Inverter Testing for Verification of Hawaiian Electric Rule 14H

As utilities increasingly require inverters to perform grid-supportive functions, it is challenging to ensure that those functions are properly configured in the field. This paper presents details of inverter testing related to Hawaiian Electric's latest rule 14H interconnection requirements to validate that field installation procedures result in the intended advanced inverter behavior. The latest Volt-VAR, Volt-Watt, and frequency-Watt curves in Hawaiian Electric's Source Requirement Document (SRD) V1.1 for UL 1741 Supplement A were tested for two inverter manufacturers used in the utility territory. Both inverters were found to be largely compliant, though several discrepancies were identified and reported to the manufacturers. The results are presented and discussed here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conductive Adhesives for Metallization of Interdigitated Back Contact Solar Cells

The metallization and interconnection of Si solar cells to form a module is usually a multi-step process: cells are metallized individually, soldered into strings, and subsequently assembled into a module. Furthermore, the metallization process for individual cells must be compatible with the doped surfaces being contacted, which creates additional challenges when moving from diffused junctions to heterojunctions and/or passivated contact structures. To mitigate these problems and streamline module manufacturing for the case of interdigitated back contact (IBC) cell modules, we developed an approach wherein unmetallized IBC cells are bonded directly to a circuitized backsheet using a conductive adhesive (CA) that only conducts out-of-plane. The metal/CA/silicon stack is bonded by hot-pressing at 100-200 degrees C.For a CA consisting of ethylene vinyl acetate (EVA) filled with Ag-coated spheres or indium powder we find that contact resistivities in the range of 1-10 Wcm 2 are obtained, regardless of which conductive filler and which hot pressing parameters are used. XPS revealed that about 1-2 nm EVA residue bonds to the Si in these samples, suggesting the formation of an insulating barrier that is responsible for the high contact resistance. Using indium powder alone, improved contact resistivities <0.6 Wcm 2 , high shunt resistances, and an implied open-circuit voltage loss below 10 mV were obtained. Furthermore, a cost estimate is presented, indicating that substantial cost savings of up to $10/m 2 , or about $0.05/W DC , are possible through CA-based IBC module manufacturing.

14 SOLAR ENERGY↗

III-V/Si Tandem Cells Utilizing Interdigitated Back Contact Si Cells and Varying Terminal Configurations

Integrating wide-bandgap III-V with Si solar cells has been shown to yield higher efficiencies than Si alone: As also presented at this conference, four-terminal efficiencies exceeding 32% have been attained. In this contribution, independent and electrically connected operation of the subcells in such tandem cells is examined. The optics of the tandem cell change significantly if a conducting interconnect, rather than an insulating glass slide, is required between the subcells. These effects are studied, and optically optimized structures for different types of tandem cell operation are presented. It is found that minimizing reflection at the conductive interface between the two cells while maintaining conductivity is the key challenge faced in such devices.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Environmental Influence on Fracture and Delamination of Electrically Conductive Adhesives

This paper presents our continued work on developing a degradation model for electrically conductive adhesive (ECA) interconnects in photovoltaic modules. Here, we characterize the fracture mechanics properties of an epoxy based ECA, for both critical and subcritical loading conditions. Emphasis is put on the influence of different environmental conditions such as temperature and humidity. We found that high levels of humidity not only weaken the adhesive joint but also promote subcritical debonding at significantly lower driving forces than in dry environments.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid-Forming and Grid-Following Inverter Comparison of Droop Response

With the increase in penetration of inverter-based resources (IBRs) in the electrical power system, the ability of these devices to provide grid support to the system has become a necessity. With standards previously developed for the interconnection requirements of grid-following inverters (GFLI) (most commonly photovoltaic inverters), it has been well documented how these inverters “should” respond to changes in voltage and frequency. However, with other IBRs such as grid-forming inverters (GFMIs) (used for energy storage systems, standalone systems, and as uninterruptable power supplies) these requirements are either: not yet documented, or require a more in deep analysis. With the increased interest in microgrids, GFMIs that can be paralleled onto a distribution system have become desired. With the proper control schemes, a GFMI can help maintain grid stability through fast response compared to rotating machines. This paper will present an experimental comparison of commercially available GFMI and GFLI ' responses to voltage and frequency deviation, as well as the GFMI operating as a standalone system and subjected to various changes in loads.

Grid Support, Inverter, Droop Control, Volt-VAR, F↗

Evaluation of PV Module Packaging Strategies of Monofacial and Bifacial PERC Using Degradation Pathway Network Modeling

As the PV industry is rapidly expanding, it is important to thoroughly investigate the long-term impact of packaging strategies on the performance of PV modules. In this study, the variants in sets differ on the basis of manufacturer (A/B), encapsulant (EVA/POE), rear encapsulant (UV-cutoff/opaque/transparent), module architecture (GB/DG) and cell type (monofacial/bifacial). The minimodules were exposed for 2520 hours in modified damp heat, with or without full spectrum light. Every 504 hours, stepwise electrical characterization techniques were employed to track changes in minimodules. Degradation pathway modeling using network structural equation modeling was employed to study pairwise relationships between variables and service lifetime prediction in minimodules. Through this study, differences in quality control are identified in minimodules made by different manufacturers. Minimodules with UV-cutoff rear encapsulant show relatively better stability, whereas the ones with opaque rear encapsulant show greater power loss. In addition, GB having UV-cutoff rear encapsulation and GB with POE having opaque rear encapsulation were identified to be stable as they lack a best model fit. Here, the primary power loss mechanism in degrading variants is interconnect corrosion.

