Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Experimental Photoionization Cross-section Measurements in the Ground and Metastable State Threshold Region of Seplus

Absolute photoionization cross-section measurements are reported for Se{sup +} in the photon energy range 18.0-31.0 eV, which spans the ionization thresholds of the {sup 4}S{sub 3/2} ground state and the low-lying {sup 2}P{sub 3/2, 1/2} and {sup 2}D{sub 5/2, 3/2} metastable states. The measurements were performed using the Advanced Light Source synchrotron radiation facility. Strong photoexcitation-autoionization resonances due to 4p {yields} nd transitions are seen in the cross-section spectrum and identified with a quantum-defect analysis.

43 PARTICLE ACCELERATORS↗

Near-threshold absolute photoionization cross-sections of some reaction intermediates in combustion

The use of photoionization mass spectrometry for the development of quantitative kinetic models for the complex combustion chemistry of both conventional hydrocarbon fuels and oxygenated biofuels requires near-threshold measurements of absolute photoionization cross-sections for numerous reaction intermediates. Near-threshold absolute cross-sections for molecular and dissociative photoionization for 20 stable reaction intermediates (methane, ethane, propane, n-butane, cyclopropane, methylcyclopentane, 1-butene, cis-2-butene, isobutene, 1-pentene, cyclohexene. 33 -dimethyl-1-butene, 1,3-hexadiene, 1,3-cyclohexadiene, methyl acetate, ethyl acetate, tetrahydrofuran, propanal, 1-butyne, 2-butyne) are presented. Previously measured total photoionization cross-sections for 9 of these molecules are in good agreement with the present results. The measurements are performed with photoionization mass spectrometry (PIMS) using a monochromated VUV synchrotron light source with an energy resolution of 40 meV (fwhm) comparable to that used for flame-sampling molecular beam PIMS studies of flame chemistry and reaction kinetics.

10 SYNTHETIC FUELS↗

Optimization of a Seeded Free-Electron Laser with Helical Undulators

Seeded single pass free-electron lasers are promising coherent, short-duration, and intense light sources, from the visible to x rays. Operated with adjustable undulators, they are also a unique device for providing fully variable polarized radiation. We report here the first seeding of helical undulators with a variable polarized source. We demonstrate that the adjustment of the seed polarization and focusing allows the free-electron laser radiation to be optimized in terms of intensity and quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

At-wavelength and optical metrology of bendable x-ray optics for nanofocusing at the ALS

We report on a new research and development program at the Advanced Light Source, Lawrence Berkeley National Lab directed to establish both at-wavelength and conventional optical metrology techniques suitable to characterize the surface profile of super-high-quality x-ray optics with sub-microradian precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the optical properties of a pulse-periodic high-pressure cesium discharge

Results of theoretical and experimental studies of the optical spectrum of a pulse-periodic high-pressure cesium discharge are presented. The results of calculations are in good agreement with experimental data. The possibility of creating an efficient light source based on recombination emission from the discharge plasma is demonstrated. The formation mechanisms of the continuous spectrum of discharge radiation are considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Assisted Emittance Exchange

We describe here the laser assisted emittance exchange (LAEE) technique. A laser operating in the transverse mode (TEM10 or TEM01) is used to interact with the electron beam in a dispersive region and to initiate the transverse-to-longitudinal emittance exchange. It is shown that with the LAEE one can generate an electron beam with ultralow transverse emittance, which allows one to significantly bring down the size of an X-ray free electron laser (FEL) and greatly extend the availability of these light sources. The technique can also be used to enhance the performances of X-ray FELs in storage rings. The timing and energy jitter problems for the standard emittance exchange and LAEE techniques are also discussed.

