Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Revisions to ANSI Z136.1-2007 : safe use of lasers.

The parent document and cornerstone of the Z136 series of laser safety standards, the revised ANSI Z136.1 (2007) provides guidance for the safe use of lasers and laser systems by defining control measures for each of the four laser classes. As a result of advances in laser devices and applications, new guidelines have been incorporated into this 2007 revision. The new revision should be obtained by all laser end users and is a must for users of class 3B and 4 lasers as it renders all previous editions obsolete. Since the ANSI Z136.1 standard is the foundation of laser safety programs for industrial, military, medical, and educational applications nationwide, revisions to the previous version can and will affect the training and practice of laser safety in these environments. Changes to the previous version include the addition of new laser hazard classification definitions, new requirements for refresher training, and changes to medical surveillance requirements. The ANSI Z136.1 (2007) standard provides an updated and thorough set of guidelines for implementing a safe laser program. In addition to these changes, the standard covers laser safety program provisions including the duties and responsibilities of the LSO, non-beam hazards, administrative/engineering control measures, definitions, optical density, nominal hazard zone (NHZ), MPEs, accessible emission limit (AEL), bioeffects, standard operating procedures (SOPs), and example calculations.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing extreme ultraviolet photons emission in laser produced plasmas for advanced lithography

Current challenges in the development of efficient laser produced plasma sources for the next generation extreme ultraviolet lithography (EUVL) are increasing EUV power and maximizing lifetime and therefore, reducing cost of devices. Mass-limited targets such as small tin droplets are considered among the best choices for cleaner operation of the optical system because of lower mass of atomic debris produced by the laser beam. The small diameter of droplets, however, decreases the conversion efficiency (CE) of EUV photons emission, especially in the case of CO{sub 2} laser, where laser wavelength has high reflectivity from the tin surface. We investigated ways of improving CE in mass-limited targets. We considered in our modeling various possible target phases and lasers configurations: from solid/liquid droplets subjected to laser beam energy with different intensities and laser wavelength to dual-beam lasers, i.e., a pre-pulse followed by a main pulse with adjusted delay time in between. We studied the dependence of vapor expansion rate, which can be produced as a result of droplet heating by pre-pulse laser energy, on target configuration, size, and laser beam parameters. As a consequence, we studied the influence of these conditions and parameters on the CE and debris mass accumulation. For better understanding and more accurate modeling of all physical processes occurred during various phases of laser beam/target interactions, plasma plume formation and evolution, EUV photons emission and collection, we have implemented in our heights package state-of-the art models and methods, verified, and benchmarked against laboratory experiments in our CMUXE center as well as various worldwide experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of high-power laser radiation with low-density polymer aerogels

The interaction of high-power subnanosecond laser pulses with low-density targets of cellulose triacetate polymer is considered. An Nd-glass laser setup provides a focal spot intensity of over 10{sup 14} W cm{sup −2}. An investigation is made of absorption of laser radiation, laser-to-X-ray energy conversion, spectra of ions emitted from the plasma, transmission of laser radiation through the target and plasma, as well as volume heating of the target material. It is experimentally determined that the laser energy conversion efficiency to X-rays with photon energies of a few Kiloelectronvolts decreases with increasing target material density. With the use of targets of density 10 mg cm{sup −3} this efficiency is two times lower in comparison to 2 mg cm{sup −3} density targets. The duration and amplitude of laser pulses transmitted through the target decreases with increasing column target density (the product of target material density and its thickness). The spectra of ions emitted from low-density target plasmas are recorded using ion collectors positioned at different angles relative to the direction of laser beam propagation as well as a high-resolution Thomson mass spectrometer. The ion flux and ion energies are found to increase with increasing target material density. The peak of the ion energy spectrum is shifted towards higher energies with increasing laser radiation intensity. (interaction of laser radiation with matter. laser plasma)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid-state Laser Development for the in Situ Spectroscopic Europa Explorer Instrument

