Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Fast Identification and Removal of Sequence Contamination from Genomic and Metagenomic Datasets

High-throughput sequencing technologies have strongly impacted microbiology, providing a rapid and cost-effective way of generating draft genomes and exploring microbial diversity. However, sequences obtained from impure nucleic acid preparations may contain DNA from sources other than the sample. Those sequence contaminations are a serious concern to the quality of the data used for downstream analysis, causing misassembly of sequence contigs and erroneous conclusions. Therefore, the removal of sequence contaminants is a necessary and required step for all sequencing projects. We developed DeconSeq, a robust framework for the rapid, automated identification and removal of sequence contamination in longer-read datasets (150 bp mean read length). DeconSeq is publicly available as standalone and web-based versions. The results can be exported for subsequent analysis, and the databases used for the web-based version are automatically updated on a regular basis. DeconSeq categorizes possible contamination sequences, eliminates redundant hits with higher similarity to non-contaminant genomes, and provides graphical visualizations of the alignment results and classifications. Using DeconSeq, we conducted an analysis of possible human DNA contamination in 202 previously published microbial and viral metagenomes and found possible contamination in 145 (72%) metagenomes with as high as 64% contaminating sequences. This new framework allows scientists to automatically detect and efficiently remove unwanted sequence contamination from their datasets while eliminating critical limitations of current methods. DeconSeq’s web interface is simple and user-friendly. The standalone version allows offline analysis and integration into existing data processing pipelines. DeconSeq’s results reveal whether the sequencing experiment has succeeded, whether the correct sample was sequenced, and whether the sample contains any sequence contamination from DNA preparation or host. In addition, the analysis of 202 metagenomes demonstrated significant contamination of the non-human associated metagenomes, suggesting that this method is appropriate for screening all metagenomes. DeconSeq is available at http://deconseq.sourceforge.net/.

59 BASIC BIOLOGICAL SCIENCES↗

A discrepancy within primate spatial vision and its bearing on the definition of edge detection processes in machine vision

The visual perception of form information is considered to be based on the functioning of simple and complex neurons in the primate striate cortex. However, a review of the physiological data on these brain cells cannot be harmonized with either the perceptual spatial frequency performance of primates or the performance which is necessary for form perception in humans. This discrepancy together with recent interest in cortical-like and perceptual-like processing in image coding and machine vision prompted a series of image processing experiments intended to provide some definition of the selection of image operators. The experiments were aimed at determining operators which could be used to detect edges in a computational manner consistent with the visual perception of structure in images. Fundamental issues were the selection of size (peak spatial frequency) and circular versus oriented operators (or some combination). In a previous study, circular difference-of-Gaussian (DOG) operators, with peak spatial frequency responses at about 11 and 33 cyc/deg were found to capture the primary structural information in images. Here larger scale circular DOG operators were explored and led to severe loss of image structure and introduced spatial dislocations (due to blur) in structure which is not consistent with visual perception. Orientation sensitive operators (akin to one class of simple cortical neurons) introduced ambiguities of edge extent regardless of the scale of the operator. For machine vision schemes which are functionally similar to natural vision form perception, two circularly symmetric very high spatial frequency channels appear to be necessary and sufficient for a wide range of natural images. Such a machine vision scheme is most similar to the physiological performance of the primate lateral geniculate nucleus rather than the striate cortex.

Jobson, Daniel J.↗

A four‐alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full‐field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet‐printed anthropomorphic phantom

Purpose The advent of three‐dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clinical trials are the gold standard for assessing image quality, phantom‐based studies can provide a simpler and less burdensome approach. In this work, a complete framework is presented for task‐based evaluation of microcalcification (MCs) detection performance for DBT imaging systems. Methods The framework consists of three parts. The first part is a realistic anthropomorphic physical breast phantom created through inkjet printing, with parchment paper and iodine‐doped ink. The second is a method for inserting realistic MCs fabricated from calcium hydroxyapatite. The reproducibility and stability of the phantom materials were investigated through multiple samples of parchment and ink over 6 months. The final part is an analysis using a four‐alternative forced choice (4AFC) reader study. To demonstrate the framework, a task‐based 4AFC study was conducted using a clinical system to compare performance from DBT, synthetic mammography (SM), and full‐field digital mammography (FFDM). Nine human observers read images containing MC clusters imaged with all three modalities and tried to correctly locate the MCs. The proportion correct (PC) was measured as the number of correctly detected clusters out of all trials. Results Overall, readers scored the highest with FFDM, (PC = 0.95 ± 0.03) then DBT (0.85 ± 0.04), and finally SM (0.44 ± 0.06). For the parchment and ink samples, the linear attenuation properties were very stable over 6 months. In addition, little difference was found between the various parchment and ink samples, indicating good reproducibility. Conclusions This framework presents a promising methodology for evaluating diagnostic task performance of clinical breast DBT systems.

