Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

ULTIMATE FY22 Creep Test Facility Report (FY23 ARPA-E Milestone Report)

In the 18-month Phase 1 of this project, a facility was assembled for creep testing of refractory metals at 1300°C. This report focuses on the four creep frames that are operational and using an inert gas system (argon) to limit oxidation of the refractory metal specimens being tested. This report details the operations for the first period of operation including the results and lessons learned for Nb- and Mo-based alloy specimens tested by the ORNL team. For an alloy development program, a particularly unique feature of the ORNL facility is more than 40 years of experience conducting mechanical properties testing on sub-sized test specimens (25 mm long dogbones). Due to proprietary constraints, only one representative set of team data are provided. The primary concern for testing Nb-based alloys is oxygen ingress. Despite several strategies to reliably limit O ingress, including getters and Ar gas purity, the experimentally informed strategy currently being developed is a new load train design intended to better seal the system. Hardware for the new design is currently being fabricated.

36 MATERIALS SCIENCE↗

Assessing Nutrient and Carbon Responses to Agricultural Conservation Practices in Two Midwest Watersheds

The United States is undertaking efforts to transition to a low-carbon economy in response to the heightened impacts of climate change, which are largely attributed to decades of carbon-intensive development. A concerted effort by the energy sector to achieve net-zero carbon emissions is aimed at strategically reducing the carbon footprint of the energy supply chain, particularly in the production of feedstocks for biofuels. The production of biofuels relies heavily on land use and management practices in biomass cultivation. Among other factors, soil organic carbon (SOC) plays a crucial role in the biofuel carbon cycle, impacting land productivity, greenhouse gas emissions, and water quality. The process of carbon drawdown during plant growth and storage helps to mitigate the release of carbon dioxide (CO 2 ) into the atmosphere. Another key parameter is the release of nitrous oxide (N 2 O) — a potent greenhouse gas with a global warming potential 273 times that of CO 2 — from soil. While prioritizing low-carbon production, sustainable bioenergy also necessitates improved water quality and ecosystem services. Agricultural conservation practices can contribute to enhanced soil health and reduce nutrient and sediment loss into streams. However, studies that explore the broader impact of these practices on soil carbon storage and N 2 O emissions at a watershed scale are limited. Specifically, our understanding of how low-carbon feedstock production and management affect nutrient cycle dynamics is incomplete. This study assesses watershed responses to land management practices in two agriculturally dominant watersheds: the Raccoon River watershed and the Southfork of Iowa River watershed. The study focuses on carbon and nutrient dynamics, characterizing spatial and temporal variations in SOC, N 2 O, and nutrient loadings to examine the relationship between nutrient and carbon responses and agricultural conservation practices. The study employs the newly developed Soil Water Analysis Tool for Carbon (SWAT-C) model, calibrated using 20 years’ of climate and water monitoring data, to simulate and evaluate two agricultural conservation practices: no-till and crop residue harvest with cover crop planting. We compared the calibrated SWAT-C model with a historical baseline model, which allowed us to analyze various aspects of the watershed, including stream flow, suspended sediments, nitrogen, phosphorus, organic carbon, SOC at different depths, and N 2 O emissions from topsoil. Our SWAT-C modeling results indicate that, compared with results from the historical baseline model, no-till practices are positively correlated with SOC accumulation, reduced N 2 O emissions, and decreased soil loss. We also observed no change or slightly increased nitrogen and phosphorus loss to water bodies in the watersheds compared with the baseline. Conversely, crop residue harvest with cover crop planting improved water quality by reducing nutrient and soil losses but also increased N 2 O emissions. This SWAT-C modeling study establishes the groundwork for further smaller-scale and/or sub-basin-level assessments of nitrogen, phosphorus, and carbon cycles. It provides valuable science-based insights to inform policy decisions — particularly in the context of transitioning to biofuel feedstock production in these watersheds — by addressing concerns about nutrient exports to local water bodies and, ultimately, the Mississippi River.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase II Development of the Surveillance Test Articles to Improve the Design, Fabrication, and Testing