The in Situ Spectroscopic Europa Explorer (iSEE) instrument is an ultra-compact laser-enabled Raman spectrometer instrument that meets the top-level science requirements for multiple future planetary in situ missions to explore the surface and atmospheric chemistry of planetary bodies across the Solar System. Enceladus, Europa, the Moon, Mars, and Venus are some of the primary targets for future NASA missions to search for extraterrestrial life and potentially habitable environments beyond Earth, further our understanding of the timing and formation of the Solar System and identify potentially viable economic resources such as water and/or valuable metal assets. We report on the advancement and space flight qualification of a compact, robust, solid-state laser operating at 515 nm that serves as the excitation source for the iSEE investigation. The iSEE instrument is being developed under a NASA Maturation of Instruments for Solar System Exploration (MatISSE) program. The iSEE laser is a diode pumped 1030 nm Yb:YAG microchip laser with a second harmonic generator to achieve an output wavelength of 515 nm and coupled to a multi-mode fiber for delivery to the Raman spectrometer probe. The fundamental 1030 nm laser operates at a pulse repetition frequency (PRF) of 1-10 kHz with pulse energy of 95 μJ and ~800 ps pulse width. A 15 mm long Type II KTP crystal is used for second harmonic generation from 1030 nm to 515 nm. The residual fundamental 1030 nm is separated from the 515 nm beam using a pair of dichroic filters. A focusing lens couples the 515 nm beam to the optical fiber to produce an output laser pulse energy of 20 μJ. A custom vacuum fiber feedthrough assembly was designed with two 105 μm core fibers, and two 200 μm core fibers. One fiber is needed for coupling the laser to the iSEE instrument, and the additionally fibers provide redundancy and design flexibility. The laser enclosure is pressurized with >1 atm of clean dry air. The laser has been designed to minimize the size, weight, and power (SWaP) for a lander instrument with minimal resources. The laser will go through environmental testing including vibration and thermal vacuum testing for space flight qualification. Here we discuss the design, trade studies, performance, and environmental qualificationtesting of the iSEE laser.

Solid state laser, Raman spectrometer, visible las↗

CO{sub 2} Laser Ablation Area Scaling And Redeposition On Flat Polyoxymethylene Targets

One of the remaining unknown subjects of laser propulsion involves whether special benefits or challenges exist for applying laser ablation propulsion to targets with particularly large or small spot areas. This subject is of high importance for a wide range of topics ranging from laser removal of space debris to micropropulsion for laser propulsion vehicles. Analysis is complex since different ablation phenomena are dominant between atmosphere and vacuum conditions. Progress has also been impeded by the difficulty of setting control parameters (particularly fluence) constant while the spot area is adjusted. It is also usually difficult for one group to address small- and large-area effects using a single high-power laser system. Recent collaborative experiments on laser ablation area scaling at several institutions, using 100-J class and 10-J class CO{sub 2} lasers, have advanced the understanding of laser propulsion area scaling. The spot area-dependence of laser propulsion parameters has been investigated over an area range covering approximately 0.05-50 cm{sup 2} at low fluence of about 0.6 J/cm{sup 2}. The experiments were conducted well below the threshold for plasma formation, and provide an estimate of the ablation threshold for CO{sub 2} laser ablation of POM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Morphology and orientation of β-BaB{sub 2}O{sub 4} crystals patterned by laser in the inside of samarium barium borate glass

Nonlinear optical β-BaB{sub 2}O{sub 4} crystal lines (β-BBO) were patterned in the inside of 8Sm{sub 2}O{sub 3}–42BaO–50B{sub 2}O{sub 3} glass by irradiations of continuous-wave Yb:YVO{sub 4} lasers with a wavelength of 1080 nm (power: P=0.8–1.0 W, scanning speed: S=0.2–2.5 μm/s), in which the laser focal position was moved gradually from the surface to the inside. The morphology, size, and orientation of β-BBO crystals were examined from polarization optical microscope and birefringence imaging observations. It was demonstrated that c-axis oriented β-BBO crystals with long lengths (e.g., 20 mm) were patterned in the inside of the glass. The morphology of β-BBO in the cross-section of lines was a rectangular shape with rounded corners, and the volume of β-BBO formed increased with increasing laser power and with decreasing laser scanning speed. The maximum depth in the inside from the surface for β-BBO patterning increased with increasing laser power, e.g., D{sub max}∼100 μm at P=0.8 W, D{sub max}∼170 μm at P=0.9 W, and D{sub max}∼200 μm at P=1 W. The present study proposes that the laser-induced crystallization opens a new door for applied engineering in glassy solids. - Graphical abstract: This figure shows the POM photographs for β-BaB{sub 2}O{sub 4} crystal lines patterned by cw Yb:YVO{sub 4} fiber laser irradiations with a laser power of P=0.8 W and a laser scanning speed S=2 μm/s in the glass. The laser focal point was moved gradually from the surface into the inside. The results shown in Fig. 1 demonstrate that it is possible to pattern highly oriented β-BaB{sub 2}O{sub 4} crystals even in the inside of glasses. - Highlights: • β-BaB{sub 2}O{sub 4} crystal lines were patterned in the inside of a glass by lasers. • Laser focal position was moved gradually from the surface to the inside. • Birefringence imaging was observed. • Morphology, size, and orientation of crystals were clarified. • Crystal lines with long lengths (e.g., 20 mm) were patterned at the depth of 200 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams

Purpose: Laser plasma acceleration can potentially replace large and expensive cyclotrons or synchrotrons for radiotherapy with protons and ions. On the way toward a clinical implementation, various challenges such as the maximum obtainable energy still remain to be solved. In any case, laser accelerated particles exhibit differences compared to particles from conventional accelerators. They typically have a wide energy spread and the beam is extremely pulsed (i.e., quantized) due to the pulsed nature of the employed lasers. The energy spread leads to depth dose curves that do not show a pristine Bragg peak but a wide high dose area, making precise radiotherapy impossible without an additional energy selection system. Problems with the beam quantization include the limited repetition rate and the number of accelerated particles per laser shot. This number might be too low, which requires a high repetition rate, or it might be too high, which requires an additional fluence selection system to reduce the number of particles. Trying to use laser accelerated particles in a conventional way such as spot scanning leads to long treatment times and a high amount of secondary radiation produced when blocking unwanted particles. Methods: The authors present methods of beam delivery and treatment planning that are specifically adapted to laser accelerated particles. In general, it is not necessary to fully utilize the energy selection system to create monoenergetic beams for the whole treatment plan. Instead, within wide parts of the target volume, beams with broader energy spectra can be used to simultaneously cover multiple axially adjacent spots of a conventional dose delivery grid as applied in intensity modulated particle therapy. If one laser shot produces too many particles, they can be distributed over a wider area with the help of a scattering foil and a multileaf collimator to cover multiple lateral spot positions at the same time. These methods are called axial and lateral clustering and reduce the number of particles that have to be blocked in the beam delivery system. Furthermore, the optimization routine can be adjusted to reduce the number of dose spots and laser shots. The authors implemented these methods into a research treatment planning system for laser accelerated particles. Results: The authors' proposed methods can decrease the amount of secondary radiation produced when blocking particles with wrong energies or when reducing the total number of particles from one laser shot. Additionally, caused by the efficient use of the beam, the treatment time is reduced considerably. Both improvements can be achieved without extensively changing the quality of the treatment plan since conventional intensity modulated particle therapy usually includes a certain amount of unused degrees of freedom which can be used to adapt to laser specific properties. Conclusions: The advanced beam delivery and treatment planning methods reduce the need to have a perfect laser-based accelerator reproducing the properties of conventional accelerators that might not be possible without increasing treatment time and secondary radiation to the patient. The authors show how some of the differences to conventional beams can be overcome and efficiently used for radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-484: A New Method of Aligning Patient Setup Lasers in Radiation Therapy

Purpose: To develop a new method to align the patient setup lasers in radiation therapy and examine its validity and effectiveness. Methods: The new laser alignment method was realized by a device composed of both a metallic base plate and few acrylic transparent plates with a cross hair line on each of them. The holders of radiochromic films were prepared in the device to find a radiation isocenter. The right laser positions could be found optically by matching the shadows of all the cross hairs in the gantry head and the device. The repeatability and reproducibility (R and R) of laser alignments and the dependency of the alignment on the position error of the light source were evaluated by comparing the standard deviations and the means of the measured laser positions. After aligning the lasers optically, a radiation isocenter was found by a collimator spoke shot and the gantry spoke shot, and then the lasers were parallely translated to the isocenter. Results: In the R and R test, the standard deviation was 1.14 mm for the new method whereas it was 1.49 mm or 2.76 mm for the conventional method with either high- or low-precision levels. In the test of the dependency on the position error of the light source, the mean laser position was shifted by 5.3 mm corresponding to the shift of the light source, 4.8 mm for the new method, but for the conventional method the laser position was shifted more than 7 times than that. The positional shift could be corrected by a parallel translation to the isocenter in the new method. Conclusion: A new laser alignment method was devised for radiation therapy and tested successfully. The method enabled us to align the lasers easily and accurately without repetition, and all lasers could be finally aligned to the radiation isocenter.