43 PARTICLE ACCELERATORS↗

Spatial resolution limits for synchrotron-based infrared spectromicroscopy

Detailed spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source synchrotron facility in Berkeley, CA. The high-brightness synchrotron source is coupled at this beamline to a Thermo-Electron Continumum XL infrared microscope. Two types of resolution tests in both the mid-IR (using a KBr beamsplitter and an MCT-A* detector) and in the near-IR (using a CaF2 beamsplitter and an InGaAS detector) were performed and compared to a simple diffraction-limited spot size model. At the shorter wavelengths in the near-IR the experimental results begin to deviate from only diffraction-limited. The entire data set is fit using a combined diffraction-limit and demagnified electron beam source size model. This description experimentally verifies how the physical electron beam size of the synchrotron source demagnified to the sample stage on the endstation begins to dominate the focussed spot size and therefore spatial resolution at higher energies. We discuss how different facilities, beamlines, and microscopes will affect the achievable spatial resolution.

43 PARTICLE ACCELERATORS↗

HIGH-LEVEL CONTROL SYSTEM IN C#

We have started upgrading the control room programs for the injector at the Advanced Light Source (ALS). We chose to program in C* exclusively on the .NET Framework to create EPICS client programs on Windows Vista PCs. This paper reports the status of this upgrade project.

43 PARTICLE ACCELERATORS↗

Steady-State Microbunching in a Storage Ring for Generating Coherent Radiation

Synchrotrons and storage rings deliver radiation across the electromagnetic spectrum at high repetition rates, and free electron lasers (FELs) produce radiation pulses with high peak brightness. However, at present few light sources can generate both high repetition rate and high brightness outside the optical range. We propose to create steady-state microbunching (SSMB) in a storage ring to produce coherent radiation at a high repetition rate or in continuous wave (CW) mode. In this paper we describe a general mechanism for producing SSMB and give sample parameters for EUV lithography and sub-millimeter sources. We also describe a similar arrangement to produce two pulses with variable spacing for pump-probe experiments. With technological advances, SSMB could reach the soft X-ray range (< 10 nm).

43 PARTICLE ACCELERATORS↗

Dual-wavelength excited photoluminescence spectroscopy of deep-level hole traps in Ga(In)NP

By employing photoluminescence (PL) spectroscopy under dual-wavelength optical excitation, we uncover the presence of deep-level hole traps in Ga(In)NP alloys grown by molecular beam epitaxy (MBE). The energy level positions of the traps are determined to be at 0.56 eV and 0.78 eV above the top of the valance band. We show that photo-excitation of the holes from the traps, by a secondary light source with a photon energy below the bandgap energy, can lead to a strong enhancement (up to 25%) of the PL emissions from the alloys under a primary optical excitation above the bandgap energy. We further demonstrate that the same hole traps can be found in various MBE-grown Ga(In)NP alloys, regardless of their growth temperatures, chemical compositions, and strain. The extent of the PL enhancement induced by the hole de-trapping is shown to vary between different alloys, however, likely reflecting their different trap concentrations. The absence of theses traps in the GaNP alloy grown by vapor phase epitaxy suggests that their incorporation could be associated with a contaminant accompanied by the N plasma source employed in the MBE growth, possibly a Cu impurity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The FERMI@Elettra free-electron-laser source for coherent X-ray physics: photon properties, beam transport system, and applications

FERMI@Elettra is comprised of two free electron lasers (FELs) that will generate short pulses (tau ~;; 25 to 200 fs) of highly coherent radiation in the XUV and soft X-ray region. The use of external laser seeding together with a harmonic upshift scheme to obtain short wavelengths will give FERMI@Elettra the capability to produce high quality, longitudinal coherent photon pulses. This capability together with the possibilities of temporal synchronization to external lasers and control of the output photon polarization will open new experimental opportunities not possible with currently available FELs. Here we report on the predicted radiation coherence properties and important configuration details of the photon beam transport system. We discuss the several experimental stations that will be available during initial operations in 2011, and we give a scientific perspective on possible experiments that can exploit the critical parameters of this new light source.