Ikejimba, Lynda C.↗

The decay of HIV under anti-retroviral therapy is biphasic even in humanized mice with just T cells

HIV-1 plasma viral load decays in a biphasic manner during antiretroviral therapy (ART). It was hypothesized that this is due to infection of different cell types, namely CD4+ T cells and macrophages. We studied this possibility directly by modeling the decay of HIV-1 in humanized mice. We utilized previously published data from humanized T-cell only mice (TOM) and myeloid-only mice (MOM) infected with HIV-1 and treated with a potent ART regimen. Viral load decay dynamics were modeled using either a single or a biexponential decay fitted using nonlinear mixed effects techniques. Fits were compared using the corrected Bayesian information criterion (BICc). In TOM, the biphasic model was significantly better than a single-phase decay model (ΔBICc ≈ 16) despite additional parameters. In MOM, the biphasic decay was statistically better, but there was substantial uncertainty because the virus goes below detection very fast. The first-phase half-life was consistent between groups (1.2 days in MOM and 1.3 days in TOM) and similar to the half-life estimated in human infection. The second-phase decay in these mice was minimal likely due to low initial viral loads. Additional analyses with mice containing both CD4+ T cells and macrophages or X4-tropic virus-infected MOM mice confirmed the biphasic pattern, demonstrating the robustness of this result. The biphasic decline in HIV-1 occurs, even with only CD4+ T cells, refuting the hypothesis that distinct cell populations (CD4+ T cells and macrophages) drive each decay phase. These findings support an alternative model in which the observed dynamics arise from intrinsic properties of the viral infection lifecycle rather than from cellular compartmentalization.

59 BASIC BIOLOGICAL SCIENCES↗

Sorted-cell proteomics reveals an AT1-associated epithelial cornification phenotype and suggests endothelial redox imbalance in human bronchopulmonary dysplasia

Bronchopulmonary dysplasia (BPD) is a neonatal lung disease characterized by inflammation and scarring leading to long-term tissue damage. Previous whole tissue proteomics identified BPD-specific proteome changes and cell type shifts. Little is known about the proteome-level changes within specific cell populations in disease. Here, we sorted epithelial (EPI) and endothelial (ENDO) cell populations based on their differential surface markers from normal and BPD human lungs. Using a low-input compatible sample preparation method (MicroPOT), proteins were extracted and digested into peptides and subjected to liquid chromatography-tandem mass spectrometry (LC-MS/MS) proteome analysis. Of the 4,970 proteins detected, 293 were modulated in abundance or detection in the EPI population and 422 were modulated in ENDO cells. Modulation of proteins associated with actin-cytoskeletal function, such as SCEL, LMO7, and TBA1B was observed in the BPD EPIs. Using confocal imaging and analysis, we validated the presence of aberrant multilayer-like structures comprising SCEL and LMO7, known to be associated with epidermal cornification, in the human BPD lung. This is the first report of the accumulation of cornification-associated proteins in BPD. Their localization in the alveolar parenchyma, primarily associated with alveolar type 1 (AT1) cells, suggests a role in the BPD postinjury response. In the ENDOs, redox balance and mitochondrial function pathways were modulated. Alternative mRNA splicing and cell proliferative functions were elevated in both populations, suggesting potential dysregulation of cell progenitor fate. This study characterized the proteome of epithelial and endothelial cells from the BPD lung for the first time, identifying population-specific changes in BPD pathogenesis.

BPD↗

Toxicokinetics of benzo[a]pyrene in humans: Extensive metabolism as determined by UPLC-accelerator mass spectrometry following oral micro-dosing