Advanced reactors, such as the molten salt reactor (MSR), require materials that will withstand harsher environments than the materials used for lower temperature water reactors. Materials used in MSR construction need not only withstand elevated temperature, temperature cycling, and neutron radiation, but must be able to withstand the corrosive molten salt environment. Significant materials research has been driven by the materials needs of the MSR due to the harsh environment and the material data requirements to support licensing. Limited operation experience with MSRs has made this challenging work. Information is very limited on materials degradation due to irradiation, molten salt corrosion, elevated temperature, and the resulting fatigue, creep, and creep-fatigue loading during operation. While efforts are underway to better understand the effects of this harsh environment on construction materials, the Advanced Reactors Technologies (ART) Program has been working to develop materials surveillance test articles that could be used in a materials surveillance program and allow for the collection of information on the materials degradation during plant operation and could support timely licensing of these advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Introduction to the Demonstration of Pyroshock Response Prediction Methods Using NASA ShockSat Data Virtual Collection

Mechanical shocks, particularly pyroshocks, are environments that all spacecraft and launch vehicles experience. Pyroshocks can be challenging design environments for space hardware because these events are often high frequency, high intensity transients. Furthermore, since design decisions must be made relatively early in the design phase, understanding, and accurately defining pyroshock excitation and the loads that it imparts on components is important to ensure the high reliability required of spacecraft and rockets. Here, general guidelines about shock transmission through spacecraft structures are provided in NASA and MIL handbooks and standards, but these are relatively broad guidelines, and recent studies have shown that more accurate and less-conservative predictions are needed. However, predicting shock response accurately is still a challenge because of the high frequencies in a pyroshock excitation.

Babuska, Vit [Sandia National Laboratories (SNL-NM↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

BISON validation of FeCrAl cladding mechanical failure during simulated reactivity-initiated accident conditions*

Here, a reactivity-initiated accident (RIA) is a postulated design basis accident in light water reactors (LWRs) in which a rapid reactivity insertion induces a fission rate increase and a fuel pellet temperature rise. During RIA, the fuel pellet thermally expands and may cause pellet-cladding mechanical interaction (PCMI). Separate effects PCMI tests were performed on C26M FeCrAl cladding tube samples, introducing biaxial stress via a well understood modified burst test (MBT) system. A high-speed camera in the MBT system captured the projections, covering a 360° view of the cladding deformation and enabling a digital image correlation (DIC) method to quantify the surface strains with high fidelity. Representative hot zero-power RIA mechanical loading conditions were applied to the sample, and the test duration ranged from 20 to 500 ms at an average temperature of 573 K. BISON finite element–based fuel performance code modeling was performed against the high-fidelity DIC data produced from the MBTs. Validation calculations were conducted with 2D models and systematically compared with test data of the burst time, burst pressure, burst hoop strains, and hoop strain rates. Based on the behaviors from the separate effects test, BISON calculations satisfactorily predicted the cladding deformation behaviors. Sensitivity analysis was conducted to identify highly influential mechanical properties responsible for the cladding failure behavior during the MBT experiments. The results highlight the significance of the cladding's mechanical strength in governing cladding strain, followed by the significance of the mechanical interactions between the pellet and the cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An updated technique to obtain explosive kinetics data on microsecond timescales

There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ~1000 K on microsecond timescales. Wenograd loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy

Due to its nonlinear nature, the supply fan at air handling units with the controller tuned at the design condition tends to be aggressive and oscillate under partial load conditions. Here, the objective of this paper is to develop and validate a gain scheduling control strategy to improve its nonlinear control performance. First, a control-oriented model, which does not require numerous physical parameters and extensive test data, is developed to study the nonlinearity of the fan system. Based on the theoretical model and experimental verifications, the issue of an aggressive response with a conventional fixed-gain controller is caused by the fact that the system gain is proportional to the ratio of the duct static pressure to the fan speed. To address the issue, a scheduling function of the measurable duct static pressure and fan speed is proposed to be included in the conventional fixed-gain controller to compensate for the fan system gain variation. The gain scheduling control strategy is found to approximately maintain the identical control performance under all operation conditions. Most importantly, the gain scheduling control strategy can be readily implemented without intensive computation and additional measurements, showing a promising potential in industrial applications.

