph clustering that requires information about the eigenfunctions of the graph Laplacian but does not require computation of the full graph. We develop a parallel version of the Nyström extension method to randomly sample the graph to construct a low rank approximation of the graph Laplacian. With at most a few hundred eigenfunctions, we can implement the clustering method designed to solve a variational problem for a graph-cut-based semi-supervised or unsupervised classification problem. We implement OpenMP directive-based parallelism in our algorithms and show performance improvement and strong, almost ideal, scaling behavior. The method can handle very large datasets including a video sequence with over a million pixels, and the problem of segmenting a data set into a pre-determined number of classes.

47 OTHER INSTRUMENTATION↗