Benzo[a]pyrene (BaP), produces tumors of skin, lung, liver, kidney and stomach in animals, enhances lung cancer in epidemiological studies and is a known human carcinogen. The EPA cancer slope risk factor for oral BaP exposure is 1 per mg/kg-day. The remarkable sensitivity (attomole 14C; precision 0.5-2% in biological samples) of accelerator mass spectrometry (AMS) makes possible [14C]-BaP dosing of humans with de minimus risk. A micro-dose of 46 ng (5 nCi), was given in 3 separate cycles to 5 human volunteers with a minimum 2 weeks between dosing. Blood was collected over 72 hours and BaP and BaP metabolites ([14C]-BaPeq) measured using AMS. [14C]-BaPeq appeared in plasma with an average Tmax of 75 minutes and Cmax 116-326 fM (29-82 fg/mL). Non-compartmental half-lives in plasma ranged from 30.7-114.2 hours and area under the curve values (AUC0-72 hr) 649-2060 fg x hr x mL-1. A two compartmental model yielded first-order rate constants (Ka, K12, K21, Kela and Kelß) of 0.92, 0.49, 0.12, 0.05 and 0.01 fg/hr, respectively. The T1/2a and T1/2ß were 1.14 and 89 hours, respectively. The actual interval between dosing was 20-420 days with no impact on a low intra-individual variation. No covalent [14C]-BaPeq-DNA adducts from peripheral blood mononuclear cells (PBMCs) were detected (LLOD of 10 fg [14C]-BaPeq adducts/mg DNA) 12-72 hours post-dosing negating the use of this cancer biomarker in risk assessment. We assert that the most relevant model for humans is humans. AMS and micro-dosing could be used to enhance the accuracy of pharmacokinetics and potentially risk assessments.

pharmacokinetcs, Polycyclic aromatic hydrocarbons↗

Field Soil Water Retention of the Prototype Hanford Barrier and Its Variability with Space and Time

Engineered surface barriers (or covers) are used to isolate underlying contaminants from water, plants, animals, and humans. To understand the flow processes within a barrier and the barrier's ability to store and release water, the field hydraulic properties of the barrier need to be known. A multiyear test of the evapotranspiration (ET) barrier at the US Department of Energy's Hanford Site in the southeast of the state of Washington has yielded in situ soil water content and pressure data from multiple locations for a 9‐yr period, offering the opportunity to estimate soil water retention properties at different locations and times. The upper 2‐m layer of the ET barrier is a silt loam, and the top 1 m also contains 15% (w/w) pea gravel. Within this layer, valid monitoring data from 1995 to 2003 for four depths at 12 monitoring stations were used to determine the field water retention of the silt loam, with and without gravel. The data covered a wide range of wetness, from near saturation to the permanent wilting point, and each retention curve contained 51 to 96 data points. The data were described well with the commonly used van Genuchten water retention model. It was found that the spatial variation of the saturated and residual water content and the pore size distribution parameter was relatively small, while that of the van Genuchten α was relatively large. The effects of spatial variability of the retention properties appeared to be larger than the combined effects of added pea gravel and plant roots on the properties. Neither the primary wetting process in the winter season nor the drying process in the summer season nor time had a detectable effect on the water retention of the silt loam barrier.

Zhang, Z. Fred↗

An ultrasonic technique to measure the depth of burn wounds in humans

Whenever ultrasound encounters discontinuity in its medium of propagation, some energy is reflected from the interface. Such reflections or echoes occur when incident energy encounters the front skin, viable/necrotic, and dermis/fat skin tissue interfaces. It was shown that the most probable cause of the viable/necrotic interface is the uncoiling of collagen in the necrotic tissue, which can cause a reflection at the viable/necrotic interface of approximately 10 percent of the wave amplitude, and is approximately the same as that from the other two interfaces noted. The instrument, still in the prototype stage, was designed to detect the various reflections from within the skin layer. It is shown that, by studying the timing between the various echoes, one can use ultrasound as an aid in diagnosing the depth of burned skin tissue in humans. The instrument is a 60-MHz A-scan unit, modified to more easily identify the echoes occurring within the short time interval during which the reflections are received from the skin layers. A high frequency unit was selected so that various transducers could be utilized to optimize the system. Signal conditioning circuits were modified and added to provide an adequate display of the principle reflections expected. The unit was successful in studying burned tissue in pigs and was recently used to study burn wounds in humans. Measurement techniques and preliminary results are presented.

Yost, William T.↗

Expanded diversity of novel hemoplasmas in rare and undersampled Neotropical bats

Hemotropic mycoplasmas are emerging as a model system for studying bacterial pathogens in bats, but taxonomic coverage of sampled host species remains biased. We leveraged a long-term field study in Belize to uncover novel hemoplasma diversity in bats by analyzing 80 samples from 19 species, most of which are infrequently encountered. PCR targeting the partial 16S rRNA gene found 41% of bats positive for hemoplasmas. Phylogenetic analyses found two novel host shifts of hemoplasmas, four entirely new hemoplasma genotypes, and the first hemoplasma detections in four bat species. One of these novel hemoplasmas (from Neoeptesicus furinalis) shared 97.6% identity in the partial 16S rRNA gene to a human hemoplasma (Candidatus Mycoplasma haemohominis). Additional analysis of the partial 23S rRNA gene allowed us to also designate two novel hemoplasma species, in Myotis elegans and Phyllostomus discolor, with the proposed names Candidatus Mycoplasma haematomyotis sp. nov. and Candidatus Mycoplasma haematophyllostomi sp. nov., respectively. Our analyses show that additional hemoplasma diversity in bats can be uncovered by targeting rare or undersampled host species.