14 SOLAR ENERGY↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Grid Integration of Renewable Energy and Energy Storage

Grid integration of renewable energy and energy storage requires forward-looking planning process, and increased emphasizes on reliability, resilience, and equity. Power-electronics based energy generation including solar, wind, distributed energy resources (DERs), and various types of grid-tied energy storage and emerging loads, are reshaping grid operator's understanding on interconnection level performance and responses. This paper will present the ongoing work at PNNL related to power electronics R&D, energy modeling and analysis, and a wide spectrum of grid stability studies and technologies in support of grid integration of renewable energy and energy storage.

Power Electronics, grid integration of renewable e↗

Towards the Quantum Internet: Entanglement Rate Analysis of High-Efficiency Electro-Optic Transducer

Coherent microwave-optical photon conversion is a key enabling technology for the Quantum Internet, since it allows entanglement distribution among superconducting-based network nodes. A high-efficiency electro-optic transducer based on three-dimensional superconducting radio-frequency (SRF) technology has recently been proposed at Fermilab. In this paper, we evaluate the impact of Fermilab's transduction hardware on the entanglement generation probability and the entanglement rate, which are two critical metrics from a communication engineering perspective. Furthermore, we provide some guidelines to increase the direct entanglement rate, i.e., the rate before any entanglement purification process. Our analysis shows that, through high-efficiency transduction, it is possible to reduce the network overhead. This preliminary work paves the way toward distantly interconnected superconducting quantum processors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Enabling Secure Grid Information Sharing through Hash Calendar-based Blockchain Infrastructures

The power grid is becoming increasingly interconnected, as information from grid operations must be accessible to an array of engineers, grid regulators, and market operators. However, there remain challenges ensuring the appropriate integrity and authenticity of the grid information. While traditional cryptographic protocols, like public key infrastructure, provide security for in-transit communication, they come with key exchanges and cost to get public key certificates from a centralized authority. To address these challenges, this paper demonstrates how a hash calendar-based blockchain can be used to provide improved security for communication with the use of distributed ledgers. It demonstrates the security requirements and threats to this communication, and then provides a theoretic definition of the process. Furthermore, it introduces a use-case of the proposed process within the WSU Smart City Testbed DMS with the Guardtime’s Keyless Signature Infrastructure (KSI) architecture.

Kaur, Kudrat J.↗

A Cyber-Resilience Risk Management Architecture for Distributed Wind

Distributed wind is an electric energy resource segment with strong potential to be deployed in many applications, but special consideration of resilience and cybersecurity is needed to address the unique conditions associated with distributed wind. Distributed wind is a strong candidate to help meet renewable energy and carbon-free energy goals. However, care must be taken as more systems are installed to ensure that the systems are reliable, resilient, and secure. The physical and communications requirements for distributed wind mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity risk management for distributed wind systems specifically. This research develops an architecture for the consideration of cyber risks associated with distributed wind systems. The architecture takes into account the configurations, challenges, and standards for distributed wind to create a risk-focused perspective that considers of threats, vulnerabilities, and consequences, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We discuss common distributed wind architectures and how they are interconnected to larger power systems. Because cybersecurity cannot exist independently, the cyber-resilience architecture must consider the system holistically. Finally, we discuss the implementation of a risk assessment process that uses the cyber-resilience framework to address challenges specific to distributed wind.

17 WIND ENERGY↗

What Role Do Aggregators Play in Power System Security and Resilience?

Barriers to the participation of distributed energy resources (DERs) in wholesale electricity markets have limited the use of DERs for power system security and resilience. In September 2020, the Federal Energy Regulatory Commission (FERC) approved an order to reduce these barriers. FERC Order No. 2222 enables the participation of DER aggregators in wholesale electricity markets. DERs include renewable generation and technologies that support the integration of renewable generation by increasing grid flexibility and resilience. Requiring wholesale energy markets to allow DER aggregator participation provides a path for DERs to become competitive in these markets. As the contribution from aggregated DERs continues to increase, the aggregator's role in supporting grid security and resilience will become more critical. This paper reviews work that demonstrates how DER aggregators can provide resilience support through technical capabilities, operational strategies, and secure communication architectures. Socioeconomic influences and impacts of aggregators, including implications for social resilience, are presented. In surveying the current state-of-the-art across different but interconnected topics, we illustrate how aggregators can be power system participants that enhance grid security. There is no one-size-fits-all approach to enhancing resilience in a power grid that includes a growing cohort of DER aggregators, but there are many options for aggregators to contribute to a more resilient and secure power grid.

aggregator↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

MDLoader: A Hybrid Model-Driven Data Loader for Distributed Graph Neural Network Training

Scalable data management is essential for processing large scientific dataset on HPC platforms for distributed deep learning. In-memory distributed storage is preferred for its speed, enabling rapid, random, and frequent data access required by stochastic optimizers. Processes use one-sided or collective communication to fetch remote data, with optimal performance depending on (i) dataset characteristics, (ii) training scale, and (iii) interconnection network. Empirical analysis shows collective communication excels with larger mini-batch sizes and/or fewer processes, whereas one-sided communication outperforms at larger scales. We propose MDLoader, a hybrid in-memory data loader for distributed graph neural network training. MDLoader features a model-driven performance estimator that dynamically selects between one-sided and collective communication at the beginning of training using Tree of Parzen Estimators (TPE). Evaluations on NERSC Perlmutter and OLCF Summit show MDLoader outperforms single-backend loaders by up to 2.83 × and predicts the suitable communication method with 96.3% (Perlmutter) and 94.3% (Summit) success rate.

Bae, Jonghyun↗