42 ENGINEERING↗

Verification of the AGREE and Serpent for the steady state HTR-10 benchmark problems

This paper provides results from steady state HTR-10 benchmark calculations performed using AGREE and Serpent that are compared to experimental results as well as calculations performed by INET. The purpose of completing this benchmark is to validate AGREE and Serpent for the prediction of HTGR operation so that they may ultimately be used to support licensing and deployment efforts of advanced reactors. The benchmark consists of several problems ranging from control rod worth calculations to k{sub eff} calculations at various temperatures. Overall, AGREE and Serpent show good agreement with the reference solutions and are effectively able to predict HTGR operation for a variety of steady state cases. The largest difference from the reference was for the initial core single rod worth, which is possibly due to the larger core helium cavity causing inaccuracies in the diffusion calculation whereas the control rod worth determined by Serpent and AGREE is much closer to the reference result for the full core loading. Moreover, in every benchmark problem, increasing the number of energy groups in the cross sections results in improved agreement of the AGREE result with the reference, although it also causes an increase in computation time. For problems with experimental data available, the accuracy of results generated by Serpent and AGREE is comparable to results obtained by other benchmark participants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EGS Collab Experiment 2: 4100 Foot Level Elastic Property Data

Static and dynamic elastic properties (Young's modulus, Shear Modulus, P-wave Modulus, and Poisson's Ratio) of amphibolites and rhyolites from the TV4100 and TH4100 boreholes at the Sanford Underground Research Laboratory (SURF). Elastic properties include Young's modulus, Poisson's ratio, shear modulus, and p-wave modulus. Raw data from the experiments and slides describing the experimental procedure and a summary of results are included, along with a readme file with additional definitions and information.

15 GEOTHERMAL ENERGY↗

Summary of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Environmental Effects on Ventilated Spent Fuel Storage Systems

This report describes newly developed external environment wind effects models of spent nuclear fuel (SNF) dry storage systems. The primary purpose of these wind effects models is to better understand particle deposition on SNF canisters in the context of chloride-induced stress corrosion cracking. The goal of this effort is to further the understanding and improve the wind effects model of the Nuclear Horizontal Modular Storage (NUHOMS ® ) Advanced Horizontal Storage Module–High Seismic (AHSM-HS) storage system in support of the planned Canister Deposition Field Demonstration (CDFD) project (Durbin et al. 2021, Suffield et al. 2021). The steps in this wind effects investigation begin with a validation case of comparing experimental data with a STAR-CCM+ computational fluid dynamics (CFD) model of the Belowground Vertical Dry Cask Simulator (BVDCS) with the external environment explicitly modeled. Next, a test case is performed with the AHSM-HS models comparing solar-loading strategies for a standalone and wind effects model in STAR-CCM+ and a standalone model in ANSYS Mechanical Parametric Design Language (APDL). The final portion of this study compares results of the validation exercise with applications of wind effects models for two horizontal storage systems, a site specific NUHOMS ® horizontal storage module and a NUHOMS ® AHSM-HS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of multimode range and location on urban fuel economy on a light-duty spark-ignition based powertrain using vehicle system simulations

Multimode engine operation uses two or more combustion modes to maximize engine efficiency across the operational range of a vehicle to achieve higher overall vehicle fuel economy than is possible with a single combustion mode. More specifically for this study, multimode solutions are explored that make use of boosted SI under high load operation and other advanced combustion modes such as advanced compression ignition (ACI) under part-load conditions to enable additional engine efficiency improvements across a broader range of the engine operating map. ACI combustion has well-documented potential to improve efficiency and emissions under part-load operation but poses challenges that limit full engine speed-load range. This study investigates the potential impact of ACI operational range on simulated fuel economy to help focus research on areas with the most opportunity for improving fuel economy. These simulations make use of a vehicle model, discretized engine data, and employ a systematic exploration of ACI operational range to estimate multimode fuel economy for a mid-size passenger vehicle over U.S. Environmental Protection Agency’s Urban Dynamometer Driving Schedule. The results of this study highlight operational ranges with the highest potential fuel economy and correspondingly areas of focus for multimode research and ACI engine operation1.

Curran, Scott↗