60 APPLIED LIFE SCIENCES↗

Compact, Efficient, Low-cost Lasers (CELL) Project (Final Report)

Development of clean, sustainable and affordable energy sources is a national and international challenge. Inertial Fusion Energy (IFE) may provide a transformational solution that is scalable, proliferation-resistant, and that generates negligible nuclear waste. To produce energy economically competitive with alternative power plants, the IFE laser drive must operate at a high repetition rate (≥10 Hz) with high efficiency (>10%), while maintaining beam quality suitable for focusing to a small spot suitable for compressing the fusion target. The NIF laser system meets the beam quality requirements using a solid-state gain medium pumped by flashlamps. Scaling from NIF to IFE requires increases of ~10 5 in rep rate and ~20X in efficiency, which adds significant challenges to the laser design. The increased repetition rate results in much more waste heat generated in the system, and the prevention of thermal beam quality degradation (through phenomena such as thermally-induced birefringence) becomes a critical issue. While thermal issues are mitigated by increasing the system volume, a major size increase renders the system less economical and less easy to site. LIFE laser efficiency targets can be achieved at high rep rate without reliability degradation by using diode lasers as pumps. An IFE plant requires ~10 8 diode laser bars. At current costs the diodes dominate the overall laser cost and render IFE less cost-effective. Thus, designing a compact and cost-effective laser system with the repetition rate, efficiency, and beam quality required for IFE presents a significant technical challenge. The goal of the CELL strategic initiative was to develop new laser architectures to address these challenges by leveraging recent advances in optical technology. New laser design options have become potentially feasible due to improvements in laser gain media, diode pumps, large aperture nonlinear optics, and damage-resistant optics that have occurred since NIF’s conception. The project investigated designs that take advantage of these advances, combining them with advanced and novel subsystem concepts to achieve laser designs with significantly improved performance, size, and cost.

42 ENGINEERING↗

Ultra-High-Contrast Laser Acceleration of Relativistic Electrons in Solid Targets

The cone-guided fast ignition approach to Inertial Con nement Fusion requires laser-accelerated relativistic electrons to deposit kilojoules of energy within an imploded fuel core to initiate fusion burn. One obstacle to coupling electron energy into the core is the ablation of material, known as preplasma, by laser energy proceeding nanoseconds prior to the main pulse. This causes the laser-absorption surface to be pushed back hundreds of microns from the initial target surface; thus increasing the distance that electrons must travel to reach the imploded core. Previous experiments have shown an order of magnitude decrease in coupling into surrogate targets when intentionally increasing the amount of preplasma. Additionally, for electrons to deposit energy within the core, they should have kinetic energies on the order of a few MeV, as less energetic electrons will be stopped prior to the core and more energetic electrons will pass through the core without depositing much energy. Thus a quantitative understanding of the electron energy spectrum and how it responds to varied laser parameters is paramount for fast ignition. For the rst time, this dissertation quantitatively investigates the acceleration of electrons using an ultra-high-contrast laser. Ultra-high-contrast lasers reduce the laser energy that reaches the target prior to the main pulse; drastically reducing the amount of preplasma. Experiments were performed in a cone-wire geometry relevant to fast ignition. These experiments irradiated the inner-tip of a Au cone with the laser and observed electrons that passed through a Cu wire attached to the outer-tip of the cone. The total emission of K x-rays is used as a diagnostic to infer the electron energy coupled into the wire. Imaging the x-ray emission allowed an e ective path-length of electrons within the wire to be determined, which constrained the electron energy spectrum. Experiments were carried out on the ultra-high-contrast Trident laser at Los Alamos National Laboratory and at the low-contrast Titan laser at Lawrence Livermore National Laboratory. The targets were irradiated using these 1.054 μm wavelength lasers at intensities from 1019 to 1020 W/cm2. The coupling of energy into the Cu wire was found to be 2.7x higher when the preplasma was reduced using high-contrast. Additionally, higher laser intensity elongated the e ective path-length of electrons within the wire, indicating that their kinetic energy was higher.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Laser apparatus