16S rRNA gene↗

LINEBACKER: LINE-speed Bio-inspired Analysis and Characterization for Event Recognition

The cyber world is a complex domain, with digital systems mediating a wide spectrum of human and machine behaviors. While this is enabling a revolution in the way humans interact with each other and data, it also is exposing previously unreachable infrastructure to a worldwide set of actors. Existing solutions for intrusion detection and prevention that are signature-focused typically seek to detect anomalous and/or malicious activity for the sake of preventing or mitigating negative impacts. But a growing interest in behavior-based detection is driving new forms of analysis that move the emphasis from static indicators (e.g. rule-based alarms or tripwires) to behavioral indicators that accommodate a wider contextual perspective. Similar to cyber systems, biosystems have always existed in resource-constrained hostile environments where behaviors are tuned by context. So we look to biosystems as an inspiration for addressing behavior-based cyber challenges. In this paper, we introduce LINEBACKER, a behavior-model based approach to recognizing anomalous events in network traffic and present the design of this approach of bio-inspired and statistical models working in tandem to produce individualized alerting for a collection of systems. Preliminary results of these models operating on historic data are presented along with a plugin to support real-world cyber operations.

biosequence model↗

Objective assessment of image quality and dose reduction in CT iterative reconstruction

Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

60 APPLIED LIFE SCIENCES↗

Humming Trains in Seismology: An Opportune Source for Probing the Shallow Crust

Abstract Seismologists are eagerly seeking new and preferably low-cost ways to map and track changes in the complex structure of the top few kilometers of the crust. By understanding it better, they can build on what is known regarding important, practical issues. These include telling us whether imminent earthquakes and volcanic eruptions are generating telltale underground signs of hazard, about mitigation of induced seismicity such as from deep injection of wastewater, how the Earth and its atmosphere couple, and where accessible natural resources are. Passive seismic imaging usually relies on blind correlations within extended recordings of Earth’s ceaseless “hum” or coda of well-mixed, small vibrations. In this article, we propose a complementary approach. It is seismic interferometry using opportune sources—specifically ones not stationary in time and moving in a well-understood configuration. Its interpretation relies on an accurate understanding of how these sources radiate seismic waves, precise timing, careful placement of pairs of listening stations, and seismic phase differentiation (surface and body waves). Massive freight trains were only recently recognized as such a persistent, powerful cultural (human activity-caused) seismic source. One train passage may generate a tremor with an energy output of a magnitude 1 earthquake and be detectable for up to 100 km from the track. We discuss the source mechanisms of train tremors and review the basic theory on sources. Finally, we present case studies of body- and surface-wave retrieval as an aid to mineral exploration in Canada and to monitoring of a southern California fault zone. We believe noise recovery from this new signal source, together with dense data acquisition technologies such as nodes or distributed acoustic sensing, will deeply transform our ability to monitor activity in the shallow crust at sharpened resolution in time and space.

Geochemistry & Geophysics↗

Transfer Learning using Denoising Auto-Encoders for Cellular-Level Annotation of Tumor in Pathology Slides

Adversarial examples can produce altered classifications using only seemingly innocuous, imperceptible perturbations to the original image. The imperceptibility of adversarial perturbations suggests that the corresponding classifiers use decision criteria different than those of a human. In a medical setting, inexplicable decision criteria confound a pathologist’s willingness to trust machine-generated annotations. Here, we analyze denoising tumor detection models to see if they are robust to imperceptible adversarial perturbations. Moreover, to be more fully trusted by pathologists, we require tumor detectors that generate interpretable annotations which segment pathology slides into tumorous and normal regions at the cellular level. We therefore compare transfer learning based on two different autoencoder architectures, one derived from a deep denoising bottleneck autoencoder and one from an over-complete sparse autoencoder. Both autoencoders were first trained in an unsupervised manner on a set of pathology slides drawn from the Camelyon16 dataset. The latent representations produced by each autoencoder were then passed to separate neural networks that were trained in a supervised manner on binary tumor-normal masks generated by pathologists at cellular resolution. Both tumor detectors supported better than 90% AUC PR as measured by the area under the precision/recall curve on a held-out pathology slide. To assess the underlying decision criteria used by both tumor detectors, we constructed imperceptible adversarial examples which reduced the AUC PR of both models to less than 70%. Random noise of the same amplitude had almost no effect on the AUC PR of either model. Additionally, each tumor detector was resistant to adversarial “transfer” attacks targeting the other. The adversarial perturbations showed strong characteristic differences: the deep denoising models perturbations were a very diffuse, seemingly unrecognizable pattern while the sparse coding models perturbations showed traces of tissue cells.