36 MATERIALS SCIENCE↗

Single shot x-ray phase contrast imaging using a direct conversion microstrip detector with single photon sensitivity

X-ray phase contrast imaging enables the measurement of the electron density of a sample with high sensitivity compared to the conventional absorption contrast. This is advantageous for the study of dose-sensitive samples, in particular, for biological and medical investigations. Recent developments relaxed the requirement for the beam coherence, such that conventional X-ray sources can be used for phase contrast imaging and thus clinical applications become possible. One of the prominent phase contrast imaging methods, Talbot-Lau grating interferometry, is limited by the manufacturing, alignment, and photon absorption of the analyzer grating, which is placed in the beam path in front of the detector. We propose an alternative improved method based on direct conversion charge integrating detectors, which enables a grating interferometer to be operated without an analyzer grating. Algorithms are introduced, which resolve interference fringes with a periodicity of 4.7 μm recorded with a 25 μm pitch Si microstrip detector (GOTTHARD). The feasibility of the proposed approach is demonstrated by an experiment at the TOMCAT beamline of the Swiss Light Source on a polyethylene sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A particle-in-cell plus Monte Carlo study of plasma-induced damage of normal incidence collector optics used in extreme ultraviolet lithography

We present a kinetic simulation of the plasma formed by photoionization in the intense flux of an extreme ultraviolet lithography (EUVL) light source. The model is based on the particle-in-cell plus Monte Carlo approach. The photoelectric effect and ionization by electron collisions are included. The time evolution of the low density argon plasma is simulated during and after the EUV pulse and the ion-induced sputtering of the coating material of a normal incidence collector mirror is computed. The relation between the time and position at which the ions are created and their final energy is studied, revealing how the evolution and the properties of the sheath influence the amount of sputtered material. The influence of the gas pressure and the source intensity is studied, evaluating the behavior of Ar{sup +} and Ar{sup 2+} ions. A way to reduce the damage to the collector mirror is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A planar refractive x-ray lens made of nanocrystalline diamond

Diamond has unique properties which make it the ideal material for use in synchrotron instrumentation. X-ray optics made of diamond are almost transparent, they possess strength, and are subject to very low thermal expansion; therefore they will be able to withstand the powerful beams generated by fourth-generation light sources without compromising brilliance. For this reason, several groups are attempting fabrication of refractive lenses and zone plates made of diamond. Lithography and, in general, microfabrication technology, are the ultimate tools for the innovation of synchrotron focusing optics. We propose to combine modern silicon microtechnology with advanced deposition methods to fabricate nanocrystalline-diamond lenses for third- and fourth-generation synchrotron sources. The fabrication method is described here and microfocusing synchrotron tests are illustrated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

ISPyB for BioSAXS, the gateway to user autonomy in solution scattering experiments

The ISPyB information-management system for crystallography has been adapted to include data from small-angle X-ray scattering of macromolecules in solution experiments. Logging experiments with the laboratory-information management system ISPyB (Information System for Protein crystallography Beamlines) enhances the automation of small-angle X-ray scattering of biological macromolecules in solution (BioSAXS) experiments. The ISPyB interface provides immediate user-oriented online feedback and enables data cross-checking and downstream analysis. To optimize data quality and completeness, ISPyBB (ISPyB for BioSAXS) makes it simple for users to compare the results from new measurements with previous acquisitions from the same day or earlier experiments in order to maximize the ability to collect all data required in a single synchrotron visit. The graphical user interface (GUI) of ISPyBB has been designed to guide users in the preparation of an experiment. The input of sample information and the ability to outline the experimental aims in advance provides feedback on the number of measurements required, calculation of expected sample volumes and time needed to collect the data: all of this information aids the users to better prepare for their trip to the synchrotron. A prototype version of the ISPyBB database is now available at the European Synchrotron Radiation Facility (ESRF) beamline BM29 and is already greatly appreciated by academic users and industrial clients. It will soon be available at the PETRA III beamline P12 and the Diamond Light Source beamlines I22 and B21.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the Electronic Configuration in Pu

X-Ray Absorption Spectroscopy (XAS) and Photoelectron Spectroscopy (PES) have been performed upon highly radioactive samples, particularly Plutonium, at the Advanced Light Source in Berkeley, CA, USA. First results from alpha and delta Plutonium are reported as well as a detailed analysis of sample quality.

43 PARTICLE ACCELERATORS↗