A laser apparatus having a pump laser device for producing pump laser energy upon being excited is disclosed. The pump laser device has a resonating cavity for oscillating and amplifying the pump laser energy. A source laser device is used for producing source laser energy upon being excited by the pump laser energy. The source laser device has a resonating cavity for oscillating and amplifying the source laser energy. The source laser's resonating cavity is coupled within a portion of the pump laser's resonating cavity.

Koepf, G. A.↗

High repetition rate sealed CO2 TEA lasers using heterogeneous catalysts

The significant operational advantages offered by CO2 lasers, operating in the 10.6 micron region of the spectrum, over current solid state lasers, emitting in the near IR region, have prompted increased interest in the development of compact, reliable, rugged CO2 laser sources. Perhaps the most critical aspect associated with achieving a laser compatible with military use is the development of lasers which require no gas replenishment. Sealed, single shot, CO2 TEA lasers have been available for a number of years. Stark et al were first to demonstrate reliable sealed operation in single shot CO2 TEA lasers in 1975 using gas catalysis. GEC Avionics reported the compact, environmentally qualified, MKIII CO2 TEA laser with a pulse life of greater than 10 to the 6th power pulses in 1980. A sealed laser lifetime of greater than 10 to the 6th power pulses is acceptable for single shot cases, such as direct detection rangefinders for tank laser sights. However, in many other applications, such as tracking of fast moving targets, it is essential that a repetition rate of typically 30Hz to 100Hz is employed. In such cases, a pulse lifetime of 10 to the 6th power pulses is no longer sufficient and a minimum pulse lifetime 10 to the 7th power pulses is essential to ensure a useful service life. In 1983 Stark el al described a sealed, 100Hz CO2 TEA laser, with a life of greater than 2.6 x 10 to the 6th power, which employed heterogeneous catalysis. Following this pioneering work, GEC Avionics has been engaged in the development of sealed high repetition rate lasers with a pulse lifetime of 20 million pulses.

Price, H. T.↗

Laser applications in meteorology and earth and atmospheric remote sensing; Proceedings of the Meeting, Los Angeles, CA, Jan. 16-18, 1989

Various papers on laser applications in meteorology and earth and atmospheric remote sensing are presented. The individual topics addressed include: solid state lasers for the mid-IR region, tunable chromium lasers, GaInAsSb/AlGaAsSb injection lasers for remote sensing applications, development and design of an airborne autonomous wavemeter for laser tuning, fabrication of lightweight Si/SiC lidar mirrors, low-cost double heterostructure and quantum-well laser array development, nonlinear optical processes for the mid-IR region, simulated space-based Doppler lidar performance in regions of backscatter inhomogeneities, design of CO2 recombination catalysts for closed-cycle CO2 lasers, density measurements with combined Raman-Rayleigh lidar, geodynamics applications of spaceborne laser ranging, use of aircraft laser ranging data for forest mensuration, remote active spectrometer, multiwavelngth and triple CO2 lidars for trace gas detection, analysis of laser diagnostics in plumes, laser atmospheric wind sounder, compact Doppler lidar system using commercial off-the-shelf components, and preliminary design for a laser atmospheric wind sounder.

Sokoloski, Martin M.↗

Status of 2 micron laser technology program

The status of 2 micron lasers for windshear detection is described in viewgraph form Theoretical atmospheric and instrument system studies have demonstrated that the 2.1 micron Ho:YAG lasers can effectively measure wind speeds in both wet and dry conditions with accuracies of 1 m/sec. Two micron laser technology looks very promising in the near future, but several technical questions remain. The Ho:YAG laser would be small, compact, and efficient, requiring little or no maintenance. Since the Ho:YAG laser is laser diode pumped and has no moving part, the lifetime of this laser would be directly related to the diode laser lifetimes which can perform in excess of 10,000 hours. Efficiencies of 3 to 12 percent are expected, but laser demonstrations confirming the ability to Q-switch this laser are required. Coherent laser operation has been demonstrated for both the CW and Q-switched lasers.