47 OTHER INSTRUMENTATION↗

Detection of boundary-layer transitions in wind tunnels

Accelerometer replaces stethoscope in technique for detection of laminar-to-turbulent boundary-layer transitions on wind-tunnel models. Technique allows measurements above or below atmospheric pressure because human operator is not required within tunnel. Data may be taken from accelerometer, and pressure transducer simultaneously, and delivered to systems for analysis.

Wood, W. R.↗

Lessons learned from the introduction of autonomous monitoring to the EUVE science operations center

The University of California at Berkeley's (UCB) Center for Extreme Ultraviolet Astrophysics (CEA), in conjunction with NASA's Ames Research Center (ARC), has implemented an autonomous monitoring system in the Extreme Ultraviolet Explorer (EUVE) science operations center (ESOC). The implementation was driven by a need to reduce operations costs and has allowed the ESOC to move from continuous, three-shift, human-tended monitoring of the science payload to a one-shift operation in which the off shifts are monitored by an autonomous anomaly detection system. This system includes Eworks, an artificial intelligence (AI) payload telemetry monitoring package based on RTworks, and Epage, an automatic paging system to notify ESOC personnel of detected anomalies. In this age of shrinking NASA budgets, the lessons learned on the EUVE project are useful to other NASA missions looking for ways to reduce their operations budgets. The process of knowledge capture, from the payload controllers for implementation in an expert system, is directly applicable to any mission considering a transition to autonomous monitoring in their control center. The collaboration with ARC demonstrates how a project with limited programming resources can expand the breadth of its goals without incurring the high cost of hiring additional, dedicated programmers. This dispersal of expertise across NASA centers allows future missions to easily access experts for collaborative efforts of their own. Even the criterion used to choose an expert system has widespread impacts on the implementation, including the completion time and the final cost. In this paper we discuss, from inception to completion, the areas where our experiences in moving from three shifts to one shift may offer insights for other NASA missions.

Lewis, M.↗

Utility of Lava Tubes on Other Worlds

On Mars, as on Earth, lava tubes are found in the extensive lava fields associated with shield volcanism. Lunar lava-tube traces are located near mare-highland boundaries, giving access to a variety of minerals and other resources, including steep slopes, prominent heights for local area communications and observation, large-surface areas in shade, and abundant basalt plains suitable for landing sites, mass-drivers, surface transportation, regolith harvesting, and other uses. Methods for detecting lava tubes include visual observations of collapse trenches and skylights, ground-penetrating radar, gravimetry, magnetometry, seismography, atmospheric effects, laser, lidar, infrared, and human or robotic exploration.

Walden, Bryce E.↗

Hybrid Modeling for Testing Intelligent Software for Lunar-Mars Closed Life Support

Intelligent software is being developed for closed life support systems with biological components, for human exploration of the Moon and Mars. The intelligent software functions include planning/scheduling, reactive discrete control and sequencing, management of continuous control, and fault detection, diagnosis, and management of failures and errors. Four types of modeling information have been essential to system modeling and simulation to develop and test the software and to provide operational model-based what-if analyses: discrete component operational and failure modes; continuous dynamic performance within component modes, modeled qualitatively or quantitatively; configuration of flows and power among components in the system; and operations activities and scenarios. CONFIG, a multi-purpose discrete event simulation tool that integrates all four types of models for use throughout the engineering and operations life cycle, has been used to model components and systems involved in the production and transfer of oxygen and carbon dioxide in a plant-growth chamber and between that chamber and a habitation chamber with physicochemical systems for gas processing.

Malin, Jane T.↗

Classification image weights and internal noise level estimation

For the linear discrimination of two stimuli in white Gaussian noise in the presence of internal noise, a method is described for estimating linear classification weights from the sum of noise images segregated by stimulus and response. The recommended method for combining the two response images for the same stimulus is to difference the average images. Weights are derived for combining images over stimuli and observers. Methods for estimating the level of internal noise are described with emphasis on the case of repeated presentations of the same noise sample. Simple tests for particular hypotheses about the weights are shown based on observer agreement with a noiseless version of the hypothesis.

Pattern Recognition, Visual/physiology↗