Storm, Mark↗

Room temperature Dy:YLF laser operation at 4.34 micron

A Dy:YLF laser operating on the 6H11/2 to 6H13/2 transition at 4.34 micron and using a laser pumping scheme is reported. This pumping scheme is necessitated by the short upper-laser-level lifetime and the small effective stimulated-emission cross section. A suitable laser for this application is the Er:YLF laser operating at 1.73 micron. A simple model that approximates Dy:YLF laser performance well is presented. Results on laser performance, including a determination of the slope efficiency and threshold as a function of the output mirror reflectivity and a correlation of the pulse length with the laser output energy, are reported. Overall laser efficiency is found to be limited primarily by the ratio of the pump wavelength to laser output wavelength and the terminated four-level laser operation. Spectroscopic results, including the measurement of the absorption spectra and the lifetimes of both the upper- and lower-laser manifolds, are given.

Barnes, Norman P.↗

Time and wavelength domain algorithms for chemical analysis by laser radar

Laser-induced fluorescence (LIF) is a promising technique for laser radar applications. Laser radar using LIF has already been applied to algae blooms and oil slicks. Laser radar using LIF has great potential for remote chemical analysis because LIF spectra are extremely sensitive to chemical composition. However, most samples in the real world contain mixtures of fluorescing components, not merely individual components. Multicomponent analysis of laser radar returns from mixtures is often difficult because LIF spectra from solids and liquids are very broad and devoid of line structure. Therefore, algorithms for interpreting LIF spectra from laser radar returns must be able to analyze spectra that overlap in multicomponent systems. This paper analyzes the possibility of using factor analysis-rank annihilation (FARA) to analyze emission-time matrices (ETM) from laser radar returns instead of excitation-emission matrices (EEM). The authors here define ETM as matrices where the rows (or columns) are emission spectra at fixed times and the columns (or rows) are temporal profiles for fixed emission wavelengths. Laser radar usually uses pulsed lasers for ranging purposes, which are suitable for measuring temporal profiles. Laser radar targets are hard instead of diffuse; that is, a definite surface emits the fluorescence instead of an extended volume. A hard target would not broaden the temporal profiles as would a diffuse target. Both fluorescence lifetimes and emission spectra are sensitive to chemical composition. Therefore, temporal profiles can be used instead of excitation spectra in FARA analysis of laser radar returns. The resulting laser radar returns would be ETM instead of EEM.

Rosen, David L.↗

Alexandrite laser transmitter development for airborne water vapor DIAL measurements

In the DIAL technique, the water vapor concentration profile is determined by analyzing the lidar backscatter signals for laser wavelengths tuned 'on' and 'off' a water vapor absorption line. Desired characteristics of the on-line transmitted laser beam include: pulse energy greater than or equal to 100 mJ, high-resolution tuning capability (uncertainty less than 0.25 pm), good spectral stability (jitter less than 0.5 pm about the mean), and high spectral purity (greater than 99 percent). The off-line laser is generally detuned less than 100 pm away from the water vapor line. Its spectral requirements are much less stringent. In our past research, we developed and demonstrated the airborne DIAL technique for water vapor measurements in the 720-nm spectral region using a system based on an alexandrite laser as the transmitter for the on-line wavelength and a Nd:YAG laser-pumped dye laser for the off-line wavelength. This off-line laser has been replaced by a second alexandrite laser. Diode lasers are used to injection seed both lasers for frequency and linewidth control. This eliminates the need for the two intracavity etalons utilized in our previous alexandrite laser and thereby greatly reduces the risk of optical damage. Consequently, the transmitted pulse energy can be substantially increased, resulting in greater measurement range, higher data density, and increased measurement precision. In this paper, we describe the diode injection seed source, the two alexandrite lasers, and the device used to line lock the on-line seed source to the water vapor absorption feature.

Chyba, Thomas H.↗